roger schult german audio lab Universalfilter W2377 MK2 Operating Manual Quick Guide

Similar documents
roger schult Vintage 3-Band EQ W2395c Operating Manual Quick Guide

ZM 84 Audio Mixer. User Manual. Order code: CRAM41. Audio Mixer ZM 84 AUX 3 AUX 1 AUX 2 AUX 4 MASTER 1 MASTER 2 OFF BASS BASS TREBLE TREBLE BASS BASS

T L Audio CRIMSON SERIES. User Manual EQ-3011 EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

AMPLIFICAZIONI LAST 1000S. manual

E-400 power amplifier. user manual

T L Audio CRIMSON SERIES. User Manual EQ-3012 PARAMETRIC EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

Model 7000 Low Noise Differential Preamplifier

CX-A6 Amplifier Installation & User Guide V8.0

E-800 power amplifier. user manual

BROADBAND PREAMPLIFIER MODEL BPA khz 1 GHz

PROFESSIONAL STEREO AMPLIFIERS USER GUIDE

DMP40. User Manual.

E-800 power amplifier. user manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual

mix 502, mix 802, mix 1202FX mixer user manual

MZ2 HEADPHONE AMPLIFIER, PREAMP, & STEREO AMPLIFIER USER GUIDE

TMP40. User Manual.

DX 48 DX 24 DX 12 D X - S e r i e s

CX-A6 Amplifier Installation & User Guide V9.0

DN370 ## ## Equalizers. Dual 30 Band, 1/3 Octave Analogue Graphic Equaliser with Enhanced Proportional-Q Response and Four-Band Filtering

PREQ-1. Vacuum Tube Recording Channel. Rev. 6 Date: 09/07/2017 OWNER S MANUAL

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

T L Audio. User Manual EQ1 VALVE EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

Model 1791 VHF Radio User's Manual

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

T L Audio INDIGO SERIES. User Manual VP-2051 VALVE VOICE PROCESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

HARMONY SINGER 2. Battery-Powered Vocal Effects Stompbox with Guitar-Controlled Harmony, Reverb and Tone. User Manual

SPLIT.CONVERTER. User's Manual. Version 2.0

2-Slot Desktop Chassis (DC) Extended Temperature

Visit us at

WX-1 & WX-3 OPERATING MANUAL AND USER GUIDE. Professional Power Amplifier. WX-1 and WX-3.indd :23:16

OCV 6. Product Description. Features. Applications

DIVERSE MAGMETER MF500M+ USER MANUAL. Contents INTRODUCTION FIRST TIME - QUICK START OPERATION OPERATION - OPTIONS MAGNETITE METER

VLS 15. Technical Data Sheet. Product description

DIVERSE MAGMETER MF500M MAGNETITE METER USER MANUAL. CAMBRIDGE ENGLAND CB22 5EW.

ULTRA-K Series 600K - he

The elysia team wishes you great delight and compression deluxe with your new mpressor 500.

SA 125 mixer amplifier. user manual

Our Mailing and Shipping Address:

Aura Audio D2i MANUAL Version 1.0 SAFETY INSTRUCTIONS

CIRCUIT-TEST ELECTRONICS

VLS 7 (EN 54) # Designed and engineered in the U.K.

TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X power amplifier. user manual

RU210. Dual Multi-UHF Wireless System. Item ref: UK, UK User Manual. Version 1.0

TETRIS User's Guide. High Impedance Active Probe DO177-1

Owner s Manual. English. German Engineering. Out of the ordinary.

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

HX-3. Headphone Distribution Amplifier User Guide and Technical Information

HX-3 Headphone Distribution Amplifier

MP-1 Microphone Preamplifier User Guide and Technical Information

Digital Function Generator

VLS 30. # Designed and engineered in the U.K.

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

OCV 6. Install. 6" Coaxial Pendant Loudspeaker for Installation Applications. Coaxial full range pendant loudspeaker for installation applications

VLS 15 (EN 54) # Designed and engineered in the U.K.

Summit Audio Model EQP-200B Dual Program Equalizer Operating Manual

User's Guide QuadMic

DVS 4 / DVS 4t. Features. Product Description. Applications

E-400 endstufe. user manual

CMS 603DC BM. Optimised for Installation

4 Channel Frequency Conscious Noise Gate. Operation Manual

User Manual. MA 240 Mixing amplifier

Model Microphone Preamplifier Power Supply Manual

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

D4-500 digital power amplifier. user manual

POWERVS10 BP. Product Description. Features. Applications

FISCHER AMPS MANUAL. In Ear Amp 2

TSA 4-700, TSA 1400, TSA 2200, TSA 4000, TSA 4-300, TSA power amplifier. user manual

Product Description. Features. Applications

IQBDA7 Analog Audio Distribution Amplifier

Always there to help you. Register your product and get support at AJ5305D_12. Question? Contact Philips.

MIXER POWER AMPLIFIER BG-130

SR Series Crossovers. Owner s Manual SR 823 SR 834. A Harman International Company

audionet AMP 1 V2 User s Manual Stereo - Amplifier

MIC MECHANIC 2. Ultra-Simple Battery-Powered Vocal Effects Stompbox with Echo, Reverb and Pitch Correction. User Manual

model 101 single channel microphone preamplifier owner s manual Rev C

CVS 6 # # Exceptional Sound and Reliability

Always there to help you. Register your product and get support at AJ5305D/05. Question? Contact Philips.

USER MANUAL VIVALDI MZ550A. Distribution Mixer Amplifier


CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

KWM Quartet Wireless microphone system

KLASIK NEAR FIELD ACTIVE STUDIO MONITOR

PREZONE1 Instruction manual

Amplifier Series BASIC. Installation & Operations Manual

DPA74/154 AUDAC PROFESSIONAL AUDIO EQUIPMENT. DPA74/154 Quad Channel Class-D Amplifier. User Manual & Installation Guide

VLS 15. Technical Data Sheet. Product description. Features

TWS 16 HT UHF wireless system. user manual

poly-planar ME-51 Subwoofer Amplifier Waterproof Marine Audio

Keysight 86205B RF Bridge

V-9927A DIGITAL MULTI-TONE GENERATOR

ALM473 DUAL MONO \ STEREO AUDIO LEVEL MASTER OPERATION MANUAL IB

Ver Tornado KT2 - KT2C KTL2 - KTL2C. USER GUIDE English KT2 KTL2 KT2C KTL2C

Autoranging Multimeter Extech EX503

TWS 16 PT UHF wireless system. user manual

Page/Talk Weatherproof Wall Stations Models MLW80 and MLW85

E4-130, E4-250 power amplifier. user manual

Model CC4041. CC Series Amplifier. Installation and Use Manual

TOA 500 SERIES MIXER POWER AMPLIFIER

Digital Clamp Meter Model: &

Transcription:

roger schult german audio lab Universalfilter W2377 MK2 Operating Manual Quick Guide W2377 MK2 (5th anniversary) Operating Manual for api 500 system Version 02.2015 roger schult D 50374 Erftstadt Peter-May-Str. 104-1 -

Table of Contents Page 2 Table of Contents 3 Introduction Safety Notices 4 Product Details Controls and Operation 5 Installation Installing the W2377 MK3 module in an api 500 system Recycling 6 Specifications 7 Box contents and compatibility 8 Manufacturer, contact and support api is a registered trademark of AUTOMATED PROCESSES, INC., NEW YORK, USA -2 -

Dear customer, we sincerely thank you for purchasing our product. The W2377 MK2 module for the api 500 system that you have purchased was manufactured according to highest manufacturing standards adhering to all European and national guidelines currently in effect. EMV compatibility has been certified and the appropriate records are available at the manufacturer. Upon shipment, the product left the manufacturer in perfect working condition according to factory specifications. In order to maintain the factory specs and guarantee safe operation in the future, we advise that you read the included operating manual as well as further safety documents (see below) - they contain important notes for operating and handling your product. When passing the unit on to third parties, please also make them aware of these documents. Any use outside of the applications described in this manual may cause damage to the product and may further imply to hazards such as electrical shorts, fire, electric shocks, etc. The product must not be altered or modified. The enclosed safety and hazard notices about this product refer to the installation and operation in an api 500 system. Consequentially, there may be relevant guidelines and regulations that affect operation, even if they don t apply to our product directly. Installation and operation should therefor be carried out by trained personell only. Operating the product in adverse conditions such as in contact with water or excessive humidity, dust, gases, fumes or solvents is not permitted. If you should have technical questions to this product, please contact our technical support team. You will find the contact details in the appendix of this manual. -3 -

Controls and Operation The universal filter W2377 MK2 is designed for the api 500 system and covers the entire audio spectrum from 20 Hz to 23.3 khz in a single filter unit. Selecting the frequency range in three filter decades via the toggle switch provides accurate frequency resolution for the most difficult tasks. This range switch enables changing the working frequency range by a factor of 0.1 for the low frequency band, 1 for the mid band, and 10 for the upper frequency band. With a convenient overlap between the crossover frequencies a wide spectrum can be adjusted with ease. Gain (rotary control) The module has one rotary gain potentiometer with a range of -10 db to +10 db. range (toggle switch) The frequency range of the frequency control is set via a toggle switch - in the low band ( x0.1) between 20 Hz and 233 Hz - in the mid band (x1) between 200 Hz and 2.33 khz - in the high band (x10) between 2 khz and 23.3 khz Frequency (rotary control) The frequency control adjusts the filter frequency with a scale from 0.2 khz and 2.33 khz, but the actual frequency range depends on the setting of the range toggle switch as follows: 20 Hz - 233 Hz for the low band (toggle switch in down position), 0.2 khz - 2.33 khz for the mid band (toggle switch centered), and 2 khz - 23.3 khz for the high band (toggle switch in up position). Q-factor (rotary switch) A rotary switch adjusts the quality factor of the bandpass filter between Q = 0.3 (wide) to Q = 10 (narrow) in nine steps. The module is further capable of serving as a high pass (HP) or low pass (LP) when the rotary switch is set to the left and right extreme position. on -switch The LED backlit on pushbutton switch activates the filter in its depressed position. When turned off the filter will be silently removed from the signal chain ( hard bypass ). Jumper settings Several additional features are available via jumper settings on the unit s circuit board. To adjust these jumper settings, the enclosure has to be opened carefully by removing the four Philips screws. Please also refer to the downloads section on the Roger Schult homepage at www.rogerschult.com. Please take note of the jumper positions before making any changes. The brightness of the on -switch LED may be adjusted in three steps by removing jumpers K6 and K9. The jumpers can be removed by gently pulling them upwards. If both jumpers are inserted, the LEDs will be the brightest. If only jumper K6 is inserted, the LEDs will be at their medium brightness. The lowest brightness setting is achieved if only jumper K9 is inserted. The low and high pass filter functions of the Q-factor switch can be deactivated by pulling the jumpers K29 and K30. If both jumpers are inserted, both the high pass (HP) and the low pass (LP) are operational. Removing the jumpers for the high pass (K30) or low pass (K29) deactivates them. -4 -

Installation in an api 500 system Instructions for installing the W2377 MK2 filter module Please note that electric potential differences and electrostatic discharges (ESD) can destroy your api 500 system and the W2377 MK2 module. Please make sure to discharge any potential electrostatic charges by touching a plumbing pipe, heating pipe or any other piece of metal connected to earth before installing the W2377 MK2 module. Neutral electric potential is a prerequisite to any installation or reconfiguration of electronics modules and their interconnections. Turn off your api 500 rack or console and all connected devices. Remove any blank panels that might cover the slot you have chosen for installation of the module. Center the module between the two threaded mounting holes with the shield of the module frame facing to the left and evenly insert the module into the free slot without applying brute force. Secure the W2377 MK2 module with both screws. The module is ready for operation once the appropriate connections in the rear of the api box have been taken care of. Recycling Please stay eco-friendly and dispose of all defective and obsolete devices at a certified collection facility according to local laws and regulations. The crossed out wheels bin label that can be found on your product indicates that this product should not be disposed of via the normal household waste stream. To prevent possible harm to the environment or human health please separate this product from other wast streams to ensure that it can be recycled in an environmentally sound manner. For more details on available collection facilities please contact your local waste management office or the retailer where you purchased this product. -5 -

Specifications Tentative spec sheet, 02/2015 High frequency filter (x10), up position 2 khz to 23.3 khz Mid frequency filter (x1), center position 200 Hz to 2.3 khz Low frequency filter (x0.1), down position 20 Hz to 233 Hz Gain, continuously variable rotary control +/- 10 db Q-factor, 11-position switch 0.3 / 0.5 / 0.7 / 1.0 / 1.5 / 2.5 / 4 / 6 / 10 as well as LP and HP on, LED backlit pushbutton enable / disable filter module, hard-bypass Input (electronically balanced) Reference input level Maximum input level with linear setting Input impedance +6 dbu +23 dbu 10 kohm Output (electronically balanced) Reference output level +6 dbu Max. Maximum output level +26 dbu / (0.05% THD+N) Output impedance 40 Ohm Gain at linear setting 0 db at 1 khz (+0.1 / -0.2 db) Signal-to-noise ratio < 100 db Noise level (UWTD / WTD) < 80 dbq / < 76 dbq Harmonic distortion THD+N / 0 dbu 0.01% Frequency range 20 Hz - 40 khz (+ 0.1 /- 0.2 db) Delay time of hard bypass relais max. 3 ms Power supply +/- 16 V via api -system + max. 120 ma / -16V max. 60 ma Module dimensions 115 mm x 172 mm (height x depth) Faceplate dimensions 19 / 3 RU, 1.5 x 5.25 (width x height) Faceplate finish Aluminum, chromated Aluminium, white powder coat ( 5th ) Weight 0.55 kg -6 -

Box contents and compatibility Box contents - W2377 MK2 module for api 500 system - Quick start guide in German - Quick start guide in English Compatibility The compatibility certification records for this product are available upon request from the manufacturer. As all Roger Schult products, the W2377 MK2 is hand-crafted and precision-engineered in Germany. roger schult german audio lab D 50374 Erftstadt Peter-May-Strasse 104 www.rogerschult.com info@rogerschult.com -7 -

Manufacturer roger schult german audio lab Peter-May-Str.104 D 50374 Erftstadt www.rogerschult.com info@rogerschult.com Model: Model: Aluminum, chromated Aluminium, white powder coat -8 -