This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

Similar documents
Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Linear Power Supplies Data Sheet

Three-phase AC input. Suitable for 3U or 5U height mounting. Single-wire current share or Droop current share

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

SFD550-12BG Front-End Preliminary Data Sheet DC Input, 12V Output, 550 Watts

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

General. Environmental. EMC & Safety

LB115S 115W Single Output

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

Series AM50E-NZ 50 Watt DC-DC Converter

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

Very high efficiency up to 96.5% Up to 15 kw power. CAN bus serial interface. Adjustable output voltage. Protection degree IP67

Electrical Specifications

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

Electrical Specifications

C B. Models. Models 2MOPP

Product Specification sheet

TE60 60W Single Output External Power Test & Measurement/Industrial Series

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

Electrical Specifications

TE60 60W Single Output External Power Test & Measurement/Industrial Series

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

Series AMEOW10-NZ 10 Watt AC-DC / DC-DC Converter

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

General. Environmental. EMC & Safety

Series AMSRL1-78JZ Up to 12 Watt DC-DC Switching Regulator

TE W Single Output External Power Test & Measurement/Industrial Series

Power Supplies. Certifications and Compliances Recognized Component, ITE - UL Certified, ITE - CSA C22.2 CSA

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

CCH400 & CCH600 Series

TB65 65W Single Output Test and Measurement/Industrial Series

Output Voltage (Vfan) Convection-cooled (6,7) Forced-cooled (8) & Current

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.

AC/DC Power Supply Single-Output

TC-600PD2. Switching Power Supply ( 600W PS2 ATX12V ) SPECIFICATION. Revision: 1.0

150 Watt Industrial (WLT)

Output Voltage (Vfan) & Current

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

TE90 90W Single Output External Power Test & Measurement/Industrial Series

18093-PS PHIHONG TECHNOLOGY CO., LTD. General Specification PSM (DC)

Electrical Specifications

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

POWER. NLP40 Series. Single, Dual and Triple Output. Data Sheet

ST-250MAK-05E. Switching Power Supply SPECIFICATION

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE

IP67 DESCRIPTION KEY FEATURES MARKET SEGMENT AND APPLICATIONS TRC ELECTRONICS, INC

Watts HCP Series

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

For more information, please visit the product page. output. output current max (A)

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

VOF XX - XXX - X

Doc. EA Model Number:

Series AM30EW-Z 30 Watt DC-DC Converter

SPECIFICATION. SilverStone OLYMPIA OP1000 Switching Power Supply Active PFC

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

Electrical Specifications

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

REVISIONS 06/26/06 YS TEMPS FILE NAME: CAD1:MSWORD:PA DOC SCALE: NONE REV: D SH 1 OF 7 TITLE: OVS-U (UNIVERSAL INPUT) SERIES SPECIFICATION

High Power Modular Products Data Sheet

MB120S 120W Single Output Medical Series

ABC400 Series is a compact and efficient series of AC-DC open frame power supplies suited for telecom, datacom and many other applications.

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE BPS-460RDX 6-OUTPUT 460W+460W BEST POWER SOLUTIONS, INC.

LFWLP W 12V 15.00A 25.00A 92%

DDP400 and MDP400, SC series, are sealed, full potted, compact, high efficiency, small form factor AC-DC power supplies.

Transcription:

RoHS Lead-Solder-Exemption Compliant Automatic 115/230 Input Voltage Selection All Outputs Fully Regulated Remote Sense, Overvoltage Protection and Overtemperature Protection Power Fail Signal Included Greater than 100,000 Hour MTF U-Channel Chassis: 8.5 x 4.5 x 2.0 inch (215.9mm x 114.3mm x 50.8mm) Optional Cover Metric and SAE Mounting Inserts el Power Solutions of single and multiple output power supplies provide fully-regulated outputs with high peak current capabilities in a compact 4.5 x 8.5 x 2.0 inch U-channel chassis. Other standard features include auto select AC input, EMI level filtering, power fail, thermal shutdown (with warning), remote sense, and metric and SAE mounting inserts. This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C. All products are approved to the latest international regulatory standards and display the CE Mark. North America +1- Asia-Pacific +86.755.29885888 Europe, Middle East +353 61 225 977

MODEL VOLTAGE ADJUSTMENT RANGE CONTINUOUS CURRENT PEAK CURRENT 1 LINE LOAD RIPPLE & NOISE 2 INITIAL SETTING ACCURACY MAP130-1005 5V 4.75V to 5.50V 26A 30A 0.2% 1% 1% 5.1V to 5.2V MAP130-1012 12/15V 11.4V to 15.75V 12A/10A 3 13.8A/11A 3 0.2% 1% 1% 12.0V to 12.2V MAP130-1024 24V/28V 22.5V to 30.0V 6.25A/5.4A 3 6.8A/5.9A 3 0.2% 1% 1% 23.9V to 24.1V MODEL MAP130-4000 MAP130-4001 MAP130-4002 MAP130-4003 MAP130-4004* MAP130-4010 MAP130-4020* VOLTAGE ADJUSTMENT RANGE CURRENT PEAK CURRENT 4 LINE LOAD RIPPLE & NOISE 5 INITIAL SETTING ACCURACY +12V 11.5V to 12.5V 5A 10A 0.5% 2% 1% 11.75V to 12.0V -5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.2V +24V 23.0V to 25.0V 3.5A 5A 0.5% 2% 1% 23.9V to 24.1V +12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V +12V 11.5V to 12.5V 5A 10A 0.5% 2% 1% 11.9V to 12.1V +12V Fixed 1A 1A 0.5% 2% 1% 11.6V to 12.4V +5V 4.75V to 5.50V 20A 30A 1% 1% 1% 5.1V to 5.2V +15V 14.0V to 16.0V 4A 8A 1% 2% 1% 15.0V to 15.1V -5V Fixed 1A 1A 2% 2% 1% -4.8V to -5.2V -15V Fixed 1A 1A 2% 2% 1% -14.7V to -15.3V +5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.15V to 5.2V +24V 23.0V to 25.0V 3.5A 5A 0.5% 2% 1% 23.9V to 24.1V -15V Fixed 1A 1A 0.5% 2% 1% -14.5V to -15.5V +15V Fixed 1A 1A 0.5% 2% 1% 14.5V to 15.5V +5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.25V +12V 11.5V to 12.8V 5A 10A 0.5% 2% 1% 11.75V to 12.0V -5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.2V -12V Fixed 3A 3A 0.5% 2% 1% -11.6V to -12.4V +5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.25V +12V 11.5V to 12.8V 5A 10A 0.5% 2% 1% 11.75V to 12.0V -5V Fixed 3A 3A 0.5% 2% 1% -4.8V to -5.2V 1 Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. 2 Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 3 MAP130-1012 output currents are expressed as 12V/15V operation. MAP130-1024 output currents are expressed as 24V/28V operation. 4 Peak loads up to 165 Watts, (total of all outputs), for 60 seconds or less are acceptable, (10% duty cycle max.). 5 Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. Oooo Model numbers highlighted in yellow are not recommended for new designs. * Obsolete

Input Voltage - AC Auto-ranging Low Range High Range Input Frequency AC input 47 63 Hz rown Out Protection Lowest AC input voltage when regulation is maintained with full rated loads. 90 175 115 230 132 264 VAC 90 VAC Hold-up Time Nominal AC input voltage (115 VAC) 130 W load: 40 ms Input Current 90 VAC, 130W load 3.3 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 264 VAC (one cycle). 25 C. 38 APK Operating Frequency Switching frequency of main transformer. Range: 16 120 khz Efficiency Full Load @ 115 VAC (Varies with distribution of loads among outputs.) 71% typical Minimum Loads MAP130-1012 MAP130-1024 MAP130-1005 and all multiple output models, main channel only Ripple and Noise Full Load, 20 MHz andwidth. See Model Selection Chart Output Power Continuous output power, all multiple output models. Peak output power (60s max., 10% duty cycle), all multiple output models. Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on / turn-off. 1 % Regulation Transient Response Varies by output, regulation includes: line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only on multiple output units). 1.25 0.63 3.00 130 165 See Model Selection Chart Amps Watts 500 µs Turn-on Delay Time required for initial output voltage stabilization. 2 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 ms Overvoltage Protection Overcurrent Protection Provided on single output units and only the main output of multiple output units. All models have inherent short circuit protection. Units will automatically restart at the removal of the fault. MAP130-1012 MAP130-1024 MAP130-4004 All other models Remote Sense Total voltage compensation for main output cable losses. 250 mv Power Fail Warning 6 Overtemperature Warning 7 Logic LO (denotes power fail detected). 0.7 V Logic HI with internal pull-up to output. 10 kω Power Fail trip point, maximum load, decreasing line. 86 94 VAC Time before regulation dropout, at full load, due to loss of input power. 5 ms Warning prior to system shutdown due to excessive internal temperatures. Shifts Power Fail signal to a logic LO state. 17.0 32.0 6.2 5.5 22.0 37.0 7.4 6.8 VDC 20 ms 6 Power Fail not available on MAP130-1012 and MAP130-1024. 7 MAP130-1012 and MAP130-1024 have overtemperature protection, but do not have the warning feature.

Agency Approvals Dielectric Withstand Voltage Electromagnetic Interference Approved to the latest edition of the following standards; UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd. Input to Chassis Input to Output (tested by manufacturer only) FCC CFR title 47 Part 15 Sub-Part - Conducted EN55022 / CISPR 22 conducted EN55022 / CISPR 22 radiated 8 ESD Susceptibility Per EN61000-4-2, level 4 8 kv Radiated Susceptibility Per EN61000-4-3, level 3 10 V/M EFT/urst Per EN61000-4-4, level 3 9 ±2 kv Input Transient Protection EN61000-4-5 Level 3 Line to Line Line to Ground Insulation Resistance Input to output 7 MΩ Leakage Current Per EN60950, 264 VAC 700 μa 2121 4242 1 2 VDC Class kv Altitude Operating Temperature 10 Operating Non-operating Derate linearly above 50 C by 2.5% per C At 100% load: At 50% load: Storage Temperature -40 85 C Temperature Coefficient 0 C to 70 C (after 15 minute warm-up) ±0.02 ±0.05 %/ C Relative Humidity Non-condensing 5 95 %RH Shock Operating, peak acceleration 20 GPK Vibration Random vibration, 10Hz to 2kHz, 3 axis 6 GRMS 0 0 10k 40k 50 70 Feet C PARAMETER CONDITIONS / DESCRIPTION Dimensions 215.9 x 114.3 x 50.8 mm (8.50" x 4.50" x 2.00") Weight Cover (Option) 1.13 kg (2.5 lbs) Add C suffix to model number or order part number 412-59586-G separately. Dimensions: 8.5" x 4.5" x 2.4" (215.9 x 114.3 x 61.0 mm) For convection cooled applications with covers, derate output power as follows: Derate all multiple output models and MAP130-1005 to 120 watts. Derate MAP130-1012 and MAP130-1024 to 140 watts. 8 MAP130-1005 meets Class A, radiated. 9 MAP130-1005, MAP130-4003, and MAP130-4010, meet level 2, ±1kV. 10 External airflow of minimum 23 CFM used in ambient over 25 C.

CONNECTOR Input & Output Connections Power Fail Connections Chassis CONDITIONS / DESCRIPTION 6-32 screw wire clamps on 0.312" (7.9 mm) centers, 0.045" (1.1 mm) square pins on 0.156" (3.96 mm) centers, Mates with Molex series 2139, 6442 & 41695 0.035" (0.89 mm) square pins on 0.100" (2.54 mm) centers; Mates with Molex series 2695 & 6471 0.090" (2.286 mm) aluminum alloy with clear finish Figure-1 - Mechanical Drawing NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.