Comparison of resolution specifications for micro- and nanometer measurement techniques

Similar documents
SENSOR+TEST Conference SENSOR 2009 Proceedings II

Surface Finish Measurement Methods and Instrumentation

Manufacturing Metrology Team

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Profile Measurement of Resist Surface Using Multi-Array-Probe System

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

Three-dimensional quantitative phase measurement by Commonpath Digital Holographic Microscopy

Optical Characterization and Defect Inspection for 3D Stacked IC Technology

PROCEEDINGS OF SPIE. Measurement of low-order aberrations with an autostigmatic microscope

Advanced Nanoscale Metrology with AFM

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember

Optotop. 3D Topography. Roughness (Ra opt, Rq opt, and Rz opt) Height Distribution. Porosity Distribution. Effective Contact Area

Multispectral Image Capturing System Based on a Micro Mirror Device with a Diffraction Grating

Microscopic Structures

HIGH-RESOLUTION FIBER-COUPLED INTERFEROMETRIC POINT SENSOR FOR MICRO- AND NANO-METROLOGY. Markus Schake, Markus Schulz and Peter Lehmann ABSTRACT

Heisenberg) relation applied to space and transverse wavevector

Fabrication of Probes for High Resolution Optical Microscopy

Test procedures Page: 1 of 5

An Optical Characteristic Testing System for the Infrared Fiber in a Transmission Bandwidth 9-11μm

Sensitive measurement of partial coherence using a pinhole array

A novel tunable diode laser using volume holographic gratings

Sensitivity Enhancement of Bimaterial MOEMS Thermal Imaging Sensor Array using 2-λ readout

NSOM (SNOM) Overview

Investigate in magnetic micro and nano structures by Magnetic Force Microscopy (MFM)

DIMENSIONAL MEASUREMENT OF MICRO LENS ARRAY WITH 3D PROFILOMETRY

Coherence radar - new modifications of white-light interferometry for large object shape acquisition

EVALUATION OF A FOCUSED LASER SPOT DIAMETER FOR AN OPTICAL ANGLE SENSOR. Yuki Shimizu, Taiji Maruyama, Shota Nakagawa, Yuan-Liu Chen, Wei Gao

Applications of Optics

Optics and Lasers. Matt Young. Including Fibers and Optical Waveguides

Study of shear force as a distance regulation mechanism for scanning near-field optical microscopy

Investigation of an optical sensor for small angle detection

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

A New Profile Measurement Method for Thin Film Surface

Near-field Optical Microscopy

Optical design of a high resolution vision lens

Modifications of the coherence radar for in vivo profilometry in dermatology

Development of innovative fringe locking strategies for vibration-resistant white light vertical scanning interferometry (VSI)

Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry

Prepare Sample 3.1. Place Sample in Stage. Replace Probe (optional) Align Laser 3.2. Probe Approach 3.3. Optimize Feedback 3.4. Scan Sample 3.

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

The spectral colours of nanometers

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

Effects of spherical aberrations on micro welding of glass using ultra short laser pulses

Comparison of FRD (Focal Ratio Degradation) for Optical Fibres with Different Core Sizes By Neil Barrie

Basic methods in imaging of micro and nano structures with atomic force microscopy (AFM)

ATOMIC FORCE MICROSCOPY

Kit for building your own THz Time-Domain Spectrometer

1.6 Beam Wander vs. Image Jitter

Atomic Force Microscopy (Bruker MultiMode Nanoscope IIIA)

Bringing Answers to the Surface

Optical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH

A 3D Profile Parallel Detecting System Based on Differential Confocal Microscopy. Y.H. Wang, X.F. Yu and Y.T. Fei

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Measurement of the Modulation Transfer Function (MTF) of a camera lens. Laboratoire d Enseignement Expérimental (LEnsE)

Supplementary Figure S1. Schematic representation of different functionalities that could be

Uncertainty in measurements of micro-patterned thin film thickness using Nanometrological AFM - Reliability of parameters for base straight line -

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

SPRAY DROPLET SIZE MEASUREMENT

Numerical simulation of a gradient-index fibre probe and its properties of light propagation

TechNote. T001 // Precise non-contact displacement sensors. Introduction

Measuring chromatic aberrations in imaging systems using plasmonic nano particles

AN ANALYSIS OF THE METROLOGY TECHNIQUES TO IMPROVE QUALITY AND ACCURACY

Confocal Microscopy and Related Techniques

Lecture 20: Optical Tools for MEMS Imaging

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

Large Field of View, High Spatial Resolution, Surface Measurements

Miniaturisation, advanced highperformance

Shaping light in microscopy:

1 Introduction. Research Article

Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.

Metrology challenges for highly parallel micro-manufacture

PHYSICS FOR THE IB DIPLOMA CAMBRIDGE UNIVERSITY PRESS

Chapters 1 & 2. Definitions and applications Conceptual basis of photogrammetric processing

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

Diffraction lens in imaging spectrometer

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

NanoSpective, Inc Progress Drive Suite 137 Orlando, Florida

PROCEEDINGS OF SPIE. Measurement of the modulation transfer function (MTF) of a camera lens

XY-stage for alignment of optical elements in MOEMS

RECENTLY, using near-field scanning optical

ADALAM Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing D2.2. Ger Folkersma (Demcon)

Confocal principle for macro- and microscopic surface and defect analysis

ECEN 4606, UNDERGRADUATE OPTICS LAB

FRAUNHOFER INSTITUTE FOR PHOTONIC MICROSYSTEMS IPMS. Application Area. Quality of Life

Basics of INTERFEROMETRY

Lecture 2: Geometrical Optics. Geometrical Approximation. Lenses. Mirrors. Optical Systems. Images and Pupils. Aberrations.

Study of self-interference incoherent digital holography for the application of retinal imaging

Applied Optics. , Physics Department (Room #36-401) , ,

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications

A broadband achromatic metalens for focusing and imaging in the visible

In-line digital holographic interferometry

FemtoFAB. Femtosecond laser micromachining system. tel fax Konstitucijos ave. 23C LT Vilnius, Lithuania

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1

REAL TIME THICKNESS MEASUREMENT OF A MOVING WIRE

AgilOptics mirrors increase coupling efficiency into a 4 µm diameter fiber by 750%.

Chapter Ray and Wave Optics

Measuring Procedure the Principle. The laser beam is scanned by means of a specialized measuring tip within a 3D measurement cylinder.

Figure for the aim4np Report

VC 11/12 T2 Image Formation

Transcription:

P4.5 Comparison of resolution specifications for micro- and nanometer measurement techniques Weckenmann/Albert, Tan/Özgür, Shaw/Laura, Zschiegner/Nils Chair Quality Management and Manufacturing Metrology (QFM) University Erlangen-Nuremberg Naegelsbachstrasse 25 D-91052 Erlangen Germany Tel: +49 9131 8526540 Fax: +49 9131 8526524 qfm@qfm.uni-erlangen.de In most of the measurement tasks of micro- and nanotechnology, a high resolution of the instrument is required. However in most cases, resolution specification of the manufacturer could not be verified due to the lack of an acceptance test for the experimental investigations. In many cases, specification of the resolution is directly taken from the manufacturing specifications, which are mostly theoretically calculated values and do not always represent the real performance of the system. Instrument specific influencing factors, like the noise of data or the effect of optics are also needed to be considered during the investigation of real resolution performance. Because of this, it is required not only to develop calibration and testing tools but also to apply specific acceptance tests. In this article, results of the application of a Siemens-Star to investigate lateral resolution of different instruments are presented. Different surface measurement techniques such as white light interferometer, atomic force microscope and chromatic sensor are used as measurement devices. Results are compared not only with each other but also with manufacturer specifications. By this, the application of calibration and testing equipments for the investigation of resolution specifications is demonstrated. Keywords: Micro- and Nanotechnology, resolution, surface measurement, practice-oriented 1 Introduction Advances in micro- and nanotechnology show that, without understanding the product details and describing them quantitatively, it is not possible to develop them further. Measurements of such products give the required information [1]. One of the important requirements while choosing a measurement device is the suitability of its resolution. But the problem to choose a right resolution is the lack of information about the specification of the resolution. The fundamental definition has been given in DIN 1319-1 as smallest detectable difference between two indications on a displaying device [2]. Since this is a general definition, there are different ways to calculate it. In some cases, resolution specifications depend on very theoretical methods; such as Sparrow or Rayleigh criteria or in other cases, such as dividing the field of a view by the number of pixels does not represent the real resolution performance. Real resolution capacity depends on other factors like quality of optics, noise of data and etc. Another important restriction in optical measurements, which also has to be taken into account, is the dependency of lateral resolution power on the wavelength of the light and the numerical aperture of the lens. Although this definition of diffraction limited resolution has been mostly used in community of microscopy, it is not an accepted definition in most other fields. It could be said that there is not any agreed way to specify lateral resolution for the areal measurement techniques. In this study we have presented an application of a concept from macro techniques in the field of microand nanometrology. Different types of Siemens-Star structures are investigated with different measurement instruments. 2 Testing Tool: Siemens-Star In classical image processing applications, Siemens-Stars which have equal number of dark and white structures (mostly 32) are used to investigate the resolution of cameras. These structures have an alternating width in radial direction. They seem like they touch each other, but the only place where they really intersect is the centre of star (see figure 1). Application of these structures has been modified and applied to the investigation of lateral resolution of measurement devices in micro- and nanotechnologies. The dark and white colours, which are shown in figure 1, are substituted with grooves which have a constant depth value. The circumference of this ambiguous region, which can be seen in the middle of SENSOR+TEST Conference 2009 - SENSOR 2009 Proceedings II 377

structure, gives information about the resolution performance of the instrument. The equation to calculate the number of the resolution is given as the following. Figure 1: A Siemens-Star for the evaluation of resolution of optical instruments If the total number of these structures is n and the diameter of this ambiguous region is D, lateral resolution can be calculated as follow: Lateral Resolution = "! D n Technique of Focus Ion Beam (FIB) is applied to make the structures on the surface. Two different types of stars are investigated. In the first part of the measurements, 5 different stars with a diameter of 60 µm and a step height of 200 nm are measured. In the second part a star with a diameter of 100 µm and the same step height has been investigated. This idea has been used not only in measurement of camera resolutions [3] but also during the investigation of new measurement techniques, like [4]. 3 Measurement Principles In order to compare the lateral resolution of different measurement principles, techniques of white light interferometry, chromatic aberration and atomic force microscopy are investigated. White light interferometer (WLI): Due to its high vertical resolution, WLI has been accepted as an important tool for surface topography measurements. A beam splitter separates the light coming from the source into two beams. One of the beams reaches to the object and the other to the reference (see figure 2). The Mireau objective is driven by a linear actuator element along the optical axis. During the movement in vertical direction, the intensity of the reflected light is stored for each pixel in the CCD element. The measurement region depends on the working distance of the actuator. The maximum of intensity modulation in the interference correlogram occurs at a position where the distance to the measuring object is equal to the distance to the reference surface. This maximum is evaluated to get the height data of the test sample at a certain point. Finally, the height data together with the corresponding lateral coordinates give the topography of the surface. Figure 2: Principles of WLI (left) and CWL (right) 378 SENSOR+TEST Conference 2009 - SENSOR 2009 Proceedings II

In this work a state-of-the-art white light interferometer (Taylor Hobson CCI 1000) with three different objectives has been used to measure the Siemens-Stars. It has a vertical resolution of 0.01 nm with a vertical working range of 400 µm. The main disadvantage of used WLI compared to AFM measurements is that, being an optical technique, the lateral resolution is limited to around 0.35)m. Chromatic White Light Sensor: The measurement principle of the second sensor is based on the chromatic aberration of white light. The refractive index of the front lens in the sensor head changes for different wavelengths of light. As the focus length of the lens depends on the refractive index, a lens with a strong chromatic aberration will show the focus point of the different wavelengths at different positions along the optical axis (see figure 2). This effect, the longitudinal chromatic aberration, is the measurement principle applied in the chromatic sensor. White light, which is passed through a passive lens, is separated into different coloured focal points and focused on the sample. The intensity of the reflected light is evaluated with a spectrometer. As the wavelength which was focused on the sample surface has the maximum intensity, the distance between the sensor and the sample surface can be determined on the basis of comparison tables. The measuring range in z-axis is equal to the distance from blue and red focus point, of 300 µm. The vertical resolution over the z range of the sensor is 10 nm. With the chromatic sensor surface structures up to 2 µm (effective spot diameter of the white light) can be resolved. Atomic Force Microscope (AFM): In general it can be said that AFMs are primarily designed to measure surface topography with a very high spatial resolution. A fine tip at the end of a cantilever for the investigation of the sample surface, a feedback sensor which detects small changes of the tip or cantilever position, a z scanner which keeps the probe under constant conditions (i.e. force) and a xy scanner to displace the tip are the main components of AFMs. Figure 3: Measuring Principle of Atomic Force Microscope The cantilever with a sharp tip, mounted on the end of the piezo scanning tube, is moved towards the surface and when it is very close (a few tens of nanometers) the surface forces result in an interaction between the surface and the tip. The main modes for operating an AFM are contact and non-contact. In the contact mode the cantilever is scanned across the surface and repulsive surface forces cause a bending of the cantilever. In the dynamic non-contact mode the cantilever is oscillated close to its resonant frequency above the surface. As seen in figure 3, to detect the position of the cantilever, light from a laser diode is, through a fiber-optic cable, led to the sensor head. The light reflects from two planes, the planar end of the fibre (reference beam) and the upper side of the cantilever (object beam). The resulting interference signal is detected by a photodiode at the end of the optical fibre. When the distance between the cantilever and the optical fibre is changing, the resulting change in interference signal can be used as the input to a feedback system that ensures the force between the sample and tip (and hence distance) is kept constant. Restrictions in z-measurement range and the needed measurement time could be seen as the main disadvantages. The AFM, which is used in this work, allows a scanning range in the xy axis of 80 80 µm with a lateral resolution of 5 nm. In the z-axis the measuring range is limited to 6 µm. SENSOR+TEST Conference 2009 - SENSOR 2009 Proceedings II 379

4 Measurements with Siemens-Star 4.1 Experiments with WLI Three different objectives have been used for this study. As seen in table 1, not only the theoretical values of objectives are given (dividing field of view by the number of pixels), but also the physical limits to resolution namely, numerical apertures are shown. Additionally optical resolution of the systems, which are calculated with Sparrow criteria ( % $ 570 # nm ), are listed. Table 1: Overview of objectives that have applied for the investigations Objectives Lateral Resolution in µm Numerical Aperture Opt. lateral resolution in µm 10 X 1.76 0.3 0.95 20 X 0.88 0.4 0.71 50 X 0.35 0.55 0.52 In figure 4, measurement of star Nr. 1 with three different objectives can be seen. Before the presentation of any further results, it is clear that, as the resolution decreases, size of the ambiguous region increases. Figure 4: Measurement of ambiguous region with different objectives Using the ambiguous regions diameter, the resolution has been calculated according to the method described above and the results are shown in table 2. Table 2: Experimental calculated resolutions Number of Resolution 10 X objective star in µm 1 2 3 4 5 1.94 2.04 1.82 1.91 1.88 Resolution 20 X objective in µm 0.98 0.96 1.04 1.04 1.09 Resolution 50 X objective in µm 0.55 0.55 0.47 0.47 0.54 Although the applied evaluating system does not have rigid and objective criteria to find out the dimameter, the calculated values are stable for each objective and the variations of the obtained resolution within different stars are reasonable. This shows the high quality of the fabrication of stars. All the calculated results are larger than the specified values, which also show the need for such a practice oriented method in order to get information about the resolution performance of different instruments. Due to the diffraction limited resolution, results of 50 X objective show the largest percentage differences in comparison to the values which are specified by the manufacturer. From these results, it is also clear that, diffraction limited resolution plays a decisive role especially at high magnifying objectives and it is not enough to give the number of pixel per field of view. 4.2 Experiments with AFM Experiments are performed in the non-contact mode with a measurement range of 80 µm 80 µm while capturing 512 points per line. The Cantilever which is used has a diameter smaller than 8 nm. As seen in figure 5, the details of the ambiguous region are resolved, which could not be possible with other systems. In other words, the limits of manufacturing technology of this star are seen. After having 380 SENSOR+TEST Conference 2009 - SENSOR 2009 Proceedings II

calculated this region, it is found to be 0.45 µm. That means, resolution capacity of instruments whose resolutions are higher than this value could not be properly investigated. Figure 5: Measurement of Siemens-Stern with AFM 4.3 Experiments with CWL In comparison to other instruments, CWL has a low lateral resolution. Because of this reason, a Siemens star with a larger diameter (100µm) has been used. As a comparison, the same star has been also investigated with AFM. Due to the limited range of AFM (80 µm 80 µm), the whole star could not be measured. But the ambiguous region has been measured without any difficulties. Figure 6: Measurement of the same Siemens-Star with a) CWL and b) AFM Although the star has a lager diameter (100µm), structures of the CWL measurement could not be seen clearly. On the other hand, structures are clearly seen with AFM, which shows the reliability of the manufacturing method. In order to find out the possible reasons for the explanation of unclear images of CWL, further investigations need to be fulfilled. Ignoring the unclear areas and using the height information from CWL measurements, the resolution is calculated about 3.5 µm. But this is the lower limit, because the disregarded aliasing effect is another important factor for the real resolution capacity. 5 Discussions The concept of Siemens-Star, which is well-known in the field of image processing, has been applied to macro applications. Two different parts of experiments have been performed. In the first one, a comparison of resolution specifications given by manufacturer with experimental obtained resolutions has been done. Results show that, real resolution capacity of instruments is typically worse than theoretically calculated values. In the second part, not only the manufacturing limitation of such structures has been found out by AFM measurements, but also the problems encountered by the application of this technique to CWL have been shown. Other important information from AFM measurements is that, the ambiguous region in WLI measurements is not restricted by the manufacturing limitations but by the resolution performance of the instrument. It is also important to notice that, due to 32 separate branches the manufacturing tolerance is averaged by the number of the branches. For further investigations, a quite wide range of resolution values can be investigated with the same structure. Acknowledgments: The research and development project was funded by German Research Foundation (DFG) and has been carried out by the program of emphasis 1159 New strategies for measurement and test techniques for production of microsystems and nanostructures. Project: Mikro-Nano Messunsicherheit (We 918/273). SENSOR+TEST Conference 2009 - SENSOR 2009 Proceedings II 381

6 Literature [1] Weckenmann, A.; Heidemann, L.; Tan, Ö.; Wiedenhoefer, Th.; Multisensor metrology for nanostructured technical surfaces; XII. Internationales Oberflächenkolloquium;2008; Chemnitz; P.218 227 [2] DIN 1319 1:1995-01, Basic Concepts in metrology [3] Loebich, C.; Wueller, D.; Klingen, B.; Jaeger,A.; Digital Camera Resolution Measurement Using Sinusoidal Siemens Stars, SPIE, Vol. 6502, 65020N (2007); DOI:10.1117/12.703817 [4] Früke, R.; 2005 Würzburg, Entwicklung eines Rastermikroskopes für den Einsatz an Laborquellen im EUV Spektralbereich, Doktorarbeit, Bayerischen Julius-Maximilians-Universität Würzburg 382 SENSOR+TEST Conference 2009 - SENSOR 2009 Proceedings II