SECTION INTERIOR FINISH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Similar documents
B. Related Requirements: 1. Section "Interior Painting" for priming and backpriming of interior finish carpentry.

SECTION INTERIOR FINISH CARPENTRY. A. Lumber grading agencies, and the abbreviations used to reference them, include the following:

SECTION INTERIOR FINISH CARPENTRY

DIVISION 6 WOODS AND PLASTICS SECTION FINISH CARPENTRY

ADDENDUM NO. 1 THOROUGHBRED ROOM RENOVATION PHASE II DINING AREA MURRAY STATE UNIVERSITY, MURRAY, KY PROJECT #

A. Boards or Strips: Lumber of less than 2 inches nominal size in least dimension.

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Ash Brook Golf Course Scotch Plains, New Jersey

SECTION FINISH CARPENTRY

A. Provide all finish carpentry needed for a complete and proper installation.

SECTION MISCELLANEOUS ROUGH CARPENTRY

A. All trim that has been damages, broken, or missing shall be repaired or replaced with material of the same size, shape, and type.

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

FT DIX ELEMENTARY SCHOOL PHASE VII, CLASSROOM ADDITION PEMBERTON TOWNSHIP REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5349A

Project Specifications Section SECTION ROUGH CARPENTRY Issued Final:

D. Product Certificates: Signed by manufacturers of casework certifying that products furnished comply with requirements.

Multi-Institutional Academic Health Science & Research Center Evansville, IN

DIVISION 6 WOODS AND PLASTICS SECTION ROUGH CARPENTRY

Lindenwold Boro Hall Lindenwold, NJ. Bishop & Smith Architects Laurel Springs, NJ. August 2, 2012 PART 1 - GENERAL 1.1 SUMMARY. A.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS

2. Wood grounds, nailers, blocking, miscellaneous framing, sleepers, etc.

SECTION ARCHITECTURAL WOOD CASEWORK

DIVISON 6 WOODS AND PLASTICS SECTION PLASTIC LAMINATE FACED ARCHITECTUAL CABINETS

SECTION FINISH CARPENTRY PART 1 GENERAL. 1.1 SECTION INCLUDES A. Interior Finish Carpentry Work: 1. Refer to schedule at end of Section.

Student Services & Classroom Addition

WHITE W/OAK TRIM NATURAL MEDIUM NORTHPORT OAK

SECTION ROUGH CARPENTRY

SECTION CARPENTRY

SECTION INTERIOR ARCHITECTURAL WOODWORK

SECTION ROUGH CARPENTRY

E.M. Crouthamel Elementary School SECTION ROUGH CARPENTRY

A. Dimension Lumber: Lumber of 2 inches nominal or greater but less than 5 inches nominal in least dimension.

SECTION PLASTIC-LAMINATE-FACED ARCHITECTURAL CABINETS

DIVISION 6 WOOD AND PLASTICS

PART 1 GENERAL FINISH CARPENTRY

SECTION ARCHITECTURAL WOODWORK

OCCE Courtroom Built-in SSA Jacksonville, NC

SECTION WOOD ARCHITECTURAL CABINETS AND LAMINATE COUNTERTOPS

ADDENDUM TO THE CONTRACT. for the GLACIER FIRE STATION KITCHEN AND CLASSROOM RENOVATION. Contract No. E16-181

A. Dimension Lumber: Lumber of 2 inches nominal (38 mm actual) or greater but less than 5 inches nominal (114 mm actual) in least dimension.

B. Shop Drawings: For residential casework. Include plans. elevations, details, and attachments to other work.

SECTION ROUGH CARPENTRY

INTEX Millwork Solutions SECTION EXTERIOR PVC PERGOLAS (IBC Compliant)

A. Dimension Lumber: Lumber of 2 inches nominal or greater but less than 5 inches nominal in least dimension.

Product Guide Specification For Nonrated & 20-Minute Rated Doors

SECTION INTERIOR ARCHITECTURAL WOODWORK

A. Rough carpentry includes but is not limited to the following:

SECTION ARCHITECTURAL WOODWORK. B. Related Sections: 1. Section Paints and Coatings: Field applied painted finishes.

1. Division 6 Section "Rough Carpentry" for furring, blocking, and other carpentry work that is not exposed to view.

SECTION WOOD ARCHITECTURAL CABINETS AND QUARTZ COUNTERTOPS

SECTION WOOD DOORS

SECTION INTERIOR ARCHITECTURAL WOODWORK

The City of Winnipeg Section St. Vital Park Pavilion Page 1 of 1

On-Call General Contractor Specifications University of Maryland College Park June 2013

ADDENDUM TO BID DOCUMENTS ADDENDUM #03 SCCD RFP: # Project: Solano Community College District Vacaville Classroom Building (Annex) Renovation

RAMAPO COLLEGE OF NEW JERSEY PHASE II HOUSING REHABILITATION 2012

A. Product Data: For each type of product indicated cabinet hardware and accessories, and finishing materials and processes.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 06 WOOD, PLASTICS AND COMPOSITES

A. Work of this Section, as shown or specified, shall be in accordance with the requirements of the Contract Documents.

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

DIVISION 6 WOOD, PLASTICS AND COMPOSITES

SECTION FINISH CARPENTRY

SECTION ROUGH CARPENTRY 1.1 DESCRIPTION OF WORK:

Music Area Casework General 1.01 Summary Related Sections Definitions Qualifications and Quality Assurance

A. Product Data: For each type of process and factory-fabricated product indicated.

1.04 QUALITY ASSURANCE

SECTION INTERIOR ARCHITECTURAL WOODWORK. A. Section includes interior woodwork items indicated not specified elsewhere and as specified.

SECTION PRE-MANUFACTURED CABINETS

A. Product Data: For each type of process and factory-fabricated product. a. Include statement indicating costs for each certified wood product.

ROWAN COUNTY AIRPORT APRIL 2017 TERMINAL EXPANSION

SECTION MANUFACTURED CASEWORK

NATURAL TOFFEE SABLE SEDONA KONA SENECA RIDGE MAPLE

Coliseum and Women's Building Interior/Exterior Improvements and Campground Utility Improvements Project# F

DETAILED STILE AND RAIL WOOD DOOR SPECIFICATION

SECTION WOOD AND PLASTIC DOORS. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION ROUGH CARPENTRY

1. Section : Rough Carpentry 2. Section : Exterior Insulation and Finishing Systems 3. Section : Metal Roof Panels

B. Related Sections: The following Sections contain requirements that relate to this Section:

A. This Section includes interior architectural woodwork items indicated on Drawings and specified in this Section.

SECTION CUSTOM CASEWORK

Technical Data VARIABLES

RIVERSIDE MEDICAL CENTER 5/09

SECTION INTERIOR ARCHITECTURAL WOODWORK

SECTION ROUGH CARPENTRY


Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

TECHNICAL STANDARDS SECTION

SECTION CUSTOM CABINETS

1.03 QUALITY ASSURANCE A. Inspection Agencies: 1. SPIB: Southern Pine Inspection Bureau; for all structural framing of roof joists and headers.

Section "Rough Carpentry" for wood blocking for anchoring laboratory casework.

A. Section includes surface preparation and the application of paint systems on the following exterior substrates: 1. Steel and iron.

Copyright 2017 AIA MasterSpec Premium 05/17 PRODUCT MASTERSPEC LICENSED BY ARCOM TO WEREVER PRODUCTS, INC.

SECTION 06130: TIMBER FRAMING MASTER SPECIFICATION (VERSION 85/2431/2011)

LIBERTY STATION Heber City, UT

ENDUREED VIVA SERIES Specifications

B. Related Sections: The following Sections contain requirements that relate to this Section:

SECTION ARCHITECTURAL WOOD CASEWORK

WOOD WOOD

B. Shop Drawings: For horizontal louver blinds, include fabrication and installation details.

ROANOKE ISLAND AQUARIUM TURTLE REHABILITATION CENTER SECTION ROUGH CARPENTRY PART 1 - GENERAL

Transcription:

SECTION 062023 - INTERIOR FINISH CARPENTRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Interior trim. 2. Interior plywood mounting boards. 3. Interior backer firring for raceway mounting. 1.3 ACTION SUBMITTALS A. Product Data: For each type of process and factory-fabricated product. Indicate component materials, dimensions, profiles, textures, and colors and include construction and application details. 1. Include data for wood-preservative treatment from chemical-treatment manufacturer and certification by treating plant that treated materials comply with requirements. Indicate type of preservative used and net amount of preservative retained. Include chemicaltreatment manufacturer's written instructions for finishing treated material. 2. Include data for fire-retardant treatment from chemical-treatment manufacturer and certification by treating plant that treated materials comply with requirements. 3. For products receiving a waterborne treatment, include statement that moisture content of treated materials was reduced before shipment to Project site to levels specified. 4. Include copies of warranties from chemical-treatment manufacturers for each type of treatment. B. Samples for Initial Selection: For each type of product involving selection of colors, profiles, or textures. C. Samples for Verification: 1. For each species and cut of lumber and panel products with non-factory-applied finish, with 1/2 of exposed surface finished, 50 sq. in. for lumber and 8 by 10 inches for panels. 1.4 INFORMATIONAL SUBMITTALS A. Evaluation Reports: For fire-retardant-treated wood, from ICC-ES. B. Sample Warranty: For manufacturer's warranty. INTERIOR FINISH CARPENTRY 062023-1

1.5 DELIVERY, STORAGE, AND HANDLING A. Stack lumber, plywood, and other panels flat with spacers between each bundle to provide air circulation. Protect materials from weather by covering with waterproof sheeting, securely anchored. Provide for air circulation around stacks and under coverings. B. Deliver interior finish carpentry materials only when environmental conditions meet requirements specified for installation areas. If interior finish carpentry materials must be stored in other than installation areas, store only where environmental conditions meet requirements specified for installation areas. 1.6 FIELD CONDITIONS A. Environmental Limitations: Do not deliver or install interior finish carpentry materials until building is enclosed and weatherproof, wet work in space is completed and nominally dry, and HVAC system is operating and maintaining temperature and relative humidity at occupancy levels during the remainder of the construction period. B. Do not install finish carpentry materials that are wet, moisture damaged, or mold damaged. 1. Indications that materials are wet or moisture damaged include, but are not limited to, discoloration, sagging, or irregular shape. 2. Indications that materials are mold damaged include, but are not limited to, fuzzy or splotchy surface contamination and discoloration. 1.7 WARRANTY A. Manufacturer's Warranty for Columns: Manufacturer agrees to repair or replace columns that fail in materials or workmanship within specified warranty period. 1. Warranty Period for Columns: Five years from date of Substantial Completion. PART 2 - PRODUCTS 2.1 MATERIALS, GENERAL A. Regional Materials: The following wood products shall be manufactured within 500 miles of Project site from materials that have been extracted, harvested, or recovered, as well as manufactured, within 500 miles of Project site. 1. Interior trim (includes raceway backer material). 2. Interior plywood (equipment mounting boards). B. Low-Emitting Materials: Composite wood products shall comply with the testing and product requirements of the California Department of Health Services' "Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers." C. Softwood Plywood: DOC PS 1. D. Hardboard: AHA A135.4. INTERIOR FINISH CARPENTRY 062023-2

E. MDF: ANSI A208.2, Grade 130, made with binder containing no urea-formaldehyde resin. F. Melamine-Faced Particleboard: Particleboard complying with ANSI A208.1, Grade M-2, finished on both faces with thermally fused, melamine-impregnated decorative paper and complying with requirements of NEMA LD3, Grade VGL, for test methods 3.3, 3.4, 3.6, 3.8, and 3.10. 1. Color: As selected by engineer from manufacturer's full range. 2.2 FIRE-RETARDANT-TREATED MATERIALS (PLYWOOD EQUIPMENT BACKER BOARDS) A. General: For applications indicated, use materials complying with requirements in this article that are acceptable to authorities having jurisdiction, and comply with testing requirements; testing by a qualified testing agency. B. Fire-Retardant-Treated Lumber and Plywood by Pressure Process: Products with a flamespread index of 25 or less when tested according to ASTM E 84, with no evidence of significant progressive combustion when the test is extended an additional 20 minutes, and with the flame front not extending more than 10.5 feet beyond the centerline of the burners at any time during the test. 1. Kiln dry lumber and plywood after treatment to a maximum moisture content of 19 and 15 percent respectively. C. For exposed items indicated to receive a stained or natural finish, use organic resin chemical formulations that do not contain colorants, and provide materials that do not have marks from spacer sticks on exposed face. D. Do not use material that does not comply with requirements for untreated material or is warped or discolored. E. Identify fire-retardant-treated wood with appropriate classification marking of testing and inspecting agency acceptable to authorities having jurisdiction. 1. For exposed lumber indicated to receive a stained or natural finish, mark end or back of each piece. 2. For exposed plywood indicated to receive a stained or natural finish, mark back of each piece. 2.3 INTERIOR TRIM (INCLUDING RACEWAY BACKER) A. Hardwood Lumber Trim for Transparent Finish (Stain or Clear Finish): 1. Species and Grade: Red oak; Clear; NHLA. 2. Maximum Moisture Content: 10 percent. 3. Finger Jointing: Not allowed. 4. Gluing for Width: Not allowed. 5. Veneered Material: Not allowed. 6. Face Surface: Surfaced (smooth). 7. Matching: Selected for compatible grain and color. B. Lumber Trim for Opaque Finish (Painted Finish): INTERIOR FINISH CARPENTRY 062023-3

1. Species and Grade: Eastern white pine, D Select; NeLMA or NLGA. 2. Maximum Moisture Content: 15 percent with at least 85 percent of shipment at 12 percent or less. 3. Finger Jointing: Allowed. 4. Face Surface: Surfaced (smooth). 5. Optional Material: Primed MDF of same actual dimensions as lumber indicated may be used in lieu of lumber. 2.4 MISCELLANEOUS MATERIALS A. Fasteners for Interior Finish Carpentry: Nails, screws, and other anchoring devices of type, size, material, and finish required for application indicated to provide secure attachment, concealed where possible. B. Low-Emitting Materials: Adhesives shall comply with the testing and product requirements of the California Department of Health Services' "Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers." C. Glue: Aliphatic-resin, polyurethane, or resorcinol wood glue recommended by manufacturer for general carpentry use. 1. Wood glue shall have a VOC content of 30 g/l or less when calculated according to 40 CFR 59, Subpart D (EPA Method 24). D. Paneling Adhesive: Comply with paneling manufacturer's written recommendations for adhesives. 1. Adhesive shall have a VOC content of 50 g/l or less when calculated according to 40 CFR 59, Subpart D (EPA Method 24). E. Multipurpose Construction Adhesive: Formulation complying with ASTM D 3498 that is recommended for indicated use by adhesive manufacturer. 1. Adhesive shall have a VOC content of 70 g/l or less when calculated according to 40 CFR 59, Subpart D (EPA Method 24). PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance. B. Examine finish carpentry materials before installation. Reject materials that are wet, moisture damaged, and mold damaged. C. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Clean substrates of projections and substances detrimental to application. INTERIOR FINISH CARPENTRY 062023-4

B. Before installing interior finish carpentry, condition materials to average prevailing humidity in installation areas for a minimum of 24 hours. 3.3 INSTALLATION, GENERAL A. Do not use materials that are unsound, warped, improperly treated or finished, inadequately seasoned, too small to fabricate with proper jointing arrangements, or with defective surfaces, sizes, or patterns. B. Install interior finish carpentry level, plumb, true, and aligned with adjacent materials. Use concealed shims where necessary for alignment. 1. Scribe and cut interior finish carpentry to fit adjoining work. Refinish and seal cuts as recommended by manufacturer. 2. Where face fastening is unavoidable, countersink fasteners, fill surface flush, and sand unless otherwise indicated. 3. Install to tolerance of 1/8 inch in 96 inches for level and plumb. Install adjoining interior finish carpentry with 1/32-inch maximum offset for flush installation and 1/16-inch maximum offset for reveal installation. 4. Coordinate interior finish carpentry with materials and systems in or adjacent to it. Provide cutouts for mechanical and electrical items that penetrate interior finish carpentry. 3.4 ADJUSTING A. Replace interior finish carpentry that is damaged or does not comply with requirements. Interior finish carpentry may be repaired or refinished if work complies with requirements and shows no evidence of repair or refinishing. Adjust joinery for uniform appearance. 3.5 CLEANING A. Clean interior finish carpentry on exposed and semiexposed surfaces. Restore damaged or soiled areas and touch up factory-applied finishes, if any. 3.6 PROTECTION A. Protect installed products from damage from weather and other causes during construction. B. Remove and replace finish carpentry materials that are wet, moisture damaged, and mold damaged. 1. Indications that materials are wet or moisture damaged include, but are not limited to, discoloration, sagging, or irregular shape. 2. Indications that materials are mold damaged include, but are not limited to, fuzzy or splotchy surface contamination and discoloration. END OF SECTION 062023 INTERIOR FINISH CARPENTRY 062023-5