RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Similar documents
RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

RENF22R2MMW Zelio Timer Relay - Modular

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

08/07/2015

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

08/07/2015

02/11/2015

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

02/11/2015

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

RE Product data sheet Characteristics. universal plug-in timing relay V AC - 1 C/O. Main. Complementary. Discrete output type

22/10/2012

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

PART NUMBERING SYSTEM

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

02/11/2015

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

05/09/2012

Zelio Control Measurement Relays

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

02/11/2015

02/11/2015

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ZBRT2 double actions (up/down) transmitter for wireless and battery less pushbutton

Multi-voltage Multi-function. Wiring diagram (without control signal)

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

PART NUMBERING SYSTEM

24/07/2012

11/03/2013

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

83 Series - Modular timers 16 A. Features

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

27/04/2015

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

LXM32AD18M2 motion servo drive - Lexium 32 - single phase supply voltage 115/230V - 0.5/1kW

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw


Type CP-S, CP-C & CP-A Switch mode

Type Nominal voltage (V) Code HSV V

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Solid-state Timer H3DS

83 SERIES. 83 Series - Modular timers A. Features

CP-T range Product group picture

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

Three-phase monitoring relay CM-PFS

Wireless, Batteryless Push Buttons

Modular timers A

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

Electronic timer CT-TGD.22

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

CP-T range Benefits and advantages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Multi-function 11 pin Plug-in for use with 90 series sockets

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Electronic timer CT-MFS.21

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Transcription:

Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Control type [Us] rated supply voltage Voltage range Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal output current Cadmium free Selector switch on front panel 24 V DC 24...240 V AC at 50/60 Hz 0.85...1.1 Us Supply frequency 50...60 Hz (+/- 5 %) Release of input voltage 10 V Zelio Time Modular timing relay Relay 17.5 mm RE17R A At 0.1...1 s 1...10 h 1...10 min 1...10 s 10...100 h 6...60 min 6...60 s Connections - terminals Screw terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16 (flexible) with cable end Screw terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14 (flexible) with cable end Screw terminals, clamping capacity: 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14 (solid) without cable end Screw terminals, clamping capacity: 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12 (solid) without cable end Tightening torque 0.6...1 N.m conforming to IEC 60947-1 Housing material Self-extinguishing Repeat accuracy +/- 0.5 % conforming to IEC 61812-1 Temperature drift Voltage drift +/- 0.05 %/ C +/- 0.2 %/V Setting accuracy of time delay +/- 10 % of full scale at 25 C conforming to IEC 61812-1 Control signal pulse width 8 A 30 ms typical 100 ms with load in parallel typical Insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1 Reset time On-load factor 100 % Power consumption in VA Power consumption in W Minimum switching current Maximum switching current Maximum switching voltage Breaking capacity 120 ms on de-energisation typical <= 32 VA at 240 V AC <= 0.6 W at 24 V DC 10 ma 5 V DC 8 A AC/DC 250 V AC <= 2000 VA The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Oct 14, 2016 1

Operating frequency Electrical durability Mechanical durability 10 Hz 100000 cycles for resistive load (8 A at 250 V AC maximum) 10000000 cycles Dielectric strength 2.5 kv 1 ma/1 minute 50 Hz conforming to IEC 61812-1 [Uimp] rated impulse withstand voltage Power on delay Marking 5 kv (1.2/50 µs) < 100 ms Creepage distance 4 kv/3 conforming to IEC 60664-1 Safety reliability data Mounting position CE MTTFd = 296.8 years B10d = 270000 Any position in relation to normal vertical mounting plane Mounting support 35 mm DIN rail conforming to EN/IEC 60715 Local signalling Product weight LED indicator pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) (5 % ON and 95 % OFF) LED indicator flashing: timing in progress (80 % ON and 20 % OFF) LED indicator on steady: relay energised, no timing in progress 0.07 kg Environment Immunity to microbreaks Standards Product certifications <= 20 ms 2004/108/EC EN 61000-6-1 EN 61000-6-2 EN 61000-6-3 EN 61000-6-4 IEC 61812-1 2006/95/EC CSA CULus GL Ambient air temperature for storage -30...60 C Ambient air temperature for operation -20...60 C IP degree of protection IP50 (front panel) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP20 (terminal block) conforming to IEC 60529 Vibration resistance 20 m/s² (f = 10...150 Hz) conforming to IEC 60068-2-6 Shock resistance 15 gn (duration = 11 ms) conforming to IEC 60068-2-27 Relative humidity 93 % without condensation conforming to IEC 60068-2-30 Electromagnetic compatibility Conducted and radiated emissions conforming to EN 55022 class B Voltage dips and interruptions immunity test, 25/30 cycles at 70 % conforming to IEC 61000-4-11 Voltage dips and interruptions immunity test, 1 cycle at 0 % conforming to IEC 61000-4-11 Conducted RF disturbances, 0.15...80 MHz at 10 V conforming to IEC 61000-4-6 level 3 1.2/50 µs shock waves immunity test, common mode at 2 kv conforming to IEC 61000-4-5 level 3 1.2/50 µs shock waves immunity test, differential mode at 1 kv conforming to IEC 61000-4-5 level 3 Electrical fast transient/burst immunity test, direct at 2 kv conforming to IEC 61000-4-4 level 3 Electrical fast transient/burst immunity test, capacitive connecting clip at 1 kv conforming to IEC 61000-4-4 level 3 Susceptibility to electromagnetic fields, 80 MHz to 1 GHz at 10 V/m conforming to IEC 61000-4-3 level 3 Electrostatic discharge immunity test, in air at 8 kv conforming to IEC 61000-4-2 level 3 Electrostatic discharge immunity test, in contact at 6 kv conforming to IEC 61000-4-2 level 3 Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1243 - Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Product environmental profile Available Download Product Environmental Product end of life instructions Available Download End Of Life Manual 2

Dimensions Drawings Width 17.5 mm 3

Connections and Schema Internal Wiring Diagram Wiring Diagram 4

Technical Description Function A : Power on Delay Relay Description The timing period T begins on energisation. After timing, the output(s) R close(s). The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) Function At : Power on Delay Relay (Summation) with Control Signal Description After power-up, the first opening of control contact C starts the timing. Timing can be interrupted each time control contact closes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output relay closes. Function: 1 Output T = t1 + t2 +... Legend Relay de-energised Relay energised Output open Output closed C G R R1/ R2 R2 inst. T Ta - Tr - U Control contact Gate Relay or solid state output 2 timed outputs The second output is instantaneous if the right position is selected Timing period Adjustable On-delay Adjustable Off-delay Supply 5