Control design issues for a microinvasive neurosurgery teleoperator system

Similar documents
AHAPTIC interface is a kinesthetic link between a human

A Feasibility Study of Time-Domain Passivity Approach for Bilateral Teleoperation of Mobile Manipulator

2. Introduction to Computer Haptics

Performance Issues in Collaborative Haptic Training

FPGA Based Time Domain Passivity Observer and Passivity Controller

Bilateral Delayed Teleoperation: The Effects of a Passivated Channel Model and Force Sensing A. Aziminejad, M. Tavakoli, R.V. Patel, M.

Steady-Hand Teleoperation with Virtual Fixtures

Medical Robotics. Part II: SURGICAL ROBOTICS

Nonlinear Adaptive Bilateral Control of Teleoperation Systems with Uncertain Dynamics and Kinematics

Networked haptic cooperation using remote dynamic proxies

Lecture 6: Kinesthetic haptic devices: Control

Computer Assisted Medical Interventions

Robust Haptic Teleoperation of a Mobile Manipulation Platform

Passive Bilateral Teleoperation

Cutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery

Some Issues on Integrating Telepresence Technology into Industrial Robotic Assembly

Shape Memory Alloy Actuator Controller Design for Tactile Displays

Lecture 9: Teleoperation

Time-Domain Passivity Control of Haptic Interfaces

II. TELEOPERATION FRAMEWORK. A. Forward mapping

Modeling and Experimental Studies of a Novel 6DOF Haptic Device

Enhanced Transparency in Haptics-Based Master-Slave Systems

Elements of Haptic Interfaces

Discrimination of Virtual Haptic Textures Rendered with Different Update Rates

Haptic Virtual Fixtures for Robot-Assisted Manipulation

Cutaneous Force Feedback as a Sensory Subtraction Technique in Haptics

HUMAN Robot Cooperation Techniques in Surgery

Force feedback interfaces & applications

Force display using a hybrid haptic device composed of motors and brakes

AC : MEDICAL ROBOTICS LABORATORY FOR BIOMEDICAL ENGINEERS

Increasing the Impedance Range of a Haptic Display by Adding Electrical Damping

Applying Model Mediation Method to a Mobile Robot Bilateral Teleoperation System Experiencing Time Delays in Communication

Available theses in industrial robotics (October 2016) Prof. Paolo Rocco Prof. Andrea Maria Zanchettin

The Haptic Impendance Control through Virtual Environment Force Compensation

Enhanced performance of delayed teleoperator systems operating within nondeterministic environments

MEAM 520. Haptic Rendering and Teleoperation

FORCE FEEDBACK. Roope Raisamo

MEAM 520. Haptic Rendering and Teleoperation

Methods for Haptic Feedback in Teleoperated Robotic Surgery

Design and Controll of Haptic Glove with McKibben Pneumatic Muscle

Cutaneous haptic feedback to ensure the stability of robotic teleoperation systems

Design and Operation of a Force-Reflecting Magnetic Levitation Coarse-Fine Teleoperation System

A Tactile Magnification Instrument for Minimally Invasive Surgery

Nonholonomic Haptic Display

Andrea Zanchettin Automatic Control 1 AUTOMATIC CONTROL. Andrea M. Zanchettin, PhD Winter Semester, Linear control systems design Part 1

Using Simulation to Design Control Strategies for Robotic No-Scar Surgery

phri: specialization groups HS PRELIMINARY

Chapter 2 Introduction to Haptics 2.1 Definition of Haptics

Motion Control of a Semi-Mobile Haptic Interface for Extended Range Telepresence

Investigation on Standardization of Modal Space by Ratio for MDOF Micro-Macro Bilateral Teleoperation Control System

Bibliography. Conclusion

Haptic Tele-Assembly over the Internet

Mobile Manipulation in der Telerobotik

A Digital Input Shaper for Stable and Transparent Haptic Interaction

Design of an Intermediate Layer to Enhance Operator Awareness and Safety in Telesurgical Systems

Jane Li. Assistant Professor Mechanical Engineering Department, Robotic Engineering Program Worcester Polytechnic Institute

An Experimental Study of the Limitations of Mobile Haptic Interfaces

2B34 DEVELOPMENT OF A HYDRAULIC PARALLEL LINK TYPE OF FORCE DISPLAY

On Observer-based Passive Robust Impedance Control of a Robot Manipulator

Università di Roma La Sapienza. Medical Robotics. A Teleoperation System for Research in MIRS. Marilena Vendittelli

Surgical robot simulation with BBZ console

Exploring Haptics in Digital Waveguide Instruments

Haptics CS327A

Haptic Rendering CPSC / Sonny Chan University of Calgary

CS277 - Experimental Haptics Lecture 2. Haptic Rendering

Stability of Haptic Displays

Novel machine interface for scaled telesurgery

Haptic Effects of Surgical Teleoperator Flexibility

Image Guided Robotic Assisted Surgical Training System using LabVIEW and CompactRIO

CHAPTER 3. Instrumentation Amplifier (IA) Background. 3.1 Introduction. 3.2 Instrumentation Amplifier Architecture and Configurations

Haptic Feedback in Laparoscopic and Robotic Surgery

Information and Program

Model-Mediated Teleoperation for Multi-Operator Multi-Robot Systems

Robotics Manipulation and control. University of Strasbourg Telecom Physique Strasbourg, ISAV option Master IRIV, AR track Jacques Gangloff

Point Cloud-based Model-mediated Teleoperation with Dynamic and Perception-based Model Updating

Haptic Communication for the Tactile Internet

MATLAB is a high-level programming language, extensively

Force Feedback Mechatronics in Medecine, Healthcare and Rehabilitation

Integrating PhysX and OpenHaptics: Efficient Force Feedback Generation Using Physics Engine and Haptic Devices

Continuous Impulsive Force Controller for FRVFs

Proprioception & force sensing

Telemanipulation and Telestration for Microsurgery Summary

Evaluation of Five-finger Haptic Communication with Network Delay

Wireless Robust Robots for Application in Hostile Agricultural. environment.

Application of Levant s Differentiator for Velocity Estimation and Increased Z-Width in Haptic Interfaces

Wireless Master-Slave Embedded Controller for a Teleoperated Anthropomorphic Robotic Arm with Gripping Force Sensing

Evaluation of Haptic Virtual Fixtures in Psychomotor Skill Development for Robotic Surgical Training

high, thin-walled buildings in glass and steel

Booklet of teaching units

Haptic Models of an Automotive Turn-Signal Switch: Identification and Playback Results

Robots Learning from Robots: A proof of Concept Study for Co-Manipulation Tasks. Luka Peternel and Arash Ajoudani Presented by Halishia Chugani

HAPTIC INTERFACE CONTROL DESIGN FOR PERFORMANCE AND STABILITY ROBUSTNESS. Taweedej Sirithanapipat. Dissertation. Submitted to the Faculty of the

Medical Robotics LBR Med

Performance Analysis of Steady-Hand Teleoperation versus Cooperative Manipulation

Stable Teleoperation with Scaled Feedback

An Excavator Simulator for Determining the Principles of Operator Efficiency for Hydraulic Multi-DOF Systems Mark Elton and Dr. Wayne Book ABSTRACT

PHYSICAL ROBOTS PROGRAMMING BY IMITATION USING VIRTUAL ROBOT PROTOTYPES

Future Society Opened by Real Haptics. Kouhei OHNISHI, Yuki SAITO, Satoshi FUKUSHIMA, Takuya MATSUNAGA, Takahiro NOZAKI

TOUCH sensations are essential for many telemanipulation

IEEE/ASME TRANSACTIONS ON MECHATRONICS 1. Vinay Chawda, Student Member, IEEE and Marcia K. O Malley, Senior Member, IEEE

Transcription:

Control design issues for a microinvasive neurosurgery teleoperator system Jacopo Semmoloni, Rudy Manganelli, Alessandro Formaglio and Domenico Prattichizzo Abstract This paper deals with controller design issues for a neurosurgical teleoperator system. The specific application of interest consists in remotely inserting a linearstage rigid endoscope into the patient s brain for microinvasive neurosurgery interventions. This work aims at evaluating the applicability of an existing generalpurpose control architecture, addressing its advantages and drawbacks with respect to a simple taskoriented architecture, specifically designed for the target application. Preliminary experiments revealed that the taskoriented design can better fit the application requirements. I. INTRODUCTION In the last years, the usage of robotic teleoperation systems in the operation room is increasing fast [1]. Among the large variety of applications dealing with this research, in this paper the attention is directed towards microinvasive neurosurgery. This work is part of the project RoboCAST: ROBOt and sensors integration for Computer Assisted Surgery and Therapy [2]. According to the project goals, the telemanipulation system is targeted at driving the insertion of a linearstage rigid endoscope into the brain of the patient for neurosurgery interventions. The endoscope insertion will be assisted by a haptic interface, which will extend and complement the surgeons skills during the insertion process. The device will be responsible for the reproduction and the eventual amplification of the forces experienced by the endeffector linear stage via a force feedback interface onto the surgeons hand. This mechanism will enable the manual servoassisted insertion of the probe into soft tissues without the loss of kinaesthetic perception. In this paper we present preliminary results of our current research, addressed towards the design issues characterizing teleoperation control systems. The goal of a teleoperation controller is to achieve transparency while maintaining stability (i.e., such that the system does not exhibit vibration or divergent behavior), under any operating conditions and for any environments [3], [4], [5], [6]. To this end, the control architectures are designed trading off transparency and stability, since transparency must often be sacrificed in order to guarantee stable operation in the wide range of environment impedances [7], [8]. We remark that we are far from providing a fair comparison between different control architectures available in the literature. The target of this preliminary work was evaluating the possibility to adapt existing control schemes to the application of interest, before undertaking the development of a new specific and taskoriented architecture. After a brief review of the literature, we chose to evaluate the applicability of the TimeDomain Passivity Control (PC) introduced in [9]. Then, we developed a simple taskoriented proportionalderivative (PD) control based on the assumption that the user s commanded motions during a microinvasive neurosurgery intervention will be slow and sharp, thus also the force reflection will be fed back with slow dynamics. Hence, the PD has been designed in order to filter out all surgeons motions exceeding a predefined bandwidth, thus privileging task accuracy and safety in spite of a loss of dynamical performance. The testbed setup was a masterslave system composed by a Omega Haptic Device (master) and a KUKA KR3 robot (slave). We qualitatively evaluated the system performance in three telemanipulation tasks: rigid contact with high stiffness objects, soft contact with a deformable object and finally the insertion of a needle into a perforable material. The results stemming from this preliminary study show that in spite of its simplicity, the taskoriented design fits better the requirements for the application of interest. The remainder of this paper is structured as follows: in Section II we model the teleoperation system, the Section III discusses the adopted control strategies, the Section IV reports experiments and results, and finally the Section V concludes this work. II. MODELING The teleoperator system is modeled as the combination of three subsystems: the master device, the slave device and the controller, as shown in Fig. 1. In the scope of this work, This work was supported by the European Community under Grant FP7 ICT2007215190 RoboCAST. Jacopo Semmoloni, Rudy Manganelli, Alessandro Formaglio each subsystem is modeled as a linear timeinvariant (LTI) and Domenico Prattichizzo are with Department of Information system. Engineering, University of Siena, via Roma 56, 53100 Siena, Italy. semmoloni@gmail.com, manganelli@dii.unisi.it, The master system is the device that the user remotely formaglio@dii.unisi.it, prattichizzo@dii.unisi.ithandles to drive the endoscope insertion, while the slave Fig. 1. The functional scheme of a teleoperator system.

physically performs the task in the operational environment. In this application, the master is the Omega.3 impedance forcefeedback device (ForceDimension), whose technical specifications are reported in Table I. Kinematics Workspace 3D Resolution Stiffness Peak Force Max Continuous Force TABLE I Parallel 3 DoF 160 160 120mm < 0.01mm 15N/mm 12N 12N TECHNICAL SPECIFICATIONS OF THE OMEGA.3 HAPTIC INTERFACE. As already mentioned in the introduction, the final application consists in driving the insertion of a linearstage endoscope, hence the task will feature a single translational DoF. To that end, we chose to mechanically customize the kinematics of the Omega in order to constrain the possible motion only along a single DoF, as shown in Fig. 2. equipped with a 1DoF force sensor, featuring 4 wheatstonebridge strain gauges. The data acquisition setup, including the sensor power supply and a National Instrument 6014 PCI acquisition device, was tuned to measure forces ranging from 12N to 12N, with a resolution of 0.4mN. III. TELEMANIPULATION CONTROL As already mentioned in the introduction, we implemented the timedomain passivity control. Using this approach, the teleoperation system can be modeled as a twoport network as the one depicted in Fig. 3. where the human operator s Fig. 3. network V h F h Teleoperator V e F e Environment The masterslave teleoperation system, modeled as a twoport force F h and the remote environment force F e are the efforts, and the master endeffector velocity V h and the slave endeffectors velocity V e are the flows. The stability of the overall system is then ensured provided that each port is passive, i.e. it does not introduce energy into the system [9]. A passivity observer (PO) is applied to monitor the port energy at each time instant. Assuming that the controller is a discretetime system featuring sample time T c, the PO computes the port energy at the k th time instant as: E PO (k) = E PO (k 1)T c F(k)V(k) Fig. 2. The customized Omega.3 featuring a single translational DoF. The slave device is the anthropomorphic manipulator KUKA KR3. The Table II reports the main technical specifications of the slave robot. The KR3 is a discretetime system Kinematics Workspace 3D Resolution Repeatability Peak Force Max Velocity anthropomorphic 6 DoF Max reach 650mm 0.001mm < ±0,02mm 35N 5m/sec TABLE II TECHNICAL SPECIFICATIONS OF THE KR3 MANIPULATOR. featuring sampling time T s = 12ms, its endeffector motion can be controlled by applying force or velocity reference signals, defined in the joint space or in the operational space. In the application of interest, we chose the operational space velocity control. Hence, for the sake of simplicity, we modeled the slave dynamics as an integrator with onestep time delay, yielding the transfer function H(z): H(z) = T s z(z 1) In order to measure the forces due to the interaction with the operational environment, the slave endeffector was (1) Hence the network port is passive until E k 0, otherwise the port is generating energy, and the system stability is no more guaranteed. In addition to detecting a violation of passivity condition, the PO is able also to quantify the amount of energy that is being introduced into the system. This information is used to set up a passivity controller α to dissipate such an amount of energy, in order to restore the port passivity. The passivity controller (PC) is defined by the following control equations: F h (n) = { F e (n) 1 α(n) = E PO(n) TF e (n) 2 i f E PO < 0 0 i f E PO 0 V h (n) = V e (n) 1 α(n) F e(n) The teleoperator system with the passivity controller is then represented by the block scheme depicted in Fig. 4. Fig. 4. α. V h V e α F h OMEGA KUKA F e Environment (2) The masterslave teleoperator system with the passivity controller In order to filter out the noise from the velocity signals the discretetime First Order Adaptive Windowing (FOAW) filter

introduced in [10] has been implemented. It originates from common FIR filters but uses adaptive windowing. Hence, it minimizes the velocity error variance while maximizes the accuracy of the estimates, requiring no tradeoff between noise reduction, control delay, estimate accuracy, reliability, computational load, transient preservation, and difficulties with tuning. The time window size is set as the maximum size such that the straight line joining the extreme samples passes through the uncertainty interval of each sample falling inside the window. Hence, as the size n is adapted, the velocity sample ˆV(k) at time instant k is computed as: ˆV(k) = 1 nt c (X(k) X(k n)) (3) where X(k) is the endeffector position at time instant k. The main advantage of this generalpurpose approach consists of its independency from the dynamical models of the master and of the slave devices, which makes it usable with any hardware setup. On the other hand, the main drawback of this technique is that the control effort determined by the PC can lead to actuator saturation. Generally, in order to prevent saturation, the PC signal is upper bounded, but this in turn can reflect in a drop of performance. In fact, in such a case the dissipation of the exceeding energy may require more than one time step, leading to transient vibration effects. A simpler control strategy has been designed for this teleoperation system relying on the assumption that the user s commanded motions during microinvasive neurosurgery interventions will be slow and sharp, thus also the force reflection will be fed back with slow dynamics. Hence, we designed a simple proportionalderivative (PD) controller in order for the slave endeffector to track the master endeffector motion, filtering out all frequency contents exceeding a predefined bandwidth. Hence, the PD transfer function C(z) is defined as: C(z) = k P z 1 T s z k D (4) The block scheme for the teleoperation system can be simply represented as: (PD) control. In this experimental campaign, our design specifications for the PD controller were oriented to filter out all movements exceeding a bandwidth of 2Hz, yielding k P = 3 and k D = 0.35. We remark that this choice was adopted taking into account that this work is addressed to a microinvasive neurosurgery application, hence the accuracy and safety during task completion are privileged in spite of a loss of dynamical performance. In the following, we report the results achieved in three teleoperation tasks: rigid contact, soft contact and needle insertion. For each task, we recorded position, velocity and force of both master and slave endeffectors. Fig. 6. First task: rigid contact with a high stiffness object. In the first task, the contact with a rigid wall was performed, as shown in Fig. 6. The experimental data acquired using the PC control and the PD control are shown in Fig. 7 and Fig. 8 respectively. Omega X h V C(z) r X H(z) e Environment F e Fig. 5. The masterslave teleoperator system with the PD controller. where X h and X e are the master and slave endeffector positions respectively, V r is the velocity reference for the slave and F e is the force measured by the slave sensor. Again, the FOAW filter was adopted in order to filter out the noise from the velocity signals. IV. EXPERIMENTS Several experiments have been carried out to evaluate the performance of the teleoperation system using the passivity control (PC) and the lowpass proportionalderivative Fig. 7. Trajectories and energies for a rigid contact using PC control. The second task consisted in remotely touching the foam rubber dice depicted in Fig. 9, whose stiffness has been estimated about 100 N m. The Fig. 10 and Fig. 11 show the data recorded during the contact, using the PC control and the PD control. Finally, the third task consisted in remotely inserting a syringe needle into an organic material. To this end, the needle was rigidly attached to the slave endeffector, as

Fig. 10. Trajectories and energies for a soft contact using PC control. Fig. 8. Trajectories and energies for a rigid contact using PD control. Fig. 9. Second task: soft contact with a deformable object. Fig. 11. Trajectories and energies for a soft contact using PD control. shown in Fig. 12. We were interested in experiencing the effects of penetration and of viscous dumping due to the perforation of the skin and of the internal pulp. In this experiment, as target object we chose a kiwi. As it was expected, the forces stemming from this type of interaction were almost impossible to be perceived by the user, hence it was required to amplify the measured forces. The Fig. 13 and Fig. 14 show the trajectories recorded during the contact, using the PC control and the PD control, and amplifying the forces with a gain k = 10. The PC was able to restore the system passivity every time it was required during all tasks, thus guaranteeing the stability. Using the PD controller, the system was always stable. In terms of masterslave position tracking, in the rigid contact the PC performance were slightly higher than for the PD, while in the other tasks there are no significant differences. On the other hand, as regards the haptic feedback, the PD was always able to render smooth contact forces, while the PC generally delivered noisy force profiles. This can be ascribed to the PC efforts required to restore the system passivity. Recall that as soon as the passivity observer reveals that the energy is negative, the controller attempts to dissipate such an amount of energy, possibly in a single step. Hence the PC impulsive control efforts can affect the haptic feedback, providing a noisy force profile. Fig. 12. Third task: insertion of a needle into a perforable material. Fig. 13. Trajectories and energies for needle insertion using PC control.

wish to thank also Francesco Chinello for his precious collaboration. Fig. 14. Trajectories and energies for needle insertion using PD control. V. DISCUSSION AND CONCLUSION This paper addresses design issues characterizing a teleoperation control system targeted at driving the insertion of a linearstage rigid endoscope into the brain of the patient for neurosurgery interventions. This activity is part of the project RoboCAST: ROBOt and sensors integration for Computer Assisted Surgery and Therapy. We present preliminary results of our current research, addressed towards evaluating the applicability of a generalpurpose control scheme compared to a specific and taskoriented architecture. The generalpurpose control scheme we chose is the Time Domain Passivity Control. Then, the taskoriented scheme is a proportionalderivative control, based on the assumption that during microsurgery interventions the user s commanded motions and the reflected forces will be characterized by slow dynamics. Hence, the PD was designed in order to filter out all surgeons motions exceeding a predefined bandwidth, thus privileging task accuracy and safety in spite of a loss of dynamical performance. The experimental setup was a masterslave system composed by a Omega Haptic Device (master) and a KUKA KR3 robot (slave). Three tasks were experimented to qualitatively evaluate the system performance: rigid contact with high stiffness objects, soft contact with a deformable object and finally the insertion of a needle into a perforable material. The results stemming from this preliminary study show that even if the taskoriented design provides lower dynamical performance than the generalpurpose one, it revealed to be stable and was able to render smoother forces in any situation, improving the user s kinesthetic perception during the the task remote control. Among the future perspectives in this research, we planned a further development of the taskoriented design, in order to improve dynamical performance and to formalize the stability analysis. REFERENCES [1] P. Hokayem and M. Spong, Bilateral teleoperation: An historical survey, Automatica, vol. 42, no. 12, pp. 2035 2057, 2006. [2] RoboCAST: ROBOt and sensors integration for Computer Assisted Surgery and Therapy Grant FP7ICT2007215190 http://www.robocast.eu/. [3] B. Hannaford, A design framework for teleoperators with kinesthetic feedback, IEEE transactions on Robotics and Automation, vol. 5, no. 4, pp. 426 434, 1989. [4] J. Ryu and D. Kwon, A novel adaptive bilateral control scheme using similar closedloop dynamic characteristics of master/slave manipulators, Journal of Robotic Systems, vol. 18, no. 9, pp. 533 543, 2001. [5] R. Anderson and M. Spong, Asymptotic stability for force reflecting teleoperators with time delay, The International Journal of Robotics Research, vol. 11, no. 2, p. 135, 1992. [6] S. Salcudean, Control for teleoperation and haptic interfaces, Lecture Notes in Control and Information Sciences, pp. 51 66, 1998. [7] R. Adams and B. Hannaford, Stable haptic interaction with virtual environments, IEEE Transactions on robotics and Automation, vol. 15, no. 3, pp. 465 474, 1999. [8] J. Colgate, Robust impedance shaping telemanipulation, IEEE transactions on Robotics and Automation, vol. 9, no. 4, pp. 374 384, 1993. [9] J. Ryu, D. Kwon, and B. Hannaford, Stable teleoperation with timedomain passivity control, IEEE Transactions on robotics and automation, vol. 20, no. 2, pp. 365 373, 2004. [10] F. JanabiSharifi, V. Hayward, and C. Chen, Discretetime adaptive windowing for velocity estimation, Control Systems Technology, IEEE Transactions on, vol. 8, no. 6, pp. 1003 1009, 2000. VI. ACKNOWLEDGMENTS This work has been supported by the European Community under Grant FP7ICT2007215190 RoboCAST. We