Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 000000000
SPECIFICATION MODEL RSP-500-5 RSP-500- RSP-500-5 RSP-500-4 RSP-500-7 RSP-500-48 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER 5V 40A 0 ~ 40A 00W V 5A 0 ~ 5A 500W 5V 00A 0 ~ 00A 500W 4V 63A 0 ~ 63A 5W 7V 56A 0 ~ 56A 5W 48V 3A 0 ~ 3A 536W RIPPLE & NOISE (max.) Note. 50mVp-p 50mVp-p 50mVp-p 50mVp-p 50mVp-p 00mVp-p OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 4.5 ~ 5.5V ±.0% 0 ~ 3.5V 3.5 ~ 6.5V 0 ~ 6.4V 4 ~ 30V 43 ~ 56V LINE REGULATION LOAD REGULATION ±.0% SETUP, RISE TIME HOLD UP TIME (Typ.) 500ms, 00ms at full load 0ms at full load 4ms at full load 6ms at full load VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) 90 ~ 64VAC 47 ~ 63Hz 0.95/30VAC 7 ~ 370VDC 0.98/5VAC at full load INPUT EFFICIENCY (Typ.) 80% 87% 87% 90% 90% 9% AC CURRENT (Typ.) 7A/5VAC 8A/30VAC INRUSH CURRENT (Typ.) LEAKAGE CURRENT 30A/5VAC <.0mA / 40VAC 60A/30VAC 05 ~35% rated output power OVERLOAD Note.4 Protection type : Constant current limiting unit will shut down o/p voltage after 5sec. Re-power on to recover PROTECTION 5.75 ~ 6.75V 3.8 ~ 6.8V 7 ~ 0.5V 7.6 ~ 3.4V 3 ~ 36.5V 57.6 ~ 67.V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down OUTPUT VOLTAGE PROGRAMMABLE(PV) Adjustment of output voltage is allowable to 70 ~ 00% of nominal output voltage. Please refer to the Function Manual. CURRENT SHARING Up to 6000W or (3+) units. Please refer to the Function Manual. FUNCTION ILIARY POWER V@0.A(Only for Remote ON-OFF control) REMOTE ON-OFF CONTROL Please see the Function Manual. REMOTE SENSE Compensate voltage drop on the load wiring up to 0.3V. Please refer to the Function Manual. ALARM SIGNAL OUTPUT Power OK signal. Please see the Function Manual. WORKING TEMP. -0 ~ +70 (Refer to "Derating Curve") WORKING HUMIDITY 0 ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 0 ~ 95% RH non-condensing TEMP. COEFFICIENT ± 0.05%/ (0 ~ 50 ) VIBRATION 0 ~ 500Hz, G 0min./cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-, TUV EN60950-, EAC TP TC 004, BSMI CNS4336- approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:00M Ohms / 500VDC / 5 / 70% RH Parameter Standard Test Level / Note SAFETY & EMC (Note 5) OTHERS NOTE EMC EMISSION EMC IMMUNITY MTBF DIMENSION Conducted Radiated Harmonic Current Voltage Flicker EN5503 (CISPR3) / EN550 (CISPR) EN5503 (CISPR3) / EN550 (CISPR) EN6000-3- EN6000-3-3 Class B Class A ----- ----- EN5504, EN604-3, EN6000-6-, BSMI CNS3438 Parameter ESD Radiated EFT / Burst Surge Conducted Magnetic Field Voltage Dips and Interruptions Standard EN6000-4- EN6000-4-3 EN6000-4-4 EN6000-4-5 EN6000-4-6 EN6000-4-8 EN6000-4- 65.3K hrs min. Telcordia SR-33 (Bellcore) ; 90.3K hrs min. MIL-HDBK-7F (5 ) 78*7*83.5mm (L*W*H) PACKING 3.0Kg; 4pcs/3Kg/.9CUFT Test Level / Note Level 3, 8KV air ; Level, 4KV contact Level 3 Level 3 Level 3, KV/Line-Earth ; Level, KV/Line-Line Level 3 Level 4 >95% dip 0.5 periods, 30% dip 5 periods, >95% interruptions 50 periods
Block Diagram PFC fosc : 70KHz PWM fosc : 00KHz I/P EMI FILTER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC PFC CONTROL POWER SWITCHING O.L.P. RECTIFIERS & FILTER O.V.P. +S -S O.T.P. POWER PWM CONTROL LOAD SHARING FAN DETECTION CIRCUIT REMOTE CONTROL RECTIFIERS & FILTER PV POK RC LS POWER (V/0.A) Static Characteristics INPUT MODEL 5V V 5V 00 90 80 00~64VAC 90VAC 00W 40A 960W 9A 500W 5A 00W 00A 500W 00A 00W 80A LOAD (%) 70 60 50 MODEL INPUT 00~64VAC 4V 5W 63A 7V 5W 56A 48V 536W 3A 90 00 0 40 50 60 80 00 0 40 64 INPUT VOLTAGE (V) 60Hz 90VAC 09.6W 50.4A 09.6W 44.8A 8.8W 5.6A Derating Curve Efficiency vs Load (48V Model) LOAD (%) 00 80 60 50 40 0 +V,+5V -0 0 0 0 30 40 45 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE ( ) +5V Others EFFICIENCY (%) 9 90 88 86 84 8 80 78 76 0% 0% 30% 40% 50% 60% 70% 80% 90% 00% LOAD The curve above is measured at 30VAC.
Function Manual. Remote Sense The Remote Sense compensates voltage drop on the load wiring up to 0.3V CN PIN7 -S PIN8 +S LOAD Sense lines should be twisted in pairs to minimize noise pick-up.. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim) In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 70~00%(Typ.) of the nominal voltage by applying EXTERNAL RESISTANCE CN PIN7 -S PIN8 +S Connect an external resistor between TRIM(pin4) & -S(pin3 or pin4 or pin5) on CN or CN, and +S &, -S & also need to be connected. Vout 00% 90% 80% 70% 0Ω 470Ω.8KΩ OPEN Fig.. External Resistance (Typical) R
3.Remote ON-OFF Remote ON-OFF is activated by the configuration with respect to CN,CN and CN3 as shown in the following diagram. CN PIN PIN RC PIN5 RC CN3 PIN6 PIN4 G Example 3.(A): Using external voltage source V typ..kω 50Ω RC RC 60Ω 5V SW G Example 3.(B): Using internal V auxiliary output V typ..kω 50Ω RC RC SW G Example 3.(C): Using internal V auxiliary output V typ..kω 50Ω RC RC SW G Connection Method SW Logic Fig. 3.(A) Fig. 3.(B) Fig. 3.(C) Output on SW Open SW Open SW Close Output off SW Close SW Close SW Open
4.Alarm Signal Output Alarm signal is sent out through " POK" & " POK GND" and pins on CN3. Please acknowledge an external voltage source is required for this function. CN3 PIN P OK GND PIN P OK Function POK Description The signal is "Low" when the power supply is above 65% of the rated output voltage, or say, Power OK The signal turns to be "High" when the power supply is under 65% of the rated output voltage, or say, Power Fail Table 4. Explanation of alarm Output of alarm(p OK) Low (0.5V max at 0mA) High or open (External applied voltage 0mA max.) POK 0.uF 00KΩ R V P OK GND External voltage and R (The max. Sink is 0mA and 50V) Fig. 4. Internal circuit of P OK (Open collector method)
5.Current Sharing with Remote Sense RSP-500 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below : The power supplies should be paralleled using short and large diameter wiring and then connected to the load. Difference of output voltages among parallel units should be less than 0.V. The total output current must not exceed the value determined by the following equation: Maximum output current at parallel operation=(rated current per unit) (Number of unit) 0.9 No.(Master) When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit Sense lines should be twisted in pairs to minimize noise pick-up. No.(Slave) No.3(Slave) +S -S Load No.4(Slave) +S,-S and CS are connected mutually in paralle.
Mechanical Specification Case No.943A Unit:mm 40. 6 max. 83.5 38..7 38 8-M4 L=5(Both Sides) 6 ψ8.5 78 40. -M4 OUTPUT Air flow direction 7 4-M4 L=5 7.5 93 I/P 0 CN CN CN3 864 64 864 3 3 7 7 5 5 5 3 LED SVR 3 4 3 Mounting Instruction Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque M4 5mm 7~0Kgf-cm Mounting Surface Chassis of RSP-500 Control Pin No. Assignment (CN,CN) : HRS DF-8DP-DS or equivalent 8 7 Mating Housing Terminal HRS DF-8DS or equivalent HRS DF-**SC or equivalent Mounting Screw L CN and CN are connected internally. Pin No. 3,5,7 4 6 8 Function RC -S TRIM LS(Current Share) +S Description Remote ON-OFF Ground Remote ON-OFF Negative sensing for remote sense Connection for output voltage programming Current Share Postive sensing for remote sense
Control Pin No. Assignment (CN3) : HRS DF-6DP-DS or equivalent 6 Mating Housing HRS DF-6DS or equivalent 5 Terminal HRS DF-**SC or equivalent Pin No. 3 4 5 6 Function P OK GND POK G RC Description Power OK Ground Power OK Signal Remote ON-OFF Ground Auxiliary Ground Remote ON-OFF Auxiliary Output AC Input Terminal Pin No. Assignment Pin No. 3 Assignment FG Diagram Mx a imum mounting torque 8Kgf-cm Installation Manual Please refer to : http://www.meanwell.com/manual.html