DC 4Q POWER AMPLIFIER 200kW 2 RANGES HIGH POWER RS232

Similar documents
22 kw 4Q POWER AMPLIFIER RS232

200 kw 4Q POWER AMPLIFIER RS232

RS232. DC POWER SUPPLY 20kW 3 RANGES

3 x 30 kva AC POWER SOURCE PCU-3x30000-AC/DC-300V-100A-2G-HP RS232

RS232 AC-DC VOLTAGE POWER AMPLIFIERS PCU-10K / 15K / 20K / 24K-AB/4G/HP PERFORMANCES APPLICATIONS DESCRIPTION COMMERCIAL REFERENCES

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

PA-AB 4Q POWER AMPLIFIER VA Page 1/5

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

PA-AB 4Q POWER AMPLIFIER

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

MULTICHANNEL ACQUISITION SYSTEM

LVA 4-Quadrant Amplifier 1000

DCPS Programmable DC Power Supply

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

S11 Adjustable Speed Drive Engineering Specification

Multimeter 500CVD21 RTU500 series

EL-AC Electronic Load

LVA 4-Quadrant Amplifier 5000

Gutor PxW AC UPS Designed for North American Market

APS series of 4-quadrant amplifiers

VF-nC1 Adjustable Speed Drive Engineering Specification

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

High Stability Voltage Source

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

California Instruments BPS Series kva V A / Phase. Overview. High Power AC Source. Expandable Power Levels.

E3 Adjustable Speed Drive Engineering Specification

DOBLE F6150e TECHNICAL SPECIFICATIONS

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DOBLE F6150SV TECHNICAL SPECIFICATIONS

3196 POWER QUALITY ANALYZER. Solve All Your Power Quality Problems ISO14001 JQA-E Power Measuring Instruments

Q.raxx A slimline RS / EC Universal Measurement System

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

Parallel AMX AC Power Systems

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Vibration Transducer Calibration System

Dale Power Solutions Ltd

LED Driver Compact dimming

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

THREE PHASES CONVERTER DC-3xAC. The converter ref. M03740 creates, from a DC power voltage and an auxiliary power supply, a three-phase AC network.

9063-RC Data Acquisition and Control Interface

Q.raxx A slimline RS / EC

Amplifier HF MHz

GE-AC&DC AC&DC Voltage Source

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Energy Management Three-phase energy meter with output modules Type EM4-DIN

PFXLM4B01 D * * (1) (2) (3) (4)

Because you can t afford downtime

LED Driver Compact dimming

GPRS Inclinometer. Zigbee. CDMA Vibration-wire. SSI PWM Switch Analog. Features. Descriptions

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

GE+ Grid Emulator. Key features. Highlights. High-Resolution and Dynamics. Efficiency and Flexibility. Smooth Integration. Harmonics Generation

GE+ Grid Emulator Plus

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description

Issue 03/2013. The Electronic Load

LED Driver Compact fixed output

Q.raxx A101-8 slimline RS / EC

Data Sheet. RISH Master Record %THD

DM-III Multitest & DM-III Multitest F Power Quality Recorders

DCR DC Output Module

OUTPUT CHARACTERISTICS

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series

PHASED OUT. LED Driver Compact dimming. Driver LCAI 20W 350mA 900mA ECO SR ECO series

SYSTEM 8800 Model 883 Power Converter

T 1000 PLUS Secondary Injection Relay Test Set

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

Arbitrary/Function Waveform Generators 4075B Series

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments

AXYS IndustryAmp PB-800

LED Driver Linear / area dimming

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 350mA 900mA TOP C TOP series

PLC-K506 Series FEATURES DESCRIPTION FEATURES

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

Model 310H Fast 800V Pulse Generator

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 350mA 550mA ECO lp ECO series

Power Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers

LED Driver Linear / area dimming. Udriver LCAI 20W 350mA 550mA ECO lp ECO series

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 100W 350mA 900mA ECO INDUSTRY sl ECO series

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

2520 Pulsed Laser Diode Test System

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series

Stabilized Differential Relay SPAD 346. Product Guide

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

Model 865 RF / Ultra Low Noise Microwave Signal Generator

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Transcription:

PERFORMANCES High accuracy High stability Fast transients High inrush current facilities Very low noise Very low output impedance Quadrant change without transition Power analyzer included Reverse polarity included RS232 APPLICATIONS Aircraft networks LVDC HVDC Tests in accordance with standards DO160G, ABD100.1.8, MIL-STD-704, ISO1540-2006 DESCRIPTION PCU-200K-DC is a voltage power amplifier 2 quadrants DC. Its high electrical performances allow to test or simulate all kinds of generators or loads with high dynamics, very low noise over a wide voltage range. Linear technology allows a quick and easy integration for "Real time" or "Hardware In the Loop" applications in combination with simulators such as Opal-RT, dspace or National Instruments. Remote control using TCP/IP protocol on an Ethernet link or SCPI protocol on a RS232 serial link allows easy integration into an automatic test system. * HIGH POWER (HP): new generation amplifier including last transistors design for 30% power increase COMMERCIAL REFERENCES PCU-200K-DC-4Q-360V-310A-2G-HP Option PCU-200K-SR customized voltage ranges Option PCU-200K-ISO OUTPUT voltage and current read-backs Option PCU-200K-MAINS specific mains power supply Document ref. DC 4Q amplifier 200kW 2 ranges HP V4 - Page 1 / 10

DESCRIPTION CABINET Nb10 SOURCE SINK K100 R K101 10p 10n a b DC SWITCH UNIT K301 + Channel 3 +VDC Readback I+ Readback U+ CABINET Nb11 SOURCE SINK K110 R K111 11p 11n c d ISOLATED MEASURES CABINET Nb12 SOURCE SINK K120 R K121 12p 12n e f K302 ISOLATED MEASURES 0 Channel 3 0V Readback I- Readback U- CABINET Nb13 SOURCE SINK K130 R K131 13p 13n g h K303 - Channel 3 -VDC HIL SYSTEM (RT LAB) Each amplifier is made of: Four power amplifiers 50kW o Connected in series o Two ranges : 150V-310A and 180V-260A each o Equipped with 80% Sink module. One switch unit: o A set of relays activated to connect amplifiers output, o Options ISO OUTPUT & POWER ANALYZER to generate voltage and current readbacks and do measurements on outputs. The POWER ANALYZER is described on page 6 of this document. HIL system send pilot signal to amplifiers and receives read-backs from output voltage and current. Power amplifiers and DC switch unit are equipped with emergency button. One action on an emergency button switches off all power amplifiers of the system. Document ref. DC 4Q amplifier 200kW 2 ranges HP V4 - Page 2 / 10

OUTPUTS FEATURES Power Rated power 50 000 W Output DC Ranges 150 VDC 180 VDC Voltage and current SOURCE Range 150 VDC Range 180 VDC Voltage 0-150 VDC 0-180 VDC Permanent current (In) 0-310 ADC 0-260 ADC Maximum current (1,5 x In 5 mn) 460 ADC for a voltage 390 ADC for a voltage between 125 and 150VDC between 150 and 180VDC Maximum peak current (1 s) 900 A peak 780 A peak Current SINK Range 150 VDC Range 180 VDC Permanent current 0-250 ADC 0-210 ADC Voltage accuracy Typical 0,1% of range + 0,1% of programmed value Resolution 12 bits Current accuracy Typical 0,1% of range + 0,1% of programmed value Resolution 12 bits Voltage regulation for a mains variation of +6% / -10% Max < 0,1% of rated voltage Voltage regulation for a current variation from 0 to 100% Max < 0,1% of rated voltage Noise Max RMS 0,02% of rated voltage Max peak to peak 0,3% of rated voltage Variation with a square signal pilot Rise time 10% / 90% < 20 µs Fall time 10% / 90% < 20 µs Transfer time < 20 µs Transition from Q1 to Q4 < 20µs Variation according temperature Typical 50 ppm/ C Max 100 ppm/ C Stability after 15 minutes of operation Max < 0,05% of rated voltage Insulation of the outputs versus case ground Measurement at 500 VDC > 100 MΩ Accuracy of the measurements displayed on the touch screen Voltage measurement 0,1% of range + 0,1% of measure Current measurement 0,1% of range + 0,1% of measure Document ref. DC 4Q amplifier 200kW 2 ranges HP V4 - Page 3 / 10

MECHANICAL AND ENVIRONMENTAL INPUT MAINS FEATURES Mains network Number of phases 3 Phases + Earth without Neutral Voltage 400 VRMS -10% +6% Frequency 47-63 Hz Input current for full output power (1,5 x In) Max 140 ARMS per phase Protection Magnetic and thermal breaker Inrush current Limited at 2 times max current Dielectric strength between mains input and output connected to case ground Measured at 1500 VRMS / 50Hz Current < 10 ma Input signal amplitude Insulation > 10 MΩ (1) Voltage for full output scale + 10V peak Max. voltage + 15 V peak Input impedance 10 kω Input signal frequency Fundamental DC Ripple (small signals) Max 50 khz Paints Frame Aluminum painted RAL7021 Panels Aluminum painted RAL7035 Dimensions and weight of each bench Width 800 mm Height 2230 mm (43U) Depth 800 mm Weight 600 kg Temperature and humidity Storage temperature -10 C à +85 C Operating temperature +0 C à +50 C Humidity 10% - 90% non-condensing Noise (fans working at full speed) Measured at 1 m < 70 dba Marking Marking CE Protection level IP20 Protections Against overload Voltage limitation (1) Against short circuit on output Automatic output switch off (2) Against overheat Automatic output switch off (3) 1) In case of temporary overload the voltage decreases to limit the current. 2) The output is switched off and will have to be reactivated by the touch screen or an external command. 3) A temperature sensor is installed on each power element. It switches off the load in case of overheat. The load must be re-activated by a local control or an external control. Document ref. DC 4Q amplifier 200kW 2 ranges HP V4 - Page 4 / 10

MECHANICAL AND ENVIRONMENTAL INPUT OUTPUTS DC SWITCH UNIT FEATURES Power Number of outputs one Connections + 0 and - Dielectric strength between mains input and output connected to case ground Measured at 1500 VRMS / 50Hz Current < 10 ma Read-backs accuracy (option PCU-100k-ISO OUTPUT included) Voltage read-back 1 VDC for 40 VDC Current read-back 1 VDC for 120 ADC Power Number of inputs four Number of ranges one Dielectric strength between mains input and output connected to case ground Measured at 1500 VRMS / 50Hz Current < 10 ma Paints Frame Panels Dimensions and weight of each bench Width Height Depth Weight Temperature and humidity Storage temperature Operating temperature Humidity Marking Marking Protection level Protections Relays management Aluminum painted RAL7035 Aluminum painted RAL7035 750 mm 650 mm 400 mm 80 kg -10 C à +85 C +0 C à +50 C 10% - 90% non-condensing CE IP20 Close and control Document ref. DC 4Q amplifier 200kW 2 ranges HP V4 - Page 5 / 10

ANALOG INPUTS POWER ANALYZER FACILITES The POWER ANALYZER included allows acquiring voltage and current signals simultaneously at a maximum sampling rate of 100 kech/s, performing calculations and returning the results of the calculations or samples to a host system. Each channel has its own memory and its own 16-bit converter, allowing sampling on both channels simultaneously. It offers synchronous analytics with the process and enables a significant reduction in the cycle time while improving the accuracy of the measurements. Three modes of acquisition are available : Permanent mode, Synchronous mode, Acquisition-compression mode. Analog inputs Number of channels 2 Input type Direct Acquisitions Input voltage ±10,0 V peak Common mode max. voltage 15 V Resolution 16 bits Accuracy 0,05% of range + 0,05% of measurement Sampling Frequency from 20 Ech/s to 100 kech/s per channel Memory per channel 256 kwords of 16 bits (512 kbyte) Analysis Wattmeter See note (1) Chronometer Resolution 10 or 100 µs Accuracy 10 or 100 µs + 0.01% (1) Each channel can be attached to an electrical signal, currently voltage and current. All of the following operations can be performed on each channel: Mean value RMS value during a time of 5 ms to 2 s Variable frequency filter Minimum / maximum Maximum RMS value Measurement time: time during which the signal is greater (in absolute value) to a specified value More details are described in technical sheet FT-Carte ACQ-EN-V1. Document ref. DC 4Q amplifier 200kW 2 ranges HP V4 - Page 6 / 10

3 ACQUISITION MODES Permanent mode: signals are continuously analyzed and measurement records are updated periodically. They are accessible by the host system and provide information on the current value of the channel. The time base for the calculation (FFT) is fixed or issued out of the analyzed signal. In the latter case, a high-speed PLL (over one period) calculates the sampling frequency to acquire 1024 points per period. After acquisition, the board makes a FFT without windowing (or rectangular) guaranteeing a high accuracy of measurement with only one period. Synchronous mode: measurements are engaged / disengaged on order of the host system with an accuracy of 100 µs. Records are updated only during this time period, so that the measured parameters are correlated with stimulus driven also by the host system. As for the previous mode, the time base is fixed or dynamic. Acquisition-compression mode: this mode is possible only on the 2-way cards. Sampling is at the maximum frequency, but only the points that differ more from x % (x being programmable) of the previous point are preserved and dated. It is thus possible to have a maximum of details during a sudden change and a minimum of memory used if the signal is "flat". This mode is particularly suitable for the measurement on a DC bus (batteries for example). CONTROL SOFTWARE Puissance+ OPS3 software allows configuring for each card measurements to be carried out (for example card installed in an AC load system). By activating the continuous repatriation of measurements, this "Power meter" screen is refreshed periodically. It displays the instantaneous values of measures. The rank of the harmonic can be also selected. This Acquisition screen configures the duration of a sample and the duration of the acquisition. It allows also saving the acquisition and launching software visualization OPS1. Document ref. DC 4Q amplifier 200kW 2 ranges HP V4 - Page 7 / 10

OPTIONS Option PCU-200k-SR : customized output ranges Output voltage value can be customized - Please consult us. Option PCU-200k-ISO OUTPUT : add read-backs of voltage and current Read-backs of voltage and current are isolated from output. With an amplitude ± 10 V peak, they are real time images of voltage and current on the output of the source. This option is included in the transformer and switch unit. AC SOURCE OUTPUT ISO OUTPUT HIGH LOW Voltage Image Current Image Option PCU-200k-MAINS : customized mains input Mains input power can be adapted to your network - Please consult us. AC OUTPUT ON CHANNELS 1 AND 2 This configuration is described on datasheet FT-PCU-100k-AC-EN. DC OUTPUT ON CHANNEL 4 This configuration is described on datasheet FT-PCU-22k-DC-EN. Document ref. DC 4Q amplifier 200kW 2 ranges HP V4 - Page 8 / 10

POWER DIAGRAM This diagram expresses the relationship between the current and the voltage in absorption or in generation. X-coordinates express the voltage. Y-coordinates express the current. Continuous operation is allowed inside diagrams. In generation or absorption limitations are due to the heating of the power transistors. Operation 'on the outside' diagrams will result in: an immediate switch-off by over-current protection if current is above the max peak current of the range, a break after a delay by thermal protection in case of overheating of the power parts. Range 300V / 310A (positive output on channel 3) Quadrant Q1: source mode Permanent current is 310 A between 240 and 300 VDC Quadrant Q4: sink mode Permanent current is -250 A between 240 and 290 VDC (80% of source current) In sink mode, limitation is made by resistor in series with power transistors Range 360V / 260A (positive output on channel 3) Quadrant Q1: source mode Permanent current is 260 A between 270 and 360 VDC Quadrant Q4: sink mode Permanent current is -200 A between 290 and 355 VDC (80% of source current) In sink mode, limitation is made by resistor in series with power transistors Document ref. DC 4Q amplifier 200kW 2 ranges HP V4 - Page 9 / 10

SOFTWARE Puissance + software suite OPS is specially built for an easy control of source. The OPS3 software communicates with the source using an Ethernet or serial link. Example of screen on a similar system The OPS3 software allows sending simple commands (ON / OFF, voltage range, maximum current) and to read and view simple information (status, voltage, current). The OPS3 software is also used to send waveforms to the source. Specification subject to change without notice. Document ref. DC 4Q amplifier 200kW 2 ranges HP V4 - Page 10 / 10