UNISONIC TECHNOLOGIES CO., LTD S LOGIC LEVEL DESCRIPTION Passivated, sensitive gate triaces in a plastic envelope, intended for use in general purpose bidirectional switching and phase control applications. These devices are intended to be interfaced directly to microcontrollers. Logic integrated circuits and other low power gate trigger circuits. SYMBOL MT SOT-3 TO-9 G MT ORDERING INFORMATION Ordering Number Pin Assignment Package Lead Free Halogen Free 3 Packing L-x-T9-B G -x-t9-b TO-9 MT GATE MT Tape Box L-x-T9-K G -x-t9-k TO-9 MT GATE MT Bulk L-x-T9-R G-x-T9-R TO-9 MT GATE MT Tape Reel L-x-AA3-R G-x-AA3-R SOT-3 MT MT GATE Tape Reel of 5 Copyright Unisonic Technologies Co., Ltd QW-R4-6.G
ABSOLUTE MAXIMUM RATINGS PARAMETER SYMBOL RATINGS UNIT -5 5 V Repetitive Peak Off-State Voltage (Note ) -6 V DRM 6 V -8 8 V RMS On-State Current, Full Sine Wave; Tlead 5 I T(RMS) A Non-Repetitive Peak On-State Current t=ms 6 A I (Full Sine Wave; T J =5 Prior to Surge) TSM t=6.7ms 7.6 A Circuit Fusing t=ms I t.8 A s Repetitive Rate of Rise of On-State Current after Triggering I TM =.5A, I G =.A, di G /dt=.a/μs T + G + 5 A/μs T + G - 5 A/μs di T /dt T - G - 5 A/μs T - G + A/μs Peak Gate Voltage V GM 5 V Peak Gate Current I GM A Peak Gate Power P GM 5 W Average Gate Power (over any ms period) P G(AV).5 W Junction Temperature T J +5 Storage Temperature T STG -4 ~ +5 Note:. Absolute maximum ratings are those values beyond which the device could be permanently damaged. Absolute maximum ratings are stress ratings only and functional device operation is not implied.. Although not recommended, off-state voltages up to 8V may be applied without damage, but the triac may switch to the on-state. The rate of rise of current should not exceed 3 A/μs. THERMAL DATA PARAMETER SYMBOL RATINGS UNIT Junction to Lead Full Cycle 6 K/W θ JLEAD Half Cycle 8 K/W Junction to Ambient (Note) θ JA 5 K/W Note: PCB mounted; lead length=4mm ELECTRICAL CHARACTERISTICS (T J =5, unless otherwise specified) PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNIT T + G +.4 3 ma Gate Trigger Current I GT V D =V, I T =.A T + G -.3 3 ma T G -.4 5 ma T G + 3.8 7 ma T + G +. 5 ma Latching Current I L V D =V, I GT =.A T + G - 4. 8 ma T G -. 5 ma T G +.5 8 ma Holding Current I H V D =V, I GT =.A.3 5 ma On -State Voltage V T I T =.A..5 V Gate Trigger Voltage V GT V D =V, I T =.A.7.5 V V D =4V, I T =.A, T J =5..3 V Off-State Leakage Current I D V D =V DRM(MAX), T J =5..5 ma DYNAMIC CHARACTERISTICS (T J =5, unless otherwise specified) PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNIT Critical Rate of Rise of off-state Voltage dv D /dt V DM =67% V DRM(MAX), T J =5 Exponential waveform, R GK =kω 5 5 V/μs Gate Controlled Turn-on Time t GT I TM =.5A, V D =V DRM(MAX), I G =.A di G /dt=5a/μs μs UNISONIC TECHNOLOGIES CO., LTD of 5 QW-R4-6.G
TYPICAL CHARACTERISTICS Maximum on-state Dissipation, PD/W Maximum Permissible Non-Repetitive Peak On-State Current, ITSM/A Maximum Permissible Non-Repetitive Peak On-State Current vs. Number of Cycles, for Sinusoidal Currents Maximum Permissible RMS Current I T(RMS) vs. Lead Temperature Maximum Permissible Non- Repetitive Peak On-State Current, ITSM/A 8 6 4 Number of Cycles at 5Hz I T I TSM time T J initial=5 max Maximum Permissible RMS Current, IT(RMS)/A..8.6.4. 8-5 5 5 Lead Temperature, Tsp/ Maximum Permissible Repetitive RMS on-state Current, IT(RMS)/A Normalised Gate Trigger Voltage, VGT(TJ)/VGT(5 ) UNISONIC TECHNOLOGIES CO., LTD 3 of 5 QW-R4-6.G
TYPICAL CHARACTERISTICS(Cont.) Normalised Gate Trigger Current, IGT(TJ)/IGT(5 ) 3.5.5.5 Normalised Gate Trigger Current vs. Junction Temperature T+G+ T+G- T-G- T-G+ -5 5 5 Normalised Latching Current, IL(TJ)/IL(5 ) 3.5.5.5 Normalised Latching Current vs. Junction Temperature -5 5 5 Transient Thermal Impedance vs. Pulse Width Typical Critical Rate of Rise of off-state Voltage vs. Junction Temperature unidirectional bidirectional. P D t p. us.ms ms t ms.s s s 5 5 Pulse Width, t p /s UNISONIC TECHNOLOGIES CO., LTD 4 of 5 QW-R4-6.G
UTC assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein. UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. UNISONIC TECHNOLOGIES CO., LTD 5 of 5 QW-R4-6.G