Automated Perimeter PTS 1000

Similar documents
OCULUS Twinfield 2. Perimeter. We focus on progress

Frey AP-300 Humphrey Zeiss HFA II 740 perimeters

PERIMETRY A STANDARD TEST IN OPHTHALMOLOGY

We focus on progress OCULUS CENTERFIELD 2

OCULUS Easyfield. Perimeter. We focus on progress

The First True-Color Wide-Field Confocal Scanner

Developments of a peripheral vision system using immersive virtual environment

EXAMINATION OF THE CENTRAL VISUAL FIELD AT

Goldmann vs. Humphrey

Novel 3D Computerized Threshold Amsler Grid Test CA, USA

Examination of the ten degrees of visual field surrounding fixation

The First True Color Confocal Scanner on the Market

Introduction. scotoma. Effects of preferred retinal locus placement on text navigation and development of adventageous trained retinal locus

Instruments Commonly Used For Examination of the Eye

Visual Perception. human perception display devices. CS Visual Perception

THRESHOLD AMSLER GRID TESTING AND RESERVING POWER OF THE POTIC NERVE by MOUSTAFA KAMAL NASSAR. M.D. MENOFIA UNIVERSITY.

Balancing accuracy......and great efficacy

Impressive Wide Field Image Quality with Small Pupil Size

A reduction of visual fields during changes in the background image such as while driving a car and looking in the rearview mirror

The TRC-NW8F Plus: As a multi-function retinal camera, the TRC- NW8F Plus captures color, red free, fluorescein

Suppression in strabismus

PERIPHERAL VISON PATTERN DETECTION DYNAMIC TEST

The First True Color Confocal Scanner

Visual acuity finally a complete platform

Peripheral Prism Glasses for Hemianopia Giorgi et al. APPENDIX 1

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

NANOS Patient Brochure

Fast and accurate vestibular testing

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Slide 4 Now we have the same components that we find in our eye. The analogy is made clear in this slide. Slide 5 Important structures in the eye

Kowa nonmyd WX 3D. 2D/3D non-mydriatic retinal camera. Now approved by the NDESP.

Optical Coherence Tomography Retina Scan Duo

VNG Balance Testing. VN415 / VO425 - Complete solutions for balance testing

Straightforward Vestibular testing

Psych 333, Winter 2008, Instructor Boynton, Exam 1

OCULUS Keratograph 4. Topographer. We focus on progress

STUDY OF ADULT STRABISMUS TESTING PROCEDURES MANUAL

Physiology of Vision The Eye as a Sense Organ. Rodolfo T. Rafael,M.D. Topics

Visual Perception of Images

Methods. 5.1 Eye movement recording techniques in general

TTR2796. Fully Automated Three Phase 250V Transformer Turns Ratio Meter FEATURES AND BENEFITS APPLICATIONS

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

QUANTITATIVE STUDY OF VISUAL AFTER-IMAGES*

Vision. The eye. Image formation. Eye defects & corrective lenses. Visual acuity. Colour vision. Lecture 3.5

ABSTRACT. Keywords: Glaucoma, videopupillography, intraocular pressure, pupil, pupil size, pupillometer 1. INTRODUCTION

Information Guide. Synoptophore (Major Amblyoscope) Heading. Body copy. Body copy bold

Lecture 8. Human Information Processing (1) CENG 412-Human Factors in Engineering May

Vision Monitor. Visual electrophysiology systems. Electroretinography (ERG) Visual evoked potentials (VEP) Electro oculography (EOG)

Three-dimensional computer-automated threshold Amsler grid test

CARAT 930/950. Hardness Testing & Analysis CARAT 930 / 950

VNG/ENG. To Preserve and Improve Balance VISUALEYES BINOCULAR GOGGLES

Rotational Vestibular Chair

Micromedical VisualEyes 515/525 VisualEyes 515/525

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Micromedical VisualEyes 515/525 VisualEyes 515/525

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

you can We have an eye for detail. CF-1 HIGH RESOLUTION DIGITAL RETINAL CAMERA Camera Canon EOS 1Ds Mark III f7.1 1/800 ISO 320

We have already discussed retinal structure and organization, as well as the photochemical and electrophysiological basis for vision.

Low Vision Assessment Components Job Aid 1

Neural Function Measuring System MEE-1000A 16/32 ch. Intraoperative Monitoring System

Refractive Power / Corneal Analyzer. OPD-Scan III

A New Method for Estimating Effects of Visual Field Loss in a Panoramic Driving Environment

Non-Mydriatic Auto Fundus Camera AFC-330

Fully automated three phase 250V Transformer Turns Ratio Meter

Auto Ref / Kerato / Tono / Pachymeter TONOREFTM III

3-D Computer-Automated Threshold Amsler Grid Test

Micromedical VisualEyes 515/525

REAL TIME PATTERN RECOGNITION AND FEATURE ANALYSIS FROM VIDEO SIGNALS APPLIED TO EYE MOVEMENT AND PUPILLARY REFLEX MONITORING

Visual Effects of Light. Prof. Grega Bizjak, PhD Laboratory of Lighting and Photometry Faculty of Electrical Engineering University of Ljubljana

Objectives. 3. Visual acuity. Layers of the. eye ball. 1. Conjunctiva : is. three quarters. posteriorly and

ensory System III Eye Reflexes

The human electroretinogram and occipital potential in response to focal illumination of the retina

SOCRATES. Auditory Evoked Potentials

Van Orden Stars & Cheiroscopic Tracing

Visual Effects of. Light. Warmth. Light is life. Sun as a deity (god) If sun would turn off the life on earth would extinct

CONTACT LENSES Discover a different world

Human Senses : Vision week 11 Dr. Belal Gharaibeh

Yokohama City University lecture INTRODUCTION TO HUMAN VISION Presentation notes 7/10/14

Macula centred, giving coverage of the temporal retinal. Disc centred. Giving coverage of the nasal retina.

RESEARCH AND DEVELOPMENT OF DSP-BASED FACE RECOGNITION SYSTEM FOR ROBOTIC REHABILITATION NURSING BEDS

Vision Basics Measured in:

Exercise questions for Machine vision

The eye* The eye is a slightly asymmetrical globe, about an inch in diameter. The front part of the eye (the part you see in the mirror) includes:

B.A. II Psychology Paper A MOVEMENT PERCEPTION. Dr. Neelam Rathee Department of Psychology G.C.G.-11, Chandigarh

binocular projection by electrophysiological methods. An account of some METHODS

UNITY VIA PROGRESSIVE LENSES TECHNICAL WHITE PAPER

Non-Mydriatic Auto Fundus Camera AFC-330

Holy Cross High School. Medical Physics Homework

CGT 511 Perception. Facts. Facts. Facts. When perceiving visual information

Optical Coherence Tomography. RS-3000 Advance / Lite

Fourier Domain (Spectral) OCT OCT: HISTORY. Could OCT be a Game Maker OCT in Optometric Practice: A THE TECHNOLOGY BEHIND OCT

2Win Binocular Mobile Refractometer and Vision Analyzer

Inquiry Unit for CT State Science Standard 5.2

2 The First Steps in Vision

Retina 400 THE SIMPLE AND FLEXIBLE SOLUTION FOR HIGH DEFINITION RETINAL IMAGERY NON-MYDRIATIC RETINAL CAMERA C/D AUTO 60 H X 45 V LED. 2,2 mm.

Outline 2/21/2013. The Retina

Scanning Eye Movements in Homonymous Hemianopia Documented by Scanning Laser

CHAPTER 4 LOCATING THE CENTER OF THE OPTIC DISC AND MACULA

SPIRE MATHS Stimulating, Practical, Interesting, Relevant, Enjoyable Maths For All

Transcription:

PTS 1000

Automated Perimeter PTS 1000 is a modern diagnostic instrument for precise and fast testing of field of vision. It offers static and kinetic stimuli with all Goldmann stimuli sizes and all stimuli colors used in perimetry. Wide range of strategies and analysis tools combined with intuitive inter face give you powerful diagnostic tool whose handling you will enjoy. Built-in maps and possibility of creating own ones give a chance to examine only these areas, which are necessary. With PTS1000 examination doesn't have to be tiring anymore. STANDARD VISION TESTS Depending on chosen test strategy, it enables defining the sensitivity threshold of retina in a given area, as well as making a fast screening test. Accurate threshold, Intelligent advanced threshold, Screening and quick 3- zone can be selected according to needs and patient's condition. TIME SAVING Advanced strategy which utilizes special algorithm allows quicker examination without loss in result resolution. 30-2 field can be tested in less than 3 minutes. Additionally 3 accuracy levels can be selected. Reduced Field and Neurological Field Reduction options help reduce examination time for other strategies. RELIABILITY PTS1000 is all you need for modern perimetry: Goldmann kinetic and static perimetry Threshold, Fast Threshold, Advanced, Screening, 3-zone Flickering (CFF), Blue on Yellow (SWAP), BSV for testing diplopia Binocular Drivers Test (160 ) with Esterman standard score 4 stimuli colors: white, blu e, red, green Advanced analysis tools for easy diagnosis Advanced fixation control for high reliability Examination reliability can be estimated on the basis of false negative and false positive tests. Built-in digital camera allows eye-detection during examination and during setting patient's position. Thanks to pupil tracking system it allows a continuous automatic control of fixation. When patient loses fixation, blind spot is examined and special attraction mechanism turned on. Well known Heijl-Krakau method allows tracking of a blind spot and monitoring of examination reliability. All reliability indices are presented in examination results and on the printout. KINETIC TEST Thanks to kinetic strategy it is possible to examine hardly cooperating patients with big defects for whom static examination is difficult to perform. 4 stimuli colors, I-V Goldmann sizes, adjustable stimuli velocity, silent operation, built-in programs together with option of retesting arbitrary vectors defined by user make PTS1000 a top product for kinetic perimetry.

FLICKERING TEST The device also enables examination by means of flickering stimuli for CFF (Critical Fusion Frequency) measurement. CFF is used as an index of fatigue and it is clinically applied to neuro-ophthalmologic disorders derived from optic nerve disorder, especially for diagnosis and evaluation of glaucoma. COLOUR PERIMETRY PTS 1000 offers white, blue, red and green stimuli on white or yellow background. Except classic perimetry it enables to use "blue on yellow" (SWAP) examination method which utilizes fact of earlier loss of sensitivity to color based stimuli than to white-on-white stimuli based testing. Red color can additionally be used for diagnosis of toxic vision losses. BINOCULAR CAPABILITIES Implemented BSV strategy allows examination of diplopic areas. Testing of drivers is also possible thanks to included extended field, which enables testing field up to 80 degrees temporally and Binocular Drivers Test with Esterman score. INTERFACE Test result is presented as four easy-to-interpret graphic charts which contents can be freely selected from available analysis tools. Results can be presented in form of numerical maps of sensitivity in db, intuitive dot scale or color map for faster identification of out-of-norm regions. New interface allows easy follow up. It is possible to take a look into present and past examinations of one patient on one screen.

ANALYSIS TOOLS PTS 1000 in standard offers all analysis tools required to make a diagnosis. Age normative data and age norm deviation (total deviation) graph allow to quickly state condition of the patient. Bebie curve points the size and character of vision field defect while HoV and pattern deviation graphs highlight its irregularity. Overview window can be used to display previous examinations for long term analysis. STRATEGIES Examination strategies: Kinetic test Screening Threshold 3-zone Fast threshold BSV (Binocular Single Vision) Flicker (Critical Fusion Frequency measurement) BDT (Binocular Drivers' Test) Advanced OVERVIEW MODULE Overview module allows review of 5 different analysis graphs (5 columns) of up to 8 examinations simultaneously. User can freely select analysis tool and graph type. All this information can be printed or saved as image file. FIELDS 24 24/30 30 30 central 30 full 50 peripheral 30 50 macula 10 glaucoma 22 / 50 extended nas. 50 / temp. 80 fast 30 user defined 50 BDT Binocular Drivers' Test (80 horizontal, 50 vertical) PRINTOUT OPTS 1000 software has a new printout manager module. It gives great degree of freedom in deciding what should be on a printout and where it should be. Possibility to save own layouts as well as access to pre defined templates makes PTS 1000 software very powerful tool which is easy to handle even by non experienced operator. Printouts may look and contain information as Octopus' or Humphrey's depending on doctor's custom. PTS 1000

PTS 1000 Technical Data Examination bowl Tested field range Perimetry technique Stimulus size Stimulus colors 300 mm radius, closed type, vent ilated 100 (160 with fixation shift horizontally) Static, kinetic Goldmann Sizes I-V white, blue, red, green Automated Perimeter PTS 1000 Stimulus speed in kinetic perimetry Maximum Stimulus intensity Fixation method 2-10 /s 10000 asb control of blind spot position or digital detection of pupil position Patient response time adaptive to patient speed or set manually from 0,1 to 9,9s Background illumination Maps Strategies depends on stimuli type-31,5 asb for white and red stimuli, 10 asb for green, 314 asb yellow background for blue stimuli, set automatically 24 (24 with extent to 30 nasally), 30 (central 30 ), Full (50 in every directions) Central (30 in horizontal axis and 22 in vertical axis) Glaucoma (30 with extent up to 50 in nasal direction) Peripheral (from 30 to 50 ), Macula (up to 10 ) Extended (special field for drivers ex amination 50 in nasal direction; 80 in temporal direction), Fast (up to 30 with scarce points) Binocular Drivers Test (up to 80 in horizontal axis, up to 50 in vertical axis) User (up to 50 user defined) Kinetic, Screening, Threshold, 3-zone, Fast threshold, BSV (Binocular Single Vision), Flicker (Critical Fusion Frequency), Blue On Yellow (SWAP) BDT (Binocular Drivers Test), Advanced Reduced field option Neurological defects option Result maps Interface Dimensions Operating Voltage Additional features age norm deviation (total deviation), pattern deviation, hill of vision dev iation defect probability graph,defects progress analysis,,results overview Bebie curve, Pupil movement graph, 3D visualization of patients HOV. USB 693 x 585 x 444HxWxD 100-250V 50-60Hz Eye monitoring by means of built-in video camera. Advanced auto-detection of eye position. Automatic pupil diameter measurement. Automatically controlled chin-rest enables to set proper patient s position precisely and easily Printout manager with predefined printout styles. Network capabilities (remote database, networked review stations). Direct database back-up. Special ventilation system is used to keep fresh air throughout examination inside stimulation bowl

OPTOPOL Technology S.A. ul. Żabia 42, 42-400 Zawiercie, POLAND Tel/Fax: +48 32 6709173 info@optopol.com.pl www.optopol.com Marketed By: Enterprises BHOPAL (M.P.) Production & Development RAIPUR (C.G.) Healthcare KOLKATA (W.B.) HEAD OFFICE: Plot No. 50/1B - 50/2B, Akbarpura, Rajharsh Colony, Near Ram Mandir, Kolar Road, Bhopal - 462042 (M.P.) E-mail : info@mediequipbazar.com, mexbhopal@gmail.com, mexbhopal@yahoo.com Phone : 0755-4256391, Mo.: +919302778762, +917697842736 Website: www.mediequipbazar.com