100G SR4 TxVEC Update. John Petrilla: Avago Technologies May 15, 2014

Similar documents
Improved 100GBASE-SR4 transmitter testing

100G CWDM4 MSA Technical Specifications 2km Optical Specifications

Comment Supporting materials: The Reuse of 10GbE SRS Test for SR4/10, 40G-LR4. Frank Chang Vitesse

BERT bathtub, TDP and stressed eye generator

IEEE 802.3ba 40Gb/s and 100Gb/s Ethernet Task Force 22th Sep 2009

400G CWDM8 10 km Optical Interface Technical Specifications Revision 1.0

TDEC for PAM4 Potential TDP replacement for clause 123, and Tx quality metric for future 56G PAM4 shortwave systems

TDEC for PAM4 ('TDECQ') Changes to clause 123, to replace TDP with TDECQ Draft 1. May 3rd 2016 Jonathan King

TDEC for PAM4 ('TDECQ') Changes to clause 123, to replace TDP with TDECQ Draft 1a. May 3 rd 2016 Jonathan King Finisar

IEEE P802.3bs D Gb/s & 400 Gb/s Ethernet 4th Sponsor recirculation ballot comments

Multilane MM Optics: Considerations for 802.3ba. John Petrilla Avago Technologies March 2008

QSFP28. Parameter Symbol Min Max Units Notes Storage Temperature TS degc

100G 4WDM-10 MSA Technical Specifications 10km Optical Specifications Release 1.0

400G-FR4 Technical Specification

IEEE P802.3bs D Gb/s & 400 Gb/s Ethernet 4th Sponsor recirculation ballot comments

06-011r0 Towards a SAS-2 Physical Layer Specification. Kevin Witt 11/30/2005

Modal Noise and Implications for the CSRS Test

Low frequency jitter tolerance Comments 109, 133, 140. Piers Dawe IPtronics. Charles Moore Avago Technologies

TDEC, OMA and TDP Evaluation for 25G EPON

400G-BD4.2 Multimode Fiber 8x50Gbps Technical Specifications

TDECQ changes and consequent spec limits

IEEE P802.3bm D Gb/s & 100 Gb/s Fiber Optic TF 1st Sponsor recirculation ballot comments

QSFP SFP-QSFP-40G-LR4

PROLABS XENPAK-10GB-SR-C

T Q S Q 7 4 H 9 J C A

OFC SYSTEM: Design Considerations. BC Choudhary, Professor NITTTR, Sector 26, Chandigarh.

10GBASE-S Technical Feasibility

Product Specification 100GBASE-SR10 100m CXP Optical Transceiver Module FTLD10CE1C APPLICATIONS

100-Gbps QSFP28 SR4 Optical Transceiver Module PN: WST-QS28-SR4-C

T A S A 1 E B 1 F A Q

SMF PMD Modulation Observations. 400 Gb/s Ethernet Task Force SMF Ad Hoc Conference Call 24 February 2015 Chris Cole

Polarisation Mode Dispersion in 100GbE links

Introduction of 25 Gb/s VCSELs

Single Fiber, Single wavelength, GbE / FE transceiver ODN requirements & performance measurements ODN = Optical Distribution Network

Consideration about wavelength allocation in O-band

Single Fiber, Single wavelength, GbE link

IEEE P802.3bs D Gb/s & 400 Gb/s Ethernet 3rd Sponsor recirculation ballot comments

QSFP SV-QSFP-40G-PLR4L

Multimode fiber media types for 802.3cd

40G-QSFP-ER4-LEG. 40Gbase QSFP+ Transceiver

XENPAK-10GB-SR XENPAK-10GBASE-SR 850nm, 300m Reach

VCSEL Based 10 Gigabit Serial Solutions

T Q S Q 1 4 H 9 J 8 2

QSFP-40G-LR4-S-LEG. 40Gbase QSFP+ Transceiver

CFP2. Parameter Symbol Min Max Units Notes. Storage Temperature Ts degc. Relative Humidity (non-condensation) RH 85 %

Proposal for 400GE Optical PMDs for SMF Objectives based on 4 x 100G DMT David Lewis, Sacha Corbeil, Beck Mason

QSFP SV-QSFP-40G-LR4L

TDECQ update noise treatment and equalizer optimization (revision of king_3bs_02_0217_smf)

50Gb/s technical feasibility analysis. Dekun Liu, Huawei Stanley Shuai, Source Sep, 2017

Wavelength (nm) (m) ( o C) SPM-2100AWG 10.3 SR / SW 300 / 82 / 33* 850 VCSEL SFP+ with DMI -40 to 85 Yes

DATA SHEET: Transceivers

Signal metrics for 10GBASE-LRM. Piers Dawe Agilent. John Ewen JDSU. Abhijit Shanbhag Scintera

CFP4. Parameter Symbol Min Max Units Notes. Storage Temperature Ts degc. Relative Humidity (non-condensation) RH 85 %

T A S A 1 E H

Fibre Channel Consortium

Characterization and Compliance Testing for 400G/PAM4 Designs. Project Manager / Keysight Technologies

SRS test source calibration: measurement bandwidth (comment r03-9) P802.3cd ad hoc, 27 th June 2018 Jonathan King, Finisar

XQM859-M1PY. 100 Gb/s QSFP28 SR4 Optical Transceiver. XQM859-M1PY QSFP28 SR4 Optical Transceiver. Features

Clarifying Issues Related to Spreadsheet Model using Full Link Simulation for 25G on MMF

VCSEL Friendly 1550nm Specifications

SO-QSFP28-SR4. QSFP, 100GBASE-SR, 850nm, MM, MPO OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

Channel operating margin for PAM4 CDAUI-8 chip-to-chip interfaces

Additional PAM4 transmitter constraints (comments 52, 54, 57, 59, 27) 802.3cd interim, Pittsburgh, May 2018 Jonathan King, Chris Cole, Finisar

Dynamic Behavior of Mode Partition Noise in MMF. Petar Pepeljugoski IBM Research

Product Specification 100GBASE-SR10 100m CXP Optical Transceiver Module FTLD10CE3C

40GBASE-ER4 Ethernet Industrial: -40 C to 85 C. Infiniband QDR and DDR Four 10G DFB base CWDM channels on. Distance * (note2) Interface Temp.

Product Specification 40GBASE-LR4 Lite QSFP+ Optical Transceiver Module FTL4C1QL2C

IEEE P802.3bm D Gb/s and 100 Gb/s Fiber Optic TF Initial Working Group ballot comments

SECQ and its sensitivity to measurement bandwidth

Arista Networks QSFP-100G-SR4-AR. Part Number: QSFP-100G-SR4-AR QSFP-100G-SR4-AR OVERVIEW PRODUCT FEATURES APPLICATIONS.

This 1310 nm DFB 10Gigabit SFP+ transceiver is designed to transmit and receive optical data over single mode optical fiber for link length 10km.

DATASHEET 4.1. QSFP, 40GBase-LR, CWDM nm, SM, DDM, 6.0dB, 10km, LC

A comment on Table 88-7 and 88-8 in Draft 1.0

Arista QSFP-40G-PLR4. Part Number: QSFP-40G-PLR4 QSFP-40G-PLR4 OVERVIEW PRODUCT FEATURES APPLICATIONS FUNCTIONAL DIAGRAM.

Improvements to Modal Noise Penalty Calculations

Product Specification RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver

Keysight Technologies Greg LeCheminant / Robert Sleigh

06-496r3 SAS-2 Electrical Specification Proposal. Kevin Witt SAS-2 Phy Working Group 1/16/07

10GBASE-S Technical Feasibility RECAP

from ocean to cloud USING COHERENT TECHNOLOGY FOR SIMPLE, ACCURATE PERFORMANCE BUDGETING

Experimental Demonstration of 56Gbps NRZ for 400GbE 2km and 10km PMD Using 100GbE Tx & Rx with Rx EQ

PCI Express Receiver Design Validation Test with the Agilent 81134A Pulse Pattern Generator/ 81250A ParBERT. Product Note

SPQ-10E-SR-CDFG 40G QSFP+ Transceiver

X2-10GB-LR-OC Transceiver, 1310nm, SC Connectors, 10km over Single-Mode Fiber.

Modal noise in 100GBASE-SR4. Piers Dawe Mellanox Technologies. IEEE P802.3bm, October 2013 Modal noise in 100GBASE-SR4 1

SFP-10G-SR-Arista-A SFP+, 10GBASE-SR 10G Ethernet Module 850mn, 300m, MMF, LC RoHS6. Approved Optics, Inc.

MMF Channel Characteristics

SAS-2 6Gbps PHY Specification

Cisco QSFP-40G-SR4. Part Number: QSFP-40G-SR4 PRODUCT FEATURES APPLICATIONS. FluxLight, Inc

Product Specification 40GE SWDM4 QSFP+ Optical Transceiver Module FTL4S1QE1C

10GBd SFP+ Short Wavelength (850nm) Transceiver

QSFP, 40GBase-SR, 850nm, MM, MPO

QSFP28 Dual LC 100G SMF 2km Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

QSFP-100G-SR4-AR-LEG. 100Gbase QSFP28 Transceiver

Product Specification

40Gb/s QSFP+ esr4 Optical Transceiver Module QSFP-4000-ESR4. Product Specification

Arista 40GBASE-XSR4-AR. Part Number: 40GBASE-XSR4-AR 40GBASE-XSR4-AR OVERVIEW APPLICATIONS PRODUCT FEATURES. FluxLight, Inc

XENPAK-10GB-LRM XENPAK-10GBASE-LRM 1310nm, 220m Reach

BTI-10GLR-XN-AS. 10GBASE-LR XENPAK Transceiver,1310nm, SC Connectors, 10km over Single-Mode Fiber. For More Information: DATA SHEET

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

Transcription:

100G SR4 TxVEC Update John Petrilla: Avago Technologies May 15, 2014

Presentation Summary Presentation Objectives: Review/update proposed replacement for TDP Extracted from petrilla_01_0314_optx.pdf Review experimental results Extracted from petrilla_0101d0_0501 MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 2

100G 100 m SR4: A metric to replace TDP (1 of 6) AULH AURH OMA ALLH ALRH The chart on the left indicates that a TxVEC metric, where TxVEC is equal to the larger of the four quantities TxVEC(ULH) = -10Log 10 (2 x AULH - 1) where AULH is the signal amplitude at the 0.005th percentile level of the Upper Left Histogram TxVEC(URH) = -10Log 10 (2 x AURH - 1) where AURH is the signal amplitude at the 0.005th percentile level of the Upper Right Histogram TxVEC(LLH) = -10Log 10 (1-2 x ALLH) where ALLH is the signal amplitude at the 0.005th percentile level of the Lower Left Histogram TxVEC(LRH) = -10Log 10 (1-2 x ALRH) where ALRH is the signal amplitude at the 0.005th percentile level of the Lower Right Histogram is better aligned with link model margin than a TDP metric. Here histograms are taken at ± 0.10 UI offsets from the center of the eye. OMA is the signal amplitude measured with the OMA measurement method normalized to a unit amplitude of 1.0. Histrograms are used individually to cover non-symmetric waveforms, e.g. cases where the mean crossing point shifts from Pave. Note that there is no need for a reference transmitter for the TxVEC measurement. With the inability of TDP to predict link margin shown above, the use of a non-ideal Ref Tx to calibrate the Sensitvity of the Ref Rx is suspect. Also note that Fibre Channel uses a transmitter vertical eye closure metric, VECPq, for MMF transmitters and not TDP. MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 3

Updated: 100G 100 m SR4: A metric to replace TDP (1a of 6) AULH AURH OMA ALLH ALRH The equations for TxVEC on the previous page are here updated to reflect better the effect of non-symmetrical waveforms. Instead of a normalized OMA, power levels, P(1), for the high level, P(0), for the low level and Pave (average LOP) are used. As before TxVEC is equal to the largest of the four quantities: TxVEC(ULH) = 10Log 10 ((P(1) - Pave)/(P(D) Pave)) where P(D) is the power at the 0.005th percentile level of the Upper Left Histogram TxVEC(URH) = 10Log 10 ((P(1) - Pave)/(P(A) Pave)) where P(A) is the power at the 0.005th percentile level of the Upper Right Histogram TxVEC(LLH) = 10Log 10 ((Pave P(0))/(Pave P(C))) where P(C) is the power at the 0.005th percentile level of the Lower Left Histogram TxVEC(LRH) = 10Log 10 ((Pave P(0))/(Pave P(B))) where P(B) is the power at the 0.005th percentile level of the Lower Right Histogram As before histograms are taken at ± 0.10 UI offsets from the center of the eye. OMA, P(1) and P(0) are the signal amplitude and high and low levels measured with the OMA measurement method. MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 4

100G 100 m SR4: A metric to replace TDP (2a of 6) Proposed replacement text for 95.8.5 95.8.5 Transmitter Vertical Eye Closure Transmitter Vertical Eye Closure (TxVEC) shall be as follows: a) Each optical lane is tested individually with all other lanes in operation. b) The transmitter is tested using an optical channel with an optical return loss of 12 db. c) Average launch power, Pave, shall be measured as defined in 95.8.3. d) OMA and nominal 1 and 0 levels shall be measured as defined in 95.8.4. e) The transmit eye is observed as defined in 95.8.7 with the following exception: eye mask coordinates are not applied. f) The transmitter optical waveform is measured for vertical eye closure (TxVEC) with vertical histograms at ± 0.1 UI from the eye center. TxVEC is the larger of the four quantities: TxVEC(ULH) = 10Log 10 ((P(1) - Pave)/(P(D) Pave)) where P(D) is the power at the 0.005th percentile level of the Upper Left Histogram TxVEC(URH) = 10Log 10 ((P(1) - Pave)/(P(A) Pave)) where P(A) is the power at the 0.005th percentile level of the Upper Right Histogram TxVEC(LLH) = 10Log 10 ((Pave P(0))/(Pave P(C))) where P(C) is the power at the 0.005th percentile level of the Lower Left Histogram TxVEC(LRH) = 10Log 10 ((Pave P(0))/(Pave P(B))) where P(B) is the power at the 0.005th percentile level of the Lower Right Histogram g) The test setup illustrated in Figure 52-9 shows the reference method. Other measurement implementations may be used with suitable calibration. h) TxVEC is defined for each lane, at the BER specified in 95.1.1 and is for the lane under test on its own. See 95.8.1.1 for multi-lane pattern considerations. NOTE Sampling instant offsets have to be calibrated because practical receivers and decision circuits have noise and timing impairments. One method of doing this is via a jitter bathtub method using a known low-jitter signal. MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 5

Updated: 100G 100 m SR4: A metric to replace TDP (3a of 6) Based on the new metric TxVEC, in Draft 2.0 replace in Table 95-6, Transmitter and dispersion penalty (TDP), each lane (max) = 5 db with Transmitter vertical eye closure, each lane (max) = 5 db in Table 95-6, Launch power in OMA minus TDP (min) = -8 dbm with Launch power in OMA minus TxVEC (min) = -8 dbm in Table 95-6, Optical Modulation Amplitude (OMA), each lane (min) b = -7.1 dbm with Optical Modulation Amplitude (OMA), each lane (min) b = -7.1 dbm in Table 95-6, footnote b, Even if the TDP < 0.9 db, the OMA (min) must exceed this value. with Even if the TxVEC < 0.9 db, the OMA (min) must exceed this value. in Table 95-8, Power budget (for max TDP) = 8.2 db with Power budget (for max TxVEC) = 8.2 db in Table 95-8, Allocation for penalties (for max TDP) = 6.3 db with Allocation for penalties (for max TxVEC) = 6.3 db MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 6

New: 100G SR4: TDP & TxVEC Test Setups The above drawings show setups for measurement of TDP and TxVEC. Significant differences include: Tx VEC setup does not need a Reference Transmitter. Reference Receiver for TxVEC can be an oscilloscope with an optical plug-in. Setup and calibration of the TxVEC setup is expected to be significantly easier. TDP requires calibration of: Optical channel for 12 db optical return loss Reference Transmitter for TDP Reference Receiver for bandwidth and filter frequency rolloff BERT sampling offset TxVEC requires calibration of: Optical channel for 12 db optical return loss Oscilloscope eye for histogram placement MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 7

Review: 100G 100 m SR4: A metric to replace TDP (5 of 6) Transmitter and dispersion penalty (TDP) Summary TDP results for MMF cases are not well aligned with margin calculations from the link model. TDP measurements require either an ideal reference transmitter or the ability to calibrate a reference for TDP with respect to the ideal. Since TDP results are not well aligned with link model margin, such a calibration seems problematic. Under estimating the TDP of the Ref Tx is easy, perhaps common, permitting test escapes. TDP requires a reference receiver with a non-standard BW that will need setup and calibration. The complexities with TDP has limited its acceptance and use in the industry. Since a TDP result is the difference between two optical Rx sensitivity measurement results, its accuracy and repeatability is driven by the accuracy and repeatability of optical Rx sensitivity measurements. Accuracy and repeatability of key attributes, such as TDP, are critical issues for operating life and other reliability tests where parametric drift is examined, setting tester guard bands and for correlating results between vendors and customers. TDP requiring bit error detection and counting places restrictions on test patterns. Transmitter Vertical Eye Closure (TxVEC) Summary TxVEC results for MMF cases are better aligned with link model margin than TDP results, promising a better balance of test escapes with rejecting acceptable devices. TxVEC does not require a reference transmitter. The Ref Rx for TxVEC can be an oscilloscope with a standard optical plug-in for the 25G signal rate. TxVEC uses the same test setup as Tx eye mask test and RIN12OMA and same techniques as SRS VECP; no new equipment or techniques are needed. MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 8

New: 100G 100 m SR4: A metric to replace TDP (6a of 6) TxVEC provides better results for MMF cases than TDP while using a simpler and friendlier test setup that is more likely to be adopted in the industry. The simpler and friendlier test requirements for TxVEC make it a preferable test even if TDP provided comparable results. 802.3bm should replace TDP with TxVEC. MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 9

100G SR4 TxVEC Experimental Results An experiment was set-up at Avago Technologies to measure TxVEC on a set of 25G transmitters (Tx) and compare the results with the results of receiver sensitivity, RxS, measurements made using the same Tx set. The above left chart from prior presentations, shows the expected correlations to link margin for the metrics TDP and TxVEC. The charts to the right show correlations of emperical results for TxVEC with RxS margin for cases of minimum reach (B2B) of fiber and a worst case 100 m OM4 fiber; actually 110 m of 5022.7 MHz km EMB fiber. RxS margin is used as an analogue for link margin. MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 10

100G SR4 TxVEC Measurements The above image shows the attributes as measured in the experiment. MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 11

Tx Output Eyes for Experimental Tx Set (1 of 2) Tx20 Tx21 Tx22 Tx23 Tx24 Tx25 Eyes using a 25GbE optical plug-in are shown above for six of the experimental transmitters. The 802.3bm D2.2 Cl 95 eye mask is included to help judge eye quality. Drive conditions for the transmitters were tuned to produce certain eye characteristics and the eyes are not representative of normal devices. MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 12

Tx Output Eyes for Experimental Tx Set (2 of 2) Tx26 Tx27 Tx28 Devices T20, T24, T25 & T28 waveforms appear the most Gaussian with eyes that appear the most symmetrical. Tx29 Tx30 Eyes using a 25GbE optical plug-in are shown above for five of the experimental transmitters. The 802.3bm D2.2 Cl 95 eye mask is included to help judge eye quality. Drive conditions for the transmitters were tuned to produce certain eye characteristics and the eyes are not representative of normal devices. MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 13

Correlation of 100G SR4 TxVEC results with RxS results The above charts shows the correlation between TxVEC and RxS margins for B2B and 110 m OM4 cases. MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 14

Correlation of 100G RxS results for B2B & 110 m OM4 cases The left chart shows a range of ~ 1.8 db for RxS(OM4) margin & RxS(B2B) margin result pairs. The range includes the variation between two RxS measurements and the effect of the OM4 fiber. It s accepted in the industry that a range of 1 db for RxS repeatability is very tight. In the right chart a range of ~ 2.7 db for RxS(OM4) margin is shown for all transmitters with positive TxVEC margin. For the Gaussian group, T20, T24, T25 & T28, the range is 0.70 db. The ability to predict worst case 100G SR4 link performance based on TxVEC results appears reasonably aligned with simulations for the Gaussian group, less so for the entire group. Fortunately, link margin estimates are conservative for most of the non-gaussian group.. Since link margin estimates based on TxVEC results appear to be within the range of errors found for link margin estimates based on TDP results and TxVEC is a significantly easier measurement to implement, 802.3bm should replace TDP with a TxVEC metric. MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 15

Correlation of 100G SR4 TxVEC & Eye Mask Margins The above chart shows the correlation between Tx Eye Mask margin results and TxVEC margin results, provided to show the range of eye quality included in this experiment. MMF ad hoc May 15, 2014 Avago Technologies: 100G SR4 TxVEC Update 16