Hard wearing and durable Quick and easy to install Fully adjustable for batten gauges of mm

Similar documents
15 YEAR GUARANTEE. Tough and long lasting Guaranteed waterproof for 15 years Economical and easy to fix AVAILABLE IN A RANGE OF COLOURS

15 YEAR GUARANTEE. Made from lightweight high grade steel with Aluzinc coating for incredible strength and weather protection

video 10 YEAR GUARANTEE Durable and lightweight Guaranteed waterproof for 10 years Economical and easy to fix AVAILABLE IN A RANGE OF COLOURS

INSTALLATION GUIDE ECONOMICAL PVC CLADDING SHEET IDEAL FOR WALLS & CEILINGS 10 YEAR GUARANTEE

10 YEAR GUARANTEE. Vistalux corrugated sheeting is the ideal general purpose PVC sheet for roofing and cladding PVC SHEET WITH HIGH LIGHT TRANSMISSION

Installation guide for 20/20

Sandtoft installation guides

Roll-Fix Kit The complete dry hip kit RFIG

Flat Glazing FLEXIBLE LIGHT IN WEIGHT RANGE OF SIZES. Acrylic Sheet Exterior Polystyrene Sheet Interior Grade Solid Polycarbonate Sheet

NEW equinox INSTALLATION GUIDE Issue

NEW equinox INSTALLATION GUIDE Issue

manthorpe Roll-Out Dry Fix Ridge System building products Fixing Instructions MBP 8265e

Dry Verge System. For more information on CEMEX visit

ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION

INSTALLATION GIUDE.

Shingle Installation Guide

PV SLATE ROOF INSTALLATION GUIDE

Roofstyle. touch. the individual. touch BUILDING PRODUCTS

Assembly Instructions

COMPOSITE SIDING INSTALLATION GUIDE

PEDESTAL INSTALLATION. Guidelines for installing adjustable height pedestals

Installation Guide. Guardian Slate Roof System. England, Scotland & Wales

Tuff-Rib Install Guide

GV Standard PitchVent

Installation Guide (888)

NewTech - CleverDeck Composite Decking Installation Guidelines

INTRODUCTION Tools Required Laminate Washroom Products... 4 DUCT PANELS Fixing the Frame: Fixing the Shadow Panels...

SpeedDeck. Fixing and Handling Guide

ASSEMBLY INSTRUCTIONS GG77. BASE SIZE: 2.190m x 2.020m

Greenhouse Assembly Instructions

Assembly Instructions

WARNING Please refer to all safety notices in the greenhouse manual before assembling any of the sections

Ram Promaster Rack. Installation instructions for

ASSEMBLY INSTRUCTIONS SS2010. BASE SIZE: 2.020m x 1.020m

Blackout Instructions. 4 R-Series Fascia Installation Outside Mount

Bird Spike Installation Guide

EASY INSTALLATION GUIDE WPC DECKING.

INSTALL IN 2 DAYS. *Assumes 3-man fitting team. equinox. Tiled roof system. Installation guide ISSUE 1

S H E D A S S E M B L Y I N S T R U C T I O N S

Gambrel Barn with Overhang Manual

Installation Instructions

Installation Guide (888)

E N G L I S H GARDEN SHED. Assembly Instructions. Suitable for Models WITH VARYING DEPTHS

Installation Guide 2016

FOR GUIDING THE ROUTER

ALPINE TRAY. To get the best from this product please follow these recommendations.

gabriel ash essential range

Siding Components. Installation Guide

Stone coated steel roof tile INSTALLATION GUIDE

Gardman Lean-to Greenhouse Assembly Instructions

FIXING GUIDE. Designed for Garages & Sheds, Houses, DIY, Flat Roofs, Industrial & Agricultural Buildings etc. IS THE LONG TERM ROOFING SOLUTION

Installation guide. Step-by-step instructions

ASSEMBLY INSTRUCTIONS SS2520. BASE SIZE: 2.520m x 2.020m

CLIP RANGE & COMPATIBILITY TAKE A CLOSER LOOK. Part of BMI GROUP

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

Contents. Stage 1. Preparation of the aperture 9. Interior finishing 25

COMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE

S H E D A S S E M B L Y I N S T R U C T I O N S

Chapter 16: Roof Steel

PROFESSIONAL PITCHED ROOFING ANCILLARIES

How to install soffit VENTILATION. How to begin

INSTRUCTIONS FOR ASSEMBLY 2355mm x 3125mm Workshop

technical bulletin Roofline Installation Details No.7 Fascia Installation Details Typical Eaves Details K16 Fascia & 9mm Vented Soffit

Pocket Door Kit PD1 / PD2 Installation Instructions. Kit Contents.

Installation Guide Simplicity Alfresco. V1.9 Lu070318

INSTRUCTIONS FOR ASSEMBLY 2355mm x 4665mm Workshop

FITTING INSTRUCTIONS

technical bulletin Roofline Installation Details No.7 Fascia Installation Details Typical Eaves Details K16 Fascia & 9mm Vented Soffit

TREX SELECT RAILING. Installation Instructions PARTS

Installation Instructions Please pass on to user

NEVADA ASSEMBLY INSTRUCTIONS

SecuAnch Roof Anchor System

White Black Espresso Corner Desk Assembly Instructions

IMPORTANT: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE

I. Architectural drawings. Pod 4x3 LTH (34)

ATLANTIS RAIL Contact Information

Calf-Tel Pen System Assembly Instructions

900 SERIES WALL PANELS

Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.

IDAHO ASSEMBLY INSTRUCTIONS. BASE SIZE: 1.800m x 1.200m

DUTCH GABLE FREESTANDING CARPORT

Assembly Instructions 10 X 10 Aluminum Roof Support

CONSTRUCTION GUIDE 27ft Wide and 30ft Wide SHEEP HOUSE

INSTALLATION GUIDE DUOFUSE SLAT WALL SYSTEM

CROWN IMPERIAL ASSEMBLY INSTRUCTIONS

CELLBOARD DECK CLIP FIXING INSTALLATION MANUAL CBWD14525

Chapter 12 - Windows and Doors

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

Furniture Fittings Concealed Hinges

ROOF Drainage System Creating Waterfall. Made in Sweden

SHOWERLUX HELPLINE: TEL: SHOWERLUX (UK) Ltd.

Assembly Instructions

IMPORTANT -- SPECIAL INSTALLATION INSTRUCTIONS

gabriel ash essential range

ASSEMBLY INSTRUCTIONS FOR STORETTE STA42

GV Standard Pitchglaze

TREX ENHANCE RAILING (Also Applies to Trex Select Railing) Installation Instructions

EASY SLATE FIXING GUIDE

HILAND TRAY FORM AND FUNCTION MATERIAL SPECIFICATIONS DESIGN GUIDE ROOFING I WALLING

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

Transcription:

INSTALLATION GUIDE Watch the installation VIDEO arielplastics.com Hard wearing and durable Quick and easy to install Fully adjustable for batten gauges of 260-350mm www.arielplastics.com

Coroverge is a mortar free dry verge system which acts as a closure on the roof verge of houses, garages and porches to protect tiles from wind uplift, pest infestation and weather degradation in accordance with BS 5534. Combining strength and resilience with an attractive finish, the Coroverge Dry Verge System is also available in a selection of popular colours depending on the application. 100% mortar free dry fix verge Fully adjustable for batten gauges of 260-350mm Hardwearing and durable Quick and easy to install Selection of popular colours IMPORTANT Please follow the fitting instructions carefully. Ensure all appropriate equipment is used in accordance with relevant health & safety regulations. Starter Piece Verge Section Round Ridge Cap True Mount Angled Ridge Cap True Connect Locators

Standard Installation Procedure The standard installation procedure should be used for new builds; for retrofitting the Coroverge System or for high wind load installations the installer should complete the additional installation tips at the end of this document. 1 Preparation Install the batten clips onto the end of each tile batten. a) Place the batten clip over the end of the tile batten so that the slot sits in the centre of the batten. b) Fix the clip in place by nailing 2 x 20mm length x 2.65mm diameter nails through the holes on the top of the clip into the tile batten. b a 2 Starter Piece a) Place the Starter Piece into the Verge Section and slide into the locked position. b b) Remove the True-Line guide which will not be used depending on which side of the roof where installation is taking place. a 3 Fitting the first Verge Section Fit the Starter and Verge combination onto the first tile. If the gutter prevents the Starter Piece from sitting in the correct place, cut down the pre-marked cut lines to remove the face of the Starter Piece, always cut away from the body and wear appropriate PPE. Cut out Using the True-Line guide screw the Starter Piece into position (small temporary screws should be used). Slide the Verge Section off the tile leaving the Starter Piece in place.

Using 2 x Pozi Round Head 20mm length x 3.5mm diameter screws mount the Starter Piece to the fascia (it may be necessary to add a packer between the Starter Piece and the fascia if the tile overhang exceeds 52mm). Remove both the temporary screws and discard the True-Line guide by bending it upwards until the snap-off feature breaks. Place the Verge Section back onto the Starter Piece and slide into the locked position. Using a 60mm nail, nail the Verge Section into the tile batten. This is achieved by nailing through the Verge Section fixing holes, through the batten clip slot and into the tile batten. 4 Fitting the remaining Verge Sections Open the flexible tabs at the end of the next Verge Section to allow it to fit over the previously installed Verge Section (the tabs should be first bent inwards and then flexed open). Position the next Verge Section to line up with the end of the next tile. Ensure that the True Connect locators fit into the True Mount of the preceding Verge Section. Adjust the flexible tabs to close off any gap between the Verge Sections. Repeat until Verge Sections reach the ridge tile. True Mount True Connect Locators

5 Fitting the Ridge Cap Once both sides of the roof are complete place the Ridge Cap over the ridge tile so that it sits between the 2 verges. The flexible tabs on the ridge cap will allow it to fit with the Verge Sections installed at a number of different angles. Using the 2 x 80mm pan head screws provided, select 2 appropriate fixing holes on the ridge cap, screw through the ridge cap and into the fascia board. Retro Fitted Installations If the roof has a mortar bedded verge, first remove the existing mortar. Inspect the tile battens for signs of rot or damage and if necessary they should be replaced, extended or repaired. If only the ends of the tile battens are damaged it may be possible to replace the end of the tile batten by securely fixing a short length of replacement batten to the existing batten. Once any necessary repair work has been completed on the tile battens the standard installation procedure can be followed. High Wind Areas In areas where the roof system is likely to encounter higher than normal wind loads, use the extra fixing point provided inside the verge sections for added support. Select the screw position which will have the fascia board directly behind it. Pre-drill a hole through the extra fixing point using a 4mm drill bit. Continue with the standard installation procedure then complete this additional step: Fix an additional 80mm pan head screw through the extra predrilled hole and into the fascia board, taking care not to over tighten the screw.

Contact our sales team: Tel: 01246 281111 Orderline Email: sales@arielplastics.com or visit www.arielplastics.com Coroverge Fixing Requirements: Component Fixings Required Quantity Supplied Starter Piece Dry Verge Section Pozi Pan 20mm (length) x 3.5mm ø 2 Yes Small temporary screws 2 No Stainless Steel Batten Clip 1 Supplied 25mm (length) x 2.65mm ø Stainless Steel Nail 2 separately in batten 60mm (length) x 3.35mm ø Stainless Steel Nail 1 fixing pack Angled Ridge Cap Pozi Pan 80mm (length) x 5mm ø 2 Yes Round Ridge Cap Pozi Pan 80mm (length) x 5mm ø 2 Yes Batten Fixing Pack (supplied separately): Fixings Required Quantity Included Stainless Steel Batten Clip 10 60mm (length) x 3.35mm ø Stainless Steel Nail 1 25mm (length) x 2.65mm ø Stainless Steel Nail 20 Ariel Plastics Ltd Speedwell Industrial Estate Staveley Derbyshire S43 3JP Tel: 01246 281111 Fax: 01246 561111 Email: info@arielplastics.com Web: www.arielplastics.com APL041-5142-0218