MODULAR LED UNDERCABINET LIGHTING SYSTEM Max 540watts IMPORTANT SAFETY INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS Xenix Incandescent Series XN12, XN24, XN36, XN48

GLASS GLOBE MOBILE LINEAR CHANDELIER

Page 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A.

GLASS GLOBE MOBILE 6-ARM CHANDELIER

Arched Top Lantern Pendant Assembly and Installation Instructions. Country of Destination: US/CN UK/EU/AUS Middle East

MaxLite Linear Strip ECO Series

IMPORTANT SAFETY INSTRUCTIONS:

INSTALLATION INSTRUCTIONS

-Always de-energize the circuit and/or equipment before connecting to, disconnecting from or servicing the equipment.

WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY AND KEEP A COPY ON THE PROPERTY FOR FUTURE REFERENCE!

Custom Pendant- Hardwire Assembly and Installation Instructions

Installation Manual MODEL AE-46

Figure A. Figure B. Figure C. Figure D

Installation. Instructions. Built-In Microwave/Convection and Microwave Ovens. Models ZMC1095 JEB1095 JEB1055

IMPORTANT SAFETY INSTRUCTIONS:

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

General Installation Instructions

PARTS ENCLOSED: (A) Wall anchor (1) (B) Wall screw (1) (C) 4W Type G Bulb (1) (included)

MODELS: AE46, AE42, E46, E42, ANE46, ANE42, NE46, NE42

Inigo Sconce INSTALLATION INSTRUCTIONS P _2_A 1 of 5

ROPE CHANDELIER - FRAME ASSEMBLY & INSTALLATION INSTRUCTIONS

HP 2 SERIES Integral Driver - Solid State LED

MADELINE METAL CHANDELIER

Installation Instructions

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE:

Installation Guide. VONN Lighting Model: VMC Parts List. Circuit Box. Tools You May Need

Installation Manual MODEL E-42

F5513 APOGEE 30"DIA 3LTS PENDANT INSTALLATION INSTRUCTIONS WARNING

PORTA~TRACE. GAGNE, INC. 41 Commercial Dr. Johnson City, New York Phone: Fax: ASSEMBLY INSTRUCTIONS

Nash Chandelier Assembly and Installation Instructions

IMPORTANT SAFETY INSTRUCTIONS:

Section 7 Inteli-Touch Series Casablanca Fan Co. - Factory Service Department - Technical Library

Installation Instructions

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

Allegro Home Office Assembly Instructions. Tipping Restraint. Bun Foot W/ Leveler. 4 pcs.

Aliante Installation. Components included: Tools required: Not Included:

IMPORTANT SAFETY INSTRUCTIONS: -We strongly recommend that a professional electrician install all direct wire fixtures.

INSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST. MFL _00

EOS Direct/Indirect LED Pendant Luminaire

Single Sided Height Adjustable Benching

REGATTA PATH LIGHT (RGP)

Riverside. Windward Bay EntertaInment Wall System Assembly Instructions. Made In Viet Nam. Right Pier. Bridge & Back Panel.

Installation Instructions For Slider Casement Air Conditioners

A-dec 6300 Ceiling-Mount Dental Light INSTALLATION GUIDE

B235 Mobius Sconce Page 1 of 6

Installation Instructions

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

CAUTION: BEFORE INSTALLING THE LUMINAIRE, MAKE SURE THAT THE CURRENT IS CUT TO THE BOX FUSES / MAIN CIRCUIT BREAKER.

Installation Instructions. Materials Needed. Parts Included. Tools You Will Need

Installation Instructions

BEFORE YOU BEGIN Read these instructions completely and carefully.

Lightplane 3.5 Recessed

OPERATOR'S MANUAL RULES FOR SAFE OPERATION

GE Monogram. Installation. Instructions. 27" Built-In Ovens. Models ZEK757WW ZEK757BW ZEK737WW ZEK737BW

Installation Instructions

INSTALLATION MANUAL SFM2

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER

Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.

INSTRUCTIONS. _rowave Hood Combination Combinaci6nMicroondasCampana

Assembly Instructions Nevins Phone Booth

FRAMED CABINETRY INSTALLATION MANUAL

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

EOS LED Surface Mounted Luminaire

INSTALLATION MANUAL VERITY. friant.com/verity

Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS

Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.

Interra Installation Manual

PORTABLE HALOGEN WORK LIGHT OWNER S MANUAL

Installation Instructions

INSTALLATION MANUAL PBL-UMP

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System

GE Monogram. Installation. Instructions. Microwave Oven. Under Cabinet Installation. and. JX827 Series Built-In Kit. Models.

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

Installation Instructions

PRODUCT MANUAL 5-IN-1 MITER SAW STATION *SAVE THIS MANUAL FOR FUTURE REFERENCE

A500 ASSEMBLY & INSTALLATION INSTRUCTIONS

2004-(Z Series) HDILA Lamp Replacement Procedure Quick Step Guide

Installation Manual. Jandy Housing for Wet Niche Fixtures WARNING. For Vinyl and Fiberglass Pool Installations Model No.

Installation Manual REbus Beacon. Part of the Pika Energy Island M

Nocturne+ E INSTRUCTIONS CAUTION. Motor Operated Exterior Projection Screen. 1¾ (45mm) END CAP. Wall Mounting Bracket. Wall Mounting Bracket

Assembly Instructions Nevins Phone Booth

ZHONGSHAN KOHLER SHOWER CO., LTD. NO13-1, XINGYE ROAD, ZHONGSHAN TORCH DEVELOPMENT ZONE, ZHONGSHAN, GUANGDONG, CHINA POST CODE:

LINESSE LINEAR LUMINAIRE 3 CEILING MOUNT CM2420

Round or Square Chicago Plenum Down Light Housing with Lamp

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

Mirage Installation Manual

How to change the firmware EPROM in ALPHA signs

Assembly Instructions

LED Gas Station Light Installation Guide

Jarvis standing desk. Assembly instructions. For assembly assistance, visit fully.com/howtojarvis or call or

Installation Instructions

UP tables & worksurfaces

This instruction manual is an in-depth look and explanation of how to assemble and install the Murphy Bed properly and efficiently.

BEFORE YOU BEGIN Read these instructions completely and carefully.

LED MIRROR CABINETS 3612-L-6560

INSTALLATION MANUAL PBC-UMS

MESO X1 TBAR SEMI-RECESSED

Transcription:

MODULAR LED UNDERCABINET LIGHTING SYSTEM Max 540watts IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS GENERAL 1. To insure the success of the fixture installation, the following instructions and diagram(s) should be read and understood. All electrical connections must be made in accordance with the National Electric Code and local codes and ordinances. Only a qualified licensed electrician should install this fixture. 2. TOOLS NEEDED: Medium common screwdriver, medium and small Phillips screwdriver, wire cutter/stripper, electrical current tester, pencil, small drill or awl. (Screws for mounting the fixture to a wood cabinet are supplied) 3. WARNING To reduce The risk of FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS -Do not operate this fixture with a damaged or missing lens. -Do not touch hot lens. -Do not remain in light if skin feels warm. -Do not look directly at lamp if lit. Caution Injury to persons and damage to the luminaire and/or mounting surface may result if the luminaire is pulled from the surface. To reduce the likelihood of such injury or damage, mount this luminaire on a surface that is mechanically sound. SAVE THESE INSTRUCTIONS! INSTALLATION: 1. TURN OFF THE ENTIRE ELECTRICAL CIRCUIT TO WHICH THE LIGHTING FIXTURE IS TO BE ATTACHED. Move the circuit breaker to the OFF position or completely remove the fuse controlling the circuit. 2. Determine the desired location for mounting the fixture. Measure the distance between the Centers of the 2 keyholes on the back of the fixture. Mark the locations of the keyholes on the underside of the cabinet with a pencil. Drill pilot holes for the mounting screws with a small drill or awl. Start tightening the mounting screws into the cabinet, leaving the heads of the screws approx. ¼ away from the cabinet. Note: If you plan on joining fixtures end to end in a run, remove the safety covers with a common screwdriver on each of your fixtures. Align the ends of the fixtures and press the quick-link firmly together on all of the fixtures in your run. Measure the distance between all of the keyholes in your run. Mark these locations and Drill pilot holes. Determine the desired Power Feed for your fixture, Portable, Hardwire or Master Switch Cat. # NCS-1. Note: fixtures come pre-wired as portable, if you plan on using this fixture as a portable skip to Step 6. Portable: To be used with cord and plug. Cord and Plug Cat. # s, PL-96WH and PL-96BK (Sold Separately) Hardwire: To be used with Flex, Romex & Rigid Conduit (Provided by others) Master Switch: See master switch instructions (Sold separately)

Single fixture mounting dimension End to End or Speedlink mounting dimensions 3. If hardwiring, remove the lens pressing down on the ll> symbol on each end of the glass lens and pull forward. Remove the wireway cover by removing the two screws on opposite ends of the fixture and compressing the wireway tabs. Remove the desired knockout from the back of the fixture and install the conduit/romex clamp/connector. 4. Feed the supply wires through the fixture into the wireway compartment. Mount the fixture to the cabinet. Do not tighten the screws at this time. There will be 3 push-in quick connectors located in the wireway compartment, 1 common (white), 1 hot (black), and 1 ground (green). Connect the black supply wire to the black push-in connector, white to white and green to green. 5. Adjust the supply leads inside and outside of the fixture. Tighten the screws on the conduit/romex clamp. Replace the wireway cover removed in step 3. REMOVE PUSH IN WIRE CONNECTORS 6. Securely tighten the mounting screws. Note: If mounting end to end the entire run must be mounted together. Connect each fixture end to end and mount to the cabinet as a run. When adding additional fixtures to a portable fixture, they only can be added to the right of your power feed fixture. When adding additional fixtures to a hardwire fixture, they can be added on both the left and the right of your power feed fixture. 7. Replace the lens on your fixture(s). 8. If your power feed fixture is being used as a portable unit plug in your portable cord & plug into the left end of your power feed fixture and then into the outlet providing power to your fixture(s). 9. When using the Speedlink Cables to join fixtures together, follow step 1-3 and steps 7-9 to install additional fixture(s). Make sure all of your fixtures are securely tighten to the cabinet. Join the fixtures with the Speedlink cables. 10. Restore power to the circuit at fuse or breaker box. Note: Once power is restored never use SPEEDLINK cables to disconnect power. If disconnecting fixtures or cables is required, the power must be shut off at the fuse or breaker box first. End to End linking Speedlink Cables linking (Cat. # s QL-10BK, QL-10WH, QL-18BK, QL-18WH (Sold Seperately)

PORTABLE PRESET HARDWIRE CONVERSION