Supplementary information for. Video imaging of walking myosin V by high-speed atomic. force microscopy

Similar documents
SUPPLEMENTARY INFORMATION

Dynamic proportional-integral-differential controller for high-speed atomic force microscopy

Supplementary Figure S1: Schematic view of the confocal laser scanning STED microscope used for STED-RICS. For a detailed description of our

Supporting Information: Electron Microscopic Visualization of Protein Assemblies on Flattened DNA Origami

SUPPLEMENTARY INFORMATION

Contents. 1. Supplementary figures Supplementary Table Supplementary Methods Supporting movie list...

Prepare Sample 3.1. Place Sample in Stage. Replace Probe (optional) Align Laser 3.2. Probe Approach 3.3. Optimize Feedback 3.4. Scan Sample 3.

Supplementary Information: Nanoscale. Structure, Dynamics, and Aging Behavior of. Metallic Glass Thin Films

Circular Dichroism Microscopy Free from Commingling Linear Dichroism via Discretely Modulated Circular Polarization

Supplementary Figure 1 High-resolution transmission electron micrograph of the

Supporting Information. Atomic-scale Spectroscopy of Gated Monolayer MoS 2

Supplementary Information

Supporting Information for DNA Origami and G- Quadruplex Hybrid Complexes Induce Size- Control of Single- Walled Carbon

III III 0 IIOI DID IIO 1101 I II 0II II 100 III IID II DI II

Supplementary Material (ESI) for Lab on a Chip This journal is The Royal Society of Chemistry 2011

Get the full picture of your sample. Applications

Nanovie. Scanning Tunnelling Microscope

Atomristor: Non-Volatile Resistance Switching in Atomic Sheets of

Resolution. Diffraction from apertures limits resolution. Rayleigh criterion θ Rayleigh = 1.22 λ/d 1 peak at 2 nd minimum. θ f D

Chapter 2 The Study of Microbial Structure: Microscopy and Specimen Preparation

Electron Trajectories in Scanning Field-Emission Microscopy (SFEM) Scanning Field- Emission Microscopy

Supplementary information for Subnanometer structure and function from ion beams through complex fluidics to fluorescent particles

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons

Electronic Supplementary Information

Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros

Supplementary Figures

Lecture 20: Optical Tools for MEMS Imaging

Development of Si/SiO 2 Multilayer Type AFM Tip Characterizers

Supplementary Figures

A scanning tunneling microscopy based potentiometry technique and its application to the local sensing of the spin Hall effect

Supplementary Figure 1 Single-channel conductance of NaK after reconstitution into lipid bilayers at various membrane potentials.

Image Evaluation and Analysis of Ink Jet Printing System (I) - MTF Measurement and Analysis of Ink Jet Images -

Individually color-coded plasmonic nanoparticles for RGB analysis

A Project Report Submitted to the Faculty of the Graduate School of the University of Minnesota By

Supplementary Information

A Novel Transform for Ultra-Wideband Multi-Static Imaging Radar

Microscopy Techniques that make it easy to see things this small.

Supporting Online Material for

Uncertainty in measurements of micro-patterned thin film thickness using Nanometrological AFM - Reliability of parameters for base straight line -

Figure for the aim4np Report

Scanning Tunneling Microscopy

photolithographic techniques (1). Molybdenum electrodes (50 nm thick) are deposited by

Author(s) Issue Date Text Version author. DOI / /18/9/095501

Approachable Raman Solutions The Shortest Path from Problem to Answer

Review Energy Bands Carrier Density & Mobility Carrier Transport Generation and Recombination

Supplementary Information. Stochastic Optical Reconstruction Microscopy Imaging of Microtubule Arrays in Intact Arabidopsis thaliana Seedling Roots

What you should have learned from the microscope labs.

Supplementary Figure S1 X-ray diffraction pattern of the Ag nanowires shown in Fig. 1a dispersed in their original solution. The wavelength of the

Characterisation of the Montana Instruments Cryostation C2 for low temperature Magneto-Optical Kerr Effect measurements using the NanoMOKE 3

Microscopic Structures

ScanArray Overview. Principle of Operation. Instrument Components

Supplementary Information

HybridStage - Automated, large sample-area mapping made easy

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

Unit-25 Scanning Tunneling Microscope (STM)

Keysight Technologies Why Magnification is Irrelevant in Modern Scanning Electron Microscopes. Application Note

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications

Science in the Classroom. Actin Network Architecture can determine Myosin Motor Activity Student Activity

Scanning Electron Microscopy

Notes: Light and Optics. Reflection. Refraction. Law of Reflection. Light goes straight 12/13/2012

EXPERIMENTAL STUDY OF ANNULAR TWO-PHASE FLOW ON ROD-BUNDLE GEOMETRY WITH SPACER

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

Fast Laser Raman Microscope RAMAN

Bias errors in PIV: the pixel locking effect revisited.

SUPPLEMENTARY INFORMATION

Effect of Ink Spread and Opitcal Dot Gain on the MTF of Ink Jet Image C. Koopipat, N. Tsumura, M. Fujino*, and Y. Miyake

RECENTLY, using near-field scanning optical

Fast Laser Raman Microscope RAMAN

NANO MODIFICATION OF THE W(100)/ZrO ELECTRON EMITTER TIP USING REACTIVE ION ETCHING

The Physics of Single Event Burnout (SEB)

Assay development (biochemical protein-protein interaction assays)

UNIT-II : SIGNAL DEGRADATION IN OPTICAL FIBERS

Supplementary Materials for

Scanning Ion Conductance Microscope ICnano

3D simulations of the experimental signal measured in near-field optical microscopy

Electrical Properties of Chicken Herpes Virus Based on Impedance Analysis using Atomic Force Microscopy

Tunneling transport of mono- and few-layers magnetic van der Waals MnPS3

Inductive Reasoning Practice Test. Solution Booklet. 1

Since a most basic characteristic of contracting muscle is

Microvasculature on a chip: study of the Endothelial Surface Layer and the flow structure of Red Blood Cells

Chemical Imaging. Whiskbroom Imaging. Staring Imaging. Pushbroom Imaging. Whiskbroom. Staring. Pushbroom

On spatial resolution

Hybrid Integration Technology of Silicon Optical Waveguide and Electronic Circuit

XYZ Stage. Surface Profile Image. Generator. Servo System. Driving Signal. Scanning Data. Contact Signal. Probe. Workpiece.

Fabrication of Probes for High Resolution Optical Microscopy

SUPPLEMENTARY INFORMATION

Mastery. Chapter Content. What is light? CHAPTER 11 LESSON 1 C A

Morphological Variation in a Toroid. Generated from a Single Polymer Chain

DeltaMyc. Fluorescence Lifetime Mapping Microscope. Affordable Fluorescence Lifetime Imaging Microscopy (FLIM)

Basic methods in imaging of micro and nano structures with atomic force microscopy (AFM)

Fundamental Characteristics of Grooving Aiming at Reduction of Kerf Loss Using an Ultrafine Wire Tool

SUPPLEMENTARY INFORMATION

Supplementary Materials for

Application Note #548 AcuityXR Technology Significantly Enhances Lateral Resolution of White-Light Optical Profilers

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Constant Frequency / Lock-In (AM-AFM) Constant Excitation (FM-AFM) Constant Amplitude (FM-AFM)

Abstract and Kinetic Tile Assembly Model

State of the Art Room Temperature Scanning Hall Probe Microscopy using High Performance micro-hall Probes

Supporting Information

Shreyash Tandon M.S. III Year

Transcription:

Supplementary information for Video imaging of walking myosin V by high-speed atomic force microscopy Noriyuki Kodera 1,2, Daisuke Yamamoto 1,2, Ryoki Ishikawa 3, Toshio Ando 1,2 * 1 Department of Physics, Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan. 2 CREST, JST, Sanban-cho, Chiyoda-ku, Tokyo 102-0075, Japan. 3 Department of Molecular and Cellular Pharmacology, Gunma University Graduate School of Medicine, 3-39-22 Showa-machi, Maebashi 371-8511, Japan. *Correspondence and request for materials should be addressed to T.A. (E-mail: tando@kenroku.kanazawa-u.ac.jp) This document contains: 1. One Supplementary Table with legend 2. Six Supplementary Figures with legends 3. Six legends for Supplementary Movies 1

Supplementary Table 1 Summary of kinetic parameters. Kinetic parameters were V = V / 1 K / ATP and obtained using the relationships max ( + m [ ]) V d s /( 1/ k [ ATP] + 1 k ) =, where V is the average translocation velocity in a given 1 / 2 [ATP] (Supplementary Fig. 2), V max is the maximum translocation velocity, K m is the apparent Michaelis-Menten constant, d s is the average step size, and k 1 and k 2 are the second-order ATP binding rate constant and first-order ADP dissociation rate constant, respectively. The second relationship holds because ADP release is a major rate-limiting step, ATP binding is also a rate-limiting step in low [ATP], other chemical steps occur much faster 1, and one discrete translocation is tightly coupled to one ATP hydrolysis 2. All values represent best-fit results ± s.d. When DPTAP-free lipid bilayers were used, V max was 403 ± 7 nm s -1, which is similar to that obtained using fluorescence microscopy under the same buffer condition 3,4, indicating that tip-sample and surface-sample interactions have negligible effects on motor activity. However, in the absence of surface-sample attraction, M5-HMM occasionally did not travel sideways along actin filaments; hence, it was difficult to acquire high-resolution images since AFM is inefficient for visualising molecules not supported on a surface. Therefore, the addition of the positively charged lipid was necessary to improve image quality and experimental efficiency, despite a modest decrease in average translocation velocity. 2

Supplementary Figure 1 Schematic of assay system for HS-AFM imaging (not scaled). A mica surface was fully covered with biotin-containing lipid bilayers. Streptavidin molecules (green circles) were partially deposited on the substrate. Biotinylated actin filaments were immobilised on the bilayer surface through streptavidin molecules. M5-HMM was deposited on the lipid bilayers. All imaging experiments were performed in the tapping mode using a laboratory-built high-speed AFM apparatus 5,6. 3

Supplementary Figure 2 Translocation velocity of M5-HMM observed by HS-AFM. The observations were performed in various [ATP] using planar lipid bilayer surfaces containing different fractions of positively charged lipid DPTAP. Walking M5-HMM molecules were imaged at 146.3 ms frame -1 (400 125 nm 2 scan range, 80 25 pixels). In ATP higher than 20 μm, very shortly dwelled states were missed. In this case, translocation velocity was obtained from movies in which at least four instances of dwelling at different locations along an actin filament were captured on video. The translocation velocity in a given [ATP] was thus measured and its average (V) was fitted V = d s / 1/ k ATP + 1 k (see Supplementary Table 1). The to the relationship ( [ ] ) 1 / curves are best-fit results. Each data point was obtained from the translocation trajectories of more than 100 molecules (103-276). Error bars, ± s.d. The fitting results are summarised in Supplementary Table 1. 2 4

Supplementary Figure 3 Time courses showing the molecular conformations under different nucleotide conditions. (a) Six typical time courses in 1 μm ATP. Each time course starts from the right-pointing triangle and ends with the left-pointing 5

triangle. Discrete ~36 nm steps occur at the vertical dashed lines. Each box corresponds to a video frame. The colour code of the boxes is given at the bottom of the figure. The same colour code is also used for (b) and (c). Each box with a black dot, which is contained in the asterisk-labelled time course, corresponds to an AFM image shown in Fig. 1a (Supplementary Movie 1a). Scale bar, 1 s. (b) Two typical time courses in 50 μm ADP. Each box with a black dot in the first time course corresponds to an AFM image in Fig. 2a (Supplementary Movie 3). Scale bar, 3 s. (c) Three typical time courses in the NF condition. Each box with a black dot in the first time course corresponds to an AFM image in Fig. 2c (Supplementary Movie 5a). The molecule observed in the second time course is shown in Supplementary Movie 5b. Scale bar, 3 s. 6

Supplementary Figure 4 Angle distributions of single-headed M5 bound to actin. The single-headed M5 is formed by natural unwinding of the short tail of two-head bound M5-HMM. (a) Schematic showing the angle measured. (b), (d) AFM images of single-headed bound M5 in the NF and 1 mm ADP conditions, respectively. The plus ends of actin filaments are indicated with +. The measured angles are shown in the images. Imaging rate, 333.2 ms frame -1. Scale bar, 30 nm. (c), (e) Histograms of the angle measured for single-headed bound M5 in the NF and 1 mm ADP conditions, respectively. Blue broken lines, single-gaussian fit results; black solid lines, double-gaussian fit results; red lines, Gaussian components in double-gaussian fit. All fits were restricted to bins with > 10 counts. All values for peak angles represent mean ± s.d. The two-gaussian distributions are statistically significant judging from the F-test results: p < 0.05 for the NF condition; p < 10-6 for the 1 mm ADP condition. 7

Supplementary Figure 5 Proportion of foot stomp events that occur at L- and T-heads in various [ADP]. The proportion depends on the L-head conformation (straight or sharp bend); the proportion difference between the L- and T-heads becomes smaller when the L-head assumes the sharp bend conformation, irrespective of [ADP]. In 50 μm ADP, the L-head almost always assumes the straight conformation. Foot stomp events counted without distinguishing between the two conformations of the L-head are indicated by all. The numbers in <events>, [molecules], and (frames) represent the respective numbers examined for foot stomp events observed under the respective conditions. 8

Supplementary Figure 6 Walking mechanism of myosin V highlighting the energy landscapes of actin-bound L- and T-heads. The red lines represent the energy landscapes of actin-bound heads in the respective states. The blue lines represent the energy landscapes of detached heads. The left and right sides partitioned by the vertical dashed lines of each energy landscape shown in red correspond to the reverse arrowhead (R-ARH) and arrowhead (ARH) conformations, respectively. The left and 9

right sides partitioned by the vertical lines of each energy landscape shown in blue correspond to the pre-stroke and post-stroke conformations, respectively. The black dot in each energy landscape indicates the most probable position of the corresponding head in the energy landscape. Each energy landscape shown in a faint colour represents that in the previous state. (a) Initial state of the step cycle in which both heads (H1 and H2) carry bound ADP. In this chemical state, foot stomping more frequently occurs at the L-head than at the T-head, and therefore, the free energy level of the L-head is higher than that of the T-head. The L-head-bound ADP is very stable. (a ) State in which the L-head detaches from actin while foot stomping. The detached L-head is in equilibrium between the pre-stroke and post-stroke conformations. The T-head is in the lowest-energy state as the intramolecular strain is released. Even in this state, the T-head can swing backward with a low probability. Transitions between (a) and (a ) occur alternately. (b) ADP release, subsequent ATP binding, and resulting detachment at the T-head. The T-head detachment removes the high potential barrier in the energy landscape of the L-head, thus, the L-head spontaneously descends to the bottom of the energy landscape, swinging from the R-ARH orientation to the ARH orientation. The T-head rotationally diffuses around the advancing neck-neck junction to search for an actin subunit to attach to. The ADP-Pi-bound L-head possibly preferentially assumes the pre-stroke conformation as reported previously 7,8. (c) The detached head is reattached and then phosphate is immediately released to return to the original two-head bound state (a), resulting in a ~36 nm advance. As the sharp bend conformation is rarely observed on the leading neck even in low [ATP] (0.1 μm and 1 μm), M5 only moves forward by repeating the changes described in (a), (b), and (c) in this order. (d) The sharp bend conformation is frequently observed in the leading neck in the NF condition. In this structural state, the two heads are bound to actin in the ARH orientation (at least around the motor domains) with similar affinities, and thus, the foot stomp occurs on the two heads at nearly equal frequencies. 10

Legends for Supplementary Movies Supplementary Movie 1 High-speed AFM movies showing unidirectional processive movement of M5-HMM. The dynamic process in 1 μm ATP was filmed at 146.7 ms frame -1 (6.8 frames s -1 ) and the movie is played at 7 frames s -1. To track the M5-HMM molecules, the scan area was moved (a, c, d). Foot stomp events are marked with light-blue (L-head) and red triangles (T-head). (a) Scan range, 130 65 nm 2 with 80 40 pixels. Twelve frames are selected and shown in Fig. 1a. The time course of the molecular conformations is shown in the asterisk-labelled sequential boxes (Supplementary Fig. 3a). (b) Scan area, 125 62.5 nm 2 with 80 40 pixels. (c), (d) Typical movies showing long processive runs. (c) Scan range, 130 65 nm 2 with 80 40 pixels; the whole imaging area, 560 160 nm 2 ; number of steps observed, 15. (d) Scan range, 150 75 nm 2 with 80 40 pixels; whole imaging area, 500 120 nm 2 ; number of steps observed, 14. Supplementary Movie 2 High-speed AFM movies showing hand-over-hand movement of M5-HMM. The dynamic process was filmed at 146.7 ms frame -1 (6.8 frames s -1 ) and the obtained movies are played at 7 frames s -1. Additional streptavidin molecules were scattered on the biotin-containing surface to slow the step movement. Foot stomp events observed at the L-head are marked with light-blue triangles (a, e). No foot stomping at the T-head is observed in these five movie clips. (a), (b) In 1 μm ATP. Scan area, 150 75 nm 2 with 80 40 pixels. (c) In 2 μm ATP. Scan area, 130 65 nm 2 with 80 40 pixels. Frames selected from (a) and (c) are shown in Figs. 1d and 1e, respectively. (d), (e) In 1 μm ATP. Scan area, 110 75 nm 2 with 80 50 pixels. Supplementary Movie 3 High-speed AFM movie of two-head bound M5-HMM observed in 50 μm ADP. The sample was filmed at 333.2 ms frame -1 (3 frames s -1 ) and the movie clip is played at 3 frames s -1, from which 12 frames are selected and shown in Fig. 2a. The conformational states observed in the movie clip are shown in the first time course of Supplementary Fig. 3b (between the square brackets). Scan area, 90 90 nm 2 with 80 80 pixels. Foot stomp events observed at the L-head are marked with light-blue triangles. No foot stomping at the T-head is observed in this movie clip. Supplementary Movie 4 High-speed AFM movies showing unwinding of short coiled-coil tail of M5-HMM. (a), (b) Two different samples in 50 μm ADP were filmed 11

at 333.2 ms frame -1 (3 frames s -1 ) and the obtained movies are played at 3 frames s -1. AFM images selected from (b) are shown in Fig. 2b. Rewinding was not observed. Scan area, 90 90 nm 2 with 80 80 pixels. (c), (d) Two different samples in ADP were filmed at 333.2 ms frame -1 (3 frames s -1 ) and the obtained movies are played at 3 frames s -1. Unwinding and rewinding of the tail were observed. Scan area, 90 90 nm 2 with 80 80 pixels. (c) In 50μM ADP, (d) in 1 mm ADP. Supplementary Movie 5 High-speed AFM movies of two-head bound M5-HMM observed in the NF condition. Three different samples were filmed at 333.2 ms frame -1 (3 frames s -1 ) and the obtained movies are played at 3 frames s -1. Foot stomp events at the L- and T-heads are marked with light-blue and red triangles, respectively. (a) Scan area, 90 90 nm 2 with 80 80 pixels. This movie corresponds to the AFM images shown in Fig. 2c and to the first time course shown in Supplementary Fig. 3c. (b) Scan area, 80 80 nm 2 with 100 100 pixels. This movie corresponds to the second time course shown in Supplementary Fig. 3c. (c) Scan area, 100 100 nm 2 with 80 80 pixels. Supplementary Movie 6 High-speed AFM movie showing transition between the straight and sharp bend conformations of the L-head. Actin-bound M5-HMM was imaged in the presence of 0.1 μm ADP at 3 frames s -1 and the obtained movie is played at 12 frames s -1. Scan area, 90 90 nm 2 with 80 80 pixels. The images are affected by the double-tip effect. 12

Supplementary References 1. De La Cruz, E. M. et al. The kinetic mechanism of myosin V. Proc. Natl. Acad. Sci. USA 96, 13726-13731 (1999). 2. Sakamoto, T. et al. Direct observation of the mechanochemical coupling in myosin Va during processive movement. Nature 455, 128-132 (2008). 3. Forkey, J. N. et al. Three-dimensional structural dynamics of myosin V by single-molecule fluorescence polarization. Nature 422, 399-404 (2003). 4. Baker, J. E. et al. Myosin V processivity: multiple kinetic pathways for head-to-head coordination. Proc. Nat.l Acad. Sci. USA 101, 5542-5546 (2004). 5. Ando, T. et al. A high-speed atomic force microscope for studying biological macromolecules. Proc. Natl Acad. Sci. USA 98, 12468-12472 (2001). 6. Ando, T., Uchihashi, T. & Fukuma, T. High-speed atomic force microscopy for nano-visualization of dynamic biomolecular processes. Prog. Surf. Sci. 83, 337-437 (2008). 7. Burgess, S. et al. The prepower stroke conformation of myosin V. J. Cell Biol. 159, 983-991 (2002). 8. Volkmann, N. et al. The structural basis of myosin V processive movement as revealed by electron cryomicroscopy. Mol. Cell 19, 595-605 (2005). 13