Manual FOR YOUR SAFETY. Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.

Never fill any required clearance space with insulation or any other building materials surrounding the chimney.

HEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING

TYPE "B" GAS VENT. Do not connect gas vent to a solid or liquid fuelled appliance or any appliance requiring a chimney.

ECOVENT USA CHIMNEY MODEL EV-SHT 5"-8" DIAMETER INSTALLATION INSTRUCTIONS

SOUTHWEST KIVA 24 FIREPLACE Prefabricated Masonry Wood Burning Firebox and Metal Frame

DURATECH CHIMNEY 5"-8" DIAMETER INSTALLATION INSTRUCTIONS

Zero Clearance Fireplace 36 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.

Zero Clearance Fireplace 44 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450)

Our non-positional lock system on the Selkirk. The Locktab is located on the female end of the gas vent.

Installation Instructions. All-Fuel Chimney System 5 to 8 diameter. DuraTech

Kiva Fireplace WOOD BURNING INSTALLATION MANUAL

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS

DURA-PLUS (SDP) INSTALLATION AND OPERATION INSTRUCTIONS MH7399

contemporary gas fireplaces

C Series. Cool Surface System INSTRUCTION MANUAL FRONT VENT [ ] PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

INSUL-FLUE is used to reduce the danger of radiant heat from smoke pipe, flue pipe, gas vents, etc. igniting combustibles.

650 C TEMP/GUARD CHIMNEY SIZES ºC TEMP/GUARD CHIMNEY

VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS

The following manual is for the 80ZC cabinet ONLY. If you require information on the Model 80 unit that fits inside this cabinet, please download the

Installation & Maintenance Instructions

Installation Instructions. All-Fuel Chimney System 5 to 8 diameter. DuraTech

GAS FIREPLACES TRADITIONAL. TRADITIONAL GAS FIREPLACES

GAS FIREPLACES TRADITIONAL. TRADITIONAL GAS FIREPLACES

GAS FIREPLACES TRADITIONAL. TRADITIONAL GAS FIREPLACES

Earthcore Air-Cooled ECO-Steel Chimney is not designed for use on products that operate at continuous temperatures in excess of 1000 F.

ULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS

Installation Instructions. All-Fuel Chimney System 10 to 24 diameter. DuraTech

Kiva Fireplace GAS BURNING INSTALLATION MANUAL WITH DOUBLE WALL AIR COOLED CHIMNEY

SECURE-TEMP ASHT + CANADA OUR PRODUCTS LIVE UP TO OUR NAME, WARNING... 2 GENERAL INFORMATION, USA & CANADIAN APPLICATIONS.. 11

60/100 Concentric Flue System Parts

PLEASE READ AND UNDERSTAND THE REQUIREMENTS BEFORE PROCEEDING

FACTORY BUILT INSULATED CHIMNEY

Crave Series. Direct Vent Gas Fireplaces

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

ProBuilder Linear CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

EXCEL FACTORY BUILT CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS

kééç=eéäé\ =KKK`çåí~Åí=ìë=~íW çêiîáëáí=ìë=çåäáåé=

MM700R Recess Box Kit Addendum

HowtoPlans..org. 12'x20' Garden Shed Plan

Type B Gas Vent GV-25 CATALOG FEATURES. Round and oval gas vent pipe and fittings for residential, commercial and industrial applications.

DuraPlus. Installation Instructions. All-Fuel Chimney System. C o m p l e t e V e n t i n g S o l u t i o n s

Installation Instructions. All-Fuel Chimney System. DuraPlus

Dura-Lock Roof System

TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual. Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B

ULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY

ZERO CLEARANCE MANUAL

FLEXIBLE CHIMNEY LINER PRODUCT CATALOGUE

HowtoPlans..org. DuraMax 8'x12 Garden Shed Plan

INSTALLATION INSTRUCTIONS for PYROCLASSIC FIRES LTD. 100mm SLOPING CEILING FLUE KIT

Accentra 52i Pellet Insert Zero Clearance Cabinet Part #

WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL

GLOSSARY OF TERMS SECTION 8

HRI4E REGENCY HORIZON MEDIUM GAS INSERT STANDARD FEATURES. HRI4E shown with Regular Backing Plate, Vignette Faceplate in Platinum and Black Crystals.

GAS FIREPLACES INSERTS. GAS FIREPLACES INSERTS

10. Vents, Baffle Guard and Blocking

CHASKA 34, CHASKA 335S, CHASKA 29, CHASKA 25

SLP-LPC. Installation & Operating Instructions. SLP-LPC Preparation

GAS FIREPLACES INSERTS. GAS FIREPLACES INSERTS

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

INSTALLATION INSTRUCTIONS

ProBuilder Series CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

CATALOG. Stainless Steel Flexible Chimney Liner

Chaska 34, Chaska 335s, Chaska 29, Chaska 25

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual

Fireside Retreat. Craftsman-Style BEFORE

INSERTS GAS FIREPLACE. GAS FIREPLACE INSERTS

Definitions and Design Considerations... W-CR-2

Installation Guide Classic Series Wood Siding

HowtoPlans..org. Skyline 10'x14' Garden Shed Plan

SECURE-TEMP ASHT+ INSTALLATION AND OPERATING INSTRUCTIONS SUMMARY. Read these instructions and keep them for future reference

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

LE7000 Provincial Built-in (Zero Clearance) Kit Instructions.

gas fireplace inserts

CHASKA 34, CHASKA 335S, CHASKA 29, CHASKA 25

Versatrac R-System Stock Extrusions, Clips and Accessories

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

Versatrac R-System Stock Extrusions, Clips and Accessories

ROOFING City of Grand Rapids Building Safety Division

FASTENERS BUILDING DEPARTMENT

GlasRoc Sheathing Type X

Installation Guide for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows

CFDTT-01. Control Joint Study (General)

INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE

10x10 Shed Plans and Building Guide

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

LRI6E LIBERTY RADIANT LARGE GAS INSERT RADIANT CONVECTIVE HEAT

Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes

The quick and simple way to create chimney breasts and install inset stoves

HowtoPlans..org. 14'x8' Garden Shed Plan

9/16" (14mm) 1/2" (12mm)

Transcription:

HZ30E - 10 Gas Fireplace Model HZ30E-NG10 HZ30E-LP10 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High 5 W.C. (1.5 kpa) 3.5 W.C. (0.87 kpa) 11 W.C. (.74 kpa) 10 W.C. (.49 kpa) Orifice Size #50 DMS #57 DMS Maximum Input Altitude 0-4500 ft. (0-137m) Vent Sizing 14,000 BTU/h (3.81 kw) 4 Inner 6 7/8 Outer 13,000 BTU/h (3.81 kw) 4 Inner 6 7/8 Outer Approved Venting Systems Flex Vent Systems: Rigid Pipe Vent Systems: Unit Dimensions: FPI AstroCap Flex Vent Simpson Direct Vent Pro American Metal Products Amerivent Direct Security Secure Vent Selkirk Direct-Temp Metal-Fab Sure Seal Faceplate Dimensions: Non-Combustible Requirements: Metal Stud 3-11/16" (830mm) Metal Stud (header) on edge Metal Stud 13-1/4" (367mm) Non-combustible Material 14-9/16 (370mm) Non-combustible Material 14-9/16 8-7/8 Non-combustible Material Non-combustible Material 34-3/16" (868mm) 6-3/8 (16mm) " (51mm) " 6-3/8 (51mm) (16mm) 1

Framing Dimensions: Framing Dimensions Description HZ30E-10 A Framing Height 33-5/16 (946mm) B Framing Width 31-3/16" (79mm) C* Framing Depth* C1 Horizontal Vent 15-3/4 (400mm) Flex C1 Horizontal Vent 19 (48mm)Rigid C Vertical Vent, vertical rise terminating horizontally- (559mm D Minimum Height to Combustibles Rigid 35-1/" (90mm) Flex 3-7/8" (835mm) E Corner Wall Depth 43-5/16" ( 1100mm) F Corner Facing Wall Width 61-1/4" (1556mm) G Vent Centerline Height Rigid 9-1/4" (743mm) Flex 6-5/8" (676mm) H Non-combustible facing height 13-1/4 (367mm) I Gas Connection Opening Height " (51mm) J Gas Connection Height 3-1/4" (83mm) K Gas Connection Inset 4-1/8" (105mm) L Gas Connection Opening Width 3-1/" (89mm) * Framing depth measurement is noted with the nailing strips set as far forward on the firebox as possible. The nailing strips can be adjusted back up to 3-1/8 to allow for varying thicknesses in non-combustible material & wall finishes. Clearance Requirements: Clearance: Dimension Measured From: A: Sidewall (on one side) 8" (03mm) Side of Fireplace Opening B G D E A Installed Close to Floor F B: Ceiling (room and/or alcove) 39" (991mm) Top of Fireplace Opening C: Mantel Height (min.) 13-1/4" (330mm) Top of Fireplace Opening D: Mantel Depth (max.) 1" (305mm) 1-1/4" Above Fireplace Opening E: Alcove Width 60" (154mm) Sidewall to Sidewall (Minimum) F: Alcove Depth 36" (914mm) Front to Back Wall (Maximum) G: From Floor 1" (533mm) Top of Fireplace Opening Note: 0" No hearth required Minimum Vent Clearances to Combustibles Horizontal Top Horizontal Side Horizontal Bottom Vertical Vent Passing through wall/ floor/ceiling - when firestop is used 3" (76mm) " (51mm) " (51mm) " (51mm) 1-1/ A Unit F Alcove

FRAMING & FINISHING 1) Frame in the enclosure for the unit with framing material. IMPORTANT: The framed opening must be of non-combustible material. Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed.. For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fireplace itself.) WARNING: Failure to insulate and add vapor barriers to the inside of the exterior wall will result in operational and performance problems including, but not limited to: excessive condensation on glass doors, poor flame package, carbon, blue flames etc. These are not product related issues. 6. If material such as brick, stone, etc extends past the faceplate depth (3-1/8 ), when finishing around the faceplate, the minimum opening dimensions noted below must be adhered to ensuring for the removal of the faceplate and for the safe operation of this appliance. 0 34-1/ 3. The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See Clearances section. Combustible materials can be laid against the side and back standoffs and the stove base. 5. If material such as brick, stone, etc extends past the faceplate depth (3-1/8 ), when finishing around the faceplate, the minimum opening dimensions noted below must be adhered to ensuring for the removal of the faceplate and for the safe operation of this appliance. 33-11/16 19-11/16 7. For material such as brick, stone, etc that extends less than 3-1/8, the minimum opening dimensions noted below must be adhered, when finishing around the faceplate. This is to ensure the removal of the faceplate and for the safe operation of this appliance. 9-1/8 14-13/16 8. If finishing the unit with the inner faceplate only - the finishing material may be brought up to the edge of the unit. 8-7/8 Important: 1/ gap required between faceplate and finished wall when using part 4 pc. faceplate. When using the outer faceplate the 1/ gap is not necessary. 14-9/16 3

Combustible Mantels: Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. Note: Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour. Mantel Leg Clearances: MANTEL LEG (51mm) Non-Combustible 7" 4" 1-1/" (38mm) Allowable mantel leg projection 5-1/ (140mm) 8 (03mm) 11 (79mm) Horizontal Terminations: VENTING ARRANGEMENT FOR HORIZONTAL TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 o (two 45 o elbows equal one 90 o elbow). (Not including the starting 45 o elbow at the flue collar when using rigid venting.) Note: Must use optional rigid pipe adapter (Part# 510-994. when using Rigid Pipe Venting Systems. VENT RESTRICTOR SETTING: Vent restrictor factory set at Set 0. Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 if required. Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent length of up to 10 feet. If longer runs are required, rigid pipe must be used. Maintain clearances to combustibles as listed in "Clearances" section Horizontal vent must be supported every 3 feet. Firestops are required at each floor level and whenever passing through a wall. A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. Flex system can only be used up to 10 feet - otherwise rigid venting must be used. Vertical Height (Feet) from Centreline 18 16 14 1 10 8 6 4 Horizontal (Feet) 0 4 6 8 10 1 14 16 18 0 Vent Restrictor on Set Vent Restrictor on Set 1 Vent Restrictor on Set 0 (Factory Set) 9-1/4 (743mm) Minimum Height Requirement 0 4

Horizontal Flex Terminations: FPI Kit # Length Contains: #946-513 Feet 1. 6-7/8 flexible outer liner (Kit length). 4 flexible inner liner (Kit length) 3. spring spacers #946-515 4 Feet 4. thimble 5. AstroCap termination cap 6. screws 7. tube of Mill Pac #946-516 10 Feet 8. plated screws 9. S.S. screws #8 x 1-1/ drill point 4" dia. flue pipe 6-7/8" (173mm) dia. Flue pipe Wall Thimble spring spacer AstroCap TM Termination Cap (Part# 946-53/P) Venting arrangements HORIZONTAL TERMINATIONS RIGID PIPE 4 X 6-7/8 The minimum components required for a basic horizontal termination are: 1 Horizontal Termination Cap 1 45 o Elbow 1 Rigid Pipe Adaptor (510-994. 1 Wall Thimble 1 Length of pipe to suit wall thickness (see chart) Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips. 510-994 If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add inches. Wall Thickness (inches) Flat Wall Installation Vent Length Required (inches) 4" - 5-1/" 6" 7" - 8-1/" 9" 10" - 11-1/" 1" 9" - 14-1/' 11" - 14-5/8" Adj. Pipe 15" - 3-1/" 17" - 4" Adj. Pipe 5

0 HZ30E Gas Fireplace VENTING ARRANGEMENT FOR VERTICAL TERMINATIONS Vertical Venting with One(1. 90 o Elbows (1-90 o = - 45 o ) Horizontal (Feet) 6 8 4 10 1 14 The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90 o elbows, with Rigid Pipe Venting Systems. 40 38 36 Two 45 o elbows equal to one 90 o elbow. Maximum of four 45 o elbows allowed, not including the starting 45 o elbow at the flue collar. 34 3 Vent must be supported at offsets. 30 Minimum distance between elbows is 1 ft. (305mm). 8 Maintain clearances to combustibles as listed in the "Clearances" section. 6 4 Horizontal vent must be supported every 3 feet. Firestops are required at each floor level and whenever passing through a wall. Must use optional rigid pipe adaptor (Part# 510-994. when using rigid pipe vent systems. Vertical Height (Feet) 0 18 16 14 Vent Restrictor on Set Maximum: 8 ft. (8.m) Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 or Set if required. 1 10 8 Vent Restrictor on Set 1 6 4 Minimum 8 (.6m) 0 Min. 9-1/4 (743mm) VERTICAL TERMINATIONS RIGID PIPE 4" X 6-5/8" The minimum components required for a basic vertical termination are: 1 Vertical Termination Cap 1 45 o Elbow 1 Rigid Pipe Adaptor 510-994 1 Ceiling Firestop 1 Flashing 1 Storm Collar 1 Length of pipe to suit wall thickness (see chart) Galvanized pipe is desirable above the roofline due to its higher corrosion resistance. Continue to add pipe sections through the flashing until the height of the vent cap meets the minimum height requirements specified in Dia. 4 or local codes. Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem. 6