microos Occupant Sensors One Way microostm Occupant Sensor Two Way microostm Occupant Sensor Sensors

Similar documents
Dual Technology Wall Mount Occupancy Sensor

Dual Technology Wall Mount Occupancy Sensor

Infrared Wall Mount Occupancy Sensor

Dual Technology Ceiling Mount Sensor

Remove wallplate and switch mounting screws. Carefully remove switch from wall leaving all wires attached.

ETC Installation Guide

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

Wireless Ceiling Mount Sensor

Application Note #463 Revision A July 2012

Occupancy Sensors for High-Bay Applications

LOS-C series ceiling-mount occupancy sensor

with Light Level, Isolated Relay and Manual On features

LRF20CR2BPWH Ceiling MNT Wireless Occ Sensor

Radio Powr SavrT Occupancy / Vacancy Sensor

Application Note #626 Revision A December 2016 Captive Card Key Integration for myroom Prime

CX-100. Installation Instructions. PIR Occupancy Sensor SPECIFICATIONS

Application Note #622 Revision C April Finiré 3 Design Guide. Overview

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Wireless occupancy/vacancy sensor

Radio Powr SavrTM Wireless Occupancy / Vacancy Ceiling Sensor


ETC Installation Guide


Vive Integral Fixture Controls

Wireless Ceiling Motion Sensor for Occupancy / Vacancy Detection with integrated diagnostic tools INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

Tall Wide Extra Deep Bookcase

#916 CLASSIC 16 GUN CABINET ASSEMBLY INSTRUCTIONS

v3 360 Passive Infrared Line Voltage Occupancy Sensor

CDAS CDAS39 SHELF UNIT

Installation Instructions

Advanced Programming Mode (APM) for Maestro ELV Dimmers

Eco-$mart, Inc. TOLL FREE:(888) FAX:(941)

DLA-E (Philips EvoKit) The DLA-E is designed to install in the mounting slot of the Philips EvoKit SR retrofit kit.

Maestro Occupancy Sensor C L Dimmer Additional Programming, Installation, and Troubleshooting Help

Wireless Ceiling Mount Sensor for Occupancy / Vacancy Detection INSTALLATION GUIDE

ASSEMBLY AND INSTALLATION INSTRUCTIONS

PowPak Relay Module. PowPak Relay Module Energi TriPak Series Wireless Lighting Control

Constable Oak Extension Dining Table

PowPak Dimming Module with EcoSystem

Occupancy/Vacancy Sensor Design and Application Guide

SELECTABLE MODE HIGH/LOW/OFF PIR FIXTURE INTEGRATED INDOOR/OUTDOOR MOTION/PHOTO SENSOR

Installing flat panels on the MPL15 wall mount

#27541 Mobile Laptop. Charging Station. Assembly Instructions

CAUTION: To prevent damage to your equipment, thoroughly study all instructions and illustrations before you begin to install the extension.

CES SENSORS INSTALLATION AND MAINTENANCE MANUAL (IMM)

Puerto Rico - 2 Door Shoes Cupboard

BLUEMOTION UXP, CDP, SD

PowPak Relay Module with Softswitch

O ccupancy and Light Level Sensor L ow Vo l tage Ceiling Fixture Mount

Installing the FSP-211 Sensor in Light Fixture

Instruction page index: Installation Instructions for Kilo S Models KILOS-CF & KILOS-SF. Page 1 of 5. Center Feed installation Side Feed installation

TURN OFF POWER ARRETEZ LE COURANT DESCONECT LA CORRIENTE. Tap Button (tap on/off) Raise Alt. Button Lower. Alt. PIR Hi Med Low Min.

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

13MM FLAT WRENCH FOR LEVELING THE GLIDES OF STRUCTURE 6MM ALLEN KEY FOR ROOF CLIPS PHILLIPS HEAD BIT FOR SCREWS FOR DOOR FRAME

BOOKCASE WARNING. Illustration 1

6MM ALLEN KEY FOR ROOF CLIPS PHILLIPS HEAD BIT FOR SCREWS FOR DOOR FRAME SPIRIT/LASER LEVEL TO LEVEL THE UNIT

IMPORTANT WARNINGS AND CAUTIONS!

HQ Hideaway. Installation and Operation Version 2.2, April 2015 Part # QT40100

Codonics SLS 500i Shelf Installation

FENCING ASSEMBLY INSTRUCTIONS

Storage Cabinets 9000 Series Assembly Instructions

Connecting the Channel A

INSTALLATION INSTRUCTIONS INS T A L L A TIO N INS T R U C TIO N S THE MAVERICK HANGER R H

EBDHS-MB-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

PowPak CCO Module. PowPak CCO Module Energi TriPak Series Wireless Lighting Control

NUMBER OF HORIZONTALS REQUIRED FOR 2 ON CENTER SPACING.

Wireless Occupancy Sensor User Guide

Speaker Mount Center Channel Speaker Adapter (PAC-301)

MCH42 / MCH48 MODULAR SERIES 2400/3000 CORNER HUTCH

Installation Instructions for Zip Suspension Downlight with Remote Power and 4" Square or Round Canopy

Vive PowPak CCO Module

#27541 Mobile Laptop Charging Station

Custom Pendant- Hardwire Assembly and Installation Instructions

GE Lighting. control. Aware Occupancy and Photo Sensors

Stuff-Your-Stuff Platform Bed (Twin and Full)

FC-SENSOR, FC-VSENSOR, FCJ-010, FCJ-ECO

LCD/Plasma Mount Manual

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

The Electric Kangaroo Pro

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

INTERIOR DUCTWORK KIT

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

Charlotte Dressing Table & Stool Set L4294

LOCK ASSEMBLY INSTRUCTIONS

2 Pendant Adjustment. Pendant Slider Plate. 3/4 (19mm) IP, (29mm) O.D. Knockouts. 1/2 (13mm) IP, (22mm) O.D. Knockout

Before Installation, Re-installation, or Troubleshooting:

ViveT PowPak Fixture Controls

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING

WAREHOUSE HANGER INSTALLATION INSTRUCTIONS R H INS T A L L A TIO N INS T R U C TIO N S

Operation Manual Panel Mounting Gas Pressure Regulators

Aluminium Structural Framing

INSTALLATION INSTRUCTIONS INS T A L L A TIO N INS T R U C TIO N S ROD IRON SCROLL HANGER R H

INSTALLATION INSTRUCTIONS FOR ALPACO CLASSIC PARTITIONS

FW / FIG Partition Kit(s) Installation Instructions

Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.

RESIDENTIAL MOTORIZED STORAGE UNIT

Transcription:

microos Occupant Occupant Sensor microos-1 12.9.03 Lutron s One Way and Two Way microos Occupant enable Lutron systems to change light levels when a space is occupied and/or unoccupied. Occupant sensors detect motion ultrasonically, without the coverage gaps associated with infrared sensors, and turns lights on or brightens them from the unoccupied light level. The occupant sensors are also compatible with Lutron s Power Pack for individual use with a line voltage power supply. Sensitivity and time delay are user adjustable. microos Occupant Sensor One Way microostm Occupant Sensor Maximum coverage area 900 sq. ft. (see included diagrams for coverage details) Key Design Features Automatically turns off lights when space is unoccupied. Detects motion ultrasonically in one direction. Sensitivity and time delay are user adjustable. Mounting Location Ceiling (Near Wall) Wire pigtails are Teflon-insulated. Model Number MOS-CM-15-WH Two Way microostm Occupant Sensor Maximum coverage area 2160 sq. ft. (see included diagrams for coverage details) Key Design Features Automatically turns off lights when space is unoccupied. Detects motion ultrasonically in one direction. Sensitivity and time delay are user adjustable. Mounting Location Ceiling (Center of space) Wire pigtails are Teflon-insulated. Model Number MOS-CM2W-15-WH

Specifications microos-2 12.9.03 Power Input: 15 VDC Environment 32 F to 104 F (0 C to 40 C). elative humidity: Less than 90% noncondensing. Indoor use only. Dimensions One Way and Two Way dimensions shown below. 6.12 inches (156 mm) 2.31 inches (59 mm) 1.62 inches (41 mm) Wiring 15 VDC must be externally supplied. Common and signal wire to a Lutron contact closure input device. +15 V DC Common Signal To additional occupancy sensors

Mounting Occupant microos-3 12.9.03 The occupant sensor must have an unobstructed view of the room. Do not mount behind or near tall cabinets, shelves, indirect hanging light fixtures. etc. Keep the occupant sensor away from air flow from ventilation outlets, windows, fans, etc. If installing a one-way occupant sensor, place the sensor on the same wall as the doorway so that traffic in a hallway will not affect the sensor. Closely follow the diagrams below concerning partition height, if applicable. Partitions higher than 48 inches reduce the coverage area of the sensor. Partitionable spaces with partitions higher than 71 inches should be treated as individual rooms. Closely follow the diagrams below concerning minor and major motion coverage. The sensor can detect major motion (such as a person taking a half step) at a greater distance that it can detect minor motion (such as writing or typing at a desk). Decrease total coverage area by 15% for soft rooms (examples, heavy draperies or heavy carpeting) Doorway microos Occupant Sensor Mounting Location for One-Way Mounting Location for Two-Way NON-PATITIONED AEAS No partitions or partitions not to exceed 48" in height SENSO NON-PATITIONED AEAS No partitions or partitions not to exceed 48" in heights 28' 30' 24' 36' 24' 30' Minor Motion Coverage Area Major Motion Coverage Area 56' 60' PATITIONED AEAS Partition heights of 49" to 71" SENSO PATITIONED AEAS Partition heights of 49" to 71" 19' 20' 17' 25' 17' 38' 41' 20'

Installation microos-4 12.9.03 Install the Mounting Post Insert the microos Occupant Sensor wires through the threaded mounting post provided. Slide the post down the wires and into the housing. Turn the post 1/4 turn clockwise to lock it into place. Install to the Ceiling Tile Drill a 3/4 inch hole into the ceiling tile where the Occupant Sensor is to be mounted (refer to the previous page for location concerns). Insert the wires and the mounting post through the hole in the ceiling tile. Slide the wires through the washer and nut provided. Slide the washer and nut down the wires toward the microos Occupant Sensor. otate Toward the Occupants Turn the microos Occupant Sensor so that the side slots are facing the occupied area in the room. Tighten the nut to secure the microos Occupant Sensor into place. Note: Finger tighten only to avoid stripping the mounting post. Be certain that the slots face the occupied area..

Sensor Adjustments microos-5 12.9.03 Locating the Occupant Sensor Adjustments The time delay and range/sensitivity adjustments are located on the end of the microos Ceiling Mount occupant sensor. Setting the ange/sensitivity and Time Delay The microos Occupant Sensor has been preset at the midrange of its sensitivity. If the setting is too sensitive, then the lights may not turn OFF automatically. If the setting is not sensitive enough, then the lights may turn OFF prematurely. Motion Indicator (red LED) ANGE Sensitivity (range) Time Delay (minutes) Once construction is finished, the furniture is in place, and the HVAC is ON, set the sensitivity as follows. Least Sensitive Most Sensitive 1.With minimal force, turn the ange Adjustment fully counterclockwise to its least sensitive position 9 12 3 2.Test the area of coverage by watching the red LED motion indicator. Verify that the LED lights when you move at different locations around the room. Moving your hand 12 inches in one second should make the LED light. Note: If the LED does NOT light, turn the ange Adjustment clockwise one hour and recheck. 3.If the LED does not turn off when you are still, the sensor may be detecting motion outside the room or due to moving air from an HVAC vent. Turn the range adjustment counter-clockwise one hour and check the LED again. 4.Adjust the Minutes Adjustment, or delay to off time, as desired for the space. 7:00 6 Set the ange/sensitivity Adjustment so that the sensor is least sensitive. 9 12 8:00 6 Turn the ange/sensitivity Adjustment clockwise one hour. Notes: The Time Delay (minutes) adjustment has been factory preset to its maximum setting of approximately 30 minutes. For non-lutron occupant sensors, please follow the manufacturers instructions for proper calibration. 3

microos-6 12.9.03 World Headquarters Lutron Electronics Co. Inc. 7200 Suter oad Coopersburg, PA 18036-1299 U.S.A. TOLL FEE: (800) 523-9466 (U.S.A., Canada, Caribbean) Tel: (610) 282-3800; International 1 610 282-3800 Fax: (610) 282-3090; International 1 610 282-3090 European Headquarters Lutron EA Ltd. Lutron House 6 Sovereign Close Wapping London, E1W 3JF, United Kingdom FEEPHONE: 0800-282107 (U.K.) Tel: (207) 702-0657; International 44 207 702-0657 Fax: (207) 480-6899; International 44 207 480-6899 Asian Headquarters Lutron Asuka Co., Ltd. No. 16 Kowa Bldg. 4F 1-9-20, Akasaka Minato-ku Tokyo 107-0052 Japan TOLL FEE: (0120) 083417 (Japan) Tel: (03) 5575-8411; International 81-3-5575-8411 Fax: (03) 5575-8420; International 81-3-5575-8420 Lutron Electronics, Co., Inc., reserves the right to make improvements or changes in its products without prior notice. Although every attempt is made to ensure that this information is accurate and up to date, please check with Lutron to confirm product availability, latest specifications and suitability for your application.