THOMAS SAMUEL THOMAS SAMUEL IP67 IS 15885(Part 2/Sec13) R41027766 ~
SPECIFICATION MODEL OUTPUT INPUT PROTECTION DC VOLTAGE RATED CURRENT RATED POWER SETUP, RISE TIME Note.2 HOLD UP TIME (Typ.) VOLTAGE RANGE Note.3 FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT WORKING TEMP. WORKING HUMIDITY 20 ~ 95% RH noncondensing ENVIRONMENT STORAGE TEMP., HUMIDITY 40 ~ 80, 10 ~ 95% RH SAFETY & EMC OTHERS NOTE DIMMING RANGE PWM FREQUENCY (Typ.) TOTAL HARMONIC DISTORTION MAX. NO. of PSUs on 16A CIRCUIT BREAKER OVERLOAD SHORT CIRCUIT OVER VOLTAGE OVER TEMPERATURE MAX. CASE TEMP. TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS Note.5 WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION Note.6 EMC IMMUNITY MTBF DIMENSION PACKING 12V 24V 36V 48V 0 ~ 100% 1.47kHz 16ms/115VAC or 230VAC 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section) 47 ~ 63Hz PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC @ full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) <0.25mA / 277VAC 108 ~ 120% rated output power Hiccup mode, recovers automatically after fault condition is removed Shut down o/p voltage, repower on to recover 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes PWM4012 PWM4024 PWM4036 PWM4048 3.34A 1.67A 1.12A 0.84A 40.08W 40.08W 40.32W 40.32W 500ms, 80ms 115VAC / 230VAC THD< 20%(@load 60%/115VAC, 230VAC; @load 75%/277VAC) (Please refer to TOTAL HARMONIC DISTORTION section) 86% 89% 90% 90% 0.6A / 115VAC 0.3A / 230VAC 0.25A / 277VAC COLD START 50A(twidth=270 μs measured at 50% Ipeak) at 230VAC ; Per NEMA 410 9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC <0.5W Shut down o/p voltage, repower on to recover 15 ~ 17V 28 ~ 34V 41 ~ 46V 54 ~ 60V Shut down o/p voltage, repower on to recover Tcase=40 ~ 85 (Please refer to OUTPUT LOAD vs TEMPERATURE section) Tcase=85 ±0.03%/ (0 ~ 50 ) UL8750( type HL ), UL879( for 12V,24V only), CSA C22.2 No. 250.1312; ENEC EN613471, EN61347213 independent, EN62384, IP67,BIS IS15885( for 12V,24V only), EAC TP TC 004,GB19510.1,GB19510.14 approved; Design refer to EN603351 I/PO/P:3.75KVAC I/PO/P:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55015, EN6100032 Class C (@load 60%) ; EN6100033,GB17743 and GB17625.1, EAC TP TC 020 Compliance to EN6100042,3,4,5,6,8,11; EN61547, light industry level (surge immunity LineLine 2KV),EAC TP TC 020 995.5K hrs min. Telcordia SR332 (Bellcore) ; 270.02K hrs min. MILHDBK217F (25 ) 150*53*35mm (L*W*H) 0.49Kg;30pcs/15.7Kg/1.0CUFT
DIMMING OPERATION AC/L(Brown) AC/N(Blue) SJTW 18AWG 2C Ul2464 18AWG 2C(Vo,Vo) UL2464 22AWG 2C(DIM,DIM) Vo(Red) Vo(Black) DIM(Blue) DIM(White) Dimming principle for PWM style output Dimming is achieved by varying the duty cycle of the output current. Output DC current ON TON Duty cycle(%) = 100% T Io=0A TON OFF Output PWM frequency : 1.47kHz fixed (Typ.) T 3 in 1 dimming function (for BlankType) Apply one of the three methodologies between DIM and DIM: 0 ~ 10VDC, or 10V PWM signal or resistance. Dimming source current from power supply: 100μA (typ.) Applying additive 0 ~ 10VDC 100% 90% Vo Vo DIM DIM Additive Voltage LED Strips 0.15% Duty cycle of output current (%) 80% 70% 60% 50% 40% 30% 20% DO NOT connect "DIM to Vo" 0.6V 1V 0% 0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V Dimming input: Additive voltage Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): 100% 90% Vo Vo DIM DIM LED Strips Additive PWM signal 0.15% Duty cycle of output current (%) 80% 70% 60% 50% 40% 30% 20% DO NOT connect "DIM to Vo" 6% 0% 20% 30% 40% 50% 60% 70% 80% 90% 100% Duty cycle of additive 10V PWM signal dimming input
Applying additive resistance: 100% Vo Vo DIM DIM LED Strips Additive Resistance Duty cycle of output current (%) 90% 80% 70% 60% 50% 40% 30% 20% DO NOT connect "DIM to Vo" 6K/N 10K/N 0% Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N (N=driver quantity forsynchronizeddimmingoperation) Dimming input: Additive resistance Note : 1. Min. duty cycle of output current is about 6% and the output current is not defined when 0%< Iout<6%. 2. The duty cycle of output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.
OUTPUT LOAD vs TEMPERATURE 100 100 80 60 230VAC Input only 80 60 230VAC Input only LOAD (%) 50 40 20 LOAD (%) 40 20 40 25 10 0 15 30 50 60 70 (HORIZONTAL) 40 25 0 20 45 60 70 80 85 (HORIZONTAL) AMBIENT TEMPERATURE,Ta ( ) Tcase ( ) STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC 24V Model, Tcase at 75 LOAD (%) 100 90 80 70 60 50 40 90 100 125 135 145 155 165 175 180 200 230 305 INPUT VOLTAGE (V) 60Hz Derating is needed under low input voltage. PF 1.05 0.95 1 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 0.45 0.4 0.35 0.3 20% 30% 40% 50% 60% 70% 80% 90% 100% (40W) LOAD 277V 230V 115V TOTAL HARMONIC DISTORTION (THD) EFFICIENCY vs LOAD possess superior working efficiency that up to 90% can be reached in field applications. 48V Model, Tcase at 75 48V Model, Tcase at 75 20% 18% 92% THD 16% 14% 12% 8% 6% 4% 2% 277VAC 230VAC 115VAC EFFICIENCY(%) 90% 88% 86% 84% 82% 80% 277V 230V 115V 0% 78% 50% 60% 70% 80% 90% 100% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD LOAD
LIFE TIME 120 100 LIFETIME(Kh) 80 60 40 20 0 25 35 45 55 65 75 85 Tc a s e ( )
Block Diagram PFC fosc : 50~120KHz PWM fosc : 60~130KHz I/P EMI FILTER & RECTIFIERS PFC CIRCUIT O.T.P. O.L.P. POWER SWITCHING PWM & PFC CONTROL RECTIFIERS & FILTER DIMMING CIRCUIT O.L.P. DETECTION CIRCUIT Vo Vo DIM DIM O.V.P. Mechanical Specification Case No. NPF60A Unit:mm 150 5 300±20 AC/L(Brown) AC/N(Blue) SJTW 18AWG 2C tc : Max. Case Temperature tc UL2464 18AWG 2C(Vo,Vo) UL2464 22AWG 2C(DIM,DIM) Vo(Red) Vo(Black) DIM(Blue) DIM(White) 35 5 ψ4.5 5 5 53 13 35 300±20 Recommend Mounting Direction
Installation Manual Connection for Blanktype AC/L(BROWN) AC/N(BLUE) Vo(RED) Vo(BLACK) LED Strip DIM(BLUE) DIM(WHITE) 0~10Vdc or 10V PWM or resistance Dimmer Cautions Before commencing any installation or maintenance work, please disconnect the power supply from the utility. Ensure that it cannot be reconnected inadvertently! Keep proper ventilation around the unit and do not stack any object on it. Also a 1015 cm clearance must be kept when the adjacent device is a heat source. Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a derating in output current. Current rating of an approved primary /secondary cable should be greater than or equal to that of the unit. Please refer to its specification. For LED drivers with waterproof connectors, verify that the linkage between the unit and the lighting fixture is tight so that water cannot intrude into the system. For dimmable LED drivers, make sure that your dimming controller is capable of driving these units.pwm series require 0.15mA each unit. Tc max. is identified on the product label. Please make sure that temperature of Tc point will not exceed limit. DO NOT connect "DIM to Vo". Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must requalify EMC Directive on the complete installation again. For more information about installation, Please refer to : http://www.meanwell.com/manual.html for details.