Innovation Wireless KRONOsync GPS or NTP Wireless Clock System

Similar documents
CSI MasterFormat Specification. Wireless Remote Transmitter

SECTION GPS WIRELESS CLOCK SYSTEMS

Primex Wireless, Inc. September, Wells Street Lake Geneva, WI

SECTION WIRELESS CLOCK/TONE GENERATOR SYSTEM

KRONOsync Transmitter System Operations Guide

Primex Wireless, Inc. September, Kerrisdale Blvd. Unit #4 Newmarket, ON L3Y 8V

wireless synchronized time + messaging

SAPLING WIRELESS SYSTEM

SPECIFICATIONS FOR TENDER # SUPPLY OF ONE WIRELESS CLOCK SYSTEM & ASSOCIATED COMPONENTS FOR WESTERN HEALTH

GPS Wireless Clock System User Manual. Synchronized Solutions for every type of facility SCHOOLS HEALTHCARE GOVERNMENT INDUSTRIAL CORPORATE

TIMETRAX SYNC RF ETHERNET TRANSMITTER Installation Instructions 9T1WI, S9DWXSLAUB

PYRAMID 915MHZ WIRELESS RF TRANSMITTER & REPEATER USER GUIDE. Table of Contents. Overview Installation Setup Specifications...

14 ANT-NP1 Non-penetrating Mast Antenna Kit 1 Section para " X 18" Wire Guard for 16" Clocks 2 Section para 2

Description of Changes ADDENDUM NO. 7

SECTION EMERGENCY RESPONDER RADIO COVERAGE SYSTEMS

THE HILLCREST VILLAGE HOMEOWNERS ASSOCIATION, INC. RULES FOR INSTALLATION OF ANTENNAS

18 Indoor/Outdoor Atomic Wall Clock

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT. Emergency Responder Radio Enhancement Coverage System (RES)

Summerlin South Community Association. Model Rules for Installation of Antennas in Planned Unit Developments. Satellite Antenna Resolution & Criteria

ROAM System Specification Guideline Division 16520

CLARK COUNTY FIRE CODE AMENDMENTS

LIFE SAFETY DIVISION GUIDELINE. Subject: BDA Radio Amplification Checklist Date initiated: Date revised:

Emergency responder radio coverage in new buildings. California Fire Code Section is hereby amended to read:

User Manual Digital Wireless Rain Gauge

Table of Contents. Wall Mount Installation Page 2 Double Mount Installation Page 3. Wiring Information... Page 4. Operational Instructions Pages 5-8

CONTENTS. La Crosse Technology, Ltd. Page 1

Get in Sync and Stay that Way

Clark County Fire Prevention Las Vegas Nevada

Wireless Color Weather Station

Radio Controlled timekeeping. Receives 60KHz WWVB signal transmitted by NIST in Fort Collins, Colorado

: pyramidtimesystems.com

W-DMX G4. BlackBox and WhiteBox F-1 BlackBox and WhiteBox R-512 BlackBox and WhiteBox F-2 Micro F-1 Lite Micro R-512 Lite ProBox F-2500.

ANTENNAS AND SATELLITE DISHES

EMERGENCY RESPONDER RADIO SIGNAL PERMIT APPLICATION

ADDENDUM #2 September 12, 2018

ET2000e IRRIGATION CONTROLLER

City of Irvine California Signal Booster Ordinance

WPT-3000 Wireless Probe Transmitter. Owner s Manual

CHAPTER 10 - PUBLIC SAFETY RADIO SYSTEM COVERAGE INTENT AND PURPOSE DEFINITIONS USE AND OCCUPANCY EXEMPTIONS.

MISSISSIPPI STATE UNIVERSITY Office of Planning Design and Construction Administration

M-0418 REV:0

ET2000 (500 SERIES) IRRIGATION CONTROLLER

Dakota Alert. WPT-3000 Wireless Probe Transmitter. Owner s Manual

DCPT-2500 Wireless Probe Transmitter. Owner s Manual

Honeywell. W7620 Zone Controller Water Source Heat Pump A. GENERAL RESIDENTIAL AND BUILDING CONTROL GUIDE SPECIFICATION FOR THE ENGINEER

Wireless Pressure Station with Backlight

Beat the Competition. A Remote Will Make Your Crew work smarter not harder and earn more money!!!

Architectural/Engineering Specification for a. Microwave Perimeter Intrusion Detection System

Moline Illinois CODE OF ORDINANCES. Art. IX. Miscellaneous DIVISION 3. IN-BUILDING EMERGENCY RADIO SYSTEM COVERAGE

32 CHANNEL SELECTABLE CH MHZ DOWN VOLUME

Information for Digital Antenna System (DAS)/ Bi-Directional Amplification (BDA) Systems

SPECIAL SPECIFICATION 6574 Low Power Wireless Modem

A. This section specifies procedural requirements for Shop Drawings, product data, samples, and other miscellaneous Work-related submittals.

Wireless Rain and Wireless Rain/Freeze Sensor

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio

Appearance of device and accessories may vary.

Professional UHF Rechargeable Wireless Microphone System POWER ON/OFF BATTERY CHARGE. Green Light (Full) Better Music Builder DOWN VOLUME

REVISION #1. Section. fire alarm B. C. the hot. intent of. required. manufacturer. materials. C. Warranty

Quick Start Guide. Antenna Alignment Tool AIMWLLR0-35. QSG rev 7 AIMWLLR0-35 [NRB-0200] QSG.indd 1

Engr 1202 ECE. Clean Room Project

What bands and wireless providers are served with this booster? Frequency Bands: LTE-707(Band12, 17)/LTE-781(Band13)/Cellular850

Model 532 ma/v Loop Calibrator with Loop Diagnostic Operating Instructions

B. The designated coverage areas shall include both indoor and outdoor coverage.

UNION COUNTY VOCATIONAL-TECHNICAL SCHOOLS West Hall Addition Project Raritan Road, Scotch Plains, NJ

Ambient Level Controller

Synthesized Base Station Transmitter

Operating Guide SMH 1525DT SMU 4525KT Technology Drive West Melbourne, FL RELM Wireless Corporation. All Rights Reserved CC OG 23

Wireless Transceiver - Bell & Tone Scheduling Troubleshooting Guide

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

CITY OF BROOKLYN PARK COMMUNICATIONS TECHNOLOGY SITE APPLICATION / MODIFICATION REQUEST FORM

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

Owner s Manual. Model G-223. GMRS/FRS Radio. FEATURES 22 Channels Scan 22 Key Pad Lock Call Alert Power HI/LO Roger Beep Tone

snow ski/ board 7 DAY WIRELESS FORECASTER WEATHERFX Quick Start Guide MODEL# C Lit #: /08-08

DEVAR Inc. 706 Bostwick Ave., Bridgeport CT Tel , Fax

Operator s Manual for Your Wireless Leash Guidance Trainer Series

: PERSONAL WIRELESS TELECOMMUNICATIONS SERVICE FACILITIES: REGULATIONS AND DEVELOPMENT STANDARDS:

PowerFlex 400 AC Drive Guide Specification

Building permit application requirements for prefabricated. aluminum awnings and patio/deck covers for single and two family

Installation Guide Ctek Irrigation Controller. Ctek Things That Move Data.

COMMERCIAL / INDUSTRIAL APPLICATION FOR PLAN EXAMINATION AND BUILDING PERMIT

Wireless Pressure Station

MobileRadio. Owner'sManual

SPECIAL SPECIFICATION 1806 Spread Spectrum Wireless Modem

CXT395. Making Life Easier and Safer. Owner s Manual TWO-WAY RADIO MODEL

Atomic Forecast Station with Moon Phase

3 GHz Carrier Backhaul Radio. Model: AF-3X. Tel: +44 (0) Fax: +44 (0) LINK GPS MGMT DATA DATA

CHAPTER 18 Lighting Regulations

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

OWNER S MANUAL OPERATING INSTRUCTIONS

Instruction Manual. SainSonic AX-7C FM Transmitter III. So in SONIC

SMH250D/SMU250K User s Guide

Yagi and Omni Antennas Installation Manual

HyperioN 2. Instruction Manual. Wireless Environmental / Lighting Master Controller. Product #

SP GHz Digital Wireless Speakers. User s Manual. Please read before using the equipment. Please visit for details.

SECTION SPECIFICATIONS Wireless Network Lighting Controls

RFTX-1 Installation Manual

Setup Guide. support.spruceirrigation.com.

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17

ENDUREED VIVA SERIES Specifications

Transcription:

Innovation Wireless KRONOsync GPS or NTP Wireless Clock System Innovation Wireless 5306 Beethoven St Los Angeles, CA 90066 www.innovationwireless.com 1-888-559-5565 Product Guide Specification This product specification is written According to the Construction Specifications Institute (CSI), MasterFormat, Section Format, and Page Format, contained in the CSI Manual of Practice. Reference section 16730, 16735. Reference Master Format 2004 section 275313 (27 53 13 Clock Systems) Specifier Note: The following list should be reviewed and edited by Architect/Engineer as required for specific project PART 1 GENERAL 1.1 General Requirements and Scope A. Furnish and install a complete new Wireless Synchronized Clock system. 1.2 Summary A. Wireless Clock Transmitter System B. Wireless Clocks C. Integration / synchronization with bell system 1.3 Related Divisions and Sections A. Division 16- Electrical 120V grounded outlet required for Transmitter, AC powered Analog Clocks, and Digital Display LED Clocks as applicable. B. Division 26- Electrical 120V grounded outlet required for Transmitter, AC powered Analog Clocks, and Digital Display Clocks as applicable. 1.4 References A. Innovation Wireless Operations Manual and Associated drawings. B. Definitions: 1.GPS Global Positioning System. 2.NTP - Network Time Protocol 3.FCC Federal Communications Commission 4.DST Daylight savings time CSI 27 53 13 Page 1

1.6 Submittals A. System Product: Submit data sheet for each component and system technical manual. B. Operating License: The system must be FCC licensed by the Mfg. and license provided to the end user. 1.7 Quality Assurance A. Qualifications: 1. Manufacturer: Company specializing in manufacturing of timekeeping products with a minimum of 10+ year s experience. 2. Installer: Company with documented experience in the installation of commercial timekeeping systems or factory authorization. B. Warranty: contractor to provide 1 year system performance warranty after owner occupation and manufacturer to provide a minimum of 3 year warranty on product after shipment. C. Operation Costs: No reoccurring software fees or technical phone support fees are permitted. 1.8 Substitutions A. Any proposed substitutions must be identified not less than 10 days prior to bid date. B. Clock systems using wires for time synchronization are not acceptable. C. Unlicensed systems or systems with FCC license in the name of someone other than the building owner will not be accepted 1.9 Regulatory Requirements A. Equipment and components furnished shall be manufacturer s latest model. B. System Transmitter(s) shall comply with all FCC rules. C. System shall be installed in compliance with local and state authorities having jurisdiction PART 2 PRODUCTS 2.1 Manufacturers A. Innovation Wireless: - basis of design. Website: www.innovationwireless.com B. Franklin Instruments C. If needed CSI 27 53 13 Page 2

2.2 System Description and Operation The Innovation KRONOsync transmitter obtains a time update from NTP or GPS and wirelessly sends information to system devices (clocks). The system clocks will be synchronized to the master clock displayed time and automatically update for DST time change. Transmitter shall have an option for manually setting the time and an option for providing messages to system message board devices. The system has a fail-safe design so that if GPS, NTP, or power interruption were to occur, the battery clocks will continue to operate. Upon the restoration of power, the transmitter will once again communicate with the clocks and normal operation will resume. Transmitter System shall be rack mountable and 100% programmable from the front operation panel. System programming for Time Zone, Frequency, 12 or 24 hour display, DST on/off, and scheduling of dry contacts/relay located on the Transmitter. Dry contacts used for time updates to other manufactures equipment. 2.3 Equipment Master Wireless Transmitter: The rack mountable Transmitter is to be installed in a centralized internal location. A. Master Transmitter: KRONOsync Model # 101005N basis of design. 1. Transmitter Bracket option rack mountable part # 105003 Specifier Note: If GPS is preferred use Transmitter model # 101005. Select additional GPS Cable length (if needed) for the appropriate distance between transmitter and the GPS unit. GPS unit must have an unobstructed view of the sky. 25 Cable part # 106025, 50 Cable Part # 106050, 100 Cable Part # 106100. If Wireless message board option is preferred use #101005MBN 2. NTP: Receiver box comes with a 20 Ethernet cable. 3. GPS option: GPS roof mounted receiver comes with an attached 15 cable (3m). The GPS receiver will be water tight and has a built in receiver. Additional extension cable lengths of 25, 50 and 100 are available. A GPS mounting bracket is provided for secure roof mount or side wall installation. 4. Antenna: 6 broadcasting antenna (included) is attached to the rear of the transmitter. An external mounted broadcasting antenna option on model 101005X (external - 5 tall) is available for extremely large schools or campus environments. B. Analog Clocks: Analog clocks will be battery operated using 2 D cell batteries provided by the manufacturer or AC power based on specification. All clocks shall be wall mounted. Clocks can be added or expanded in any area within range of transmitter. Clocks shall not dependent on other clock devices to synchronize. 1. Clock Models: (Battery/Electric) CSI 27 53 13 Page 3

a. 13 Standard Model # 210001 ( #312001 120VAC, #311001 24VAC ) b. 16 Standard Model # 220001 (#322001 120VAC, #321001 24 VAC) c. Digital Clock options: 120V, 24V(see website for model # s) d. Analog Clock finish options: Brushed Aluminum and Wood Clocks are available: (see website for specific model # s) e. 24 Outdoor clock option. (see website for model # s) f. Custom Logo s options are available for analog clocks. 2. Wire guards: Provided to protect clocks in harsh environments: a. 16 x 16 inch Wire Guard for 13-inch clocks. Model #104001 b. 19 x 19-inch Wire Guard for 16-inch clocks. Model #104002 3. Message Board option: Single line model # 610001, Dual line model #610002, PC based messaging software #610003. The system operates by having a PC loaded with the IW software communicating through the NTP connection to the KRONOsync transmitter. (see website for additional product information) PART 3 - EXECUTION 3.1 Examination Verify that construction is complete in spaces to receive equipment and that rooms are clean and dry. Verify that 120-volt electrical outlet is located within 6 feet of location of transmitter and the outlet is operational and properly grounded. Verify that all 120-volt electrical outlets for any AC powered clocks are located at the exact installation point and the outlet is operational and properly grounded. 3.2 System Installation Install in accordance with manufacturer s installation manual furnished with system. Install transmitter system then install clocks. A. Transmitter 1. The NTP receiver shall be located next to or sit on top of the Transmitter. Connect the RJ45 Ethernet cable from your computer network to back of the NTP receiver. Connect the NTP receiver to the Transmitter. The NTP receiver does not require individual power supply 2. The GPS receiver shall be mounted on the outside wall of the building, roof, or inside window. In all cases the GPS unit must have a clear view of the sky. If mounted on exterior side wall, there is to be no overhanging structure that can block its view of the sky. If located on the roof, it must be at a height that will prevent it from contacting potentially standing water, or buried under snow. If inside window mounted, the class cannot contain chemical shielding. (Low E) 3. When power is first applied to the master transmitter, the power light will flash and it will search for a valid NTP or GPS signal and upon receipt, it will CSI 27 53 13 Page 4

set the internal clock of the transmitter. The transmitter will then transmit time to all receiving devices. A. Analog Clocks 1. For battery clocks, insert two D cell batteries. The receiver will search for a signal from the transmitter by scanning all frequencies. Upon receipt of the signal, the clock will store the frequency in memory and set the clock to the exact second of the transmitter. The clock hands will move in a quick clockwise motion until they get to the transmitter time. It can take a few minutes for the hands to set to the exact time. B. Digital Clocks 1. Connect the DC adapter (supplied with each digital clock) to the appropriate power source. The built in receiver will search for a signal from the transmitter. Upon receipt of signal confirmation, the digital clock will synchronize to the exact time of transmitter. D. Integration with other master clocks on the PA system or bell system. 3.3 Cleaning 1. Program relays located on transmitter #101005N to provide time synchronization via 2 wire connection with the PA system / Bell system. Consult PA system manufacturer for 2 wire integration requirements. Prior to final acceptance, clean exposed surfaces of all system components. 3.4 Manufacturer Services Provide phone technical assistance at no expense or annual fee as required. Operation manuals can be found at innovationwireless.com. 3.5 Field Inspection Prior to final acceptance, inspect entire system to ensure proper functioning and synchronization of components. Contact Innovation Wireless at 1-888-559-5565 CSI 27 53 13 Page 5