GPS Satellite-Controlled Clock

Similar documents
Specifications subject to change without notice Heartbeat of the Smart Grid

Model 1133A Power Sentinel. with. Digital Signal Analysis SYNCHRONIZED POWER QUALITY/REVENUE STANDARDS

Arbiter Systems, Inc Vendels Circle, Suite 121 Paso Robles, CA USA

Model 931A Power System Analyzer. Model 930A Three Phase Power Analyzer. Model 929A Three Phase Power Meter. with. Digital Signal Analysis

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

MODEL 1094B GPS SUBSTATION CLOCK

GPS10RBN - 10 MHz, GPS Disciplined Rubidium Frequency Standard

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

MODEL 1083A SATELLITE-CONTROLLED FREQUENCY STANDARD

MODEL 1083B SATELLITE-CONTROLLED FREQUENCY STANDARD / COMPARATOR

MODEL 1201B/C GNSS SYNCHRONIZED CLOCK OPERATION MANUAL

MODEL 1205B/C MODEL 1206B/C GNSS SYNCHRONIZED CLOCK OPERATION MANUAL

[ tima-datasheet-en v11.1 ]

GPS10R - 10 MHz, GPS Disciplined, Rubidium Frequency Standards

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

Digital Instruments S.r.l. GPS-MXS. Multireference Time-Frequency

GPS Time and Frequency Reference Receiver

MODEL 1202B/C GNSS SYNCHRONIZED CLOCK OPERATION MANUAL

ExacTime GPS Time & Frequency Generator

satech SynchroStar GPS 200 Series

Reason RT431. GE Grid Solutions. GPS Precision-Time Clock. Precise Time Synchronization. Compact Design. Hardened for Industry. Time Synchronization

Enabling Tomorrow s Technology Today

ONCORE ENGINEERING NOTE M12 Oncore

Reason RT430/RT434. GE Grid Solutions. GNSS Precision-Time Clocks. Precise Time Synchronization. Flexible Design. Hardened for Industry.

The FEI-Zyfer Family of Modular, GPS-Aided Time & Frequency Systems

HESP-E-AO-PS Laboratory Diode Driver (For use with Kigre AO-1010 and AO-610 lasers)

ONCORE ENGINEERING NOTE SL Oncore

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Arbitrary/Function Waveform Generators 4075B Series

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

TG1010A AIM & THURLBY THANDAR INSTRUMENTS. 10MHz programmable DDS function generator. Direct Digital Synthesis

N. TEST TEST DESCRIPTION

Industriefunkuhren. Technical Manual. System 6844 and 6844RC. (GPS and Sub-Master) For Housing Versions. 1U / 3U / Table / Wall ENGLISH

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Model XL-AK Time and Frequency Receiver. Serial No. September 17, 2001 Revision A

Npaq Series Drive Racks

J kw AM Transmitter

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

PM 6685 PM 6685R Universal Frequency Counter Rubidium Frequency Counter Calibrator

Arbitrary/Function Generator AFG1000 Series Datasheet

LT-800 Stationary FM Transmitter

5V SERIES DC LOADS 5V SERIES DC LOADS. Key features:

Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

SOLUTIONS FOR AN EVOLVING WORLD RFL Programmable FSK Powerline carrier system

TECHNICAL SPECIFICATION FOR RF (TEST &MEASUREMENT) DEVICE

MN5020HS Smart GPS Antenna Module

Loop & Magnetic Field Coil

TCG 01. TIME CODE GENERATOR User Manual. 9 th Edition

120W UHF Transmitter/Repeater

INSTRUCTION MANUAL PLUG AND SEND WIRELESS MONITOR SYSTEM TABLE OF CONTENTS

HMC-T2220B. Portable & Battery Operated! Portable Synthesized Signal Generator, 10 MHz to 20 GHz. Instrumentation Product Support at


Universally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Instant value. Extreme values ors statistic measurements

T108, GPS/GLONASS/BEIDOU Time Server

Universally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Extreme values ors statistic measurements

LT-800 Stationary Transmitter

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Charge Meter. Electronics & Software. Universally Applicable for Piezoelectric Measuring Technology. Type 5015A...

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

NP2500 Constant Current Front-End Power Supply 150 Vac to 264 Vac Input; 42 Vdc to 58 Vdc Output

Thruline RF Directional Wattmeters

The wireless alternative to expensive cabling...

External RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual

EB-230. Ultimate TRANSYSTEM INC. EB-230 Data Sheet

LCR Meter. Product Specification

Model 7000 Low Noise Differential Preamplifier

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

Technical Specification

Industriefunkuhren. Technical Manual. Model 6842 GPS. Slim Line System ENGLISH. Version: Valid for Devices 6842 GPS with FIRMWARE

MODEL 940A TIMING SYSTEM ANALYZER USER S MANUAL

NI PXI-2521 Specifications 40-Channel DPST Relay Module

NI PXI-2532 Specifications

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet

ANTENNA TUNER CONTROLLER MODEL ATC-550. Installation and Operating Instructions

NI PXI/PXIe-2532 Specifications

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

X-Band Redundant LNA Systems

Rubidium Frequency Standard Model AR133A Ruggedized Low Profile

The RCB-2000 is a compact receiving system that combines two high-performance telemetry RF sections.

T 160S. User Guide TIME CODE SATELLITE GPS. TIME CODE READER / GENERATOR SMPTE to MTC / MTC to SMPTE MMC /WIRELESS TC. T 160S Version1.

MODEL 3810/2 Line Impedance Stabilization Network

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

R&S OSP Open Switch and Control Platform Specifications

Surge Generator for MIL-STD 1275

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer.

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

Series OLH10KD 10kW HIGH VOLTAGE POWER SUPPLIES

NI PXI-2530 Specifications

SEL Radio Accessories Guide

High Performance Process & Temperature Controllers

T200, PTP/IEEE 1588 Grandmaster Clock and

MediaMatrix X-Frame 88

The wireless alternative to expensive cabling...

B850 Boiler House Energy Monitor

Transcription:

Model 1093A/B/C GPS Satellite-Controlled Clock The Arbiter Systems, Inc. Model 1093A/B/C GPS Satellite-Controlled Clock is a GPS timing source for applications not requiring the ultimate 100 ns accuracy of our higher-performance models. The Model 1093A/B/C has 500 ns worst-case accuracy to meet the requirements of a broad range of applications. The Model 1093A has two LEDs to monitor operating status. The Model 1093B adds an LCD setup/status display and a keyboard. The Model 1093C also includes a large (20 mm or 0.8 in.) LED time display. In all versions, twelve receiver channels provide optimum performance. Two pluggable terminal strip outputs provide unmodulated IRIG-B and 1 PPS. A modulated IRIG-B output (1093opt92) is available on a third pluggable terminal strip output. These outputs have substantial drive capability to easily drive multiple loads in parallel. These outputs are configurable to provide other output signals or an event-capture input. The GPS Data Backup Battery is now included in the Model 1093A/B/C. This feature improves acquisition time to as little as 15 seconds after a brief power loss by supplying constant power to the real-time clock and RAM in the GPS receiver module. Other available options include Four Additional Configurable Outputs (1093opt03); High Drive IRIG-B Outputs (1093opt27); Power System Time, Frequency, and Phase Monitor (1093opt28); one Form C (SPDT) fail-safe, LOCKED relay (1093opt93) that is compatible with 129 Vdc digital fault recorder inputs; plus many more. An event-capture input is standard, and may be wired to one of the output connectors or used for synchronizing data collection on an external computer via the serial port. This input has 1 µs resolution. A programmablepulse output may be used to generate an output pulse at the IRIG-B unmodulated or the 1 PPS outputs in addition to the AUX OUT on the RS-232 Port. Standard power options include 85 to 264 Vac/110 to 275 Vdc, with either IEC-320 or terminal strip inlet, and 10 to 60 Vdc with terminal strip inlet. The terminal-strip versions have a surge-withstand network designed to meet ANSI/IEEE C37.90-1 and IEC801-4 specifications. Power configurations may be retrofitted in the field. Also available, the Model 1092A/B/C GPS Satellite- Controlled Clock provides the same performance and functionality as the Model 1093A/B/C, but has a small, tabletop chassis and an external (wall-mount) power supply. PD0047500B Tel: +1.805.237.3831 Fax: +1.805.238.5717 E-mail: sales@arbiter.com Internet: http://www.arbiter.com 1

Receiver Characteristics I/O Configuration Timing Accuracy Specifications apply at the 1 PPS output, in the presence of Selective Availability (SA), as of date of publication. UTC/USNO ±500 ns peak; < ±100 ns typical (SA off) Position Accuracy 10 meters, rms, 90% confidence Satellite Tracking Twelve (12) channel, C/A code (1575.42 MHz). Receiver simultaneously tracks up to twelve satellites. Results from all tracked satellites are averaged in Position-Hold Mode or, with Position- Hold Mode off, using least-squares estimation. Acquisition 150 seconds typical, cold start 15 minutes, 90% confidence, cold start 40 seconds, typical, with almanac < 1 month old 15 seconds, typical, with ephemeris < 4 hours old The GPS Data Backup Battery is included in the Model 1093A/B/C. This feature improves acquisition time by supplying constant power to the real-time clock and RAM in the GPS receiver module. Connectors Two standard; one IRIG-B Unmodulated and one 1 PPS; bus driver, 5 V CMOS; 10 ohms source impedance; ±75 ma drive capability; pluggable terminal strip. 400 V, 220 ma, 1 watt power dissipation open-drain FET drivers can also be fitted; contact factory Optional equipment may be shown Event A Input One event timer channel with 1 µs resolution is standard. This function may be driven by the start bit of a received character on the serial port, or (by internal connection) an external 5 V CMOS/TTL signal at one of the terminal strip connectors. Programmable Pulse Output One programmable output pulse (by a jumper connection) that may be output on a terminal strip connector or the AUX OUT pin on either RS-232 Port. Four modes: Every 1 to 60,000 seconds, starts top of the minute Hourly at a specified offset Daily at a specified time of day One shot at a specified time of year Pulse duration is programmable from 0.01 to 600 seconds, except in one-shot mode, where the output is Low prior to the specified time and High thereafter. I/O Options IRIG-B Modulated (1093opt92): bus driver, 4 Vpp, 20 ohms source impedance; drives a 50-ohm load at 3 Vpp; pluggable terminal strip Second RS-232 Port (1093opt19): In normal mode, provides all the same capabilities as the standard RS- 232C serial port except there is no AUX IN line. AUX OUT provides programmable pulse function at RS-232 levels. Relay contacts (1093opt93): 1 set, Form C (SPDT) fail-safe, 0.3 A at 130 Vdc; Locked function. 2 Tel: +1.805.237.3831 Fax: +1.805.238.5717 E-mail: sales@arbiter.com Internet: http://www.arbiter.com

Interface Power Requirements Operator Display Functions Status LEDs Keypad Setup System RS-232 Status LEDs (Models 1093A/B/C) 2 x 20 character supertwist LCD (Models 1093B/C) 14 mm (0.56 in.) LED; 9 digits (Model 1093C) UTC or local Time Position: latitude, longitude, altitude Receiver and clock status 1 PPS (input) deviation Event time Operate (green) Unlocked (red) 8 keys; select display functions or setup menus (1093B/C) Local time offset Output code select: Local/UTC Daylight Saving Time (Set Summer Time): Off/On/Auto USA/Auto EUR/Auto CUS Backlight control: On/Off/Auto Event input: Event/1 PPS Programmable Pulse setup Antenna delay Out-of-Lock time: 1 to 99 minute(s), Off, or Zero Delay Auto-Survey: On/Off, Survey duration Position Hold: On/Off, Position Auto/ Manual Option Configuration and Setup Serial port: RS-232 1200 to 19200 baud; 7 or 8 data bits; 1 or 2 stop bits; even/odd/no parity Male 9-pin D-subminiature (TXD, RXD, AUX IN, AUX OUT) Has Interrogate (normal) and six Broadcast modes: standard ASCII (IRIG-J), Vorne large-display, status/alarm, extended ASCII, event data, and ASCII with time-quality AUX OUT can provide programmable pulse function at RS-232 levels RS-422/485 driver also available; contact factory Second RS-232 port available (1093opt19) Standard Voltage 85 to 264 Vac, 47 to 440 Hz, 20 VA max. or 110 to 350 Vdc, 15 W maximum IEC-320 with fuse and mating cordset. Specify cordset P01-P10 Tel: +1.805.237.3831 Fax: +1.805.238.5717 E-mail: sales@arbiter.com Internet: http://www.arbiter.com 3 Inlet General Physical Size Weight Antenna 1 RU rack mount or tabletop; 260 mm deep FMS. Rack mounts included. 508 x 381x 203 mm (20 x 15 x 8 in.), shipping 2 kg (4.5 lbs), net 5.5 kg (12 lbs), shipping 0.75 in. pipe (1 in. - 14 marine) thread Cable Connection: F-type Size: 77.5 dia. x 66.2 mm (3.05 x 2.61 in.) Weight: 170 grams (6.0 oz) Antenna Cable RG-6 type, 15 m (50 ft) provided Weight: 0.69 kg (1.52 lbs) per 15 m Environmental Temperature Operating: 0 to +50 C (-20 to +70 C typical) Nonoperating: -40 to +75 C Humidity Noncondensing EMC Radiated susceptibility: passes walkie-talkie test Conducted emissions: power supply complies with FCC 20780, Class A and VDE 0871/6.78 Class A Surge withstand capability (SWC), power inlet: designed to meet ANSI/IEEE C37.90-1 and IEC 801-4 Certifications and Approvals CE mark/label and certificate

Options Except as noted otherwise, only one I/O Option may be installed. Option Description I/O Options Four Additional Configurable Outputs 1093opt03 1 Second RS-232 Port 1093opt19 3 Four Configurable Fiber-Optic Outputs 1093opt20A Eight-Channel High-Drive IRIG-B Output 1093opt27 1 Power System Time, Frequency and Phase Monitor 1093opt28 Four Additional Outputs with Dry Contact and +25/50 Vdc 1093opt29 Network Time Protocol (NTP) / Precision Time Protocol (PTP) Server 1093opt34 IRIG-B Modulated Output 1093opt92 3 Out-of-Lock Relay 1093opt93 3 RS-422/485 Driver 1093opt94 3 Four BNC Output Connectors (Parallel to Pluggable Terminal Strip) 1093opt95 1 PPS Output Reconfigured to Programmable Pulse 1093opt96 3 IRIG-B Output Reconfigured to Programmable Pulse 1093opt97 3 1 PPS Output Reconfigured to Event Input 1093opt98 3 Power Options (select only one) IEC-320 Power Inlet, 85 to 264 Vac, 110 to 370 Vdc 1093opt07 Terminal Power Strip, Surge Withstand, 10 to 60 Vdc 1093opt08 Terminal Power Strip, Surge Withstand, 85 to 250 Vac, 110 to 350 Vdc 1093opt10 General Options LCD Backlight On/Off Switch 1093Bopt01 1093Copt01 1093Aopt04 1093Bopt04 Accessories Included Description GPS Antenna, pipe mountable AS0087800 15 m (50 ft) RG-6 Antenna Cable CA0021315 19 in. Rack Mount Kit AS0028200 Operation Manual AS0035400 Power Cord P09 Available Description Power Cord P01-P10 GPS Antenna Mounting Kit AS0044600 15 m (50 ft) RG-6 Antenna Cable CA0021315 30 m (100 ft) RG-6 Antenna Cable CA0021330 45 m (150 ft) RG-6 Antenna Cable CA0021345 60 m (200 ft) RG-6 Antenna Cable CA0021360 75 m (250 ft) RG-6 Antenna Cable CA0021375 21 db In-Line Preamplifier AS0044700 2 Antenna Grounding Block Kit AS0048900 GPS Surge Protector AS0094500 GPS Antenna Cable Splitter AP0013400 BNC (Male) Breakout to 100 mm Wires AP0003400 BNC (Female) Breakout to 100 mm Wires AP0008900 300 m (1000 ft) Roll RG-6 Cable WC0005000 RG-6 Stripping Tool TF0013200 RG-6 Type F Crimp Tool TF0006400 RG-6 Type F Male Crimp-on Connector CN0027700 300 m (1000 ft) Roll RG-11 Cable WC0004900 RG-11 Stripping Tool TF0013300 RG-11 Type F Crimp Tool TF0006000 RG-11 Type F Male Crimp-on Connector CN0027800 19 in. Rack Slide Kit AS0033100 24 in. Rack Mount Kit AS0056600 1 Modulated outputs also require Option 92 2 Used for cable length greater than 75 m (250 ft) 3 May be combined with other I/O options 4 Tel: +1.805.237.3831 Fax: +1.805.238.5717 E-mail: sales@arbiter.com Internet: http://www.arbiter.com

Cordset and Plug Styles The following are the available IEC-320 mating cordset plug style and specifications: Option Voltage No. Country Specification Rating P01 Continental Europe CEE 7/7 220V P02 Australia/NZ/ AS 3112- PRC 1981 240V P03 U.K. BS 1363 240V P04 Denmark Afsnit 107-2-01 240V P05 India BS 546 220V P06 Israel SI 32 220V P07 Italy CEI 23-16/VII 1971 220V P08 Switzerland SEV 1011.1959 220V P09 North America NEMA 5-15P and ROC CSA C22.2 #42 120V P10 Japan JIS8303 120V Tel: +1.805.237.3831 Fax: +1.805.238.5717 E-mail: sales@arbiter.com Internet: http://www.arbiter.com 5