POWER SYSTEM II LAB MANUAL

Similar documents
DEPARTMENT OF ELECTRICAL ENGINEERING BENGAL ENGINEERING AND SCIENCE UNIVERSITY, SHIBPUR

Relay Types and Applications Dr. Sasidharan Sreedharan

Power systems Protection course

Level 6 Graduate Diploma in Engineering Electrical Energy Systems

A NEW DIRECTIONAL OVER CURRENT RELAYING SCHEME FOR DISTRIBUTION FEEDERS IN THE PRESENCE OF DG

Power System Protection Manual

Power System Protection Part VII Dr.Prof.Mohammed Tawfeeq Al-Zuhairi. Differential Protection (Unit protection)

UNIT II MEASUREMENT OF POWER & ENERGY

Types CDG 11 and CDG 16 Inverse Time Overcurrent and Earth Fault Relay

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

CIRCUITS THAT ARE AVAILABLE ON LODAR RECEIVERS Features listed below are available on 92 Series and 93 Series

BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY

EE402-Protection and Switchgear Dept. of EEE

Overcurrent Protective Relays

Earth Fault Relay EFSPL-1A/5A

Type KLF Generator Field Protection-Loss of Field Relay

Electrical Protection System Design and Operation

3.0 CHARACTERISTICS. Type CKO Overcurrent Relay. switch, which allows the operation indicator target to drop.

Busbars and lines are important elements

Meters. Ampere Meter. Volt Meter. Watt Meter. Var. Meter. Power Factor Meter. Frequency Meter. Demand Meter. Meter Relay.

PRODUCT / TEST MANUAL 2V162K4 VOLTAGE REGULATOR RELAY

R10. III B.Tech. II Semester Supplementary Examinations, January POWER SYSTEM ANALYSIS (Electrical and Electronics Engineering) Time: 3 Hours

POWER SYSTEMSLAB YEAR SEM EEE. Dr. J. Sridevi

Back to the Basics Current Transformer (CT) Testing

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

Transmission Lines and Feeders Protection Pilot wire differential relays (Device 87L) Distance protection

Experiment 45. Three-Phase Circuits. G 1. a. Using your Power Supply and AC Voltmeter connect the circuit shown OBJECTIVE

Relay operating principles

PRODUCT/TEST MANUAL 2V162K12 VOLTAGE REGULATOR RELAY

Instruction Manual. Description Calibration. Excitation Sensor and Reverse Power Relay

Unit Protection Differential Relays

Synchronous Machines Study Material

DIGITAL EARTH FAULT RELAY

System Protection and Control Subcommittee

Transmission Line Protection Objective. General knowledge and familiarity with transmission protection schemes

Type CVX and CVX-1 Synchro-Verifier Relays

In this lecture. Electromagnetism. Electromagnetism. Oersted s Experiment. Electricity & magnetism are different aspects of the same basic phenomenon:

DIGITAL EARTH FAULT RELAY

Transformer Protection

Data. Dr Murari Mohan Saha ABB AB. KTH/EH2740 Lecture 3. Data Acquisition Block. Logic. Measurement. S/H and A/D Converter. signal conditioner

Single-Phase Instrument Transformers

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

Electrical Power Systems

Transmission Protection Overview

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

STATIC EARTH FAULT RELAY

Conceptual Physics Fundamentals

Type CAEM 21 Battery Earth Fault Relay

NERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

ELECTRICAL POWER TRANSMISSION TRAINER

CHAPTER 8: ELECTROMAGNETISM

Electromagnetic Induction - A

1. Explain in detail the constructional details and working of DC motor.

REQUIRED SKILLS AND KNOWLEDGE UEENEEG101A. Electromagnetic devices and circuits. Topic and Description NIDA Lesson CARD # Magnetism encompassing:

In Class Examples (ICE)

COPYRIGHTED MATERIAL. Index

MODEL POWER SYSTEM TESTING GUIDE October 25, 2006

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network

Laboratory Tutorial#1

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

WD series DIN Rail or Screw Mounted Protective Relays

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM. Unit Objectives. Unit Objectives 2/29/2012

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

Power Plant and Transmission System Protection Coordination of-field (40) and Out-of. of-step Protection (78)

Synchronism Check Equipment

Conventional Paper-II-2011 Part-1A

Application and Commissioning Manual for Numerical Over Current Protection Relays Type MIT 121/131 CONTENTS PAGE APPLICATION 2-4 INSTALLATION 5-11

Rajasthan Technical University, Kota

Introduction to MS150

Improving Transformer Protection

Power System Protection. Dr. Lionel R. Orama Exclusa, PE Week 3

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

ELECTRICAL POWER ENGINEERING

CDV 22, 62. Voltage Controlled Overcurrent Relay GRID PROTECTION

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans. Electronic Measurements & Instrumentation

1 Introduction General Background The New Computer Environment Transmission System Developments Theoretical Models and Computer Programs

Electrical Drives I. Week 4-5-6: Solid state dc drives- closed loop control of phase controlled DC drives

REV NO EXPERIMENT NO 1 AIM: To perform open and short circuit tests on 1-phase transformer and to calculate efficiency. Apparatus required:

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy

Sine waves by far the most important form of alternating quantity important properties are shown below

Type VDG 13 Undervoltage Relay

Feedback Devices. By John Mazurkiewicz. Baldor Electric

INSTRUCTIONS. GE Protection and Control. 205 Great Valley Parkway. Malvern, PA TRANSFORMER DIFFERENTIAL RELAY

Type MCAG 14, 34 T&D. High Stability Circulating Current Relay

Reyrolle Protection Devices. 7PG11-18 Alpha Electromechanical Relays. Siemens. Answers for energy.

Testing Potential Transformers

Module 5. DC to AC Converters. Version 2 EE IIT, Kharagpur 1

Ballari Institute of Technology & Management Ballari Department of Electrical and Electronics Engineering. Vision & Mission of the Institute

UNIVERSITY OF JORDAN Mechatronics Engineering Department Measurements & Control Lab Experiment no.1 DC Servo Motor

Electrical And Electronics Engg

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

Experiment 6. Electromagnetic Induction and transformers

GATE 2000 Electrical Engineering

INSTRUCTIONS. GE Protection and Control. 205 Great Valley Parkway Malvern, PA GE K-45307K TRANSFORMER DIFFERENTIAL RELAYS WITH

Power System Laboratory Manual

Application and Commissioning Manual for Numerical Over & Under Voltage Protection Relays Type MVT181 CONTENTS PAGE APPLICATION 2-7 INSTALLATION 8-16

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy

A 11/89. Instruction Manual and Experiment Guide for the PASCO scientific Model SF-8616 and 8617 COILS SET. Copyright November 1989 $15.

Transcription:

POWER SYSTEM II LAB MANUAL (CODE : EE 692) JIS COLLEGE OF ENGINEERING (An Autonomous Institution) Electrical Engineering Department Kalyani, Nadia

POWER SYSTEM II CODE : EE 692 Contacts :3P Credits : 2 1. Study on (i) on load Time Delay Relay (ii) off load Time Delay Relay 2. Polarity, Ratio and Magnatisation Characteristics Test of CT & PT 3. Testing on (i) Under Voltage Relay and (ii) Earth Fault Relay 4. Study on D C Load Flow 5. Study of A C Load Flow Using Gauss Seidel Method 6. Study of A C Load Flow Using Newton Raphson Method 7. Study on Economic Load Dispatch 8. Study of Transformer Protection by Simulation 9. Study of Generator Protection by Simulation 10. Study of Motor Protection by Micon Relay 11. Study of Different Characteristics of Over Current Relay

Experiment No: 01 Title: Testing of Under Voltage Relay. Objective: To study the operation of under voltage relay. Theory: Under voltage protection is provided for AC circuit, bus bars, motors, rectifiers, transformers etc. This type of relay is necessary for voltage control and reactive power control of network busses and load busses. Under voltage relay can have instantaneous characteristics (for armature type construction) or inverse characteristics (Induction, disc type construction) depending upon design. The relay energized by voltage to be monitored via potential transformers. The operating voltage of the relay adjusted by proper tap setting and by proper selection of voltage ratio of potential transformers. Relays have multiple no of power free NO & NC contacts. When applied voltage across the relay more than the set point voltage relay become SET that is NO contacts become close and NC become open. When operating voltage less than set point voltage relay become RESET that is all auxiliary contacts back it is original state. 220V Supply Main Variac Relay Back Plane Connection Instrument and Equipment Used SL. No Name of Apparatus Quantity Type/Specification Maker`s Name

Procedure: 1. Measured Voltage is connected to terminal no 9 & 10. Two Auxiliary powers free NO contacts between 1 & 2 also between 2 & 3. 2. Relay energised directly from a variac. Connect the circuit as per given diagram. 3. Increase the supply voltage gradually. 4. Not down at what voltage relay becomes turn on that is indicator glow. This voltage known as PICK UP voltage. 5. Set the relay FLUG 6. Increase the supply Voltage up to 100 Volt. There from start to decrease the applied voltage. Not down at what voltage relay become turn OFF. Flag reset and indicator stop glowing. This voltage known as DROP OFF voltage. Observation and Result: PICK UP voltage DROP OFF voltage Note down all technical details of the relay Conclusion / Discussion Write your comments on the results obtained and discuss the discrepancy, if any.

EXPERIMENT NO: 02 TITLE: Study of different characteristics of inverse over current relay. OBJECTIVE: To study the characteristics of inverse time over current and associated earth fault relay. THEORY: This type of relay works on the induction principle and initiates corrective measures when current in the circuit exceeds the predetermined value. The actuating source is a current in the circuit supplied to the relay from the secondary winding of a current transformer. These relay used on AC circuit only and can operate for fault flow in either direction. It consists of a metallic (Aluminium) disc, which is free to rotate in between the poles of two electromagnets. The upper electromagnet has a primary and secondary winding. The primary is connected to the secondary of a CT to the line to be protected and is tapped as intervals. The tapping is connected to a plug setting bridge by which the number of active turns on the relay operating coil can be varied, there by giving the desired current setting. The secondary windings are energised by induction from primary and is connected in series with the winding on the lower electromagnet. The control torque provided by a control spring. The spindle of disc carries a moving contact can be adjusted to any value between 0 0 to 360 0. The adjusting this angle, the travel of the moving contact can be adjusted and hence the relay can be given any desire time setting. There is more common terminology of the relay. Pick up current: It is the minimum current in the relay coil at which the relay starts to operate. Current setting: It is often desirable to adjust the pick up current to any desire value. This is known as current setting and usually achieved by the use of tapping on the relay operating coil. The taps are brought out to a plug bridge in front face of the relay. Pick up current = Rated secondary current of CT * current setting

Plug setting multiplier ( PSM ): It is the ratio of fault current in relay coil to the pickup current. PSM = Fault current in the relay coil / (Rated secondary current in CT * current setting) Time setting multiplier (TSM): It is the ratio of actual operating time to time found from time vs PSM curve for a particular value of fault current. Inverse time characteristics: In this type operating time is approximately inversely proportional to the magnitude of actuating current in relay. It never operate when the current in the relay less than pick up current. CIRCUIT DIAGRAM: INSTRUMENT AND EQUIPMENT USED: 01 02 03 Sl. No Name of the Apparatus Quantity Type/Specification Marker s Name

PROCEDURE: 1) Connect the circuit as per circuit diagram. 2) Chose the proper current setting and time setting multiplier of the relay. 3) Increase the current variac up to a value more than the pick up current then switch off the current source without disturbing variac. Reset the timer. 4) Switch on the power of current source. After some time interval relay become off and current source become reset automatically. 5) Note down the current value and time value. 6) Repeat the experiment twice for same current value. 7) Change the input current and repeat the experiment for same current setting and time setting multiplier. 8) Draw the curve PSM vs Time and find out the error. OBSERVATION AND RESULT: Note down all technical details about the relay printed on the front panel. No of Obser. 01 02 03 04 05 06 07 08 09 Relay current setting Fault current PSM TSM Time of interval Actual given time % Error CONCLUSION / DISCUSSION: Write your comment on the result obtained and discuss the discrepancy, if any.

EXPERIMENT NO: 03 TITLE: Study of Instantaneous earth fault relay. OBJECTIVE: To study the characteristics and operation of instantaneous earth fault relay. THEORY: This is a solenoid type relay. It consists of a solenoid and a moving iron plunger arranged as shown under the normal operating condition, the current trough the relay coil is such that it holds the plunger by gravity or spring in the bottom position. On a occurrence of a fault, the current through the coil becomes more than the pick up value causing the plunger to be attracted to the solenoid. The upward movement of the plunger close the trip circuit. The minimum current at which the solenoid attracted is known as pickup current. Current setting usually achieved by the use of tapping on the relay operating coil. The taps are brought out to a plug bridge on the front panel of the relay. The plug bridge permits to alter the no of turn on the relay coil. Relay has multiple no of power from NO & NC contacts. The relay is energized by the secondary of CT. When the relay current more than the set point current, relay become on. NO contact become close and NC become open. This type of relay is one in which no intentional time delay is provided. In this case the relay contacts are closed immediately after current in the relay coil exceeds the minimum calibrated value. Although there will be a short time interval between the instant of pickup and closing of relay contacts. Relay operating time less than 0.1 seconds.

CIRCUIT DIAGRAM: INSTRUMENT & EQUIPMENT USED: 01 02 03 Sl. No Name of the Apparatus Quantity Type/ Specification Marker s Name PROCEDURE: 1) Connect the circuit as per circuit diagram. 2) From current variac output connect to relay terminal no 9 & 10 from relay terminal no 1 & 2 feedback to timer input terminals. Set the timer at NO mode. 3) Chose the proper current setting of the relay. 4) Increase the current variac up to a value more than the pickup current then switch off the current source without disturbing the variac. Reset the timer. 5) Switch on the power of current source again. Within a fraction of seconds relay become reset and current source become reset automatically. 6) Note down the current value and time value. 7) Repeat the experiment twice for same current value change the current setting and repeat the experiment again. 8) Find out the error.

OBSERVATION & RESULT: No of observation Relay current setting 01 02 03 04 05 06 07 08 Fault current Time of interval CONCLUSION / DISCUSSION: Write your comments on the results obtained and discuss the discrepancy, if any.

EXPERIMENT NO: 04 TITLE: Polarity, Ratio and magnetisation characteristics test of CT and PT. OBJECTIVE: Testing of Polarity, Ratio and magnetisation characteristics of current Transformer and Potential Transformer. THEORY: Current Transformer and potential Transformer are known as instrument transformer. In a high voltage and high current circuit direct measurement of voltage, current and other electrical parameter instrument transformer are used. PT is connected to the main bus of the associated power system, stepped down secondary voltage is measured by the instrument displayed actual high voltage after proper calibration. Primary of CT connected in series with the equipment whose current is to be measured and the secondary current measured by the instrument displayed actual high primary current after proper calibration. Using CT and PT we can electrically isolate the measuring devices from the main circuit and measuring device can be placed any far distance in control room. In case of a PT primary voltage rating according to the high voltage circuit but secondary voltage rating is fixed to 110 V. In case of CT primary rating will be according to the high current in primary circuit but secondary current rating is fixed to either 1A or 5A. VA burden of CT and PT is being calculated from their voltage and current loading to the maximum polarities of transformer define the phase shift between two sides, which is either 0 0 or 180 0. There are two type of CT one is measuring CT and other is protection CT. When a single CT output is fed to an ammeter or a PT output fed to a voltmeter there is no need to know the polarity of transformer. But when CT and PT connected in star or delta in case of three phase circuit they must be connected according to their polarity. Performing polarity test we can find out the symmetrical terminals between primary and secondary wingding of a CT and PT. Using ratio test we can find out the voltage ratio for PT and current ratio for CT between primary and secondary at different point throughout its full operating

range. Through this test we can also find out whether it is constant at all point or not. Transformer core must not be saturated within its operating zone. If it saturated then due to change of input voltage or current in primary make no change in secondary that cause the error in measurement. We can determine its property from the data of ratio test. If the transformer ratio never changes between its full operating ranges means that core of the transformer is healthy condition. Circuit diagram for Polarity test of PT using AC supply: Circuit diagram of ratio test of PT using AC supply:

Circuit diagram for Polarity test of CT using DC supply: Circuit diagram of ratio test of CT using AC supply: INSTRUMENT AND EQUIPMENT USED: 01 02 03 Sl. No Name of the Apparatus Quantity Type Marker s Name

PROCEDURE: Polarity test of PT using AC supply: 1) Connect the circuit as per circuit diagram and marked the each terminals of primary and secondary wingding input voltage at suitable value. Read the input voltage (V 1 ) and output voltage (V 2 ). 2) If the voltmeter connected between primary and secondary reads the sum of voltages of (V 1 + V 2 ). Then P 1 and S 1 are opposite polarity. 3) If the voltmeter connected between primary and secondary reads the difference of voltages of (V 1 V 2 ). Then P 1 and S 1 are same polarity. Ratio test of PT: 1) Connect the circuit as per circuit diagram. 2) Connect the PT primary to the output of variable voltage source. 3) Increase the input voltage and take input and output voltage reading at least 10 point over its operating range. 4) Find out the transformation ratio. Also find error from the given ratio of the transformer. Polarity test of CT using DC supply: 1) Connect the circuit as per circuit diagram and marked the each terminals of primary and secondary wingding. 2) Be sure the input voltage polarity to the input terminals and polarity of centre galvanometer connection in the output terminals. 3) Operate the push button for a fraction of time. Find the direction of deflection of the zero centre galvanometer. 4) If deflection is right hand side that means supply positive terminal and galvanometer positive terminal is same polarity. If deflection is left hand side that means supply positive terminal and galvanometer positive terminal is opposite polarity. 5) Repeat the whole experiments after reversing the source.

Ratio test of CT: 1) Connect the circuit as per circuit diagram. 2) Connect the CT primary to the output of variable current source. 3) Increase the input current and take input and output current reading at least 10 point over its operating range. 4) Find out the transformation ratio. Also find error from the given ratio of the transformer. 5) Be sure that at any condition CT secondary will not open during primary energies. OBSERVATION AND RESULT: Polarity test of PT: Input voltage (V 1 ) Output voltage(v 2 ) Voltmeter between primary and secondary Polarity according to marking Ratio test of PT: No of observation 01 02 03 Input voltage (V 1 ) Output voltage (V 2 ) Transformation Ratio (V 1 / V 2 ) Polarity test of CT: Supply DC polarity to the primary terminal according to marking Connected galvanometer to the secondary terminal marking Direction of deflection Polarity of terminals according to marking

Ratio test of CT: No of observation 01 02 03 Input current (I 1 ) Output current (I 2 ) Transformation Ratio (I 1 / I 2 ) CONCLUSION / DISCUSSION: Write your comments on the results obtained and discuss the discrepancy, if any. QUESTIONS: a. Why secondary of CT is not kept open? b. What do you know about ratio error & phase angle error?

EXPERIMENT NO: 05 TITLE: Run the Newton-Raphson load flow analysis program using ETAP (Electrical Transient Analyser Program) Power station. OBJECTIVE: To calculate the bus voltage, branch power factors, currents and power flows throughout the electrical system. [The program allows for swing, voltage regulated and unregulated power sources with multiple utility and generator connections]. THEORY: Newton-Raphson Method The Newton-Raphson Method formulates and solves iteratively the following load flow equation. Where P & Q are specified bus real power and reactive power vectors, m is match vectors between specified value and calculated value respectively; V and magnitude vectors and represents bus voltage angle in incremental form and J 1 through J 4 are called Jacobian matrices. The Newton-Raphson Method possesses a unique quadric convergence characteristics. It usually has a very fast convergence speed compare to other load flow calculation methods. It also has the advantage that the convergence criteria are specified to ensure convergence for bus real power and reactive power mismatches. This criteria gives direct control of the accuracy you want to specify for the load flow solution. The convergence criteria for the Newton- Raphson method are typically set to 0.001MW & MVAR. The Newton-Raphson Method is highly dependent on the bus voltage initial values. A careful solution of bus voltage initial values is strongly recommended. Before running load flow using the Newton-Raphson method, Power station

makes a few Gauss-Seidel iteration to establish a set of sound initial values for the bus voltage. The Newton-Raphson Method is recommended for use with any system as a first choice. SOFTWARE USED: ETAP power station 5.2 PROCEDURE: 1) Draw the circuit as per connection diagram. 2) Give input to all the elements. 3) Select Newton-Raphson method on study case tool bar. 4) Run the load flow program. 5) Now observe the result. 6) Take complete Report RESULT: CONCLUSION: QUESTIONS: a. If n is the no of buses and m is the no of PQ buses what will be the dimension of Jacobian Matrix? b. What is FDLF method? c. What are the advantages of FDLF method over N-R method?

EXPERIMENT NO: 06 TITLE: Run the Accelerated Gauss-Seidel Method load flow analysis program using ETAP (Electrical Transient Analyser Program) Power station. OBJECTIVE: To calculate the bus voltage, branch power factors, currents and power flows throughout the electrical system. [The program allows for swing, voltage regulated and unregulated power sources with multiple utility and generator connections]. THEORY: Accelerated Gauss-Seidel Method: The Accelerated Gauss-Seidel Method formulates and solves iteratively the following load flow equation. [P + jq] = [V T ][Y * BUS][V * ] Where P & Q are specified bus real power and reactive power vectors, V is the bus voltage vector, and Y BUS is the system admittance matrix. The accelerated Gauss-Seidel method has relatively lower requirement of the bus initial voltage values compared to the Newton Raphson and the fastdecoupled method. Instead of using bus real power and reactive power mismatch as convergence criteria, the accelerated Gauss-Seidel method checks bus voltage magnitude tolerance between two consecutive iterations to control the solution precision. The typical value for bus voltage magnitude precision is set to 0.000001 pu. The accelerated Gauss-Seidel method has slower convergence speed. When you apply appropriate acceleration factors, a significant increase the rate of convergence can be obtained. The range for the acceleration factor is between 1.2 typically set to 1.45. SOFTWARE USED: ETAP power station 5.2

PROCEDURE: 1. Draw the circuit as per connection diagram. 2. Give input to all the elements. 3. Select Accelerated Gauss-Seidel method on study case tool bar. 4. Run the load flow program. 5. Now observe the result. 6. Take complete Report RESULT: CONCLUSION: QUESTIONS: a. What is Acceleration factor? b. Compare between the Gauss-Seidel load flow method and the Newton Raphson Load flow method.