REQUIREMENTS FOR DIRECTIONAL LAMPS, LIGHT EMITTING DIODE LAMPS AND RELATED EQUIPMENT ACCORDING TO THE EC REGULATION 1194/2012

Similar documents
IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG

Diogen Lighting,Inc 14 Inverness Drive East,Ste.E-128 Englewood, CO T8L W BEST Test Service Shenzhen Co., Ltd.

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG





Reference No.: WTF13F R1N Page 2 of 13

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.

LM Test Report

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

LM Test Report

LM Test Report

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

TEST REPORT COMMISSION REGULATION (EU)

Reference No.: WTF15F N Page 2 of 20

RADIOCOMMUNICATIONS TESTING

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

IESNA LM-79: Measurement and Test Report for. Green Creative. Xinsen Science &Trade Park, Unit 327,839An'Yuan Road, Shanghai, China

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

TEST REPORT. ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA

LM Test Report

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

TEST REPORT. ASTM E648 Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

LM Test. for LED. Cabinet

Test Verification of Conformity

REVOLUTION LIGHTING TECHNOLOGIES INC

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

EMC VERIFICATION SUMMARY Report No.: SZHH

EESTOR INC. TEST REPORT

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

Dongguan Bai lida Optoelectronics Technology Co. Ltd. TEST REPORT

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD

VAC 60HZ A 120V; 0..18A 277V 40W PF ,000 LM 125 LM/W >82 <19. Arcata VDC 1.2A 120V 88% Edison

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

Test report number CRT-001b Project number CRT-001b

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

Eternal Shine Technology Co.,Ltd. EST

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

Report no GZU-001. Growatt 30000TL3-S, Growatt 30000TL3-SE. Max. input current: 34A/34A 38A/38A

LM Test Report. For SHENZHEN SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

Cat# LED Classic Large Wall-Pack

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Cat# LED High Bay

LM Test Report. For. Beyond LED Technology Parker Ct Stone Mountain, GA Epic Series LED Pole Light

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

71332 LED Dusk To Dawn (Area Light)

Cat# 71440A LED Classic Large Wall-Pack

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

Dimming: PWM/TIME/0-5V/0-10V. RoHS

Cat# 71146A 150W Trunion Mount

TEST REPORT. ASTM E648 Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

71352A QPL ID # PLT2P2L2UNWR. RoHS

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

LM Test Report

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

This is to attest that

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.

Report No.: HZ c

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Photometric Test Report

Transcription:

2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Telephone: (852) 2173 8888 Facsimile: (852) 2785 5487 www.intertek.com REQUIREMENTS FOR DIRECTIONAL LAMPS, LIGHT EMITTING DIODE LAMPS AND RELATED EQUIPMENT ACCORDING TO THE EC REGULATION 1194/2012 Implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for directional lamps, light emitting diode lamps and related equipment. APPLICANT, IDENTIFICATION OF THE TEST SAMPLE Applicant Applicant Address Type of appliance Intended use Brand name Type of Sample 1 Serial number Electrical data 3/F, 4th Building, Hangguang Park, Chuangye 4th Road, Zhangbei 2nd Village, Ailian Community, Longgang District, Shenzhen, China Dimmer Control Device SHYUSC EU P3 220 240V~, 50Hz Date Received 19 Jun 2017 Date Test Conducted 21 Jun 2017 to 23 Jun 2017 Issue Date 07 Jul 2017 Summary of test results These results are in complied with the stage 1 to 3 in ecodesign requirements of the EC regulation 1194/2012. Intertek s standard Terms and Conditions can be obtained at our website http://www.intertek.com/terms/. The test report only allows to be revised within the retention period unless further standard or the requirement was noticed This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. 2017 Intertek Page 1 of 7

STANDARD AND ENVIRONMENTAL CONDITION Test laboratory Address Standard applied Tested at Ambient temp. Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. EN62442 3 of EC 1194/2012 Annex VI of EC 874/2012 230 VAC / 50.0 Hz 25.0 C ±1ºC THD <3.0% Measuring device CCD Array Spectrometer Inventory number: EW 3115 65 inches Integrating Sphere unit Inventory number: EW 1335 AC Supply Digital Meter Digital Meter Calibrated lamp standard Inventory number: EW 3283 Inventory number: EW 3107 Inventory number: EW 2595 Inventory number: EW 3260 Set up and circuits used for electrical testing Refer to separate page (drawing, photo or the like) Page 2 of 7

MEASUREMENT CONDITIONS 1.1 No Load Measurement The power was measured at the dimmer was operated without load at 230V, 50Hz. 1.2 Standby Measurement The power was measured at the dimmer was operated with connecting the maximum load which is in OFF status at 230V, 50Hz. 1.3 Light Output Ratio When a dimming control device is switched on at its lowest control setting for which the operated lamps consume power, the operated lamps shall emit at least 1 % of their luminous flux at full load. 1.4 Efficiency of The Halogen Lamp Control Gear consumed by the load with connecting the control gear Efficiency consumed by the load without connecting the control gear Where power consumed by the maximum load connected with the control gear mean the output power of dimmer. And power consumed by the maximum load connected without the control gear mean the output power of the lamp without dimmer. 1.5 Test Condition parameters TEST VOLTAGE ±0.2 % During measurement TEST FREQUENCY ±0.5 %. TOTAL HARMONIC CONTENT OF THE TEST VOLTAGE 3%(up to and including the 13th harmonic) Page 3 of 7

TEST AND VERIFICATION RESULTS Lamp Efficacy of Ecodesign Requirements in EC Regulation 1194/2012, Stage 2 1.2a) No Load : Limit 1.0W Efficiency of halogen Lamp Control Gear: Limit 0,91 at 100% Load Lamp Efficacy of Ecodesign Requirements in EC Regulation 1194/2012, Stage 3 1.2b) No Load : Limit 0.5W (Stage 3) Standby ; Limit: 0.5W (Stage 3) Functionality Requirement for Equipment, Designed for Installation Between the Mains and the Lamps, Stage 2 2.3) When a dimming control device is switched on at its lowest control setting for which the operated lamps consume power, the operated lamps shall emit at least 1 % of their luminous flux at full load. 1.41% P Product Information for Equipment other than Luminaires, Designed for Installation Between the Mains and the Lamps, Stage 2 3.3) A Warning for equipment no compatibility with any of the energy saving lamps according to part 2.3 of this Annex. Showed in instruction manual P Product Information for Lamp Control Gear, Stage 2 3.4a) Indication that the product is intended to be used as a lamp control gear 3.4b) The information that the product may be operated in no load mode (If applicable) Page 4 of 7

APPENDIX TEST DATA SHEET 1. No load Model Sample Voltage Current 2. Standby (V) (ma) (W) 1 Model Sample Voltage Current (V) (ma) (W) 1 3. Light Output Ratio Maximum Light Output Model Sample Dimmer And Load Load Luminous Voltage Current Voltage Current Flux (V) (A) (W) Factor (V) (ma) (W) Factor (lm) EU P3 1/1 230.0 1.33 292.21 0.957 218.3 1.33 290.18 1.000 5851.92 Average 230.0 1.33 292.21 0.957 218.3 1.33 290.18 1.000 5851.92 Minimum Light Output Model Sample Dimmer And Load Load Luminous Voltage Current Voltage Current Flux (V) (ma) (W) Factor (V) (ma) (W) Factor (lm) EU P3 1/1 230.0 737.10 56.52 0.333 75.3 737.30 55.54 1.000 82.44 Average 230.0 737.10 56.52 0.333 75.3 737.30 55.54 1.000 82.44 Light Output Ratio Model Sample Maximum Minimum Light Output Light Output Light Output Ratio (lm) (lm) % EU P3 1/1 5851.92 82.44 1.41 Average 5851.92 82.44 1.41 Page 5 of 7

APPENDIX TEST DATA SHEET (Cont d) 4. Efficiency of the Halogen Lamp Control Gear measurement of the load connected with dimmer Model Sample Voltage Current (V) (ma) (W) Factor 1 measurement of the load connected without dimmer Model Sample Voltage Current (V) (ma) (W) Factor 1 Model Sample Efficiency 1 Remarks: 1. Measurements were conducted at voltage 230V, frequency 50Hz and a stable ambient temperature 25 C±1 C. 2. The load was a 300W filament lamp. Page 6 of 7

PHOTO OF THE APPLIANCE: THE RESULTS ONLY RELATE TO THE ITEM TESTED Tested by: Approved by: Chan Ho Chun, Reeve Lam Chi Keung Engineer Manager *************************************** End of Report *************************************** Page 7 of 7