OPERATIVE GUIDE V.E.S. VERTICAL ELECTRIC SURVEY

Similar documents
OPERATIVE GUIDE MULTIELECTRODE GEOELECTRICS

OPERATIVE GUIDE REFRACTION SEISMIC

Electrical Resistivity Imaging

Asset Protection Cathodic Protection Soil Resistivity Measurement. Work Instruction No.:

A COMPARISON OF ELECTRODE ARRAYS IN IP SURVEYING

Evaluation of Soil Resistivity Characteristics forsubstation Grounding: a Case Study of a University Campus in South-West Zone, Nigeria

The application of GPR for the modeling of ERT data and the evaluation of resolution for different electrode configurations

USER MANUAL Edition Rev.1 Copyright 2010 P.A.S.I. All Rights Reserved

Understanding Soil Resistivity Testing

Data Acquisition and Processing of a Distributed 3D Induced Polarisation Imaging system

Electromagnetic Induction

7. Consider the following common offset gather collected with GPR.

Results of GPR survey of AGH University of Science and Technology test site (Cracow neighborhood).

Understanding Seismic Amplitudes

Appendix III Graphs in the Introductory Physics Laboratory

Here the goal is to find the location of the ore body, and then evaluate its size and depth.

The use of high frequency transducers, MHz, allowing the resolution to target a few cm thick in the first half meter suspect.

Getting Started with Induced Polarization

Assessment of Step and Touch Voltages for Different Multilayer Soil Models of Complex Grounding Grid

Grounding and Lightning arrestors

GCM mapping Vildbjerg - HydroGeophysics Group - Aarhus University

Earth Sciences 089G Short Practical Assignment #4 Working in Three Dimensions

ALIGNMENT METHODS APPLIED TO THE LEP MAGNET MEASUREMENTS. J. Billan, G. Brun, K. N. Henrichsen, P. Legrand, 0. Pagano, P. Rohmig and L. Walckiers.

Page 21 GRAPHING OBJECTIVES:

Safety earthing. Sector Energy PTI NC. Copyright Siemens AG All rights reserved. Theodor Connor

Experiment G: Introduction to Graphical Representation of Data & the Use of Excel

SIMULATION OF GPR SCENARIOS USING FDTD

We 21P1 10 Spectral Time Domain IP - Factors Affecting Data Information Content and Applicability to Geological Characterization

HV Substation Earthing Design for Mines

Seismic Reflection Method

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

McArdle, N.J. 1, Ackers M. 2, Paton, G ffa 2 - Noreco. Introduction.

BUREAU OF INDIAN STANDARDS. Draft Indian Standard SURFACE GEOPHYSICAL SURVEYS FOR HYDROGEOLOGICAL STUDIES

2.75-D ERT: ZIGZAG ELECTRODE ACQUISITION STRATEGY TO IMPROVE 2-D PROFILES. Abstract

Following are the geometrical elements of the aerial photographs:

Amplitude balancing for AVO analysis

Free vibration of cantilever beam FREE VIBRATION OF CANTILEVER BEAM PROCEDURE

User Guide. Life detection with. RescueRadar

JUNIOR CERTIFICATE 2009 MARKING SCHEME TECHNICAL GRAPHICS HIGHER LEVEL

Laboratory 2: Graphing

GPR SURVEY METHOD. Ground probing radar

DIGITAL RESISTANCE METER

High Voltage Pylon earth Measurements. Tycom (Pty) Ltd Frank Barnes Comtest (Pty) Ltd Presented by Gavin van Rooy

Simulation and Analysis of Lightning on 345-kV Arrester Platform Ground-Leading Line Models

from ocean to cloud LAND CABLE INTERFERENCE MODEL AND CABLE CROSSINGS WITH POWER INTERCONNECTS

Detection of Obscured Targets

ARCHAEOLOGICAL GEOPHYSICS: SENSOR SELECTION AND SITE SUITABILITY

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD GROUNDING RESISTANCE MEASUREMENTS AND IMPROVEMENT

Chapter 1: DC circuit basics

There are a wide variety of ground resistance testers available on the

Industrial and Commercial Power Systems Topic 7 EARTHING

STANDARD OPERATING PROCEDURES SOP:: 2057 PAGE: 1 of 6 REV: 0.0 DATE: 07/11/03

ENVI.2030L Topographic Maps and Profiles

Borehole Seismic Processing Summary Checkshot Vertical Seismic Profile

GeoRadar Division. GPR for Archeology and Cultural Heritage. GeoRadar Division. GPR Configuration for Archeology and Cultural Heritage Application

PRORADAR X1PRO USER MANUAL

SPNA 2.3. SEG/Houston 2005 Annual Meeting 2177

Ohm's Law and DC Circuits

Applied Methods MASW Method

Tx II Transmitter 3600 W Instruction Manual

General Consideration about Current Distribution and Potential Attenuation Based on Storage Tank Bottom Modeling Study

Sometimes for grounded antennas is used a usual horizontal dipole antenna located straight over the ground. Page-16

Math + 4 (Red) SEMESTER 1. { Pg. 1 } Unit 1: Whole Number Sense. Unit 2: Whole Number Operations. Unit 3: Applications of Operations

Bearing Capacity of Strip Footings on Two-layer Clay Soil by Finite Element Method

10 GRAPHING LINEAR EQUATIONS

Attendee Announcements

Scaled Laboratory Experiments of Shallow Water Acoustic Propagation

Sw earth Dw Direct wave GRw Ground reflected wave Sw Surface wave

TABLETOP MODELS FOR ELECTRICAL AND ELECTROMAGNETIC GEOPHYSICS

HELICOPTER-BORNE GEOPHYSICAL SURVEY SYSTEMS

Pitfalls in GPR Data Interpretation: Differentiating Stratigraphy and Buried Objects from Periodic Antenna and Target Effects

24 channels seismograph, 24 bit real resolution Channels from 12 to 72 Embedded Pc - color touch screen monitor and rechargeable battery.

Chapter 1: DC circuit basics

Instruction Manual for Digital Grounding Resistance Meter

Ground Parameters For Hams Do we have a problem and can we do something about it? Rudy Severns N6LF

NSCAS - Math Table of Specifications

Understand the importance of Ground Resistance Testing & much more! (800) (508)

Archaeo-Geophysical Associates, LLC

Safety Issues Caused by High Earth Resistance and Identifying Them Using Instruments

Stretched Wire Test Setup 1)

California 1 st Grade Standards / Excel Math Correlation by Lesson Number

GROUND TESTERS For all of your Ground Testing needs...

Prototype Software-based Receiver for Remote Sensing using Reflected GPS Signals. Dinesh Manandhar The University of Tokyo

High Voltage Pylon Earth Measurements

Determining the Dynamic Characteristics of a Process

Antenna simulations Part 2

A CAS Forum Activity Report Looking at Hair Tension as a Design Parameter for Violin Bows

Considerations about Radiated Emission Tests in Anechoic Chambers that do not fulfil the NSA Requirements

ANALOG RESISTANCE METER USER S MANUAL

Contents. Notes on the use of this publication

INTRODUCTION CURRENT CARRYING CAPACITY OF ELECTRIC CABLE

Manual for the ArborElectro impedance tomograph

Technology of Adaptive Vibroseis for Wide Spectrum Prospecting

Earth/ground measurement guide. Earth/ground resistance and soil resistivity testers

Year at a Glance Pacing Guide Art- Grade Kindergarten

New designs from Africa

Ohm s Law and Electrical Circuits

Feasibility study of the marine electromagnetic remote sensing (MEMRS) method for nearshore

Induced Polarization Survey Over the Rand Property Teck Township, Ontario

ANALOG RESISTANCE METER

Transcription:

OPERATIVE GUIDE V.E.S. VERTICAL ELECTRIC SURVEY 1

Quadrupole geoelectric procedure (V.E.S.) Generals V.E.S. (Vertical Electric Survey) geoelectric prospection method consists in investigating a specific territory resistivity variation with depth. It belongs to most ancient indirect geognostic surveys, non-invasive, which allows to analyze long soil profiles at great depth, with low costs and without disturbing existing buildings or underground water flowing. V.E.S. (Vertical Electric Survey) technique includes a series of resistivity determinations performed with increasing distance between current electrodes (A-B) and potential electrodes (M-N), according to 4 electrodes array outlined as follows. Through two external electrodes A and B a continuous current supplied by dry batteries or a generator is input into the ground; through central electrodes M and N potential difference generated into the ground when current flow between A and B is measured. Potential difference measures (pd) and current intensity (I) are performer with precision instruments, equipped with spontaneous potentials canceler existing into the ground. From these measures apparent resistivity of the soil is detected (R) according to formula: where K indicates array constant geometry. Array Schlumberger K= (AMxAN/MN) Array Wenner K= 2MN R = K ddp/i We talk about apparent resistivity because a whole rocky volume is investigated. Subsoil investigated volume is related (indicatively) at a parallelepiped of L =3(AB/2) length, l =AB/2 thickness and H=AB/4 depth. ELECTRODE DISPOSITION Wenner quadrupole (constant spacing) K factor computing facility Schlumberger quadrupole (MN measure electrodes distance small compared to AB) advantage is increasing of depth of investigation. Tripole or pole-dipole (is an asymmetric quadrupole with a current electrode very distant from the other three). Advantage of this device is possibility to reach high depths of investigation with arrays relatively reduced and high sensitivity to lateral disturbs. 2

To extend resistivity measures at layers more and more deep, distance between electrodes A-B and M-N is increased; in this way, current lines cross subsoil layers more and more in depth. Transferring apparent resistivity values on a bilogarithmic diagram, apparent resistivity curves are generated in which values AB/2 on abscissa are expressed in meters, while those of resistivity, on ordinate axis, are expressed in ohm*meter. From so obtained resistivity curves it is possible to detect real resistivity values and layers thickness of different resistivity, with the help of a mathematic model. V.E.S. single interpretations will be eventually visualized in a graphic in the form of geoelectric profiles which allow to visualize elaborated sections underlying correlations with available stratigraphical data. Moreover, thematic charts at level curves can be elaborated to underline the trend of surfaces and/or thickness of particularly interesting units, such as water layers or water tight layers. Acquisition mode Given that electrodes must be moved manually between one recording and the other, it is recommended to first set instrument for the analysis so as to avoid possible problems 3

during the job. Operating steps are described below. At instrument starting, after few seconds necessary for operating system uploading and peripherals starting, Activate section VERTICAL ELECTRIC SURVEY and upload a configuration table (file with.sev extension) which, as shown in picture, includes semi-distances between current electrodes (A-B) and those between potential electrodes (M-N). Related K geometric factor is automatically calculated. Electric current (I) is applied to electrodes A and B and potential (V) is measured between electrodes M and N. Resistivity ρ is calculated with the formula: 4

File.sev in table form includes semi-distances between current electrodes A-B and those between potential electrodes (M-N). Before starting with single measure it is recommended to check configuration window and parameters set on instrument according to the type of investigation. Place electrodes at fixed distance (AB/2 and MN/2 indicated in the first line of the table) which is for the first measure 0.5 m between M,N and P and 2 m between A, B and P, then connect electrodes to instrument through the reels. 5

Now we are ready to perform measurement. Electrodes must be in line, along an arbitrary linear direction, possibly preferring the direction of minimum slope. Measures refer to the vertical crossing the symmetry center P of electrodes, which must remain the same during all measures set. Electrodes must be in line long a linear direction, preferring directions with minimum slopes so as to reduce errors caused by rough topography. Generally speaking current density increases in dumps and decreases in correspondence of hills. For quadrupole measures it is recommended to plan array in order to easily position cables while proceeding with measurements. In particular if user wants to perform survey with arrays of even hundreds of meter in length. It is recommended that measures are related to the vertical passing for symmetry centre of electrodes. Once visualized table with distances, it is possible to start measure set by fixing electrodes at predetermined distance. If the box "measure only spontaneous potentials" is selected, no current will be generated and only spontaneous potentials values will be registered, measured for each electrode configuration. 6

If user has previous information about investigation site, such as presence of a lithology characterized by relatively high resistivity, it could be necessary to increase input current intensity. So it is possible to proceed with all single measures moving every time quadrupole at different distances from central point as shown in table AB/2 and MN/2. Here is a sum up of all operations to perform a measure once fixed a reference point P on the ground and a direction d: - select corresponding line in table; - connect electrodes through cable reels according to provided scheme; - place electrodes respectively at distances AB/2 and MN/2 indicated in line, selected according to P point and along d direction. For example, for the measure selected in picture 9, electrodes M and N must be placed each at 0.5 m from P and A and B each at 2 m from P. - press the button Single measure and wait for the measure to be completed. Pressing the button 'Start sequence' instrument will perform current measure and will stop waiting for confirmation that electrodes displacement is done. Therefore it will proceed with immediately following measure and so on until the end. To ensure user and all operators safety, before moving electrodes, always pay attention to instrument being in rest and with high voltage generator deactivated. At measures conclusion, it is possible to save data in.tsv and also in.dat format. File saved in the last format can be used directly for processing with freeware program RES1D, downloadable at link: http://www.geoelectrical.com/r1d.zip which includes also instructions for its use. It is possible to perform measures with spacing different from that written in the example table Schlumberger.sev. For this aim it is necessary to prepare a different table. Table consists simply in a list of values couples, which, as indicated in heading, represent respectively semi-distances between current and potential electrodes. Computing of K geometric factor, necessary to determine apparent resistivity, will be automatically calculated from that distances when performing measures. User shall pay attention to place 4 electrodes in proper way, according to prospection scheme of Schlumberger. Same table can be also used for a quadrupolar array of Wenner type. For filling table on PC it is possible to use a text editor, such as Notepad, or a computing paper such as Microsoft Excel. Below there is procedure, in which at each line corresponds a measure. 2.0;0.5 2.0,0.5 4.0;0.5 4.0,0.5 6.0;0.5 or: 6.0;0.5 7

10.0;0.5 10.0;0.5 10.0;1.0 10.0;1.0 Save file as text document with.sev extension (for a type). With Notepad is necessary to specify All files in the box Save as:, to avoid that.txt extension will be automatically added to file name. V.E.S. interpretation Without added information about lithology or piezometric level, interpretation is actually inaccurate. Knowledge through geognostic surveys on site will help improving resolution of final model. INTERPRETATION BUILDING A GEOLOGICAL MODEL DETERMINATION OF THEORETICAL RESISTIVITY CURVES COMPARISON WITH EXPERIMENTAL DATA 8

Resistivity diagrams represents tool resistivity-depth based on subsoil lithologic situation. In quantitative interpretation, inverse process must be done, that is to detect soil model in terms of thickness and layers resistivity according to resistivity trend with depth. This procedure is made through a computing program that applies a proper mathematics model. Elaboration softwares provide immediately computed resistivity curve (based on a model which has been entered) overlapping that measured on ground, allowing to evaluate correspondence between two curves. Through some tools on correspondence between interpretative solutions (properly varying thickness and resistivity of a layer, its electric response does not relevantly change), it is possible to elaborate a physical model of the subsoil which takes into consideration interpretations of all V.E.S., compared one another for each area. Curves elaborated and detected on ground can be transferred on a single graphic in which it is possible to visually check their correspondence. Interpretation of single V.E.S. is done with the hypothesis that subsoil layers, below station point, are homogeneous, horizontal and with plane-parallel separation surfaces. Typical of electric prospection, there is a possibility of error in determining resistivity values and thickness of each single layer not lower than +/- 20-30%, referred mainly to limits from above-mentioned equivalence principles. 9

SIZE RANGE OF WATER AND ROCKS RESISTIVITY (from Astier, 1971 mod). 1. Good conductors(ρ < 10 7 Ωm); 2. Medium conductors (1< ρ < 10 7 Ωm); 3. Bad conductors or insulators (ρ >10 7 Ωm); Sea water <0,2 Water with 20% of salt 3*10-2 Pure water 102 3*103 Limestones and dolomites 100 5000 Sandstones 60 104 Clays (fresh water) 10 120 Clays (salt water) 1 10 Marls 2 50 Sand (from wet to dry) 100 1000 Granites 300 104 and more Basalts 10 105 Quartzites 2*104 and more Pyrite 10-4 10 Galena 10-2 300 Graphite 10-3 1 Bauxite 200 6000 10

Below there are results of vertical electric survey in which it is possible to observe how resistivity curve changes according to present stratigraphic attitude (from course Applied General Geophysics of Roma Tre AA12/13 - Antonio Meloni). VES for a 2 layers case 11

VES for a 3 layers case 12

VES for a 4 layers case 13

14