Instruction Manual. LD/LA Level Transmitter. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax

Similar documents
Instruction Manual. HB Series Mini Level Sensor

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Non-Submersible Industrial Pressure Transducer

TRANSDUCER IN-LINE AMPLIFIER

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

670K9 SORtrax Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter

Ricochet Alphasonic Level Transmitter Model LA15 Owner s Manual

KING-GAGE KING. ES2 Liquid Level Transmitter. Installation and Operation Instructions ma Liquid Level Transmitter EX-1834

Kotron Sentinel Model 804 RF Level Transmitter

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

KING-GAGE. D/P Transmitter 4-20 ma Pressure Transmitter ma Pressure Transmitter. Operation/Calibration Manual

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

Echotel Model 961 Ultrasonic Level Switches for Hygienic Applications

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches

KING-GAGE ES2. Installation and Operation Instructions Manual. Electronic Liquid Level Transmitter. ESR Serial No. Versions and Slimline Versions

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

2-wire level transmitter

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

TRANSDUCER IN-LINE AMPLIFIER

Global Water Instrumentation, Inc.

HUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER

LT3000 ULTRASONIC LEVEL TRANSMITTER

LPU-2127 User Manual

American Power Design, Inc.

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

Materials (other materials see WIKA diaphragm seal program) Model S-10

MiniMe Two-Wire Ultrasonic Level Transmitter Model LU11/12/13/14 Owner s Manual

MiniMe 2-Wire Ultrasonic Level Transmitter Model LU12/LU13/LU14 Owner s Manual

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

Broadband Current Probe Series Operation Manual

LUDLUM MODEL 182 RADON FLASK COUNTER. June 2011 Serial Number PR and Succeeding Serial Numbers

EchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure

Global Water Instrumentation, Inc.

KING-GAGE. D/P Transmitter 4 20 ma Pressure Transmitter ma Pressure Transmitter. Operation/Calibration Manual

Programmable K-Factor Scaler B and Programming Software Kit B

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Kotron Model 82 CE RF Level Transmitter

Model TL Linearized Platinum Resistance Thermometer Temperature Transmitter Instruction Manual

Table of Contents. Safety Notices

80i-600A AC Current Probe

Worldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

MINCO PRODUCTS, INC Commerce Lane, Minneapolis, Minnesota U.S.A. Telephone: (763) FAX: (763)

Broadband Current Probe Series Operation Manual

M2/M2A AC-DC Power Supply Operator s Manual

User s Guide HX94B SERIES. Temperature/Relative Humidity Transmitter. Shop online at omega.com SM

KPS Turbidity Meter User s Manual

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

K-FACTOR SCALER B & B

Princo MagneLevel Model LML

Copyright 2014 by Minarik Drives

MODEL 174 LIQUID LEVEL TRANSMITTER

Loop Monitor Instruction Manual

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

OPERATING INSTRUCTIONS

INSTRUCTION MANUAL INF Fax: (503)

Meriam Model M ma Loop Calibrator Operating Instructions

RK PPM Hexane Transmitter Operator s Manual

USER S MANUAL PROCESS CONTROL MODULE PCM3

RK Hydrogen Transmitter Operator s Manual

User s Guide HX71 SERIES. RH Probe/Transmitter. Shop online at omega.com SM. RoHS 2 Compliant

Radio Remote Controls Manual K Series

VARIABLE FREQUENCY DRIVE SPECIFICATION

User s Guide TX94A. Ultra-Miniature Temperature Transmitters. Shop online at omega.com

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

600A Clamp Meters w/tightsight Display

Bulk Current Injection Probe Test Procedure

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Advanced Test Equipment Rentals ATEC (2832)

ULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

PIN/PINLESS DEEP SENSING MOISTURE METER WITH SPHERICAL SENSOR AND REMOTE PROBE

M5800 Pressure Transducer with Rotatable Display

U5300 Industrial Pressure Transducer

RHS SERIES RH Set Point Controller/Probe

TDS-535 Tuned Dipole Set Operation Manual

KMS-2 Exia Magnetostrictive Level Transmitter

M E E T I N S T R U M E N T A T I E MAS ma Soil Moisture Sensor. User Manual. Version 4

Current Probe Fixture Instruction Manual

VOLUME CONTROL CONNECTION TERMINAL

OVEN INDUSTRIES, INC. Model 5C7-362

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

Model A. DIN Rail Strain Gage Conditioner. Installation and Operating Manual

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

AIU-2 Installation Manual

RLT Rainfall Transmitter Instruction Manual

Instruction Manual T-800 Series Current Transmitter. Model T-800L Model T-800LT Model T-800TT

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

Fireye. NEXUS FX04 and FX04-1 Servo Motor Installation DESCRIPTION SAFETY INFORMATION. FX04-1 Shown

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

HLC-1000 High-limit Humidity Control

HT2 Humidity Transmitter HT2 Humidity and Temperature Transmitter Installation and Operating Instructions

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Echotel Model 910 Ultrasonic Level Switch

Model 113 Scintillation Preamplifier Operating and Service Manual

Transcription:

Instruction Manual Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY 12072 1-800-833-0081 Fax 518-922-8997 www.andinst.com Instrument Model Number Instrument Serial Number LD/LA Level Transmitter Form Number AIC2023 November 2000 Revised: March 2009 Supersedes: July 2005

PAGE 2 Table of Contents Section 1 - General Page 1.1 INTRODUCTION 3 1.2 SPECIFICATIONS 3 1.3 DESCRIPTION 4 Section 2 - Installation 2.1 MOUNTING 5 2.2 ELECTRICAL WIRING 5 2.3 TRANSMITTER ELECTRONIC "ZERO" CALIBRATION 7 2.4 CALIBRATION VERIFICATION - UTILIZING ON-BOARD SETUP 8 2.5 CALIBRATION VERIFICATION - UTILIZING EXTERNAL PRESSURE SOURCE 9 2.6 CALIBRATION - UTILIZING ON-BOARD SETUP 11 2.7 CALIBRATION - UTILIZING EXTERNAL PRESSURE SOURCE 13 2.8 CONTROLLER TUNING 15 Section 3 - Maintenance and Troubleshooting 3.1 GENERAL 16 3.2 CALIBRATION CHECKS 16 3.3 VENT SYSTEM 16 3.4 TROUBLESHOOTING 17 Appendix A - Warranty and Return 18 FIGURES Figure 1-1 Dimensional Drawing 4 Figure 2-1 Typical Application View 5 Figure 2-2 Required Supply Voltages 6 Figure 2-3 Transmitter Loop Diagram 6 Figure 2-4 Zero Calibration Procedure 7 Figure 2-5 Current Cal Verification Hookup 8 Figure 2-6 Pressure Pump 9 Figure 2-7 Pressure Cal Verification Hookup 10 Figure 2-8 Field Cal Hookup 12 Figure 2-9 Pressure Pump Hookup 13 Figure 2-10 Pressure Cal Hookup 14

PAGE 3 Section 1 General 1.1 INTRODUCTION The Anderson LD/LA standard and pharmaceutical series level transmitters are unique devices designed for level control applications where pressure based technology provides the best overall solution, but where bottom access for the sensor is not available or preferable. These sensors are designed to be mounted on the top of the vessel with the extension tube positioning the sensing diaphragm near the bottom of the tank. Common applications include rotary filler bowls, surge tanks and small processing storage vessels where bottom access is impractical. With no moving parts, no air required, and wide compensated temperature range the LD/LA provides accuracy and repeatability in applications where other sensing technologies have been proven unreliable. 1.2 SPECIFICATIONS Performance Upper Range Limit (URL) Minimum Span: Over-Range Capacity: Accuracy: Repeatability: Stability: Compensated Temp. Range: (process) Compensated Temp. Range: (ambient) Effect of Process/Ambient 72" water column (w.c.) 30" w.c. 2.5 times the URL (180" w.c.) ± 0.75% of URL (± 0.5" w.c.) within ±0.3% of URL (± 0.2" w.c.) Within published specification for one (1) year minimum 30 F to 220 F (-1 C to 104 C) 30 F to 120 F (-1 C to 49 C) Temperature Change: ± 0.40% of URL per 10 F Humidity: 0-100% RH, Condensing Response Time: Power Signal Output: Loop Power required: Effect of Voltage Change: Load Impedance: Cable Recommended: Materials/Construction Housing /Wiring Head: Wetted Parts: Surface Finish (LD): Surface Finish (LA - Pharm.) Housing Rating: 526 msec 4-20mA dc 12-40 Vdc ± 0.05% of URL per 30 volts 1550 Ohms at 40 VDC 18-24 AWG,.169" to.209" diameter, stranded, 2 conductor with ground, shielded and PVC coated for use with seal-tight wire grommet 304 stainless steel 316L stainless steel Ra=25 microinches or better (wettedparts) Ra=15 microinches or better (wetted parts) NEMA 4X, IP-65 Agency Approvals Electronic "Noise" Designed to meet IEC 801-2, -3 and -4, Immunity: Level 3, CE Compliant Sanitary Standards: Complies with all applicable provisions of 3-A Sanitary Standards (74-00). Hazardous Locations: For LA only: UL, Intrinsically safe for use in CLass 1, Div. 1 Groups A-D. Warranty: All units are covered by a two (2) year warranty against defects in material and workmanship when installed and maintained according to the instruction manual provided.

PAGE 4 FIGURE 1-1 "LD/LA" DIMENSIONAL DRAWING See Matrix for Available Lengths 3-17/64 2.44 1-1/4 Dia. 2-3/4 Dia. 3-19/64 Dia. 2 Tri-Clamp 1/2 NPT Liquid Tight Connector 1.3 DESCRIPTION The LD/LA transmitter has been designed for measuring liquid level in control applications where a top-mount sensor is preferable or required for optimum performance. Typical applications include rotating filler bowls, surge tanks, or other atmospheric vessels where the dipstick design makes mounting and wiring simpler than a bottom mount sensor or other technology. The LD/LA outputs a standard 4-20mA dc signal for direct connection with a simple controller or indicator, or to a PLC. Units are calibrated at 0-30 w.c. for all lengths between 15 and 30. For longer lengths, units are calibrated to match the probe length up to the maximum of 72. Correction for product specific gravity different than water can be made at the factory, or in the field using the unique push button field calibration feature. Temperature compensation provides a usable range of up to 220 deg F and is designed to quickly correct for temperature shocks common in the intended applications. The LD/LA can be left in place for CIP and sterilization to protect against handling damage. The standard fitting on the LD/LA is a 2 tri-clamp and all wettable surfaces are constructed of 316 L stainless steel.

PAGE 5 Section 2 - Installation 2.1 MOUNTING The transmitter is designed to be mounted on the process vessel. Connection is secured via 2" Tri Clamp - gasket to be customer supplied. A typical application is as follows: FIGURE 2-1 TYPICAL APPLICATION VIEW PID LOOP CONTROLLER ELE CTRICAL WIRING CONTROL PANEL 4-20mA OUTPUT TO CONTROL VALVE (o r I/P) ELECTRO NIC SENSOR INSIDE VIEW FILLER BOWL 2.2 ELECTRICAL WIRING 2.2.1 Signal Cable Anderson recommends the use of 18-24 AWG, 4 conductor cable. In addition, it should be foil shielded with a continuous drain wire (If Factory supplied, Belden #9534 or equivalent). Although only two conductors and the drain wire are utilized, cable as specified above will retain its roundness when inserted into the seal-tight grommet. This will prevent moisture from entering the conduit housing of the transmitter. The drain (ground) wire should be attached to ground at only the receiver end. Be sure that this wire is cut back far enough so as not to make connection with any stainless steel inside the conduit head of the sensor. Installation as described will prevent induced ground loop currents from flowing through the drain wire causing errors in the ma signal. WARNING: To prevent signal interference, do not run signal cable closer than 12" to AC wiring, or if you must, cross it at a 90 angle. NOTE: If using customer supplied cable, be sure it is.109" -.209 O.D.. The use of larger diameter cable will make entry of the cable into the conduit housing difficult, while the use of smaller diameter cable may allow moisture to enter the transmitter. 2.2.2 Transmitter Power and Wiring The model LD Level Transmitter requires 12-40 VDC for proper operation. If below 24 VDC, a regulated supply is recommended. The total loop resistive load (signal wire, signal receiver, optional display, but not including transmitter) must not exceed the value given in Figure 2-3 corresponding to the voltage of the DC power supply used. Allow 23.3 ohms per 1000 feet for each conductor of 24 AWG sized wire (the smaller the AWG gauge, the larger the wire cross section).

PAGE 6 FIGURE 2-2 REQUIRED SUPPLY VOLTAGES MAXIMUM LOOP RESISTANCE (OHMS) (WIRE PLUS RECEIVER) 1400 1200 900 600 300 0 OPERATING RANGE 9 12 18 24 30 36 40 POWER SUPPLY VOLTAGE (VDC) It is recommended that the leads be stripped and tinned to provide for optimum signal connections. Wire to the integral terminal block in the transmitter conduit heads as illustrated in Figure 2-3. FIGURE 2-3 TRANSMITTER LOOP DIAGRAM HOOK METER TO TESTPOINTS FOR CALIBRATION M ETE R MODE SET T O DC MILLIAMP BLACK M ETER LEAD (T EST-) RED METER LEAD (TEST+) IF FACTORY SUPPLIED CABLE BELDEN #: 9534 (GREEN & WHITE NOT USED) TE ST- TE ST+ LOOP+ LOOP- LOOP - (BLACK) + SIGNA L RECEIV ER - 12-40 VDC POWER SUPPLY - + SHIELD GROUND (ONE POINT ONLY) LOOP + (RED) WIRE RESISTANCE

PAGE 7 2.3 TRANSMITTER ELECTRONIC "ZERO" CALIBRATION Upon installation of a new Factory Calibrated unit, and as part of routine maintenance, a Zero calibration adjustment must be performed. The transmitter ZERO, (signal output with no pressure applied to the diaphragm), is 4.00 ma. Although the calibration may be performed without additional tools, testpoints have been provided for monitoring the ma output signal from the transmitter. For maximum accuracy we recommend performing a sensor zero about three (3) weeks after initial installation, or following several heat/cool cleaning cycles. See Figure 2-4, Zero Calibration Procedure, for the location of the Zero switch. Depressing for 5-8 seconds automatically "zeros" the output. CAUTION: Field wiring MUST be complete loop power (12-40 VDC) applied Transmitter MUST be installed in vessel Verify NO product contact to diaphragm Vessel MUST be vented to atmosphere DO NOT depress SPAN switch MODE switch set to RUN MODE Once Zero calibration has been performed, sensor output will return to 4.00 ma. This is the proper output to signify an empty vessel ZERO calibration is complete. NOTE: No adjustment to the SPAN is necessary. ZERO and SPAN settings are noninteractive, having no effect on each other. FIGURE 2-4 ZERO CALIBRATION PROCEDURE NOTE: RECEIVER AND METER CONNECTIONS OMITTED FOR CLARITY REFER TO FIGURE 2-3 FOR HOOKUP SHOWN WITH CAP REMOVED DEPRESS ZERO/- SWITCH TO INITIATE ZERO CALIBRATION HOLD FOR 5-8 SECONDS TO COMPLETE ZERO CALIBRATION MODE SWITCH SET TO RUN MODE

PAGE 8 2.4 CALIBRATION VERIFICATION - UTILIZING ON-BOARD SETUP Utilizing a digital multimeter attached to the on-board testpoints, the LD/LA transmitter may be switched to an alternate output mode where the signal viewed on the meter is proportional to the current calibration range of the transmitter. Hookup is as follows: FIGURE 2-5 CURRENT CAL VERIFICATION HOOKUP HOOK METER TO TESTPOINTS FOR CALIBRATION METER MODE SET TO DC MILLIAMP DC ma BLACK METER LEAD (TEST-) RED METER LEAD (TEST+) Set to CURRENT CAL TEST- TEST+ LOOP+ LOOP- Note: Proper loop wiring must be established, not shown for clarity As shown, set operating switch to CURRENT CAL position. The signal displayed on the meter at this point is directly proportional to the current SPAN setting of the sensor. Using the following procedure, this value can be converted to the Inches of Water Column" calibration value: Perform calculation to determine current inches of Water Column calibration [[Meter Reading 4.00] 16] x 145 = Current Cal in "w.c. Once calibration has been determined, move switch back to RUN position to continue operation If value determined matches value in model number, unit is properly calibrated If value does not match value in model number, sensor calibration has been altered since unit left the factory see sections that follow for proper re-calibration procedures

PAGE 9 2.5 CALIBRATION VERIFICATION - UTILIZING EXTERNAL PRESSURE SOURCE If available, an external pressure calibrator may be used to determine the current calibration of a sensor. Test procedure is as follows: FIGURE 2-6 PRESSURE PUMP HOOKUP Digital Pressure Calibrator (Suggested Unit) Crystal Engineering Phone: 800-444-1850 Pressure Pump Model: 212-030PSI-G-HR Snap fit Calibration Adapter #73198-A3

PAGE 10 FIGURE 2-7 PRESSURE CAL VERIFICATION HOOKUP HOOK METER TO TESTPOINTS FOR CALIBRATION METER MODE SET TO DC MILLIAMP DC ma BLACK METER LEAD (TEST-) RED METER LEAD (TEST+) Set to RUN MODE TEST- TEST+ LOOP+ LOOP- Note: Proper loop wiring must be established, not shown for clarity 1. Remove sensor from vessel if already installed leave loop wiring attached 2. Provide loop power to sensor if performing a bench test 3. Attach snap fit calibration adapter to sensor fitting (Available from Anderson) 4. Sensor MUST remain stationary, with no movement 5. Perform ZERO calibration as described in this manual 6. Set pressure calibrator to proper range 7. Set multimeter to 4-20 ma DC scale, make connections at TEST + and TEST - testpoints 8. Using pressure pump, increase pressure until 20.00 ma is seen on the multimeter 9. Read Water Column from Pressure Calibrator this is current sensor calibration 10. If value determined matches value etched on side of sensor, calibration ok 11. If value does not match value in model number, sensor calibration has been altered since unit left the factory see sections that follow for proper re-calibration procedures

PAGE 11 2.6 CALIBRATION - UTILIZING ON-BOARD SETUP LD/LA transmitters utilize on-board "Setup" circuitry to perform maintenance and calibration. With these tools, in addition to a digital multimeter, it is possible to perform a field calibration / re-calibration of the output range. Note: Use caution if altering factory calibration no record will exist at Anderson pertaining to changes Calibration MUST remain within range parameters of unit be sure to refer to tables provided Loop power MUST be supplied to sensor Tools Required: Digital Multimeter Calculator NOTE: When re-calibrating a unit, you must remain within unit FULL OPERATING RANGE (0-72" w.c.). 1. Determine Desired Calibration, in Inches of Water Column ( WC) Example: Height Above Sensor In Inches (32") x Specific Gravity of Product (1.032) = 33.0"WC 2. Determine Proportional Cal Value for calibration using the following formula: [[[STEP 1 VALUE 145] x 16 ] + 4.00] = New Proportional Cal Value 3. Perform meter hookup as shown in the following figure Set MODE SWITCH to FIELD CAL position

PAGE 12 FIGURE 2-8 FIELD CAL HOOKUP HOOK METER TO TESTPOINTS FOR CALIBRATION METER MODE SET TO DC MILLIAMP DC ma RED METER LEAD (TEST+) BLACK METER LEAD (TEST-) Set to FIELD CAL TEST- TEST+ LOOP+ LOOP- Note: Proper loop wiring must be established, not shown for clarity 4. Meter output will automatically move to 19.99 sensor is waiting for entry of new calibration range 5. SPAN switch secondary function is +, and the ZERO switch secondary function is - 6. Using these two switches, raise or lower the value currently displayed on the meter until the value determined in step three (3) has been reached 7. Once the proper value has been reached, simultaneously depress BOTH the SPAN/+ and the ZERO/- switches for one (1) second this will lock in new sensor calibration 8. Calibration complete - mode switch set to "RUN MODE" position - place unit back into vessel - perform "ZERO" calibration

PAGE 13 2.7 CALIBRATION - UTILIZING EXTERNAL PRESSURE SOURCE If available, an External Pressure Calibrator may be used to perform a field calibration / recalibration of the range on the LD/LA Series Transmitter. Note: Use caution if altering factory calibration no record will exist at Anderson pertaining to changes Calibration MUST remain within range parameters of unit be sure to refer to tables provided Loop power MUST be supplied to sensor Tools Required: Pressure Calibrator (Equivalent to unit as described) Digital Multimeter 1. Determine that the desired range is within Full Operating Range of sensor (72" w.c.) 2. Perform hookup of pressure calibrator as shown in the following figure orient sensor in a location where easy access may be made to the internal setup switches 3. Perform hookup of Multimeter as shown in the figure on the following page: FIGURE 2-9 PRESSURE PUMP HOOKUP Digital Pressure Calibrator (Suggested Unit) Crystal Engineering Phone: 800-444-1850 Pressure Pump Model: 212-030PSI-G-HR Snap fit Calibration Adapter #73198-A3

PAGE 14 FIGURE 2-10 PRESSURE CAL HOOKUP HOOK METER TO TESTPOINTS FOR CALIBRATION METER MODE SET TO DC MILLIAMP DC ma BLACK METER LEAD (TEST-) RED METER LEAD (TEST+) Set to RUN MODE TEST- TEST+ LOOP+ LOOP- Note: Proper loop wiring must be established, not shown for clarity 4. Sensor MUST remain stationary, with no movement 5. Perform ZERO calibration depress ZERO switch for five (5) seconds meter will show 4.00 ma 6. Using Pressure Pump, apply desired pressure to sensor 7. Once desired pressure has been achieved, depress SPAN switch for five (5) seconds this will program new calibration range 8. Release calibration pump pressure 9. Be sure ma meter reading returns to 4.00 ma If not, sensor orientation may have moved while performing calibration, return to step 5 and repeat process 10. Install sensor back into vessel and perform a ZERO calibration unit is ready for service at this time

PAGE 15 2.8 CONTROLLER TUNING As depicted in Figure 2-1, the typical application utilizes the signal from the transmitter to interface with a programmable controller. In turn, this unit typically sends an output that is used to throttle a feed valve. For actual P (Proportional), I (Integral) and D (Derivative) tuning information, please consult the instruction manual provided with the controller. Some general controller setup guidelines are as follows: " WC = (Inches height X specific gravity of product) 1. The transmitter is calibrated in " WC. If the vessel is less than 30" WC height, the default calibration for the transmitter remains at 30" WC. Be sure to set the controller accordingly. 2. Be sure that either the controller is capable of providing proper loop power, or that an external supply is utiized. Refer to the controller instruction manual for guidelines on proper wiring of an internal supply. Utilize Figure 2-3 as a reference to be sure that all loop polarities are wired correctly. 3. On a typical controller, the following are the basic requirements to perform initial startup. Again, refer to the actual manual for detailed instructions. a. Specify a 4-20 ma input type to match the output of the transmitter. b. Be sure any configuration switches internal to the controller are properly set. c. Be sure wiring of loop/power source is correct. d. Enter a "Lower" and "Upper" operating limit - typically 0-100%.

PAGE 16 Section 3 Maintenance and Troubleshooting 3.1 GENERAL Required maintenance of the LD/LA transmitter includes a yearly calibration program. In addition, a visual check of the diaphragm and gasket should take place at minimum-6 month intervals. Small dents in the diaphragm will cause a "pre-load" or positive zero offset, which generally can be adjusted out. Larger dents, creases, or punctures are very detrimental and may require a complete repair or replacement. NOTE: The transmitter should be left in place for normal cleaning operations. Removal of the unit opens risk for damage to the diaphragm area. If the transmitter must be removed, a protective cap should be immediately placed over the diaphragm area. Be sure that the cap does not press on the diaphragm directly. The transmitter has been designed to withstand typical process environments including cleaning and washdown. Electronics are self compensating for changes in process temperature, and provide a linear, repeatable output signal. For proper operation, be sure that the diaphragm (sensing) portion of the unit remains free from damage. This portion should be well protected if the transmitter is removed from the process. A typical "Zero" adjustment should be performed at one (1) year intervals. 3.2 CALIBRATION CHECKS To maintain proper accuracy, Anderson recommends yearly ZERO signal (4.00 ma) checks. A record of these readings will help to maintain a consistent schedule. If re-zeroing does not correct inaccuracies seen in the receiver, calibration of the receiver itself should be performed. Consult associated manuals for your individual equipment. WARNING: Unless performing full calibration of the unit, do not adjust the "SPAN". This adjustment is Factory set. Testing of the transmitter "SPAN" will require stepping through one of the procedures outlined in the Calibration section (section 2) or the use of a stand alone pressure calibration system. The unit may also be returned to the factory for calibration. Call Anderson Technical Services directly for further information. 3.3 VENT SYSTEM The model LD/LA Level Transmitter utilizes an integral stainless steel atmospheric vent. The system vent must be maintained to allow for proper operation of the unit. Be sure the atmospheric vent area is not obstructed. These ports must be open and free from debris. DO NOT use sharp objects to free foriegn material from this area. Flush with warm-low pressure water.

PAGE 17 3.4 TROUBLESHOOTING As with any current loop, power supply and loop continuity are both imperative. If a problem occurs, a methodical approach, beginning at the power supply is best. 3.4.1 Troubleshooting Steps 1. Measure power supply voltage across "loop+" and "loop-" terminals. Meter will read between 12 and 40 VDC. (meter set to DC volts) 2. Disconnect one wire (+) from the signal receiver and install an accurate milliamp meter in series with the receiver. The signal should correspond proportionally to the height of liquid in the tank. (meter set to DC ma) NOTE: Above may differ if signal scaling is being done via microprocessor based receiver. Product specific gravity values must be used in calculation. 3. If step 1 and 2 are satisfactory, the problem is with the receiver. (If supplied by Anderson, refer to the instruction manual for that instrument). 4. Check all wiring connections between loop components. If OK, proceed to step 5. 5. With loop disconnected, the next step is to determine if there is a short to the housing. This is accomplished by placing the (+) lead of the ohm meter on the loop+ terminal, and the (-) lead to the housing. The process should then be reversed. In both cases, the meter should register infinite resistance. The process should then be repeated on the loop- terminal of the sensor. Again, the meter should register infinite resistance. If test is OK, proceed to step 6, 6. Wire transmitter independently of loop using two 9 volt batteries for power and milliamp meter as a receiver. If signal is proper, approximately 4 ma with no product on sensor, then problem is with external wiring. NOTE: Be sure to observe proper polarity as described in Figure 2-3 If any of the above indicate a transmitter problem, call your local distributor, or Anderson Technical Service directly.

PAGE 18 Appendix A Warranty and Return Statement These products are sold by The Anderson Instrument Company (Anderson) under the warranties set forth in the following paragraphs. Such warranties are extended only with respect to a purchase of these products, as new merchandise, directly from Anderson or from an Anderson distributor, representative or reseller, and are extended only to the first buyer thereof who purchases them other than for the purpose of resale. Warranty These products are warranted to be free from functional defects in materials and workmanship at the time the products leave the Anderson factory and to conform at that time to the specifications set forth in the relevant Anderson instruction manual or manuals, sheet or sheets, for such products for a period of two years. THERE ARE NO EXPRESSED OR IMPLIED WARRANTIES WHICH EXTEND BEYOND THE WARRANTIES HEREIN AND ABOVE SET FORTH. ANDERSON MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE PRODUCTS. Limitations Anderson shall not be liable for any incidental damages, consequential damages, special damages, or any other damages, costs or expenses excepting only the cost or expense of repair or replacement as described above. Products must be installed and maintained in accordance with Anderson instructions. Users are responsible for the suitability of the products to their application. There is no warranty against damage resulting from corrosion, misapplication, improper specifications or other operating condition beyond our control. Claims against carriers for damage in transit must be filed by the buyer. This warranty is void if the purchaser uses non-factory approved replacement parts and supplies or if the purchaser attempts to repair the product themselves or through a third party without Anderson authorization. Returns Anderson s sole and exclusive obligation and buyer s sole and exclusive remedy under the above warranty is limited to repairing or replacing (at Anderson s option), free of charge, the products which are reported in writing to Anderson at its main office indicated below. Anderson is to be advised of return requests during normal business hours and such returns are to include a statement of the observed deficiency. The buyer shall pre-pay shipping charges for products returned and Anderson or its representative shall pay for the return of the products to the buyer. Approved returns should be sent to: ANDERSON INSTRUMENT COMPANY INC. 156 AURIESVILLE ROAD FULTONVILLE, NY 12072 USA ATT: REPAIR DEPARTMENT