MODEL , MODEL 310SAO, AND MODEL 310-ALT

Similar documents
Atkinson Dynamics Intercom Model AD-28X-MV Installation and Service Instructions

5570M Series Intercom Installation and Operation Guide

PRICE $2.00 MODEL PA500M* AMPLIFIER SERVICE MANUAL

SETUP and OPERATING MANUAL ADVANCED MULTI-CHANNEL VEHICLE INTERCOM SYSTEM (AMCVIS)

CommCenter Digital Message Center

MZ2 HEADPHONE AMPLIFIER, PREAMP, & STEREO AMPLIFIER USER GUIDE

Model WM1000/WM2000. Wall Mount Intercom Stations. User Instructions

Installation and Operation Manual

Ambient Level Controller

EDACS WALL MOUNT STATION. Maintenance Manual. Mobile Communications LBI-31838A TABLE OF CONTENTS

AD-8100 & AD-8200 Servo Amplifiers

1160 Stereo Power Amplifier

Sealed Interface Control: EC20300

Model 1791 VHF Radio User's Manual

Installation and Operation Manual

3050 Stereo Power Amplifier

TOA 500 SERIES MIXER POWER AMPLIFIER

HF-SSB MICOM - LINK - FDN6123 HF-SSB MICOM - LINK

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46

Boulder W Mono Power Amplifier

Explosion Proof Page/Talk Paging Amplifier

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

TM-800 Main Station. Instruction Manual. TELIKOU Systems All Rights Reserved

USER MANUAL VIVALDI MZ550A. Distribution Mixer Amplifier

DD1-1300S. 500 Watts RMS Watts RMS Watts RMS- 1. Mono-Bloc Digital Power Amplifier

Dynamo Brushless DC Motor and GreenDriveTM Manual

MIXER POWER AMPLIFIER BG-130

ALM473 DUAL MONO \ STEREO AUDIO LEVEL MASTER OPERATION MANUAL IB

OPERATING INSTRUCTIONS AND SERVICE MANUAL BASKETBALL SCOREBOARD MODEL MP-5209 WITH MP-5000 CONTROL

BC145 SIGNAL ISOLATOR BOARD

User Manual. MA 21 Two zone mixing amplifier

Flying Never Sounded So Good

IP Series DUAL POWER AMPLIFIERS

AELIUS YPSILON POWER AMPLIFIER. OWNERS MANUAL V1 01/01/20010 All rights reserved

INSTALLATION INSTRUCTIONS ATV WINCH MULTI-MOUNT Multi-Mount Mounting-Kit: PN Application: YAMAHA BIGBEAR 00+

FMR622S DUAL NARROW BAND SLIDING DE-EMPHASIS DEMODULATOR INSTRUCTION BOOK IB

OPERATING INSTRUCTIONS AND SERVICE MANUAL HOCKEY SCOREBOARD MODEL MP-5529 WITH MP-5000 CONTROL

FREQUENCY AGILE FM MODULATOR INSTRUCTION BOOK IB

CMP-300 Composite Mixer/ Distribution Amplifier

Model 7000 Low Noise Differential Preamplifier

i. AM. Radio Transmitter Installation and Operation Easy to follow instructions on how to program and use your Model 5.0 i. AM.

LBI-4938C. Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3. Printed in U.S.A. Maintenance Manual

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

Installation, Operation and Maintenance Manual

HOOKING IT UP. Unpacking and Inspection. Installing in a Rack CHAPTER 3: Hooking It Up

SR3400 Base Station Module Configuration and Use Series-2 Cards Only

Owner s Manual B 300 B 600 B 900 B 1200 B 1500 B 902 B 1202 B 1802 B300 B1802

LogiTALKER OWNER S MANUAL. Voice Keyer. Idiom Press. PO Box 1015, Merlin, OR USA

Boulder W Class A Stereo Power Amplifier

INSTALLATION INSTRUCTIONS Medium Flat Panel Model MSP-SI1

Senior Swing. Caution

plifier D-501 otion Am Tactile M

Radio Control Installation and Operating Instructions System 4

MAINTENANCE MANUAL SPEAKER/MICROPHONE KRY /33 EARPHONE RLD /4

ELECRAFT Application Note

PS 260T DUAL CHANNEL AUDIO INTERFACE USER MANUAL

Nocturne+ E INSTRUCTIONS CAUTION. Motor Operated Exterior Projection Screen. 1¾ (45mm) END CAP. Wall Mounting Bracket. Wall Mounting Bracket

MASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2. Maintenance Manual LBI-30766L. Mobile Communications

1825 Duet Plus Installation Guide

DPA602 1/7. Multi-Channel Network Amplifier. General Description. Features. Applications. AtlasIED.com. DPA602 Front. DPA602 Back

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

20-27B. Tone Panel. Version 1.10

SA 125 mixer amplifier. user manual

PERMA Series Revision 2 Amplifiers

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

PagePac Plus AmpliCenter V A - (D300A) V A - (D100A) V (D40) Installation and Use

Sigtronics Auto Squelch Intercom System Installation and Operating Instructions Models SAS-440 and SAS-640

HOLE CUTTER SHARPENER ASSEMBLY & SERVICE MANUAL

INSTRUCTION MANUAL (ATEX / IECEx)

TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A

ADA416-XLR DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

ECI 6D. Balanced Integrated Amplifier. Owner's Manual. (with a built-in DAC) ENGLISH

INSTALLATION AND OPERATION MANUAL. Multiple-Radio Interface Module 41021G P-26 (11-12) 2012 David Clark Company Incorporated

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions

POWER SUPPLY MODEL XP-720. Instruction Manual ELENCO

See Page 8 for Part Numbers

Distribution Amplifiers 1

PagePac Plus AmpliCenter V A/V A Installation and Use

Talk Back Intercom System

WOO AUDIO WA2. Stereo Headphone & Pre Amplifier. Single-Ended, Class-A, Output Transformer-Less (OTL) Owner s Manual

PagePac Plus AmpliCenter V /V /V

************* OWNER'S MANUAL STAX1250/2 STAX1800/2 STAX2200/2 STAX1200/4 STAX1600/4 STAX2300/4 STAX2000/1D STAX4000/1D STAX5500/1D

Opus 21 s80 Integrated Amplifier Owner's Manual

CAP ANALOG 410 INSTALLATION & OPERATION MANUAL

VARIABLE SPEED WOOD LATHE

Current Loop Interface Module M 2025D

AUDIO MODE SELECTOR MODEL AMS-6000

Conic Systems Inc. INSTRUCTION MANUAL FOR DATATRAN C2547 UNIVERSAL AMPLIFIER MODULE

Owner s manual. SDA 2175 Semi Digital Amplifier

Data Isolation Cards. 2-Wire HDSL/56KBS Isolation Card P Wire HDSL/56KBS Isolation Card P30050

LBI-31807D. Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1. Maintenance Manual. Printed in U.S.A.

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

MODEL NC221 MOBILE TWO-TONE SEQUENTIAL DECODER INSTRUCTION MANUAL

Current Probes. User Manual

30DC Speed Lathe Manual

Illustration 1 Back panel. Illustration 2 Front panel

RPS /02 Effective for models with serial numbers beginning with "G".

Trident Laundry Chemical Delivery System

Transcription:

MODEL -0, MODEL SAO, AND MODEL -ALT VOLUME CALL AudioMaster MODEL -0 VOLTS: / VDC FEDERAL SIGNAL CORPORATION UNIVERSITY PARK, IL. U.S.A. WARNING: DISCONNECT POWER BEFORE REMOVING COVER TALK TM LISTEN 0A0 INSTALLATION AND SERVICE INSTRUCTIONS

INSTALLATION AND SERVICE INSTRUCTIONS FOR MODELS -0, SAO, AND -ALT SAFETY MESSAGE TO INSTALLERS, USERS AND MAINTENANCE PERSONNEL People s lives depend on your safe installation or our products. It is important to read, understand and follow all instructions shipped with the products. In addition, listed below are some other important safety instructions and precautions you should follow: This is not a Listed safety device and is not intended to be used as such. To properly install this intercom, you must have a good understanding of automotive electrical procedures and systems. Disconnect power before connecting or doing any maintenance on this intercom. All effective warning speakers produce loud sounds which may cause in certain situations, permanent hearing loss. You should take appropriate precautions such as wearing hearing protection. After testing is complete, provide a copy of this instruction sheet to all operating personnel. File these instructions in a safe place and refer to them when maintaining and/or reinstalling the product. Establish a procedure to routinely check the intercom installation for integrity and proper operation. You should frequently inspect the intercom to ensure that it is operating properly and that it is securely attached to the vehicle. Failure to follow all safety precautions and instructions may result in property damage, serious injury, or death to you or others. A. GENERAL FEATURES. The -0 intercom is a heavy duty, -way, communications device designed for vehicular applications. Nominal operating voltage is VDC. The positive () power line is fused with a amp 0 volt type GMC fuse. The unit also offers internally selectable balanced or unbalanced line operation, transformer isolated audio inputs and internally selectable Master or Slave mode configurations. A call button with remote call dry contacts is also factory supplied in the unit. The Model SAO is a -0 with a factory installed cable. Per customer specifications, it is factory preset as a master or slave with balanced or unbalanced line operation. --

MASTER MODE: Each intercom can be configured as a Master unit (Push-to-Talk) or a Slave unit (Push-to-Listen) by changing the MAS/SLA jumper (J) on the printed circuit board (see figure ). The intercom comes from the factory set in the Master (MAS) mode. In the Master mode the intercom acts as an amplifier, constantly broadcasting over its speaker any signal that it receives on the signal lines. Holding down the Listen/Talk switch changes the unit from a speaker to a microphone (see figure ). The intercom will now transmit over the signal lines to additional intercom(s) also set in the master mode. When the switch is released it will default back to the Listen or Speaker mode, allowing the user to receive any messages transmitted back to it. SLAVE MODE: Some applications may require that the intercom constantly transmit (i.e. act as a microphone) as opposed to constantly receive (i.e. act as a speaker). To accomplish this the intercom must be switched into the Slave (Push-to-Listen) mode. To switch an intercom into the Slave mode there are three steps to follow. WARNING Disconnect power to the intercom before any installation, maintenance, or configuration changes are performed. CR C HS CR RV CR CR C L R R C R C R IC HS C Q CR JP CR CR R C K CR CR CR Q C RN R RN C K Q RN IC IC R C C R C C C0 C C C C R R R C R C C R CR C R R C RN IC R C 000A-0 SW 0VAC T RV PTC GMC 0VAC /A F A J 0V RV MAS RV RV J SLA C J C J J J BAL UNB YEL BLK J T MASTER/SLAVE TO CONTROL PANEL SPEAKER PLUG BALANCE/ UNBALANCE 0AB Figure. --

LISTEN PUSH DOWN TO TALK VOLUME CALL TALK Figure. 0A Move the J jumper on the P.C. board from the MAS to SLA position (see figure ). This can be done using long nose pliers, pulling the block off the MAS and center position and placing it on the SLA and center position. An intercom configured in the Slave mode needs to have the Listen/Talk switch default to the talk position on the cover plate (see figure ). The second change required is to rotate the position of the Talk/Listen switch. This can be accomplished by loosening the rubber boot covering the toggle switch enough to allow the toggle switch to turn 0 degrees. The dimple on the locking ring must seat itself in the locating hole (see figure ). The rubber boot is then tightened up against the cover plate with the toggle switch leaning to the talk position, as shown in figure. The third change involves the interconnect wiring. When a unit is placed in the Slave mode it defaults to the Talk or transmit position. When hooked to a Master unit it is necessary to override the Slave unit in order for the Master unit to be able to transmit. The # pin (remote) on both terminal blocks (see figure ) must be connected between the Master and the Slave unit. Wiring diagrams of typical intercom configurations are shown in Paragraph G. CONTROL: Remote control is used to change the operation mode of a remote intercom from listen to talk or from talk to listen upon activation of a local intercom. The wiring diagram section illustrates Master/Slave Installation and Using Foot Switches Diagrams. (See figures and.) Normally open foot switches can also be connected to the Remote Control line in order to allow hands free operation of the listen/talk functions. --

LISTEN VOLUME CALL TALK PUSH UP TO LISTEN Figure. 0A CALL BUTTON: Depressing the call button sends a khz tone onto the signal lines. All units listening to the line will then broadcast this signal as a call. CAUTION The call signal is substantially louder than normal voice messages being carried on the line. Do not depress the call switch while carrying on a conversation with someone on the system. This will subject the listener to very loud sound levels. The volume of the call signal is affected by the volume control on the receiving unit, so if the volume is turned all the way down at a receiving station, the call signal will not be heard. To avoid this problem, the call dry contacts can be utilized to drive an external signalling device. DIMPLE LISTEN/TALK TOGGLE SWITCH GRAY ORANGE YELLOW BLACK VOLUME CONTROL BLACK BLACK DIMPLE BROWN CALL PUSH BUTTON BACK VIEW 0A Figure. --

WIRE COLORS SHOWN ARE FOR THE MODEL SAO FACTORY INSTALLED CABLE. TERMINAL BLOCK PINOUT BROWN YELLOW PURPLE ORANGE FOR CALL AUDIO AUDIO () BLUE CONTROL NC WHITE V INPUT BLACK RED V INPUT GREEN CHASSIS Figure. CALL S TO EXTERNAL DEVICE: 0AB Depressing the call button also closes a normally open dry contact at pins and on the terminal block. The contact is rated at. amps @ VDC or.0 amps @ VDC. This contact can be used to trigger a higher rated relay, a remote sounder, or a light in order to accent the call feature. The wiring diagram illustrates how an external light or horn can be wired in to augment the call tone. (See figure.) ISOLATED BALANCED/UNBALANCED LINES: The audio signals for the -0 are transmitted over a wire pair using balanced line technology. This means each wire carries a signal that is opposite in polarity of the other. At the input of the intercom is an isolated balanced line transformer. This transformer subtracts the two signals from each other providing an output free of noise generated onto the wires by some other noise source such as a motor or light fixture near the wires. The isolation provided by the transformer means that the grounds of the units are not connected by the audio lines. Therefore, ground loops and other problems caused by non-isolated systems are avoided. The polarity of the audio lines between the and - signal terminals need not be maintained. A shielded cable can be used in installations where extreme problems from interference are suspected. The shield should always be connected to the ground of only one of the intercoms. Connecting the shield to ground at both ends will cause ground currents to travel through the shield which could cause hum in the system. There are several diagrams in the back of the manual to aid in wiring intercoms together. The wiring diagram section illustrates balanced and unbalanced line interconnection along with how a shielded audio cable can be used. (See figures through.) It also illustrates multiple intercom interconnections. --

SURGE PROTECTION: Metal Oxide Varistor (MOV) devices are used to protect the audio lines and the remote control line. The intercom must have Earth Ground terminated to it to ensure surge protection. The output amplifier of the -0 offers full short-circuit protection and overheat protection. --

MODEL -0 SPECIFICATIONS Operating Voltage Range... VDC to VDC on the V input 0VDC to 0VDC on the V input Nominal Voltage... VDC/VDC Current Draw Voltage Operating Standby VDC 0.A 0.A VDC 0MA MA Amplifier Specifications Frequency Response (-db)... 0Hz to Khz Input Impedance... 00 Ohms Max. Output Voltage Sine Wave: Balanced Output... VRMS Unbalanced Output....VRMS Square Wave: Balanced Output... VRMS Unbalanced Output....VRMS Speaker Rating... 0 Watts Speaker Impedance... Ohms Temperature Range... - to 0 F (- to C) Fuse,Type GMC-... AMP, 0 VOLT Call Switch Contact Rating....A @ VDC.0A @ VDC Weight Shipping... Lbs., oz. Net... Lbs., oz. Housing Dimensions... -/" W x -/" H x -/" D Conduit Entrances... Dual /"- IPS Housing Material... Aluminum Color... Grey --

B. UNPACKING. After unpacking the unit, examine it for damage that may have occurred in transit. If the equipment has been damaged, do not attempt to install or operate it, file a claim immediately with the carrier stating the extent of the damage. Carefully check all envelopes, shipping labels and tags before removing or destroying them. Model SAO is factory preset for master/slave and balanced/unbalanced line operation. The label on the carton indicates the factory settings. Before attempting to install the intercom, be sure that all parts listed in the KIT CONTENTS LIST have been supplied. C. KIT CONTENTS LIST. Qty. Description Part Number Wiring Block 0A Instruction Sheet Resistor, K, W (Not included with Model -ALT) NOTE The resistor and the wiring block are not included with the Model SAO. D. MOUNTING. CAUTION The selection of the mounting location for the device, its controls and the routing of the wiring is to be accomplished under the direction of the facilities and the safety engineer. The intercom is intended to be mounted on any relatively flat and rigid surface by the two mounting ears on the exterior of the housing. Figure is a dimensional outline drawing showing the proper mounting configuration. The two mounting ears are /" diameter holes spaced -/" apart. Hardware for mounting the intercom to the surface is left up to the installer. WARNING This unit is heavy and should be mounted on a rigid surface capable of supporting the weight of the intercom. The intercom housing has two /"- IPS openings in the bottom. When installing the conduit to these openings seal the threads with pipe compound or other sealing material. --

.0. 0 0.0 HOLES.0 VOLUME CALL LISTEN TALK... Figure. -- /- PIPE THREAD PLACES. 0A E. ELECTRICAL CONNECTIONS. WARNING Do not connect wires when power is applied. NOTE The Model SAO is supplied with a color-coded cable. Wiring is terminated to the color-coded wires (see figure ). Also, the unit is preset (master/slave and balanced/unbalanced) at the factory. The factory settings are indicated on the carton label. All wiring to the intercom is terminated to the terminal block provided. The terminal block plugs into a header on the PC board and is configured such that it can only plug in one way. Figure shows the orientation of the wiring block and describes the function of each position. NOTE Pins and are connected together on the circuit board for a common ground. There are three jumpers shown on the PC board in Figure which may need to be moved depending on the desired operation of the intercom. J and J are for operating the intercom in either a balanced signal line or unbalanced signal line configuration. These must be moved together as a pair. They are factory set in the balanced line position. J is for configuring the intercom as either a master or slave device. The intercom is factory set in the master position. See figures through for typical intercom configurations.

CR C HS R Q C C C IC C C0 C C C C R C RV CR CR C CR L R C C IC R R HS C CR JP CR CR R K CR CR CR Q RN R RN K Q RN IC R C R C C R R C C R C R CR C R R RN IC R C 000A-0 SW TERMINAL BLOCK PINOUT FOR CALL AUDIO AUDIO () CONTROL V INPUT V INPUT CHASSIS 0VAC 0VAC T GMC /A RV PTC F A J 0V MASTER/SLAVE RV MAS RV J SLA RV C J TO CONTROL PANEL C J BAL J J UNB YEL BLK J T SPEAKER PLUG BALANCE/ UNBALANCE 0AC Figure. F. SERVICE. CAUTION Any maintenance must be performed by a trained electrician.. General. CAUTION The call signal is substantially louder than normal voice messages being carried on the line. Do not depress the call switch while carrying on a conversation with someone on the system. This will subject the listener to very loud sound levels. Federal Signal will service your equipment or provide technical assistance with any problems that cannot be handled locally. Units may be returned to Federal Signal for service or repair. A brief explanation of the service requested or the nature of the malfunction, should be given. Address all communications and shipments to: Service Department Signal Division Federal Signal Corp. Federal Signal Dr. University Park, IL 0- -00-- --

. Replacement Parts. WARNING Replace fuse with GMC- only. DO NOT substitute. Description Part Number PC Board Assy., -0 000 PC Board Assy., -ALT 000-0 Potentiometer A Toggle Switch A Push Button Switch A Knob, Pot A Rubber Boot, Tgl, Open A Rubber Boot, Button A Rubber Boot, Pot A Terminal Block 0A Speaker/Housing Assembly 00 Cover Gasket 0A00 Resistor, K, W (Not included with Model -ALT) Fuse, GMC- A-0 G. WIRING DIAGRAMS. --

INTERCOM I MASTER AUDIO V INPUT V INPUT MASTER/SLAVE INSTALLATION K WATT Master/Slave Installation INTERCOM II SLAVE AUDIO V INPUT V INPUT 0AB In this installation, the Master is constantly broadcasting audio from the Slave. Pushing the listen/talk switch on either unit forces the Slave into the listen mode and the Master into the talk mode. The MAS/SLA jumper must be placed in the SLA mode for this operation. The K resistor is not required on Model SAO. Figure. AUDIO V INPUT V INPUT INTERCOM I MASTER () USING FOOT SWITHCES FOOT SWITCH N.O. K WATT FOOT SWITCH N.O. () INTERCOM II MASTER AUDIO V INPUT V INPUT 0A0B Using Foot Switches Using normally open contact foot switches (customer supplied) allows for total hands free operation of the listen/talk functions. The K resistor is not required on Model SAO. Figure. --

POWER LIGHT/HORN ETC. USING CALL DRY CONTACTS LIGHT/HORN ETC. POWER INTERCOM I MASTER AUDIO V INPUT V INPUT () K WATT () INTERCOM II SLAVE AUDIO V INPUT V INPUT 0AB Using Call Dry Contacts The dry contacts can be used to switch devices such as an auxiliary sound or light when call is depressed. The maximum ratings for the dry contacts are amps @ VDC and. amps @ VDC. An additional relay is required if the load exceeds these ratings. This method assures a call is received even when the volume on one of the intercoms is turned all the way down. The K resistor is not required on Model SAO. Figure. AUDIO V INPUT V INPUT INTERCOM I MASTER () BASIC BALANCED LINE SYSTEM K WATT Basic Balanced Line System () INTERCOM II SLAVE AUDIO V INPUT V INPUT 0AB This is a simple system with only two conductors connected between the units. DC power is utilized at both sites. The Unit is configured for balanced line operation. (NOTE: both jumpers in BAL position.) The K resistor is not required on Model SAO. Figure. --

INTERCOM I MASTER AUDIO V INPUT V INPUT () SHIELDED BALANCED LINE SYSTEM K WATT () INTERCOM II SLAVE AUDIO V INPUT V INPUT Shielded Balanced Line System 0AB This system offers maximum isolation from noise over long runs. The shield should only be grounded at one side. DC power is utilized at both sites. The unit is configured for balanced line operation. (NOTE: both jumpers in BAL position.) The K resistor is not required on Model SAO. Figure. AUDIO V INPUT V INPUT INTERCOM I MASTER () BASIC UNBALANCED LINE SYSTEM K WATT Basic Unbalanced Line System This configuration is used when hooking to other products on the market. This system does not offer the same level of noise isolation as a balanced line system and should only be used when hooking to existing devices. The neighboring jumpers on the circuit board must be changed from the BAL position to the UNB position for these installations (see figure ). The K resistor is not required on Model SAO. Figure. AUDIO GND. 0AB --

C REV. C 0 Printed in U.S.A.