Power Measurement Basics

Similar documents
Agilent EPM-P Series Single- and Dual-Channel Power Meters Agilent E9320 Family of Peak and Average Power Sensors

LB680A Pulse Profiling USB PowerSensor+ Data Sheet

LB480A Pulse Profiling USB PowerSensor+ Data Sheet

LB480A Pulse Profiling USB PowerSensor+ Data Sheet

INSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL Copyright 2008 by Bird Electronic Corporation Instruction Book P/N Rev.

RF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet

Keysight Technologies RF and Microwave Power Meters and Sensors for Radar Testing. Application Note

Technical Datasheet GT-8550B Series USB Power Sensor 10 MHz to 26.5 GHz

Data Sheet. Peak, CW & Average. Power Sensors. Taking performance to a new peak

LB679A CW and Pulse (Modulation) USB PowerSensor+ Data Sheet

Keysight Technologies Choosing the Right Power Meter and Sensor. Product Note

Advanced Test Equipment Rentals ATEC (2832)

POWER-MEASUREMENT needs can vary greatly among different

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Bird Model 7022 Statistical Power Sensor Applications and Benefits

GET10B Radar Measurement Basics- Spectrum Analysis of Pulsed Signals. Copyright 2001 Agilent Technologies, Inc.

Agilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software

Cost-Effective Traceability for Oscilloscope Calibration. Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK

RF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet

Amplifier Test Bench Taking performance to a new peak

Keysight Technologies Educational Overview of RF Power Measurement and Applications

Pulsed VNA Measurements:

Improving Amplitude Accuracy with Next-Generation Signal Generators

Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

Keysight Technologies Waveguide Power Sensors. Data Sheet

N8480 Series Thermocouple Power Sensors DATA SHEET

LadyBug Technologies, LLC LB5926A True-RMS Power Sensor

Keysight Technologies Techniques for Precise Power Measurements in the Field

R&S NRP-Zxx Power Sensors Specifications

Data Sheet. RF Power Meter. Taking performance to a new peak

Traceability and Modulated-Signal Measurements

Keysight Technologies N8480 Series Thermocouple Power Sensors. Data Sheet

Pulse Timing and Latency Measurements Using Wideband Video Detectors

Agilent N8480 Series Thermocouple Power Sensors

Radiofrequency Power Measurement

Agilent EPM Series Power Meters

8480 Series Power Sensor Specifications

Utilizzo del Time Domain per misure EMI

Agilent 8902A Measuring Receiver

RF Peak Power Analyzer

Agilent U2000 Series USB Power Sensors. Data Sheet

DATA SHEET. N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors

Agilent N1913A and N1914A EPM Series Power Meters

MODEL VXIbus UNIVERSAL METER. Page 1 of 5

Platform Migration 8510 to PNA. Graham Payne Application Engineer Agilent Technologies

Keysight Technologies E8257D PSG Microwave Analog Signal Generator. Data Sheet

Agilent EPM Series Power Meters E-Series and 8480 Series Power Sensors. Data Sheet. Product specifications and characteristics

Frequency and Time Domain Representation of Sinusoidal Signals

Pulsed S-Parameter Measurements using the ZVA network Analyzer

N432A Thermistor Power Meter DATA SHEET

3250 Series Spectrum Analyzer

Keysight Technologies PNA-X Series Microwave Network Analyzers

LadyBug Technologies, LLC LB5918L True-RMS Power Sensor

GSM Transmitter Modulation Quality Measurement Option

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

Agilent E9300 Power Sensors E-Series Technical Overview

Contents. CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer

Agilent 83711B and 83712B Synthesized CW Generators

E-series E9300 Average Power Sensor Specifications

PNA Family Microwave Network Analyzers (N522x/3x/4xB) CONFIGURATION GUIDE

Traceability for Oscilloscopes and Oscilloscope Calibrators

4530 Series RF Power Meter

Advanced Test Equipment Rentals ATEC (2832) Keysight N8480 Series Thermocouple Power Sensors. Data Sheet

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Agilent Pulsed Measurements Using Narrowband Detection and a Standard PNA Series Network Analyzer

Model 855 RF / Microwave Signal Generator

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent 4-Port PNA-L Network Analyzers

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Agilent N5531S Measuring Receiver

U2020 X-Series USB Peak and Average Power Sensors DATA SHEET

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Fast and Accurate Simultaneous Characterization of Signal Generator Source Match and Absolute Power Using X-Parameters.

IREAP. MURI 2001 Review. John Rodgers, T. M. Firestone,V. L. Granatstein, M. Walter

Agilent PN 4395/96-1 How to Measure Noise Accurately Using the Agilent Combination Analyzers

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz

Understanding RF and Microwave Analysis Basics

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

PM Series Microwave Power Calibration System

ETSI Standards and the Measurement of RF Conducted Output Power of Wi-Fi ac Signals

Agilent. E8267C PSG Vector Signal Generator E8257C PSG Analog Signal Generator E8247C PSG CW Signal Generator

Agilent ESA-L Series Spectrum Analyzers

HP 8901B Modulation Analyzer. HP 11722A Sensor Module. 150 khz MHz. 100 khz MHz. Technical Specifications. Four Instruments In One

Albuquerque, New Mexico

Many devices, particularly

Agilent 71400C Lightwave Signal Analyzer Product Overview. Calibrated measurements of high-speed modulation, RIN, and laser linewidth

RF Fundamentals Part 2 Spectral Analysis

Conversion Gain Measurements on Mixers with Different Input and Output Impedances

Model 865 RF / Ultra Low Noise Microwave Signal Generator

APPH6040B / APPH20G-B Specification V2.0

Measurements 2: Network Analysis

Noise by the Numbers

Keysight Technologies

100 Hz to 22. HP 8566B Spectrum Analyzer. Discontinued Product Support Information Only. Outstanding Precision and Capability

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Model 7000 Series Phase Noise Test System

Measurement of Digital Transmission Systems Operating under Section March 23, 2005

Scalar Network Analysis with U2000 Series USB Power Sensors

Keysight Technologies E8257D PSG Microwave Analog Signal Generator

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Transcription:

Back to Basics - 2006

Objectives On completion of this module, you will be able to: Explain the importance of power measurements Define the three basic types of power measurements Describe the power meter/sensor measurement method Explain the two most prevalent sensor technologies Describe advanced measurements used for the latest RF & microwave applications Calculate power measurement uncertainty Outline Agilent s broad range of power measurement solutions

Agenda Importance of Power Measurements Average, Peak and Pulse Power Power Meter & Sensor Measurement Method Sensor Technologies Agilent Power Measurement Solutions Time-Gated Power Measurements Advanced Power Measurements Measurement Uncertainty, Standards and Traceability Agilent Power Sensor Selection Guides (Appendix)

Signal Power Levels are Critical Too low: Signal buried in noise Too high: Nonlinear distortion......or even worse!

Importance of Power Measurements Critical to specified performance at every level of a system Many measurements made in design and manufacturing Measuring equipment and techniques must be: Accurate Repeatable Traceable Convenient

Why Not Measure Voltage? DC Low Frequency + V ± Z S R L P = IV = V 2 /R Z S V R L I I High Frequency Z S Z O R L I and V vary with position Power is constant AC component of power V Inc Amplitude P DC component of power V Ref I t V

Agenda Importance of Power Measurements Average, Peak and Pulse Power Power Meter & Sensor Measurement Method Sensor Technologies Agilent Power Measurement Solutions Time-Gated Power Measurements Advanced Power Measurements Measurement Uncertainty, Standards and Traceability Agilent Power Sensor Selection Guides (Appendix)

Units and Definitions Power = energy transferred per unit time Basic power unit is the watt (W) 1 W = 1 A x 1 V A logarithmic (decibel) scale is often used to compare two power levels Relative power in decibels (db) = 10 log(p 2 /P 1 ) Absolute power is expressed by assigning a reference level to P 1 Power (dbm) = 10 log(p/1 mw)

Average Power AM Average over many modulation cycles Pulsed Average over many pulse repetitions t

Pulse Power Power Pulse Power = Average Power/Duty Cycle Rectangular pulse Constant duty cycle A (pulse width) Duty Cycle = A B B (pulse repetition interval) Time

Envelope Power and Peak Envelope Power Instantaneous Power Peak Envelope Power Peak Power Envelope Power

Agenda Importance of Power Measurements Average, Peak and Pulse Power Power Meter & Sensor Measurement Method Sensor Technologies Agilent Power Measurement Solutions Time-Gated Power Measurements Advanced Power Measurements Measurement Uncertainty, Standards and Traceability Agilent Power Sensor Selection Guides (Appendix)

Instruments That Measure RF & Microwave Power Power Meter and Sensor Network Analyzer ± 0. 0X db > 70 dbm Vector Signal Analyzer ± 0. X db or greater Frequency selective Spectrum Analyzer

The Power Meter and Sensor Method RF power Power Sensor Thermistor Thermocouple Diode Detector DC or low-frequency equivalent Power Meter Display (dbm or W)

Agenda Importance of Power Measurements Average, Peak and Pulse Power Power Meter & Sensor Measurement Method Sensor Technologies Agilent Power Measurement Solutions Time-Gated Power Measurements Advanced Power Measurements Measurement Uncertainty, Standards and Traceability Agilent Power Sensor Selection Guides (Appendix)

Thermistors One of the earliest types of power sensors Have been replaced in most applications by thermocouples and diode detectors Still used for power transfer standards in metrology applications

Thermocouples A junction of two dissimilar metals generates a voltage related to temperature Junction temperature is directly related to RF power RF Power C c Cold Junction RF Input Hot Cold Hot Junction Thin-Film Thermocouples C b To DC Voltmeter

Diode Detectors R s + V s R matching C b V o -

Power Sensor and Meter Signal Path Power Sensor Power Meter RF Diode Detector DC Chopper AC BPF Ranging Synchronous Detector LPF ADC AUTOZERO 220 Hz Squarewave Generator DAC µprocessor

Square-Law Region of Diode Sensors Linear Region V O (log) V 2 O = nv = S n P IN Square-Law Region Noise Floor 0.1 nw 70 dbm 50 db P IN 0.01 mw 20 dbm

Wide Dynamic Range CW Power Sensors 70 to + 20 dbm = 90 db Dynamic Range Calibration Data

Agenda Importance of Power Measurements Average, Peak and Pulse Power Power Meter & Sensor Measurement Method Sensor Technologies Agilent Power Measurement Solutions Time-Gated Power Measurements Advanced Power Measurements Measurement Uncertainty, Standards and Traceability Agilent Power Sensor Selection Guides (Appendix)

P-Series, EPM-P and EPM Series Power Meters P-Series Power Meters Peak, average, peak-to-average ratio; time-gated measurements; rise time, fall time and pulse width; 30 MHz video bandwidth (N1911A/12A) EPM-P Series Power Meters Peak, average, peak-to-average ratio; time-gated measurements, 5 MHz video bandwidth (E4416A/17A) EPM Series Power Meters Average power measurements (E4418B/19B)

8480, E-Series and P-Series Power Sensors 8480 Series (Diode and Thermocouple) Average power from 70 to +44 dbm; 100 khz to 110 GHz; unlimited video BW Typical dynamic range of 50 db E-Series (Diode) E441X: 90 db dynamic range; CW only E9300: 80 db dynamic range; average power of any signal type; no BW limitation E9320: peak and average power from 50 MHz to 18 GHz; 5 MHz video BW P-Series (Diode) N192XA: peak and average from 50 MHz to 40 GHz; 30 MHz video BW

E9300 Average Power Sensor Technology Low-Power Path ( 60 to 10 dbm) RF Input High-Power Path ( 10 to +20 dbm) 80 db dynamic range with any signal type Two-path design Diode stack/attenuator/diode stack topology Automatic path switching

E9320: Two Sensors in One Package Sensor Diode Bulkhead Average-Only Path RF IN 50 ohms 3 db Load Filter * (300 khz, 1.5 MHz, 5 MHz lowpass) Chopper Switched Gain Preamp 50-ohm load Thermistor -t Av. PATH ISOLATE Normal (Peak) Path CW Differential Amp Variable Gain Differential DC Coupled Amplifier * (300 khz, 1.5 MHz, 5 MHz) PEAK AUTO-ZERO * Bandwidth is sensor dependent Thermistor Bias I 2 C Buffer Gain / Mode Control Sensor ID E 2 PROM GAIN SELECT SERIAL BUS

Agenda Importance of Power Measurements Average, Peak and Pulse Power Power Meter & Sensor Measurement Method Sensor Technologies Agilent Power Measurement Solutions Time-Gated Power Measurements Advanced Power Measurements Measurement Uncertainty, Standards and Traceability Agilent Power Sensor Selection Guides (Appendix)

Time-Gated Power Measurements EDGE signal (GSM) Peak, average and peak-to-average ratio of a single burst

Sensors for Time-Gated Measurements Sensor rise/fall time requirements For characterizing overshoot: < 1/8 signal rise time For average power: same as signal rise time E9320 peak/average sensors 200 ns rise time (typical) TDMA, CDMA and W-CDMA wireless formats P-Series wideband power sensors < 13 ns rise time and fall time Radar and pulsed component test

Triggering and Measurement Capabilities Ext Trigger Delay Start 1 EPM-P and P-Series Power Meters Start 2 Start 3 Length 2 Start 4 Average Length 3 Length 1 Peak Length 4 Triggers Level External GPIB

Agenda Importance of Power Measurements Average, Peak and Pulse Power Power Meter & Sensor Measurement Method Sensor Technologies Agilent Power Measurement Solutions Time-Gated Power Measurements Advanced Power Measurements Measurement Uncertainty, Standards and Traceability Agilent Power Sensor Selection Guides (Appendix)

Technology Drivers Aerospace and Defence (Radar) Digital Wireless Communications GSM (0.3 GMSK) EDGE (3/8 Shifted 8PSK) cdma2000 TDMA system Time-gated average power Fast measurements High-speed data transfer 3G technology Peak-to-average ratio CCDF

Peak Power Measurement System RF IN Power Sensor Video BW High-speed sampling measurement path (EPM-P/E9320) Detected envelope power High-frequency modulated signal power Key system characteristics: Sufficient video (modulation) bandwidth Wide dynamic range High-speed, continuous sampling

Wide Bandwidth and Fast, Continuous Sampling P-Series Power Meters and Sensors 30 MHz video bandwidth up to 40 GHz Continuous sampling at 100 Msample/s 0.5 μs/div = 50 samples per division

P-Series Power Meters and Sensors Key Measurements Peak, average, peak-to-average ratio; rise time, fall time and pulse width; time-gated and free-run measurements

P-Series Measurement Display Graphical trace setup Marker measurements and analysis MKR 1 MKR 2

EPM-P Analyzer Software A PC-based tool for pulse and statistical analysis CDMA, TDMA and radar signals

Pulse Analysis Power Pulse Top, Pulse Base, Distal, Mesial, Proximal, Peak, Average, Peak/Average Ratio, Burst Average and Duty Cycle Time and Frequency Rise Time, Fall Time, Pulse Repetition Frequency (PRF), Pulse Repetition Interval (PRI), Pulse Width and Off Time * IEEE pulse definitions and standards for video parameters applied to microwave pulse envelopes ( ANSI/IEEE Std. 194-1977).

Statistical Analysis Statistical Functions Cumulative Distribution Function (CDF) Complementary Cumulative Distribution Function (CCDF) Probability Density CCDF Complete power characterization Helps optimize system design 0.3% For 0.3% of the time, signal power is at or above 8 db peak-to-average ratio 8 db

Agenda Importance of Power Measurements Average, Peak and Pulse Power Power Meter & Sensor Measurement Method Sensor Technologies Agilent Power Measurement Solutions Time-Gated Power Measurements Advanced Power Measurements Measurement Uncertainty, Standards and Traceability Agilent Power Sensor Selection Guides (Appendix)

Sources of Power Measurement Uncertainty Sensor and Source Mismatch Errors Power Sensor Errors Power Meter Errors Sensor Mismatch Meter

Sensor and Source Mismatch Signal Source Impedance Z 0 Power Sensor Power Meter Ideal impedance = Z 0 VSWR

Calculation of Mismatch Uncertainty Signal Source (2 GHz, 0 dbm) Power Sensor E9301A Power Meter VSWR = 1.13 VSWR = 2.0 = 0.33 SOURCE = 0.06 SENSOR = VSWR 1 VSWR 1 Mismatch Uncertainty = ± 2 x x x 100% SOURCE SENSOR = ± 2 x 0.33 x 0. 06 x 100% = ± 3.96%

Power Sensor Uncertainties Various sensor losses P i P gl Element DC Power Meter P r Power Sensor P Cal Factor : K h b = e gl P i (h e = Effective Efficiency) Printed on sensor label (8480 series) Stored in EEPROM (E-series and P-series)

Power Meter Instrumentation Uncertainties Power Reference Uncertainty 0.6 % Instrumentation Uncertainty 0.5 %

What is an Acceptable Measurement Uncertainty? Which is the smaller error: 1.0 db or ± 20%? Answer: 20%! ( 1.0 db is + 26%, 21%) Sensor and meter uncertainties are specified in percentage (linear) and db (log) Marketing Manager s Law of Small Numbers: A small-numbered uncertainty specification sounds better than a large-numbered one.

Calculating Power Measurement Uncertainty 1. Identify significant uncertainties Mismatch uncertainty: ± 3.96% Power linearity: ± 2.0% 1 Cal factor uncertainty: ± 1.8% 1 Power reference uncertainty: ± 0.6% 1 Instrumentation uncertainty: ± 0.5% 1 Specifications apply for an E9301A sensor and Agilent power meter over a temperature range of 25 ±10 degrees C. 2. Combine uncertainties Worst-case or Root Sum of the Squares (RSS) method

Worst-Case Uncertainty Worst-case situation is assumed All sources of error at their extreme values Errors add constructively In our example measurement: 3.96% + 2.0% + 1.8% + 0.6% + 0.5% = ± 8.86% Or, in log terms: + 8.86% = 10 log (1 + 0.089) = + 0.37 db 8.86% = 10 log (1-0.089) = 0.40 db Extremely conservative

RSS (Root Sum of the Squares) Uncertainty* Source of Uncertainty Value (± %) Probability Distribution Divisor Standard Uncertainty u i (k=1) Source/Sensor Mismatch at 2 GHz 3.96 U -shaped 1.414 2.8 Calibration Factor Uncertainty at 2 GHz 2.0 Normal 2 1.0 Linearity at 0 dbm 1.8 Normal 2 0.9 Power Reference Uncertainty 0.6 Normal 2 0.3 Instrumentation Uncertainty 0.5 Normal 2 0.25 Combined Standard Uncertainty = u c = RSS of u i * In accordance to guidelines published in the ISO Guide to the Expression of Uncertainty in Measurement and ANSI/NCSL Z540-2-1996, US Guide to the Expression of Uncertainty in Measurement.

Combined Standard Uncertainty (u c ) In our example: u c 2 2 2 2 2 = (2.8) + (1.0) + (0.9) + (0.3) + (0.25) = 3.13% Expanded uncertainty (k = 2) = k x u c = 6.26% = 10 log (1 + 0.063) = + 0.27 db 10 log (1 0.063) = 0.28 db Worst-case + 0.37 db 0.37 db Agilent AN 1449-3 covers uncertainty calculations

National Standards and Traceability Rising Costs, Better Accuracy Thermistors are used for metrology applications National Reference Standard (Microcalorimeter) Working Standards Measurement Reference Standard Transfer Standard NIST (USA), NPL (UK) NIST (USA), NPL (UK) Commercial Standards Laboratory Manufacturing Facility General Test Equipment User

Summary Accurate power measurements (made with a power meter/sensor combination) are crucial in RF and microwave applications. The three fundamental power measurements are average, peak and pulse. Modern wireless and radar technologies require time-gated and advanced measurements. Agilent provides solutions for basic and advanced measurements. Measurement uncertainty is often calculated using the RSS method. The accuracy of Agilent power sensors is traceable to national standards.

For More Information Agilent Website URL: http://www.agilent.com/find/powermeters Agilent Literature Application Note AN 1449 1, 2, 3 and 4, Fundamentals of RF and Microwave Power Measurements (Parts 1, 2, 3 and 4). Product Note, Choosing the Right Power Meter and Sensor (Lit. No. 5968-7150E). Application Note AN 64-4D, 4 steps for making better power measurements (Lit. No. 5965-8167E)

Appendix: Power Sensor Selection Guides

8480 Series Power Sensors 0 dbm to +44 dbm 8482B 8481B -10 to +35 dbm 8482H 8481H R8486A Q8486A V8486A W8486A -30 to +20 dbm 8482A 8483A (75 Ohm) 8481A 8485A 8487A Opt 033 Q8486D -70 to -20 dbm 8481D 8485D 8487D R8486D Opt 033 110 GHz 75 GHz 50 GHz 40 GHz 33 GHz 26.5 GHz 18 GHz 6 GHz 4.2 GHz 2 GHz 50 MHz 10 MHz 100 khz

E-Series Wide Dynamic Range Sensors -70 to +20 dbm E4413A E4412A H33 CW Only Power Sensors -30 to +44 dbm E9300B E9301B -50 to +30 dbm E9300H E9301H H25 Modulation Average Power Sensors -60 to +20 dbm E9304A E9301A E9300A H18 H24 110 GHz 75 GHz 50 GHz 40 GHz 33 GHz 26.5 GHz 18 GHz 6 GHz 4.2 GHz 2 GHz 50 MHz 10 MHz 9 khz

E-Series E9320 Peak and Average Sensors -65 to +20 dbm E9321A E9325A 300 khz video bandwidth -60 to +20 dbm E9322A E9326A 1.5 MHz video bandwidth -60 to +20 dbm E9323A E9327A 5 MHz video bandwidth 110 GHz 75 GHz 50 GHz 40 GHz 33 GHz 26.5 GHz 18 GHz 6 GHz 4.2 GHz 2 GHz 50 MHz 10 MHz 9 khz

P-Series Wideband Power Sensors 30 MHz video bandwidth -35 to +20 dbm N1921A N1922A 110 GHz 75 GHz 50 GHz 40 GHz 33 GHz 26.5 GHz 18 GHz 6 GHz 4.2 GHz 2 GHz 50 MHz 10 MHz 9 khz

Quiz 1- Power is defined as; a) Energy transferred per unit time b) Amperes per second c) 10 log(v/i) 2- The db (decibel) compares two power levels on what type of scale? a) Linear b) Exponential c) Logarithmic 3- The three basic types of power measurements are: a) Average, Peak-to-Average and Envelope b) Average, Peak and Pulse c) Average, Instantaneous and Pulse

Quiz 4- The output power level of a high-frequency system is: a) More difficult to measure than the voltage along the transmission line b) Typically the most important factor in determining its performance c) Less useful to measure than the output voltage 5- The most accurate instrument for measuring power is: a) A vector signal analyzer b) A power meter/sensor combination c) A spectrum analyzer 6- A power sensor: a) Detects the frequency of the modulating signal b) Can only measure digitally modulated signals c) Converts RF power to a DC or low-frequency signal

Quiz 7- The most widely used types of sensors are: a) Diode detector and thermocouple b) Thermistor and peak power c) Thermocouple and wideband 8- Thermocouple power sensors: a) Can only measure TDMA and CDMA signals b) Can measure all types of signals c) Can only measure CW signals 9- The P-series power meters: a) Are specifically designed for average power measurements b) Provide peak and average power measurements c) Use an innovative two-path design

Quiz 10- The typical dynamic range of 8480 series average power sensors is: a) 90 db b) 30 db c) 50 db 11- Calibration data for individual E-series power sensors is: a) Stored in EEPROM in the sensor b) Downloadable from the Agilent Website c) Printed on the sensor label 12- The 80 db dynamic range of E-series E9300 average power sensors is achieved by the use of: a) Advanced, thin-film thermocouples b) Diode stacks and a two-path design c) A 30 MHz video bandwidth

Quiz 13- Time-gated measurements: a) Require the power sensor to have two measurement paths b) Cannot be used to measure radar signals c) Allow peak and average measurements to be made on a single burst 14- To make time-gated peak power measurements of TDMA-type signals: a) A power meter must have a video bandwidth of at least 100 MHz b) A power sensor must have a built-in reference oscillator c) A power sensor's rise time must be fast enough to follow the rising edge of the signal burst 15- CDMA signals: a) Require statistical power distribution information for complete characterization b) Can be fully characterized by time-gated average power measurements c) Are being superseded by 2G technology

Quiz 16- The EPM-P power meters: a) Should only be used with P-series sensors b) Are designed to measure only TDMA-type signals c) Have high-speed, continuous sampling of the detected power envelope 17- The most significant source of power measurement uncertainty is usually: a) Power sensor inefficiency b) Sensor and source impedance mismatch c) Instrumentation uncertainty 18- The most realistic method for combining measurement uncertainties is: a) The worst-case method b) The U-shaped probability distribution c) The Root Sum of the Squares method

Quiz - Answers 1- a 10- c 2- c 11- a 3- b 12- b 4- b 13- c 5- b 14- c 6- c 15- a 7- a 16- c 8- b 17- b 9- b 18- c