Mineral-insulated resistance thermometers to EN

Similar documents
Screw-in resistance thermometers with terminal head Form B

Screw-in resistance thermometers with plug connector

Resistance thermometers for process technology

Indoor, outdoor and duct resistance thermometers

Resistance Thermometers Model Series TR7X0, Sheathed Design

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

STANDARD RTD's INDEX

Precision Thermistor Sensors

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Product Information Measuring resistor with the Pt100-sensor referring to DIN EN Pt100, Pt500, Pt1000

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

Resistance thermometer Model TR31, miniature design

Electrical Temperature Measurement

Miniature resistance thermometer Model TR33, thread-mounted

Digital conductivity transmitter

Temperature Sensor without thread

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

Resistance thermometer Model TR30, compact design

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

Temperature Sensor with M12 hygienic

Temperature Sensor G1/2" Standard

Temperature Sensor G1/2" Standard

Temperature Sensor with Thread G1/4" FLEXadapt

Temperature Sensor with M12 hygienic

Temperature Sensors Types MBT 5250, MBT 5260 and MBT 5252

PLATINUM SENSORS FOR MEASURING TEMPERATURES UP TO 400 C 28.11a

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

ph or ORP Transmitter

CombiTemp TCR6 Standard RTD temperature sensor

Pharma Temperature Sensor G3/8"

Safe Measurements in High-Voltage Environments CSM GmbH Computer-Systeme-Messtechnik

Temperature and Humidity Probes. Code Max Temp ( C) Resistance 25 C) Accuracy 0 to 70 C)

SAC-3P- 5,0-PUR/M12FR SH

Measuring and Controlling Unit Multronic OC

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Pharma Temperature Sensor G3/8"

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

Long-distance Separate-amplifier Proximity Sensors ES Series Features Detecting distance twice that of conventional

SAC-5P- 1,5-PUR/M12FS SH

VR20 - Inductive sensor (LVDT) Measurement range from 25 to 600 mm

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Valve Island with Electronic I/O

Pharma-Temperature Sensor M12 hygienic

LVDT. Inductive Position Transducer. SL Series. Key-Features:

Measuring and Controlling Unit Multronic

Resistance thermometer Model TR30, compact design

ES Series Features Detecting distance twice that of conventional

Additel 875 Series Dry Well Calibrators

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

SITRANS T measuring instruments for temperature

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

Resistance thermometer Model TR30, compact design

300 ma max. 2 mm ,8 mm. ±1 mm. ±1 Digit. A, A, B, B / signal Z, Z (optional) / status signal ERR (optional) Zinc die casting IP67

RoHS. High shaft load capacity. Shock / vibration resistant

SW 16mm. SW 15mm. SW 19mm

Open Channel Flowmeter 713

TEMPERATURE PROBE. Temperature probe. Handheld instrument. Display / Controller. Logger / EASYBus. Transmitter. Application: NiCr-Ni (Type K)

LVDT. Inductive Position Transducer. SL Series. Key-Features:

Tru products are now under the Tru-Win brand from Winchester Interconnect.

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

TONGFENG FLEXIBLE CONDUIT TONGFENG FLEXIBLE CONDUIT

Signal converter for electromagnetic flowmeters

Electronic Temperature Transmitters

K3D60a ±100N. Description. The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes.

Temperature Sensor for Build-In System G3/8" FLEXadapt

Data sheet. M12 field plug X-coded, straight. Illustrations P/N MNF881A EAN Product specification. Page 1/

Temperature Sensor for Build-In System G3/8" FLEXadapt

400 (±2,5 V/ V/ ,3% V4A

Medium-base Lampholders

Temperature Sensor with G1/2" hygienic

Thermocouples. Table of Contents. Industrial (A-2) Smart Model 1100 (A-26) Smart with Leads Model 1200 (A-27) Wire (A-32)...

Type EXT with cable, probe sold

4.00 ULTRASONIC ANALYZER

Manual Dew point transmitter SP-ESH420 Version: 01/2011/EN

Temperature. Characteristics. Applications

Data sheet. M12 Jack X-coded IP67, field assembly. Illustrations P/N MMF881A315 EAN Product specification. Page 1/

Data sheet C6 A RJ45 field plug pro 360

Data sheet C6 A RJ45 field plug pro

Han High Temp. Description. Design overview. Han High Temp connectors remain robust and reliable for their entire lifespan!

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Sakura Endress RCV-1000/1200. Average Temperature Measuring Element for Tank Gauging System

SRS SEALED ROTARY SENSORS

Relative Humidity & Temperature Transmitters

MWX 2 SERIES. Cable Structure. Flexibility data. Flexible cable assemblies for measuring instruments. Power rating. How to select MWX 0 MWX 0

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Configure-to-Order probes

OPENETICS. P/N E-DAT Industry RJ45 field plug insert Cat.6A. Specialist Manufacturer Voice Data Security.

Series RTD (Resistance Temperature Detector) Code: JT

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

Transcription:

Data Sheet 90.2221 Page 1/6 Mineral-insulated resistance thermometers to EN 60 751 for temperatures from -50 (-200) to +600 C flexible sheath with shock-protected sensor as single or twin resistance thermometer in 2-wire, 3-wire or 4-wire circuit fast response time application-specific fitting length Thanks to their special properties, mineral-insulated resistance thermometers are used in chemical plants, power stations, pipelines, in engine construction, on test beds and in all applications where flexibility and problem-free replacement are required. The low-resistance internal copper conductors are embedded in compressed heat-resistant magnesium oxide inside a flexible thin-walled sheath in stainless steel. The temperature sensor in 2-wire, 3-wire or 4-wire circuit is connected to the internal wires and fitted in the stainless steel protection tube. Protection tube and sheath are welded together. Diameters as small as 1.9mm are available. The excellent heat transfer between the protection tube and the temperature sensor enables short response times (t 0.5 from 0.7sec) and high accuracy. The shock-proof construction ensures a long life. The flexible probe tube permits temperature measurement at points that are difficult to reach. The smallest bending radius is 5 times the external diameter. The measuring insert is normally fitted with a Pt100 temperature sensor to EN 60 751, Class B in 2-wire circuit. Versions with Pt500 or Pt1000 are also available. 3-wire or 4-wire circuit connections can be provided. Technical data Terminal head Connection Connecting cable Form J, aluminium die-casting, Pg9, IP54, ambient temperature -20 to +100 C Caution: reduced ambient temperature when using transmitters (see Data Sheet 90.2603) cable ends available as: bare wires, with ferrules, receptacles or multipole connector silicone, ambient temperature -50 to +180 C Teflon, ambient temperature -190 to +260 C metal braiding, ambient temperature -50 to +350 C Process connection thread, stainless steel 1.4571 Protection tube stainless steel 1.4541, 1.9mm, 3mm and 6mm dia. Measuring insert Pt100 temperature sensor, EN 60 751, Cl. B, 2-wire circuit Response times in water with 0.4m/sec / in air with 3m/sec 1.9mm dia.: water t 0.5 = 0.7sec, t 0.9 = 2.1sec / air t 0.5 = 7.2sec, t 0.9 = 20.5sec 3.0mm dia.: water t 0.5 = 1.3sec, t 0.9 = 4.0sec / air t 0.5 = 13.5sec, t 0.9 = 41.0sec 6.0mm dia.: water t 0.5 = 5.0sec, t 0.9 =11.5sec / air t 0.5 = 37.5sec, t 0.9 = 117.5sec Transmitter analog transmitter Type 902603/10, see Data Sheet 90.2603

Data Sheet 90.2221 Page 2/6 Dimensions Type 902221/10 Type 902221/20 Type 90/1221/3x Type 902221/40

Data Sheet 90.2221 Page 3/6 Order details: s to EN 60 751 (1) Basic version 902221/10 with bare connecting wires 902221/20 with Lemosa connector (2) Operating temperature in C x x 150-200 to +600 C x x 415-50 to +600 C (standard) (3) Measuring insert x x 1001 1 x Pt100 in 3-wire circuit x x 1003 1 x Pt100 in 2-wire circuit x x 1005 1 x Pt1000 in 2-wire circuit (only for -50 to +600 C) x x 1006 1 x Pt1000 in 3-wire circuit (only for -50 to +600 C) x x 1011 1 x Pt100 in 4-wire circuit x 2001 2 x Pt100 in 3-wire circuit (only in conjunction with D 6mm) x x 2003 2 x Pt100 in 2-wire circuit (4) Tolerance class to EN 60 751 x x 1 Class B (standard) x x 2 Class A x x 3 Class 1/3 DIN (5) Protection tube diameter D in mm x x 1.9 1.9mm, with Type 902221/20 incl. Lemosa connector Size 0 (sheath 1.5mm dia.) x x 3 3.0mm, with Type 902221/20 incl. Lemosa connector Size 0 x x 6 6.0mm, with Type 902221/20 incl. Lemosa connector Size 2 (6) Fitting length EL in mm (70 EL 1000) x x 100 100mm x x 200 200mm x x 300 300mm x x... please specify in plain text (50mm steps) (1) (2) (3) (4) (5) (6) Order code - - - - - Order example 902221/20-415 - 1001-1 - 6-200

Data Sheet 90.2221 Page 4/6 Order details: s to EN 60 751 (1) Basic version 902221/30 with PVC cable (cable temp. range -5 to +80 (+105 C) 902221/32 with silicone cable (cable temp. range -50 to +180 C) 902221/33 with Teflon cable (PTFE) (cable temp. range -190 to +260 C) 902221/34 with metal-braided cable (cable temp. range -50 to +350 C) (2) Operating temperature in C x x x x 150-200 to +600 C x x x x 415-50 to +600 C (standard) (3) Measuring insert x x x x 1001 1 x Pt100 in 3-wire circuit x x x x 1003 1 x Pt100 in 2-wire circuit x x x x 1005 1 x Pt1000 in 2-wire circuit (only for -50 to +600 C) x x x x 1006 1 x Pt1000 in 3-wire circuit (only for -50 to +600 C) x x x x 1011 1 x Pt100 in 4-wire circuit x x x 2001 2 x Pt100 in 3-wire circuit (only in conjunction with D 6mm) x x x x 2003 2 x Pt100 in 2-wire circuit (4) Tolerance class to EN 60 751 x x x x 1 Class B (standard) x x x x 2 Class A x x x x 3 Class 1/3 DIN (5) Protection tube diameter D in mm x x x x 1.9 1.9mm (sheath 1.5mm dia.) x x x x 3 3mm x x x x 6 6mm (6) Fitting length EL in mm (70 EL 1000) x x x x 100 100mm x x x x 200 200mm x x x x 300 300mm x x x x... please specify in plain text (50mm steps) (7) Connecting cable end x x x x 03 bare cable ends x x x x 11 ferrules to DIN 46 228 Part 4 (standard) x x x x 13 receptacle 6.3 to DIN 46 247 x x x x 80 multipole connector (please specify type in plain text) (8) Connecting cable length AL in mm (500 AL 500000) x x x x 2500 2500mm x x x x... please specify in plain text (500mm steps) (9) Extra codes x x x x 000 no extra code x x x x 317 shielded connecting cable (1) (2) (3) (4) (5) (6) (7) (8) (9) Order code - - - - - - - /,... Order example 902221/32-415 - 1001-1 - 3-200 - 11-2500 / 000 1 1. List extra codes in sequence, separated by commas.

Data Sheet 90.2221 Page 5/6 Order details: s to EN 60 751 (1) Basic version 902221/40 with terminal head Form J (2) Operating temperature in C x 150-200 to +600 C x 415-50 to +600 C (standard) (3) Measuring insert x 1001 1 x Pt100 in 3-wire circuit x 1003 1 x Pt100 in 2-wire circuit x 1005 1 x Pt1000 in 2-wire circuit (only for -50 to +600 C) x 1006 1 x Pt1000 in 3-wire circuit (only for -50 to +600 C) x 1011 1 x Pt100 in 4-wire circuit x 2003 2 x Pt100 in 2-wire circuit (4) Tolerance class to EN 60 751 x 1 Class B (standard) x 2 Class A x 3 Class 1/3 DIN (5) Protection tube diameter D in mm x 3 3mm x 6 6mm (6) Fitting length EL in mm (100 EL 10000) x 100 100mm x 200 200mm x 300 300mm x... please specify in plain text (50mm steps) (7) Process connection x 104 thread 1/2" pipe x 105 thread 3/4" pipe (8) Extra codes x 000 no extra code x 330 1 x analog transmitter Type 902603/10 (please specify range in plain text) (1) (2) (3) (4) (5) (6) (7) (8) Order code - - - - - - /,... Order example 902221/40-415 - 1001-1 - 6-100 - 104 / 000 1 1. List extra codes in sequence, separated by commas. Stock versions: (1) (2) (3) (4) (5) (6) Sales No. - - - - - 902221/20-150 - 1003-1 - 1.9-300 90/00066527 902221/20-415 - 1011-1 - 3-300 90/00055770 902221/20-415 - 1011-1 - 6-300 90/00055773 Stock versions: (1) (2) (3) (4) (5) (6) (7) (8) (9) Sales No. - - - - - - - / 902221/32-150 - 1011-1 - 1.9-300 - 11-2500 / 000 90/00066531 902221/32-415 - 1003-1 - 3-100 - 11-2500 / 000 90/00068243 902221/32-415 - 1003-1 - 3-200 - 11-2500 / 000 90/00068244 902221/32-415 - 1003-1 - 3-300 - 11-2500 / 000 90/00055763 902221/32-415 - 1001-1 - 3-100 - 11-2500 / 000 90/00068247 902221/32-415 - 1001-1 - 3-300 - 11-2500 / 000 90/00055764 902221/32-415 - 1001-1 - 3-500 - 11-2500 / 000 90/00068248 902221/32-415 - 2003-1 - 3-300 - 11-2500 / 000 90/00055765 902221/32-415 - 1001-1 - 6-300 - 11-2500 / 000 90/00055767 902221/32-415 - 1001-1 - 6-500 - 11-2500 / 000 90/00068250

Data Sheet 90.2221 Page 6/6 Stock versions: (1) (2) (3) (4) (5) (6) (7) (8) Sales No. - - - - - - / 902221/40-415 - 1003-1 - 3-100 - 104 / 000 90/00066731 902221/40-415 - 1003-1 - 3-200 - 104 / 000 90/00066732 902221/40-415 - 1003-1 - 3-300 - 104 / 000 90/00057512 902221/40-415 - 1003-1 - 6-200 - 104 / 000 90/00068252 902221/40-415 - 1003-1 - 6-300 - 104 / 000 90/00055775 902221/40-415 - 1011-1 - 6-300 - 104 / 000 90/00055776 902221/40-415 - 2003-1 - 6-300 - 104 / 000 90/00055777