PROFIBUS HUB REPEATER

Similar documents
AUG / 99 P S I P M E

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

Mini PROFIBUS Repeater PFB-R User's Manual FOURSTAR Electronic Technology Co., Ltd. Deyang China All Right Reserved

WARNING Improper operation may result in serious personal injury CAUTION

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

Thank you for purchasing S100 Profibus-DP Communication Module SAFETY PRECAUTIONS

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

ADA User manual ADA Multimode Fibre-Optic to Current Loop Converter

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

WIRELESS MODBUS GATEWAY WGW410

ICF-1280I Series Quick Installation Guide

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio

CAN Repeater. CRep S4.../S24/RMD. User Manual. Thomas Wünsche

IF30. User's manual. Description. Table of contents IF30

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301)

JBUS/MODBUS communication card

USER S MANUAL PULSE INPUTS MODULE WITH PROVER SUPPORT

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

MEGAPLEX-2100 MODULE VC-16A. 16-Channel PCM/ADPCM Voice Module Installation and Operation Manual. Notice

The I-2532 CAN to Fiber Converter

H LONTalk Integration Node For Use With H704 and H663 Branch Current Monitors (BCM) H NOTICE DANGER INSTALLATION GUIDE DIMENSIONS

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

RSMFX-2R MULTIFUNCTIONAL

Analog Module D1-15P User Manual

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

JBus/Modbus Communication Card

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

The i-7531 CAN Repeater

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

System Components Liquiphant M (NAMUR)/PROFIBUS-PA interface FXA 164

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Motorised unit Changeover switch installation and operation guide. Ref. 4257Z001 Rev. 05

PRetrans Table of contents

Data Acquisition Modules/ Distributed IO Modules

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

ioselect Z-NET Z-4RTD 4 Channel RTD Input Module

FR50MxxR. DC-50 RedLink Fiber Optic Receiver Datasheet DESCRIPTION FEATURES AVAILABLE OPTIONS APPLICATIONS

satech SynchroStar GPS 200 Series

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

RS-232 Electrical Specifications and a Typical Connection

Fieldbus Isolating Repeater Series 9185/11

MINI MCR-SL-UI-f(-SP)

TD_CAN Transceiver Modules Application Guide 2017

MULTIPLE OUTPUT DIGITAL DELAY

900 MHz. Frequency Hopping RS-485 Master/Slave auto-sensing radio interface.

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

High precision measurement system for current and voltage IHC-A/B-RM01/03

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

Modbus communication module for TCX2: AEX-MOD

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

DA 30 High Torque Technical Specification

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support

KNX Powerline PL 110. KNX Association

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Answering frequently asked Questions (Firmware V.107)

3TK28 Safety Relays. General data. 7/70 Siemens LV

Technical Manual TRANSDUCER AMPLIFIER TYPE DR7AC. Doc. Ref CD2402K

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Installation Guide Multi Position Servo Controller E1100-MP and E1100-MP-HC

240 Series. Cryogenic Temperature Sensor Input Modules. 240 Series modules are the ideal companion to Cernox

Introduction. Protocol Definitions. The RS-485 Standard. APPLICATION NOTE 3884 How Far and How Fast Can You Go with RS-485?

Technical description MT24. User manual WARNING GENERAL INSTRUCTIONS GENERAL DESCRIPTION

DAA AES/EBU Digital Audio Distribution Amplifier. User Manual. I.R.T. Communications Pty Ltd

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

A53106 SERIES DC-TO-DC CONVERTER

Transmitter System USER S MANUAL. Light Series

FR50MxxR DC-50 RedLink Fiber Optic Receiver Datasheet

Instruction manual for STA 1 sectional door operator

FAQ Frequently Asked Questions

AcuMesh Wireless RS485 Network. User's Manual SOLUTION

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Z170REG. Universal converter module with galvanic insulation between 2 analog outputs

The wireless alternative to expensive cabling...

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Wireless Base Radio. Wireless Transmitters

INSTALLATION MANUAL. SENECA s.r.l. Via Germania, Z.I. CAMIN PADOVA ITALY Tel Fax

INSTALLATION AND OPERATION MANUAL

Safety Information (Attach ed at the upper cover of t his product) Safety Warning (Attached on the output fiber isolato r & collimator) Figure 1 Laser

MIRAGE BD-35 DUAL BAND POWER AMPLIFIER

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

SFIBER Fibre-optic Option Card for Lon Star Coupler RER 111. Technical Reference Manual

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.

MV110-8AS. Analog input module 8 channel. User guide

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

Positioning drives DC motor, brushless Absolute multiturn position detection, Profibus-DP

MD-5060 DIGITAL MEGOHMMETER

Transcription:

USER S MANUAL PROFIBUS HUB REPEATER RHP303 R H P 3 0 3 M E

smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: www.smar.com/contactus.asp

RHP303 Profibus Hub Repeater AVOIDING ELECTROSTATIC DISCHARGES ATTENTION Electrostatic discharges may damage semiconductor electronic components in printed circuit boards. They usually occur when touching components or connector pins from modules and racks, without wearing the appropriate equipment to prevent discharges. It is recommended to take the following precautions: Before handling modules and racks, remove the electrostatic charge from your body by wearing a proper wristband or touching grounded devices; Avoid touching electronic components or connector pins from racks and modules. NOTE To ensure that our products are safe and without risk to health, read the manual carefully prior to installation. Installation, operation, maintenance and repair should only be performed by trained personnel and according to the User Manual. Updated information about the Smar products can be obtained directly on http://www.smar.com 3

RHP303 Profibus Hub Repeater Description RHP303 PROFIBUS HUB REPEATER RHP303 is an active element serving as interface between segments on Profibus network and ensures adequate signal levels, while guarantees the communication signal integrity. The repeater prevents signal deterioration in long distances. Essentially it receives the signal from a network segment, cleans, amplifies and transmits it to other segments. This way, the original message is preserved for all network segments. The RHP303 executes this function bidirectionally. In addition, serves to galvanically isolate the segments. The PROFIBUS DP is a high speed communication bus that follows strict spur lines rules due to possible reflections that disturb communications. The RHP303 is the innovative solution for applications that need spur lines or star segments. It is the most economical solution to install reliable spur lines on high speed DP networks. It has 5 insulated galvanic transparent repeaters, allowing network structures with extended spur lines, which, individually, may include up to 31 devices and a length equal to the main bus. The RHP303 regenerates the electric signal in one channel and transfers it to all the others (chicken foot topology). As RHP303 creates insulated segments, the devices can be removed and inserted during the operation. Likewise, electric bus problems and EMC disturbances on a spur do not spread to other segments. The RHP303 smart circuits and its insulation do not electrically modify the communication signal. These circuits also identify automatically the transmission speed. The RHP303 has a differential feature that is to work in Modbus for two communication rates in manual mode: 9.6 Kbps and 19.2 Kbps. To help installation, a terminator is integrated and can be turned on or off. The RHP303 is powered by 12 to 30Vdc voltage. For faults identification, maintenance and commission, it has LEDs that indicate each channel status. Main features IP 20 classification; 5 insulated channels; Transparent for all PROFIBUS DP protocol versions; RS-485 specifications for each channel; Maximum 12 Mbps communication rate; Supports up to 31 devices per channel; Supports up to 1200 m length of spur line; No address required; Integrated terminator; Supports Modbus protocol in manual mode on 9.6 Kbps and 19.2 Kbps; Insertion and removal of slave equipment during the operation; Protection against short circuit and indication on each channel; Compact and robust construction; Status and error display per channel; Compatible with all DP cables; Provides more convenient arrangement for the network cables; Easily extensible installations; DB9 connector available for diagnostics; Cost savings with cabling and repeaters. IMPORTANT This equipment must only be used with devices or components complying with PROFIBUS and RS-485 standards. This product can only work correctly and safely if transported, stored, adjusted, installed, operated and revised according to recommendations. 4

RHP303 User s Manual Figure 1 RHP303 Areas of Application Dynamic spur lines for actuators, flow meters and ph analyzers; Inverters and motors; Motor control centers; Barrier for galvanic and non-insulated equipment; Large star/tree structured networks. Examples of Application The figure below shows a general RHP303 application. Each insulated channel prevents short circuit propagation from one channel to another and allows expansion of up to 1200m per segment. Figure 2 General application Profibus DP networks can be expanded in tree or star topology, without limits for RHP303 in cascade. See the next figure. 5

RHP303 Profibus Hub Repeater Figure 3 Expansion of Profibus DP networks The RHP303 increases the network availability by filtering EMI noises so that one channel does not interfere with the other or with the main trunk. Figure 4 Insulation between areas PROFIBUS DP cable lengths See on the table below the relation between the several communication rates and the allowed lengths. Make sure the cables on the main channel (A) and the derived channels (B to F) comply with the PROFIBUS DP cable specifications for the RS-485. Baud rate (kbps) 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Segment length (m) 1200 1200 1200 1200 1000 400 200 100 100 100 Segment length (feet) 3940 3940 3940 3940 3280 1310 656 328 328 328 6

RHP303 User s Manual Baud Rate LEDs The BD0 to BD9 LEDs blink in yellow to indicate the baud rate used by the Profibus DP Repeater according to the next figure. The baud rate will be the same for every channel. Figure 5 BD0 to BD9 LEDs to indicate the communication rate Baudrate LEDS BDO BD1 BD2 BD3 BD4 BD5 BD6 BD7 BD8 BD9 9,6 Kbps ON off off off off off off off off off 19,2 Kbps off ON off off off off off off off off 45,45 Kbps off off ON off off off off off off off 93,75 Kbps off off off ON off off off off off off 187,5 Kbps off off off off ON off off off off off 500 Kbps off off off off off ON off off off off 1,5 Mbps off off off off off off ON off off off 3,0 Mbps off off off off off off off ON off off 6,0 Mbps off off off off off off off off ON off 12 Mbps off off off off off off off off off ON Status LEDs (ST) Each Profibus DP Repeater channel has a ST LED. The red ST LED indicates the channel status. If the LED is off, the channel is good. If it is on, the channel has some fault. It can be caused by a cable short circuit or any other problem that may degrade the signal until it is no longer recognized by the RHP303. Channel Status Good Faulty ST LED Off On 7

RHP303 Profibus Hub Repeater Figure 6 ST LEDs to indicate the channel status RX LEDs Each Profibus DP Repeater channel has a RX LED. The yellow RX LED indicates the reception by the channel. When turned off, the channel is not receiving a valid signal. When turned on, the channel is receiving a valid signal. Reception Invalid or non-existing signal Receiving a valid signal RX LED Off On Figure 7 RX LEDs to indicate signal reception Installation The RHP303 can be installed anywhere in a non-hazardous area and on the specified temperature range of 0 to 60ºC. The RHP303 must be installed on DIN rail, with the connector cable on the bottom part. In this position the cables go down and it is also easier to read the status LEDs. 8

RHP303 User s Manual Figure 8 RHP303 installed on a DIN rail NOTE The installation must be executed by qualified technicians with a PROFIBUS Installer or a PROFIBUS Engineer certificate. Power supply The power supply connector, a 3-pin terminal block, is located on the RHP303 lower left corner. The power supply must comply with the Technical Specifications topic. Figure 9 Detail of the power supply connector Spur segments Connect the spur segments on the channel B, C, D, E and F connectors, according to the table below. Pin B (+) A (-) REF SHD Signal Positive Negative GND Shield 9

RHP303 Profibus Hub Repeater Figure 10 Detail of spur segment connectors Terminators All RHP303 channels have configurable terminators. The main channel termination is adjusted in OFF by default. If the RHP303 is the last or the first segment device, the termination must be adjusted in ON. The termination of the other channels is adjusted in ON by default because the new segment is expected to be initiated on the RHP303. Do not forget to turn on the switch at the other segment end. NOTE Non-used channels must have their terminators activated. Figure 11 Detail of channel terminators position Baud Rate Configuration The RHP303 recognizes the transmission speed by default. If necessary lock the RHP303 on given transmission speeds, the SW1.1 to SW1.5 must be adjusted on the required value. To execute the adjustment remove the top cover. 10 Figure 12 Switches SW1.1 to SW1.5 for communication rate adjustment The switches SW1.1 to SW1.5 are used to select the baud rate used by the Profibus DP Repeater according to the next table. The baud rate selected will be the same for all channels. These baud rates are standardized by the Profibus DP protocol.

RHP303 User s Manual MANUAL BAUD RATE SW1.1 SW1.2 SW1.3 SW1.4 SW1.5 SW1.6 SW1.7 SW1.8 AUTO OFF X X X X X X X 9.6 Kbps ON ON OFF OFF OFF X X X 19.2 Kbps ON OFF ON OFF OFF X X X 45.45 Kbps ON ON ON OFF OFF X X X 93.75 Kbps ON OFF OFF ON OFF X X X 187.5 Kbps ON ON OFF ON OFF X X X 500 Kbps ON OFF ON ON OFF X X X 1.5 Mbps ON ON ON ON OFF X X X 3.0 Mbps ON OFF OFF OFF ON X X X 6.0 Mbps ON ON OFF OFF ON X X X 12 Mbps ON OFF ON OFF ON X X X Note: The X on the table means The switch position is irrelevant. To adjust the transmission speed, use a screwdriver. NOTE For the Modbus protocol, the available rates must be adjusted in Manual : 9.6 Kbps and 19.2 Kbps. Technical Specifications POWER SUPPLY Power connector 3-pin terminal block Voltage 12 to 30 Vdc (24 Vdc nominal) Maximum current 270 ma @ 24 Vdc Protection against reverse polarity Yes Cabling < 2.5 mm 2 FUNCTION SPECIFICATIONS Supported Protocols Modbus, DP-V0, DP- V1, DP-V2, FDL, MPI, FMS, PROFIsafe, PROFIdrive and any other FDL-based protocol Communication Rates (kbps) 9.6; 19.2; 45.45; 93.75; 187.5; 500; 1500; 3000; 6000 and 12000 Communication Rate detection Self-detectable by default or switch configurable Communication rate selection switch 0 = Self-detectable by default Communication rate detection time < 5 s (if self-detection selected) Data delay time 1 Tbit for all rates Jitter delay time ±0.1 Tbit for all rates Terminators One on each spur ENVIRONMENT CONDITIONS Operation temperature 0 to 60 ºC Protection degree IP 20 Dimensions (LxWxH) Weight Support DIMENSIONS AND WEIGHT 296 x 125.4 x 65 mm 612 g MOUNTING DIN rail 11

RHP303 Profibus Hub Repeater Spare part components SPARE COMPONENTS LIST COMPONENTS DESCRIPTION CÓDE 5 x 20 mm Fuse 500 ma (package with 10 pieces) 400-1241 Dimensional Drawings The sizes are in millimeters and in brackets for inches. 65 (2.55) 138 (5.43) 138 (5.43) 296 (11.65) CH A CH B CH C CH D CH E CH F 12

RHP303 User s Manual 13

RHP303 Profibus Hub Repeater 14

Appendix SRF SERVICE REQUEST FORM RHP303 Profibus Hub Repeater COMPANY INFORMATION Proposal Nº: Company: Unit: Invoice: COMMERCIAL CONTACT Full Name: Phone: Fax: E-mail: TECHNICAL CONTACT Full Name: Phone: Extension: E-mail: Model: EQUIPMENT DATA Serial Number: PROCESS DATA Process Type (Ex. boiler control): Operation Time: Failure Date: FAILURE DESCRIPTON (Please, describe the failure. Can the error be reproduced? Is it repetitive?) OBSERVATIONS USER INFORMATION Company: Contact: Section: Title: Signature: Phone: Extension: E-mail: Date: / / For warranty or non-warranty repair, please contact your representative. Further information about address and contacts can be found on www.smar.com/contactus.asp A.1

RHP303 Profibus Hub Repeater A.2