Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

Similar documents
G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

SPST-NO SPDT DPST-NO DPDT

CV : 16 A, pinning 5 mm,: switching at 105 C 6. Market Code None : General purpose HA : Home Appliance according to IEC/EN

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Classification Enclosure rating Contact form Contact material

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

3. Contact Form A: SPST-NO

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

G8P. PCB Power Relay. Model Number Legend. Application Examples. Ordering Information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

SPST-NO SPDT DPST-NO DPDT

G2RL-1A G2RL-1 G2RL-2A G2RL-2

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

G5LE. Ordering Information. PCB Relay. A Cubic, Single-pole 10-A Power Relay J MODEL NUMBER LEGEND G5LE PCB Relay G5LE

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

Contact Ag + Au-clad AgPd + Au-clad. General purpose DPDT G6AU-274P-ST-US G6AU-234P-ST-US 4PDT G6AU-474P-ST-US G6AU-434P-ST-US

Suitable for lighting and motor load, 1 Form A 50A latching relays

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Compact Relay Family with Forcibly Guided Contacts

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Surface-mounting Relay

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

1a/1c/2a/2c/5A/10A power relays for power supply

Model Number Structure

1a 16A power relay for micro wave oven

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

Safety Monitoring Relays

4. Special Function 2 V: 8-GHz band High-speed differential transmission

Features. UL Insulation. Sealed type washable 1A (SPNO) H H-1A-C 845H-1A-V 845H-1A-S. system approval Flux tight Sealed type

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

MY-GS CSM_MY-GS_DS_E_2_1

Ordering Information. Ratchet Relay G4Q. Model Number Legend

Song Chuan / Relay Catalog 507

Details on the New G2RS

G6K(U)-2F(P)-RF(-S, -T)

Compliant with European standards 1a/1c 6A Slim power relays

OMRON MK-I / -S RELAY

Micro-ISO Automotive Relay. (Unit: mm inch)

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

General-purpose Relay

Model Number Structure

CSM_G7S-_-E_DS_E_7_1

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

Model Number Structure

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

Load for air conditioner 1a 20A power relays

1a/1c 5A/10A small power relays

30 A rated contacts Flange mount Faston 250 connections. 30 A rated contacts PCB mount - bifurcated terminals. Copper side view

Ratings Ratings SPST-NO SPDT DPST-NO DPDT

The highest class load current of MOS FET Relays realized with DIP8 package

1a/1c/2a/2c/5A/10A power relays for power supply

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Solid-state Timer H3DS

Test & Measurement equipment Power circuit. 2. Contact form 1 : 1a (SPST-NO) terminals 40 : 400 V. 4. Additional functions R: Low ON resistance

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:

507-1A H - - C. Features. Type List. Ordering Information

Characteristic impedance

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Class Sealing Fully sealed Contact configuration Rated coil voltage Model Basic Type SPDT 4.5 VDC G6Y-1 5 VDC 9 VDC 12 VDC 24 VDC

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

Compact Flat Size Relay for Automotive. (Unit: mm inch)

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

PCB Footprint Max.Load Coil Voltage Non-Latching part number Single-coil latching part number Standard ground terminal (1GHz)

Features. Designation (provided with) style. Contact. Insulation. system. gap. 110A-1AH-F-C 110BA-1AH-F-C 110A-1AH1-F-C 110BA-1AH1-F-C High power type

Features. Insulation system F 835-1A-F-C 835-1A-F-S L-1A-C 835L-1A-S F 835L-1A-F-C 835L-1A-F-S NL-1A-C 835NL-1A-S

Safety Relay Unit. OFF-delay time

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Tactile Switch. Ordering Information. A Wide Range of Models: 6 6 mm, mm, Side-operated, High-force, and Gold-plated.

General-purpose Relay

Security equipment Industrial equipment Power circuit. 2. Contact form 1: 1a (SPST-NO) 3: 1b (SPST-NC)

MICRO-ISO AUTOMOTIVE RELAY

16A POWER RELAY FOR MICRO WAVE OVEN

A rated contacts PCB mount - bifurcated terminals. Copper side view

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

Solid-state Twin Timer

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

A rated contacts Flange mount/faston 250 (6.3 x 0.8 mm) connection

Transcription:

ow-profile Relay with Various Models ow profile:.7 mm in height. Creepage distance 8mm between coil and contacts 0 kv Impulse withstand voltage Models with AC coil available. High-Inrush model available (Inrush peak currents up to 00 A) ow Noise models available (Approx. 0 to db less sound pressure than standard -Series Relays) TV8 Rating models available (TV8 for U standard) RoHS Compliant Model Number egend Application Examples -@@-@-@ 2 3 4. Number of poles : -pole 3. Classification None: Standard E : Housing equipments Audio-visual products Office automation machines Air-conditioners ighting 2. Contact Form None: SPDT (c) A : SPST-NO (a) 4. Additional Models None: Standard HR: High-inrush N: ow Noise TV8: TV8 rating Ordering Information Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage Standard -A-N VDC, 2VDC, 24VDC SPST-NO (a) -A-E-HR VDC, 2VDC, 24VDC, 48VDC -A-E-N VDC, 2VDC, 24VDC PCB terminals Flux protection -A-E-TV8 VDC, 2VDC, 24VDC, 48VDC 24VAC, 00VAC, VAC/VAC, --E SPDT (c) 0VAC, 230VAC/240VAC --E-HR VDC, 2VDC, 24VDC, 48VDC Note. When ordering, add the rated coil voltage to the model number. Example: -A-N DC Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. Minimum packing unit 00 pcs/tray Ratings Coil ow Noise Models: -A(-E)-N Rated Voltage (VDC) Coil resistance (Ω) 06 47.2 2 44.2 272 24 22.,086 Must operate voltage Must release voltage % of rated voltage Note. The rated current and resistance are measured at a coil temperature of 23 C with a tolerance of ±0%. Max voltage Power consumption (mw) 70% max. 0% min. 0% Approx. 30

High-Inrush Models: -(A)-E-HR, -A-E-TV8 Rated Voltage (VDC) Note. The rated current and resistance are measured at a coil temperature of 23 C with a tolerance of ±0%. Models with AC Coil: --E Coil resistance (Ω) 80 62. 2 33.3 360 24 6.7,440 Must operate voltage Must release voltage % of rated voltage Max. voltage 70% max. 0% min. 30% Power consumption (mw) Approx. 400 48 8.96,38 Approx. 430 Rated Voltage (VAC) at 0Hz Note. The rated current tolerance is +%/-%. All above data is based on coil temperature of 23 C. 2. Coil resistances are provided as reference values. Contacts ow Noise Models: -A(-E)-N High-Inrush Models: -(A)-E-HR, -A-E-TV8 Models with AC Coil: --E at 60Hz Coil resistance (Ω) 24 3.3 28.3 443 00 7. 6.88 8,2 /.8/6.2.3/.70,600 0 3.7 3.4 33,000 230/240 3.00/3.3 2.76/2.88 47,600 Must operate voltage Must release voltage % of rated voltage Max. voltage Power consumption (mw) 7% max. % min. 0% Approx. 70 oad Resistive load Standard Contact form SPST-NO (a) Contact Type Single Contact material Ag Alloy Rated load 2 A at 20 VAC 6 A at 20 VAC 2 A at 24 VDC 6 A at 24 VDC Rated carry current 2 A 6 A Max. switching voltage 20 VAC, 24 VDC Max. switching current 2 A 6 A oad Resistive load Contact form SPST-NO (a) SPDT (c) Contact Type Single Contact material Ag Alloy Rated load 6 A at 20 VAC 6 A at 20 VAC, 24VDC (NO) 6 A at 24 VDC A at 20 VAC, 24 VDC (NC) Rated carry current 6 A 6 A (NO), A (NC) Max. switching voltage 20 VAC, 24 VDC Max. switching current 6 A 6 A (NO), A (NC) oad Contact form Contact Type Contact material Rated load Rated carry current Max. switching voltage Max. switching current Resistive load SPDT (c) Single Ag Alloy 6 A at 20 VAC, 24 VDC (NO) A at 20 VAC, 24 VDC (NC) 6 A (NO), A (NC) 20 VAC, 24 VDC 6 A (NO), A (NC) 2

Characteristics ow Noise Models: -A(-E)-N Item Classification Standard Contact resistance 00 mω max. Operate time ms max. Release time ms max. Insulation resistance,000 MΩ min. Dielectric strength Between coil and contacts 6,000 VAC, 0/60 Hz for min Between contacts of the same polarity,000 VAC, 0/60 Hz for min Impulse withstand voltage Between coil and contacts 0 kv (.2 0 μs) Insulation distance Between coil and contacts Clearance: 8 mm, Creepage: 8 mm Vibration resistance Destruction 0 to to 0 Hz, 0.7 mm single amplitude (. mm double amplitude) Malfunction 0 to to 0 Hz, 0.7 mm single amplitude (. mm double amplitude) Shock resistance Destruction,000 m/s 2 Malfunction 00 m/s 2 Durability Mechanical,000,000 operation min. (at 8,000 operations/hr) Electrical 0,000 operations min. (at,800 operations/hr) 0,000 operations min. (at,800 operations/hr) Failure rate (P level) (reference ) 00 ma at VDC Ambient operating temperature -40 to 8 C (with no icing or condensation) Ambient operating humidity % to 8% Weight Approx. 0 g Note. Values in the above table are initial values. 2. The contact resistance is measured with A applied at VDC using a fall-of-potential method. 3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 00 VDC. 4. The release time is value with a diode attached.. Failure rate (P level) was measured at a switching frequency of operations/min. High-Inrush Models: -(A)-E-HR, -A-E-TV8 Item Classification Contact resistance 00 mω max. Operate time ms max. Release time ms max. Insulation resistance,000 MΩ min. (at 00 VDC) Dielectric strength Between coil and contacts 6,000 VAC, 0/60 Hz for min Between contacts of the same polarity,000 VAC, 0/60 Hz for min Impulse withstand voltage Between coil and contacts 0 kv (.2 0 μs) Insulation distance Between coil and contacts Clearance: 8 mm, Creepage: 8 mm Vibration resistance Destruction 0 to to 0 Hz, 0.7 mm single amplitude (. mm double amplitude) Malfunction 0 to to 0 Hz, 0.7 mm single amplitude (. mm double amplitude) Shock resistance Destruction,000 m/s 2 Malfunction 00 m/s 2 Durability Mechanical 0,000,000 operation min. (at 8,000 operations/hr) Electrical 0,000 operations min. (at,800 operations/hr) Failure rate (P level) (reference ) 00 ma at VDC Ambient operating temperature -40 to 8 C (with no icing or condensation) Ambient operating humidity % to 8% Weight Approx. 0 g Note. Values in the above table are initial values. 2. The contact resistance is measured with A applied at VDC using voltage drop method. 3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 00 VDC. 4. The resistive load ratings for NO contact apply when there is no load on NC contact.. Failure rate (P level) was measured at a switching frequency of operations/min. Models with AC Coil: --E Item Classification Contact resistance 00 mω max. Operate time ms max. Release time ms max. Insulation resistance,000 MΩ min. (at 00 VDC) Dielectric strength Between coil and contacts 6,000 VAC, 0/60 Hz for min Between contacts of the same polarity,000 VAC, 0/60 Hz for min Impulse withstand voltage Between coil and contacts 0 kv (.2 0 μs) Insulation distance Between coil and contacts Clearance: 8 mm, Creepage: 8 mm Vibration resistance Destruction 0 to to 0 Hz, 0.7 mm single amplitude (. mm double amplitude) Malfunction 0 to to 0 Hz, 0.7 mm single amplitude (. mm double amplitude) Shock resistance Destruction,000 m/s 2 Malfunction 00 m/s 2 Durability Mechanical 0,000,000 operation min. (at 8,000 operations/hr) Electrical 0,000 operations min. (at 7 operations/hr) Failure rate (P level) (reference ) 40 ma at 24 VDC Ambient operating temperature -40 to 70 C (with no icing or condensation) Ambient operating humidity % to 8% Weight Approx. 0 g Note. Values in the above table are initial values. 2. The contact resistance is measured with A applied at VDC using voltage drop method. 3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 00 VDC. 4. The resistive load ratings for NO contact apply when there is no load on NC contact.. Failure rate (P level) was measured at a switching frequency of operations/min. 3

Engineering Data ow Noise Models: -A(-E)-N Maximum Switching Capacity Durability Switching current (A) 00 0 -A-E-N Durability (x0 4 operations) 0000 000 00 20 VAC resistive load -A-N 0 0 00 000 Switching voltage Distribution of Sound Pressure. When Operating 2. When Releasing Quantity 0 40 30 Quantity 0 2 4 6 8 0 2 4 6 8 0 40 30 Switching current (A) Sample: -A-N 2 VDC Number of relays: 00 pcs Range:A weighted sound pressure level, Fast, Max. hold Device connected to coil: Diode Testing environment:room temperature and humidity Background noise: Approx. 30 db max. Relay cm 0 0 Sponge Microphone 0 ~36 ~38 ~40 ~42 ~44 ~46 ~48 ~0 ~2 ~4 ~6 0 ~36 ~38 ~40 ~42 ~44 ~46 ~48 ~0 ~2 ~4 ~6 Sound pressure (db) Sound pressure (db) 4

Dimensions -A-N Four,.3±0. dia. PCB Mounting Holes (Unit: mm) 29.0 max. (28.8)* 2.7 max. (2.)* 7.±0..7 max. (.)* (2.3) ±0. ±0. Terminal Arrangement/ Internal Connections @0. 0.33 7. * Average value 3 4 (No coil polarity) -A-E-N -A-E-HR -A-E-TV8 Six,.3±0. dia. PCB Mounting Holes 29.0 max. (28.8)* 2.7 max. (2.)*.7 max. (.)* 7.±0. (2.3) ±0. ±0. Terminal Arrangement/ Internal Connections @0. 0.33 7. * Average value 3 4 8 6 (No coil polarity) --E --E-HR PCB Mounting Holes Eight,.3 ± 0. dia. ± 0. ± 0. 29.0 max. (28.8)* 2.7 max. (2.)*.7 max. (.)* 7. ± 0. (2.3) ± 0. Terminal Arrangement/ Internal Connections @0. 7. 2 3 4 0.33 * Average value 8 7 6 (No coil polarity)

Approved Standards U Recognized (File No.E4643) and CSA Certified (File No. R3928) Model Contact form Coil ratings Contact ratings Number of test operations 2 A, 20 VAC Resistive, 40 C -A-N SPST-NO (a) to 24 VDC 2 A, 24 VDC Resistive, 40 C 00,000 TV-, VAC, 40 C 2,000 6 A, 20 VAC Resistive, 40 C -A-E-N SPST-NO (a) to 24 VDC 6 A, 24 VDC Resistive, 40 C 0,000 TV-, VAC, 40 C 2,000 6 A, 277 VAC eneral, 40 C 0,000 TV-8, VAC, 40 C 2,000 -A-E-TV8 SPST-NO(a) to 48 VDC A300 Pilot Duty, 7 VA, 240 VAC, 40 C 30,000 /2 Hp, VAC, 40 C 6,000 60 RA/0 FA, 20 VAC, 40 C 6,000 6 A, 277 VAC eneral, 40 C 0,000 -(A)-E-HR SPST-NO (a) to 48 VDC TV-, VAC, 40 C 2,000 A300 Pilot Duty, 7 VA, 240 VAC, 40 C 30,000 --E SPDT-NO (a) 24 to 240 VAC /2 Hp, VAC, 40 C 6,000 (--E) 60 RA/0 FA, 20 VAC, 40 C 6,000 to 48 VDC A, 20 VAC eneral, 40 C 0,000 SPDT-NC (b) 24 to 240 VAC (--E) A, 24 VDC Resistive, 40 C 0,000 VDE Certified (EN680-) (icense No. 4000772) Model Contact form Coil ratings Contact ratings Number of test operations -A-N SPST-NO (a), 2, 24VDC 2 A, 20 VAC cosφ=, 8 C 60,000 -A-E-N SPST-NO (a), 2, 24VDC 6 A, 20 VAC cosφ=, 8 C 30,000 6 A, 20 VAC cosφ=, 8 C,000 -A-E-TV8 SPST-NO (a), 2, 24, 48 VDC 240 VAC 00 A (0-P) Steady 0 A (rms), 8 C 0,000 240 VAC 0 A (0-P) Steady A (rms), 8 C 00,000 SPST-NO (a) 6 A, 20 VAC cosφ=, 8 C,000 -(A)-E-HR, 2, 24, 48 VDC 240 VAC 00 A (0-P) Steady 0 A (rms), 8 C 0,000 SPDT-NO (a) 240 VAC 0 A (0-P) Steady A (rms), 8 C 00,000 --E SPDT-NO (a) 24, 00, /, 0, 230/240 VAC (0 Hz) 6 A, 20 VAC cosφ =, 70 C,000 Creepage distance Clearance distance Insulation material group coil-contact circuit Type of insulation open contact circuit Rated Insulation voltage Pollution degree Rated voltage system Over voltage category Category of protection according to IEC 680- Tracking Index of relay base 8 mm min. 8 mm min. IIIa Reinforced Micro disconnection 20 V 3 (Flux protection) 20 V III RT II (Flux protection) PTI 20 V min. (housing parts) 6

Precautions Please refer to PCB Relays Common Precautions for correct use. Correct Use Mounting When mounting a -N Relay (Silent Relay) on a PCB, use a diode for surge absorption for the coil. Wiring of Models (-E) models (-E) have a structure that connects two terminals from one contact. When designing the circuit, use both terminals. If you use only one terminal, the Relay may be unable to satisfy specified performance. Others Do not decrease coil voltage after operation and do not use a pulse wave drive. Precautions for Correct Use This product is not suitable for vehicles such as automobiles (including two-wheeled vehicles). If the product is used in the following applications, consult your OMRON sales representative to check the necessary items according to the specification sheets.also make sure the product is used within the specified ratings and performance ranges with an ample margin and implement safety measures, such as designing a safety circuit, to minimize danger should the product fail. a. Outdoor use, uses involving potential chemical contamination or electrical interference. b. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, safety equipment, and equipment that could present a risk to human life or body. c. Equipment requiring a high level of reliability, such as gas, water, or electrical supply systems. Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K32-E-08 066(0307)(O) 7