Electro-Magnetic Flowmeters COPA-XE

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

Magnetic Flowmeter Systems

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

E l e c t r o m a g n e t i c f l o w m e t e r s

Instruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital)

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev NB Catalog

ABB Instrumentation. Flowmeter. Specification DataFile

MagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

MagneW Two-wire PLUS+ Two-wire Electromagnetic Flowmeter

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev NA July 2004.

Ambient Conditions. Operating Conditions. Pressure

Rosemount 8712 D/H and 8732C Configuration Data Sheet

Advanced instrumentation solutions crafted with highest precision

Rosemount 8750W Magnetic Flowmeter System

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Product Data Sheet Contents

Rosemount 3101, 3102, and 3105

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

8000A Series Compact Magnetic Flowtubes Wafer Body, Ceramic- or pfa-lined 1.6 to 150 mm (1/16 to 6 in) Line Sizes

Madison Metropolitan Sewerage District Notice of Request for Proposals

Digital conductivity transmitter

PAD - Heavy Duty Differential Pressure Trasmitter

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

Specifications ELECTROMAGNETIC FLOWMETER. LF664/LF620 LF664/LF to 78 (500 to 1950mm) Overall Specifications TIC-LF664K

OPTIFLUX 5000 Technical Datasheet

ProcessMaster FEP300 Electromagnetic Flowmeter. The process industry's first choice

Smart Two-wire Electromagnetic Flowmeter

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

Princo MagneLevel Model LML

ProcessMaster FEP300 Electromagnetic flowmeter. The process industry's first choice

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

Model Sono-Trak Transit Time

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

OPTIFLUX 5000 Technical Datasheet

Compact Orifice Flow Meter

EN-2018 MAGNETIC FLOW METERS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

JUMO flowtrans MAG S01

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

ABB MEASUREMENT & ANALYTICS DATA SHEET. HygienicMaster FEH630 Electromagnetic flowmeter

FLOMID FX Electromagnetic Flowmeter

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

WATERFLUX 3070 Technical Datasheet

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

OPTIFLUX 1000 Technical Datasheet

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

Electromagnetic Flowmeter FXE4000 (COPA-XE/MAG-XE)

ProcessMaster FEP500 Electromagnetic Flowmeter. The process industry's first choice. Maximum measuring accuracy Maximum measuring error: 0.

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

Electromagnetic Flowmeter Hygienic/Sanitary

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

FSM4000 Electromagnetic Flowmeter. Measurement made easy. The all-purpose flowmeter for conductive fluids

Electromagnetic Flow Measuring System promag 35

Foxboro. FIELD DEVICES - FLOW Product Specifications PSS 1-6F8 A

Level Lance Model 5100

Level Measurement Continuous level measurement Radar transmitters

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

Smart Pressure Transmitter

LA-5000 SERIES LINEAR VALVE ACTUATORS

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

G SERIES PRECISION METERS

ProcessMaster / HygienicMaster

Metal tube variable area flowmeters for gases, liquids and steam

Coriolis Massflowmeter

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK

Level Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

FLOWMETER. Siemens MAG 5000/6000. Overview

Level Measurement Continuous level measurement Radar transmitters

Magnetic Inductive Flowmeter

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11

Indumax CLS50/CLS50D. Technical Information

TIDALFLUX 2300 F Technical Datasheet

BinMaster Price Book

The Metropolitan Sewer District of Greater Cincinnati

Process display RIA 261

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

Magnetostrictive Level Transmitter

Flow Detection MDS Integral or Remote Housing FUNCTION TYPICAL USES. Microwave Doppler Switch Solids - Chute and Conveyor GHz Sender Receiver

Transcription:

Abridged Specifications: E/A Sensor with 50SM1000 Transmitter The E/A flanged sensors and 50SM1000 transmitters are AC magnetic flowmeters. These systems are recommended noisy slurries, applications involving pulsating flow, and high speed of response applications. Sizes 1 to 12 in. (E); 14 in. to 24 in. (A) Transmitter Pressure Process Temperature Liner Electrodes Sensor Housing 50SM1000 up to 740 psi @ 100F (see full specifications for more information) ANSI Class 150 (all sizes) and Class 300 (1 to 12 in.) flanges Up to 356 F (max limit varies with liner selection) Hard or soft rubber (2 to 24 in.); Polyurethane (2 to 24 in.); Neoprene (2 to 24 in.); PTFE (1 to 24 in.); Tefzel (1 to 12 in.); Linatex (2 to 24 in.) Flush, bullet nose or slurry type in 316 stainless steel; Hastelloy C; Titanium; Tantalum; Platinum- Iridium; Zirconium Epoxy painted cast Aluminum Sensor NEMA 4X (IP 65) General Purpose. Classification Option for FM Approved for Class I, Division 2, Groups A to D (See full Specifications for more information) Transmitter Classification System Accuracy Conductivity Excitation NEMA 4X (IP 65) General Purpose 1.0% (1.5 to 33.3 feet per second) Greater than 20 µs/cm AC Features/ Accidental sensor submergence (IP 67) Options Analog output Scaled frequency output Alarms Contact outputs Remote totalizer reset Empty pipe detection Bi-directional flow measurement Full Diagnostics Loop test mode Illuminated 2-line LCD display Communications HART, RS-485, or RS-232 options Mounting Transmitter Power Field mounted 115/230 V ac Complete product specifications and options can be viewed or downloaded from www.abbinfozone.com

Design Level (For Use w/remote 50SM1000 Converter) Sizes 1" to 12"... E Sizes 14" to 24"...A Meter Lay Length t Short Form (W-Mag), Standard (1/2" - 12" only)...d Liner Hard Rubber... A Soft, Natural Rubber... B Polyurethane... D PTFE Teflon... E Neoprene... L Tefzel... N Linatex (Consult Warminster for Price adder sizes 14")... P Size Y 25mm (1")...09 Y 40mm (1-1/2")...11 50mm (2")...12 80mm (3)...14 100mm (4")...15 150mm (6")...17 200mm (8")...18 250mm (10")...19 300mm (12 )...20 Poly or Neo. 350mm (14")...21 400mm (16")...22 450mm (18")...35 500mm (20")...23 600mm (24")...24 t Consult full specification for other options Y Teflon or Tefzel Liner only. Æ Customer electrical connection box has PG 13.5 cable seal connections. v Customer electrical connection box has 1/2" NPT conduit seal connections. U 12-inch size only with Polyurethane or Neoprene liner; F-F is 18-inches (457 mm).

Flange Standard/Pressure Rating ANSI Class 150...P ANSI Class 300 Flange Material Carbon Steel, Standard... 1 304 Stainless Steel (150 Class only) Protector Plate None Required 316 Stl.Stl... B Hastelloy C... E Electrode Design Flush, Standard... 2 (Bullet Nose... 3 vslurry Service (14"-24" only)... 7 Electrode Material 316 Stainless Steel...B Hastelloy B...C Hastelloy C...D Titanium...E t Tantalum...F t Platinum/Iridium (14" Consult Factory)...H Zirconium...L Customer electrical connection box has 1/2 in. NPT conduit seal connections For Teflon lined meters only. Serves as grounding ring. t Teflon or Tefzel Liner only. ( 2" and larger sizes only. Electrode material must be Stainless Steel. v Liner must be Polyurethane, Linatex, or Neoprene and electrode material must be stainless steel.

Price Certification General Purpose... A FM Approved Cl I, Div. 2, Gps. A,B,C&D Standard... K Explosion Proof, FM Cl I, Div. 1, Gps B,C & D (1"-12" only)... L Enclosure Classification IEC 529 IP 65, NEMA 4X... 1 piec 529 IP 67, Accidental Submergence in water to 33 ft for 48 hrs... 2 U IEC 529 IP 68, Continuous Submergence in water to 33 ft... 5 UIEC 529 IP 67, Accidential Submergence to 33 ft. for 48 hrs and Potted Terminal Box (Level 9 Protection)... 9 Process Temperature Range (For Liner Selection) Teflon PTFE or Tefzel, up to 266 F (130 C)...1 Teflon PTFE up to 356 F (180 C) (1"-12" only)...2 Hard Rubber, Linatex up to 175 F (80 C)...3 Polyurethane/Neoprene up to 190 F (88 C)...4 Teflon PTFE 302ºF (150ºC)...5 Line/Excitation Frequency 50 Hz...1 60 Hz, Standard...3 Customer Information Language English w/riveted SST Tag... 2 zenglish w/self Adhesive Tag... 8 Remote Converter Type 50SM1000... 1 Not specified... X Permantly Installed Signal Cable tfor Enclosure Classification 5 & 9 Only Cable Length 50 Feet...05 Not Required...XX p Standard 50 feet of cable furnished for each meter. U Cable is permanently attached and the length must be specified at time of order under "Permanently Installed Signal Cable" character. Level 5 is not available with Teflon liner material. t Consult Factory for Lengths over 50 feet. z Not available with continuous submergence enclosure (Class 5).

50SM1000 Excitation Frequency 50 Hz... 1 60 Hz... 3 Certification...A Primary Type (1/2" - 12")... 1 tv (14" - 24")... 3 50SM1 Design Level... C Software Level... X Enclosure NEMA 4X Field housing w/pg 13.5 Conn...B NEMA 4X Field Housing w/1/2" NPT Conn. Standard D Contact Outputs Octocoupler...1 Relay Contact...2 Pulse Outputs / Data Link Without Without...0 Active Fwd & Rev. Without...1 Without RS485...4 Without RS232...5 Contact Function Error Alarm...AA Forward/Reverse Flow Signal...AB Forward/Reverse Flow Signal & 2 Process Alarms...AC 2 Process Alarms...BA v Power supply must be 115 VAC t Enclosure must be D Only available with primary type 1 Includes error alarm. Forward/reverse signal is always via relay.

50SM1000 50SM1 _ Additional Options None...A External Totalizer Reset...B Zero Return...C External Totalizer Reset & Zero Return...D Empty Pipe Detector...E Empty Pipe Detector & External Totalizer Reset...F HART Protocol...G HART Protocol & Empty Pipe Detection...H HART Protocol & Empty Pipe Det. & Tot. Reset...J HART Protocol & Totalizer Reset...T Power Supply Æ115 Vac...C 230 Vac...A Customer Information Language English... 2 Signal Cable Not Required... 0 Required for E (1/2" - 12")... 1 Required for A (14" - 24")... 2 External Totalizer Reset Switch Not Required... 0 vrequired... 1 Current Output 4 to 20 ma, Standard...1 0 to 20 ma...2 Pulse output/data link must be 0 or 1. Æ Does not include power requirement for primary if Flowmeter Primary Type is 3. 50 feet of cable is furnished as standard. Maximum cable length is 100 feet. v Additional options must be B, D, F, J, or T.