Abridged Specifications: E/A Sensor with 50SM1000 Transmitter The E/A flanged sensors and 50SM1000 transmitters are AC magnetic flowmeters. These systems are recommended noisy slurries, applications involving pulsating flow, and high speed of response applications. Sizes 1 to 12 in. (E); 14 in. to 24 in. (A) Transmitter Pressure Process Temperature Liner Electrodes Sensor Housing 50SM1000 up to 740 psi @ 100F (see full specifications for more information) ANSI Class 150 (all sizes) and Class 300 (1 to 12 in.) flanges Up to 356 F (max limit varies with liner selection) Hard or soft rubber (2 to 24 in.); Polyurethane (2 to 24 in.); Neoprene (2 to 24 in.); PTFE (1 to 24 in.); Tefzel (1 to 12 in.); Linatex (2 to 24 in.) Flush, bullet nose or slurry type in 316 stainless steel; Hastelloy C; Titanium; Tantalum; Platinum- Iridium; Zirconium Epoxy painted cast Aluminum Sensor NEMA 4X (IP 65) General Purpose. Classification Option for FM Approved for Class I, Division 2, Groups A to D (See full Specifications for more information) Transmitter Classification System Accuracy Conductivity Excitation NEMA 4X (IP 65) General Purpose 1.0% (1.5 to 33.3 feet per second) Greater than 20 µs/cm AC Features/ Accidental sensor submergence (IP 67) Options Analog output Scaled frequency output Alarms Contact outputs Remote totalizer reset Empty pipe detection Bi-directional flow measurement Full Diagnostics Loop test mode Illuminated 2-line LCD display Communications HART, RS-485, or RS-232 options Mounting Transmitter Power Field mounted 115/230 V ac Complete product specifications and options can be viewed or downloaded from www.abbinfozone.com
Design Level (For Use w/remote 50SM1000 Converter) Sizes 1" to 12"... E Sizes 14" to 24"...A Meter Lay Length t Short Form (W-Mag), Standard (1/2" - 12" only)...d Liner Hard Rubber... A Soft, Natural Rubber... B Polyurethane... D PTFE Teflon... E Neoprene... L Tefzel... N Linatex (Consult Warminster for Price adder sizes 14")... P Size Y 25mm (1")...09 Y 40mm (1-1/2")...11 50mm (2")...12 80mm (3)...14 100mm (4")...15 150mm (6")...17 200mm (8")...18 250mm (10")...19 300mm (12 )...20 Poly or Neo. 350mm (14")...21 400mm (16")...22 450mm (18")...35 500mm (20")...23 600mm (24")...24 t Consult full specification for other options Y Teflon or Tefzel Liner only. Æ Customer electrical connection box has PG 13.5 cable seal connections. v Customer electrical connection box has 1/2" NPT conduit seal connections. U 12-inch size only with Polyurethane or Neoprene liner; F-F is 18-inches (457 mm).
Flange Standard/Pressure Rating ANSI Class 150...P ANSI Class 300 Flange Material Carbon Steel, Standard... 1 304 Stainless Steel (150 Class only) Protector Plate None Required 316 Stl.Stl... B Hastelloy C... E Electrode Design Flush, Standard... 2 (Bullet Nose... 3 vslurry Service (14"-24" only)... 7 Electrode Material 316 Stainless Steel...B Hastelloy B...C Hastelloy C...D Titanium...E t Tantalum...F t Platinum/Iridium (14" Consult Factory)...H Zirconium...L Customer electrical connection box has 1/2 in. NPT conduit seal connections For Teflon lined meters only. Serves as grounding ring. t Teflon or Tefzel Liner only. ( 2" and larger sizes only. Electrode material must be Stainless Steel. v Liner must be Polyurethane, Linatex, or Neoprene and electrode material must be stainless steel.
Price Certification General Purpose... A FM Approved Cl I, Div. 2, Gps. A,B,C&D Standard... K Explosion Proof, FM Cl I, Div. 1, Gps B,C & D (1"-12" only)... L Enclosure Classification IEC 529 IP 65, NEMA 4X... 1 piec 529 IP 67, Accidental Submergence in water to 33 ft for 48 hrs... 2 U IEC 529 IP 68, Continuous Submergence in water to 33 ft... 5 UIEC 529 IP 67, Accidential Submergence to 33 ft. for 48 hrs and Potted Terminal Box (Level 9 Protection)... 9 Process Temperature Range (For Liner Selection) Teflon PTFE or Tefzel, up to 266 F (130 C)...1 Teflon PTFE up to 356 F (180 C) (1"-12" only)...2 Hard Rubber, Linatex up to 175 F (80 C)...3 Polyurethane/Neoprene up to 190 F (88 C)...4 Teflon PTFE 302ºF (150ºC)...5 Line/Excitation Frequency 50 Hz...1 60 Hz, Standard...3 Customer Information Language English w/riveted SST Tag... 2 zenglish w/self Adhesive Tag... 8 Remote Converter Type 50SM1000... 1 Not specified... X Permantly Installed Signal Cable tfor Enclosure Classification 5 & 9 Only Cable Length 50 Feet...05 Not Required...XX p Standard 50 feet of cable furnished for each meter. U Cable is permanently attached and the length must be specified at time of order under "Permanently Installed Signal Cable" character. Level 5 is not available with Teflon liner material. t Consult Factory for Lengths over 50 feet. z Not available with continuous submergence enclosure (Class 5).
50SM1000 Excitation Frequency 50 Hz... 1 60 Hz... 3 Certification...A Primary Type (1/2" - 12")... 1 tv (14" - 24")... 3 50SM1 Design Level... C Software Level... X Enclosure NEMA 4X Field housing w/pg 13.5 Conn...B NEMA 4X Field Housing w/1/2" NPT Conn. Standard D Contact Outputs Octocoupler...1 Relay Contact...2 Pulse Outputs / Data Link Without Without...0 Active Fwd & Rev. Without...1 Without RS485...4 Without RS232...5 Contact Function Error Alarm...AA Forward/Reverse Flow Signal...AB Forward/Reverse Flow Signal & 2 Process Alarms...AC 2 Process Alarms...BA v Power supply must be 115 VAC t Enclosure must be D Only available with primary type 1 Includes error alarm. Forward/reverse signal is always via relay.
50SM1000 50SM1 _ Additional Options None...A External Totalizer Reset...B Zero Return...C External Totalizer Reset & Zero Return...D Empty Pipe Detector...E Empty Pipe Detector & External Totalizer Reset...F HART Protocol...G HART Protocol & Empty Pipe Detection...H HART Protocol & Empty Pipe Det. & Tot. Reset...J HART Protocol & Totalizer Reset...T Power Supply Æ115 Vac...C 230 Vac...A Customer Information Language English... 2 Signal Cable Not Required... 0 Required for E (1/2" - 12")... 1 Required for A (14" - 24")... 2 External Totalizer Reset Switch Not Required... 0 vrequired... 1 Current Output 4 to 20 ma, Standard...1 0 to 20 ma...2 Pulse output/data link must be 0 or 1. Æ Does not include power requirement for primary if Flowmeter Primary Type is 3. 50 feet of cable is furnished as standard. Maximum cable length is 100 feet. v Additional options must be B, D, F, J, or T.