Electrical devices may only be mounted and connected by electrically skilled persons.

Similar documents
Electrical devices may only be mounted and connected by electrically skilled persons.

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

1 Safety instructions. 2 Device components. 3 Function. Radio Management Repeater. Operationsmanual

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Radio bus system. Radio socket-outlet adapter for switching Order No. :

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

Electrical devices may only be mounted and connected by electrically skilled persons.

User Manual 3X300 DIMMER MODULE DM03B02KNX

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2)

Radio motion detector comfort 1.1 m/2.2 m quicklink Order number

Universal Radio Cord Dimmer Order No.: Function

KNX manual 1-channel flush-mounted switch actuator SU 1

instabus EIB product documentation

Operating instruction

Electrical devices may only be mounted and connected by electrically skilled persons.

B-Tronic EasyControl EC5401B

Rev Product Manual ABB i-bus KNX. Heating actuator 1gang with 6164/11 U-500. Power and productivity for a better world TM

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. :

Technical data: Instabus EIB supply Voltage: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

Operating instructions Flat-Type Wall-Mounted Radio Control

KNX ENO 634 (32-channel AP)

Data sheet. Function description. Benefits

Product documentation

Electrical devices may only be mounted and connected by electrically skilled persons.

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

STC-KNX (32-channel AP)

Operating Instructions. EnOcean radio wall transmitter

Instabus Radio Control Converter Installation Instructions

Installer manual inputs/outputs interface for led KNX

Product Manual. ABB i-bus EIB / KNX. Universal Interface US/U Intelligent Installation Systems

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

1. Use of the application program

EIB/KNX Switch Actuators. User manual

Radio System Strobe Wizard Plus Freemask

Radio-control universal dimmer (built-in type) Installation Instructions

Radio Management. Radio Management Controller. Manual. Art.-no.: FMC 1000 GB J:

Product documentation

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx

Wireless valve actuator for bidirectional EnOcean communication. The SAB05 combines with message server and enocean transmitter.

Unidirectional Gateway EnOcean - KNX/BUS

KNX S-UP. Actuator for 230 V or 24 V. Installation and Adjustment

Binary Inputs. Ref.-No. KNX universal binary input, 8-gang. ETS-product family: Series embodiment (SE-) device (2 units) Ref.-No.

Instruction manual. art Installation manual

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

Use of the application program. Functional description. GAMMA instabus Application program description. October 2007

Copyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031

K-BUS Switch Actuator

INSTABUS RADIO GATEWAY

Bosch Smart Home. Door/Window Contact Instruction Manual

OPERATING INSTRUCTIONS Digital weekly time switch

application software

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

Sentido KNX Manual. Sentido KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium

Copyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031

Use of the application program. Functional description. GAMMA instabus Application program description. May A8 Venetian blind actuator

Radio remote control.

LITECOM. Special luminaires SEQUENCE infinity

KNX Room temperature controller

TX4400 UHF CB RADIO INSTRUCTION MANUAL TX4400 INSTRUCTION MANUAL PAGE 1

STX Stair lighting controller.

ON!Track smart tag AI T380. English. Printed: Doc-Nr: PUB / / 000 / 02

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

KNX ENO 620/622 (32-channel AP)

Fixture Built-in Sensor Daylight Harvest Version

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Owner s Manual BL

COD GB / 1.0 RBAND/UMS - RBAND/CSM

Smart-house Dimmer Power dimmer up to 500W Type SH2D500W230

application software

Level Switch NRS 2-50 NRS Original Installation Instructions English

Please enter the identity code of your device here!

FL ballasts Electronic dimming. PCA T5 EXCITE lp Y, 3 and 4x14/24 W EXCITE T5

EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

KNX presence detectors for ceiling flush mount EK-DD2-TP, EK-DE2-TP

animeo KNX/EIB 4 AC Motor Controller WM/DRM V AC

animeo KNX 4 DC 2 A Motor Controller WM 24 V DC Installation manual

Radio receiver. Instructions for Use. for the reception of a flush actuation via radio signal. en_int

Please enter the identity code of your device here!

animeo KNX/EIB 4 DC/E Motor Controller WM V AC Installation manual

WIRELESS DIMMER FOR HEATING

Tebis application software

Manual. Radio Control Central Unit

AT-SL-DDR & AT-SL-DDR-SA

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

Technical Manual MDT LED-Indicator

Application Description

Smart Dupline Wireless dimmer with energy reading Type SHJWD200WExxx


MultiMeter-Pocket CAT III 1000 V

Electrical devices may only be mounted and connected by electrically skilled persons.

User Manual of MOBILUS C-SWP external module.

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB

Transcription:

Art. No. : FM..1561.07.. Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully. Danger of electric shock. Always disconnect before carrying out work on the devise or load. In so doing, take all the circuit breakers into account, which support dangerous voltages to the device and or load. Danger of electric shock. The device is not suitable for disconnection from supply voltage. Depending on the insert used, the load is not electrically isolated from the mains, even when the device is switched off. These instructions are an integral part of the product, and must remain with the end customer. 2 Device components Figure 1: Device components (1) FM insert (2) Frame (3) Radio button (4) Status LED 3 Function Intended use - Manual and radio-controlled operation of suitable flush-mounted inserts for switching or dimming (see accessories) - Mounting on flush-mounted insert - Operation with suitable radio transmitters i No operation on pulse insert, 2-wire and 3-wire extension inserts possible. 1/15

Product characteristics - Evaluation of extensions - Scene operation possible - Status indication with LED - Status feedback to radio transmitter - Switch-on brightness can be saved permanently when combined with flush-mounted inserts for dimming Can be set with enet server: - Maximum brightness - Minimum brightness - Dimming speed - Switch-on delay / switch-off delay - Dim up/dim down ramp - Switch-off warning - Operation locks - Continuous on, Continuous off - Hotel function - Run-on time - Light control Supplementary functions with enet Server: - Fully encrypted radio transmission (AES-CCM) from enet Server software version 2.0 - Update of the device software - Reading of error memory Response after mains voltage return The response after mains voltage return can be configured with the enet Server. Default setting: Off. 4 Operation i When operating with the enet Server, operation and signalling could vary from what is described here. Operation is performed directly on the device or on a connected extension. i If operation takes place with radio transmitters, please observe the radio transmitter instructions. Switch light o Press button for less than 0.4 seconds. The light is switched on or off. In combination with inserts for dimming, switch-on takes place at the saved switch-on brightness. Status-LED (4) lights up: output is switched on. Status-LED (4) off: output is switched off. i In the case of the HVAC insert, only the output Kanal 1 is switched, whilst the output HLK switches according to the output Kanal 1 (see operation manual of the insert). Adjust the brightness Button is combined with an insert for dimming. Light is switched on. o Press top button for longer than 0.4 seconds. The light gets brighter up to maximum brightness. o Press bottom button for longer than 0.4 seconds. Light gets darker to minimum brightness. i Push-button: the light becomes brighter up to maximum brightness, remains there briefly and becomes dimmer down to minimum brightness, remains there briefly and becomes brighter again. This process repeats for as long as the push-button remains pressed. Switch light on with minimum brightness Button is combined with an insert for dimming. 2/15

o i Press button at bottom for longer than 0.4 seconds. Light is switched on at minimum brightness. If the button or 2-wire extension is pressed at the top or the push-button is pressed for longer than 0.4 seconds, then the light is switched on to minimum brightness and then brighter. Save switch-on brightness Button is combined with an insert for dimming. o Set light to the required brightness. o Press button over entire surface for longer than 4 seconds. Switch-on brightness is saved. For confirmation the lighting switches off briefly and then on again to the saved switch-on brightness. i An push-button cannot be used to save the switch-on brightness. 5 Information for electrically skilled persons 5.1 Fitting and electrical connection DANGER! Electrical shock when live parts are touched. Electrical shocks can be fatal. Before carrying out work on the device or load, disengage all the corresponding circuit breakers. Cover up live parts in the working environment. Connecting and fitting the device To ensure good transmission quality, keep a sufficient distance from any possible sources of interference, e.g. metallic surfaces, microwave ovens, hi-fi and TV systems, ballasts or transformers. The flush-mounted insert is correctly fitted and connected (see instructions for flush-mounted insert). o Fit radio button (3) and frame (2) on flush-mounted insert (1). o Switch on mains voltage. o Carry out commissioning (see Commissioning chapter). 5.2 Commissioning i DANGER! Electrical shock when live parts are touched. Electrical shocks can be fatal. During commissioning, cover the parts carrying voltage on radio transmitters and actuators and in their surrounding area. The button can also be commissioned with enet server as an alternative to the commissioning described here. Connecting with radio transmitter Load is switched off. o Press button over entire surface for longer than 4 seconds. i Switch inserts switch the load on until the Status LED flashes. The status LED (4) flashes after 4 seconds. The button is in programming mode for approx. 1 minute. o Switch radio transmitter to programming mode as well (see radio transmitter instructions). o Trigger telegram on the radio transmitter (see instructions of the radio transmitter). The status LED lights up for 5 seconds. 3/15

i i The button is connected to the radio transmitter. The button and radio transmitter exit the programming mode automatically. If the status LED of the button flashes 3 times at 1-second intervals for approx. 5 seconds, then the programming operation was not successful. All the memory locations in the button or radio transmitter are occupied. All On and All Off buttons of a radio transmitter are connected to the actuator automatically as soon as the first connection to a radio transmitter takes place. Scene buttons must be connected separately. Disconnecting connection to a radio transmitter o Carry out the same steps as when connecting (see Connecting to radio transmitter). The status LED (4) flashes quickly for 5 seconds. The button is disconnected from the radio transmitter. The button and radio transmitter exit the programming mode automatically. i If there several connections or scene buttons for a radio transmitter, all connections must be disconnected individually. i All On and All Off buttons of a radio transmitter are disconnected automatically as soon as the last connection to the radio transmitter is disconnected. Manual disconnection is not possible. Resetting button to the default setting All connections to radio transmitters are disconnected and parameters are reset to default setting. i The connections in the radio transmitters are preserved and must be deleted separately. Load is switched off. o Press button over the entire surface for at least 20 seconds. i Switch inserts switch the load on until the Status LED flashes. The status LED flashes after 4 seconds. After 20 seconds the status LED flashes faster. o Release the button and press it briefly and fully once again within 10 seconds. The status LED flashes more slowly for approx. 5 seconds. The button is reset to default setting. 6 Appendix 6.1 Technical data Ambient temperature -5... +45 C Radio frequency 868.0... 868.6 MHz Transmitting range in free field typ. 100 m Transmission capacity max. 20 mw Receiver category 2 6.2 Parameter list The device parameters can be changed with the enet server: Device and channels Parameters Setting options, Basic setting Explanations 4/15

Function Operating mode Advanced device settings Parameters Manual commissioning Allow extension unit operation Channel settings "dimming" Parameters Light (dimming), light (switching), switching, unused Basic setting: Light (dimming) Normal operation Continuous on Continuous off Basic setting: Normal Operation Setting options, Basic setting Setting options, Basic setting Light (dimming) The channel is integrated for the "Lighting" central function in the enet SMART HOME app. Use the setting in combination with a dimming insert. Light (switching) The channel is integrated for the "Lighting" central function in the enet SMART HOME app. Use the setting in combination with a switching insert. Switching The channel is not integrated in any central function. Use the setting in combination with a switching insert. Unused The channel is not displayed in the enet SMART HOME app and is disabled for use in the commissioning interface. Normal operation The output can be operated with radio transmitters and the Prog button. Continuous on The output switches to continuously "On". All operations of radio transmitters and the Prog button are ignored. Continuous off The output switches to continuously "Off". All operations of radio transmitters and the Prog button are ignored. Explanations Blocks manual commissioning for the device channel. Note: In the "Off" setting, the device cannot be reset to the factory setting. Prevents operation via wired extensions. Explanations 5/15

Switch-on brightness 1...100 % Basic setting: 100 % Minimum brightness 1...67 % Basic setting: 5 % Maximum brightness 75...100 % Basic setting: 100 % Dimming adjustment time Switch-on delay Switch-off delay 1 60 s Basic setting: 4 s During brief operation, the output switches on at the set switch-on brightness. Note: If the value is above the set maximum brightness or below the minimum brightness, then the system will switch to the appropriate limit value. Specifies the minimum settable brightness. Note: If parameters or scene values are set to a level lower than the minimum brightness, then the system will dim to minimum brightness. Specifies the maximum settable brightness. Note: If parameters or scene values are set to a level higher than the maximum brightness, then the system will dim to maximum brightness. Time from minimum brightness until reaching maximum brightness (dimming speed). The load switches on after a delay. Repeated switch-on commands restart the delay time. If the load has not yet been switched on due to the delay when a switch-off command comes, then the load will remain off. The load switches off after a delay. Repeated switch-off commands restart the delay time. If the load has not yet been switched off due to the delay when a switch-on command comes, then the load will remain on. 6/15

Dim up ramp Dim down ramp Run-on time Manual switch-off of the runon time Operating hours 0...65535 Basic setting: Current value Time between switch-on and reaching switch-on brightness. The light is switched on at minimum brightness and then dimmed to the switch-on brightness. Only applies to switch-on with transmitters (short operation). If scenes are recalled or switching uses logic modules, the switch-on brightness is approached using so-called soft dimming (not configurable). Time until reaching minimum brightness. The light is dimmed to minimum brightness and then switched off. Only applies to switch-off with transmitters (short operation). If scenes are recalled or switching uses logic modules, the system switches off directly. As soon as a run-on time has been entered, the actuator will no longer remain on permanently, but only for the length of the run-on time. The run-on time is restarted if actuation is repeated. This parameter is directly connected to the "Manual switch-off of run-on time" parameter. Allows manual switch-off of a running run-on time. If the parameter is switched off, then a switch-off command will also switch the actuator on. Only visible if a run-on time was set. The time is counted during which the load is physically switched on. This parameter can be reset to "0", for example after exchanging the load. The Reset button is used to reset the meter to "0". The device must be programmed to apply the change. 7/15

Extended channel settings "dimming" Parameters Operating mode Manual commissioning Local Operation Setting options, Basic setting Normal operation Continuous on Continuous off Basic setting: Normal Operation Behaviour on voltage return On Off Last value Configured brightness Brightness on voltage return 0...100 % Basic setting: 100 % Behaviour after the end of the disabling function Manual saving of the scene values On Off no change Last value Basic setting: No change Explanations see Device and channels Blocks manual commissioning for the device channel. Note: In the "Off" setting, the device cannot be reset to the factory setting. Blocks the output for operation using the Prog button. output after voltage return. Brightness value, set by the output after voltage return (mains voltage). The parameter "Behaviour after voltage return" must be set to "Configured brightness". Note: If the value is above the set maximum brightness or below the minimum brightness, then the system will switch to the appropriate limit value. Behaviour of the output when a block is removed. Disables the saving of the current brightness value as scene value in an actuator for a command via a transmitter. 8/15

Switch-off warning Priority, lock-out protection 0...4 Basic setting: 1 Activate lock-out protection brightness value Deactivate lock-out protection brightness value Basic setting: 0 % Basic setting: 0 % Priority, restraint 0...4 Basic setting: 2 Activate forced operation brightness value Deactivate forced operation brightness value Basic setting: 100 % Basic setting: 0 % Priority, wind alarm 0...4 Basic setting: 3 Activate wind alarm brightness value Basic setting: 0 % If the switch-off warning is active, then, during switch-off, the systems dims to minimum brightness within 30 seconds and only then switches off. If the parameter "Dim down ramp" is configured as longer than 30 s, then the length of the dim down ramp is applied. If, during the dim down operation, another command is given, e.g. switch on or scene recall, then the switchoff warning stops and the command is executed. A switch-off command restarts the time for the switch-off warning. scene of type Lock-out protection for the channel. Note: 1 is the highest priority and 4 the lowest. 0 means no priority. output on activating the lockout protection. lock-out protection. Only visible when the priority for the lock-out protection is 0. scene of type Restraint for the channel. output on activating the forced operation. forced operation. Only visible when the priority for the forced operation is 0. scene of type Wind alarm for the channel. output on activating the wind alarm. 9/15

Deactivate wind alarm brightness value Basic setting: 0 % Priority, sun protection 0...4 Basic setting: 0 Activate sun protection brightness value Deactivate sun protection brightness value Basic setting: 100 % Basic setting: 0 % Priority, twilight 0...4 Basic setting: 0 Activate twilight brightness value Deactivate twilight brightness value Switch off brightness overshoot Switch on brightness undershoot Basic setting: 100 % Basic setting: 0 % wind alarm. Only visible when the priority for the wind alarm is 0. scene of type Sun protection for the channel. output on activating the sun protection. sun protection. Only visible when the priority for the sun protection is 0. scene of type Twilight for the channel. output on activating the twilight function. twilight function. Only visible when the priority for the twilight function is 0. Allows automatic switch-off according to the brightness. If the parameter is On, then the light controller switches off automatically when the brightness setpoint is greatly exceeded. Note: This parameter is not yet active, as a light controller has not yet been implemented. Allows automatic switch-on according to the brightness. If the parameter is On, then the light controller switches on automatically when the brightness setpoint is greatly undershot. We recommend only using the parameter in connection with the parameter "Switch-off on brightness overshoot". Note: This parameter is not yet active, as a light controller has not yet been implemented. 10/15

Hotel function Channel settings "switching" Parameters Switch-on delay Switch-off delay Run-on time Setting options, Basic setting If the hotel function is activated, the system will dim to 20 % brightness when a switch-off command is made. Switch-off is only possible with a forced position command. Note: If the minimum brightness is set to greater than 20 %, then the system dims to the set minimum brightness when the hotel function is activated. Explanations The load switches on after a delay. Repeated switch-on commands restart the delay time. If the load has not yet been switched on due to the delay when a switch-off command comes, then the load will remain off. The load switches off after a delay. Repeated switch-off commands restart the delay time. If the load has not yet been switched off due to the delay when a switch-on command comes, then the load will remain on. As soon as a run-on time has been entered, the actuator will no longer remain on permanently, but only for the length of the run-on time. The run-on time is restarted if actuation is repeated. This parameter is directly connected to the "Manual switch-off of run-on time" parameter. 11/15

Manual switch-off of the runon time Operating hours 0...65535 Basic setting: Current value Allows manual switch-off of a running run-on time. If the parameter is switched off, then a switch-off command will also switch the actuator on. Only visible if a run-on time was set. The time is counted during which the load is physically switched on. This parameter can be reset to "0", for example after exchanging the load. The Reset button is used to reset the meter to "0". The device must be programmed to apply the change. Extended channel settings "switching" Parameters Operating mode Manual commissioning Local Operation Setting options, Basic setting Normal operation Continuous on Continuous off Basic setting: Normal Operation Behaviour on voltage return On Off Last value Explanations see Device and channels Blocks manual commissioning for the device channel. Note: In the "Off" setting, the device cannot be reset to the factory setting. Blocks the output for operation using the Prog button. output after voltage return. Behaviour after the end of the disabling function Manual saving of the scene values On Off no change Last value Basic setting: No change Behaviour of the output when a block is removed. Disables the saving of the current brightness value as scene value in an actuator for a command via a transmitter. 12/15

Switch-off warning Priority, lock-out protection 0...4 Basic setting: 1 Activate lock-out protection switching state Deactivate lock-out protection switching state Priority, restraint 0...4 Basic setting: 2 Activate forced operation switching state Deactivate forced operation switching state Priority, wind alarm 0...4 Basic setting: 3 Activate wind alarm switching state If the switch-off warning is active, then, during switch-off, the systems dims to minimum brightness within 30 seconds and only then switches off. If the parameter "Dim down ramp" is configured as longer than 30 s, then the length of the dim down ramp is applied. If, during the dim down operation, another command is given, e.g. switch on or scene recall, then the switchoff warning stops and the command is executed. A switch-off command restarts the time for the switch-off warning. scene of type Lock-out protection for the channel. Note: 1 is the highest priority and 4 the lowest. 0 means no priority. output on activating the lockout protection. lock-out protection. Only visible when the priority for the lock-out protection is 0. scene of type Restraint for the channel. output on activating the forced operation. forced operation. Only visible when the priority for the forced operation is 0. scene of type Wind alarm for the channel. output on activating the wind alarm. 13/15

Deactivate wind alarm switching state Priority, sun protection 0...4 Basic setting: 0 Activate sun protection switching state Deactivate sun protection switching state Priority, twilight 0...4 Basic setting: 0 Activate twilight brightness value Deactivate twilight switching state wind alarm. Only visible when the priority for the wind alarm is 0. scene of type Sun protection for the channel. output on activating the sun protection. sun protection. Only visible when the priority for the sun protection is 0. scene of type Twilight for the channel. output on activating the twilight function. twilight function. Only visible when the priority for the twilight function is 0. Information window In the Information window, the load can be controlled and the information about the device can be displays. Channel control/channel information Display value Current dimming value Load state Restraint Operating hours Explanations The load can be dimmed using the slider or a brightness value entry. Only when "Function" is set to "Light (Dimming)". The load can be switched on or off. Display of forced position status. Display of the operating hours since the last restart in the Settings window Einstellungen. 6.3 Accessories Operation with all Light Management flush-mounted inserts for switching or dimming. 6.4 Conformity Albrecht Jung GmbH & Co. KG hereby declares that the radio system type Art. No. FM..1561.07.. corresponds to the directive 2014/53/EU. You can find the full article number on the device. The complete text of the EU Declaration of Conformity is available under the Internet address: www.jung.de/ce 14/15

6.5 Warranty The warranty follows about the specialty store in between the legal framework as provided for by law. ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle GERMANY Telefon: +49 2355 806-0 Telefax: +49 2355 806-204 kundencenter@jung.de www.jung.de 15/15