Electrical devices may only be mounted and connected by electrically skilled persons.

Similar documents
Electrical devices may only be mounted and connected by electrically skilled persons.

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Radio bus system. Radio socket-outlet adapter for switching Order No. :

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

Electrical devices may only be mounted and connected by electrically skilled persons.

Electrical devices may only be mounted and connected by electrically skilled persons.

Universal Radio Cord Dimmer Order No.: Function

Electrical devices may only be mounted and connected by electrically skilled persons.

1 Safety instructions. 2 Device components. 3 Function. Radio Management Repeater. Operationsmanual

Instabus Radio Control Converter Installation Instructions

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2)

User Manual 3X300 DIMMER MODULE DM03B02KNX

Radio motion detector comfort 1.1 m/2.2 m quicklink Order number

Radio-control universal dimmer (built-in type) Installation Instructions

KNX manual 1-channel flush-mounted switch actuator SU 1

Operating instructions. Radio weather station

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

Technical data: Instabus EIB supply Voltage: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

instabus EIB product documentation

B-Tronic EasyControl EC5401B

Rev Product Manual ABB i-bus KNX. Heating actuator 1gang with 6164/11 U-500. Power and productivity for a better world TM

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. :

Operating instruction

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

Automatic-switch (1,10m): Standard attachment Order No.: Automatic-switch (2,20m): Standard attachment Order No.:

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

KNX ENO 634 (32-channel AP)

Data sheet. Function description. Benefits

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

STC-KNX (32-channel AP)

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

Operating Instructions. Instabus Audio Actuator, 4-gang

EIB/KNX Switch Actuators. User manual

Radio System Strobe Wizard Plus Freemask

Installer manual inputs/outputs interface for led KNX

Operating Instructions. EnOcean radio wall transmitter

Product Manual. ABB i-bus EIB / KNX. Universal Interface US/U Intelligent Installation Systems

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation

Wireless valve actuator for bidirectional EnOcean communication. The SAB05 combines with message server and enocean transmitter.

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx

Operating instructions Flat-Type Wall-Mounted Radio Control

1. Use of the application program

Binary Inputs. Ref.-No. KNX universal binary input, 8-gang. ETS-product family: Series embodiment (SE-) device (2 units) Ref.-No.

Use of the application program. Functional description. GAMMA instabus Application program description. October 2007

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Radio Management. Radio Management Controller. Manual. Art.-no.: FMC 1000 GB J:

KNX S-UP. Actuator for 230 V or 24 V. Installation and Adjustment

Instruction manual. art Installation manual

Copyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031

Copyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031

FL ballasts Electronic dimming. PCA T5 EXCITE lp Y, 3 and 4x14/24 W EXCITE T5

Use of the application program. Functional description. GAMMA instabus Application program description. May A8 Venetian blind actuator

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

LITECOM. Special luminaires SEQUENCE infinity

Operating instructions II / 2004

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

INSTABUS RADIO GATEWAY

MultiMeter-Pocket CAT III 1000 V

CU-DIN DIM 6-CH 0 10V KNX

Unidirectional Gateway EnOcean - KNX/BUS

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

User Manual March 2008

K-BUS Switch Actuator

Radio remote control.

FL ballasts Electronic dimming. PCA T8 ECO lp Y, 3x18 W and 4x18 W ECO T8

Manual. Radio Control Central Unit

STX Stair lighting controller.

FL ballasts Electronic dimming. PCA T5 ECO lp Y, 3x14/24 W and 4x14/24 W ECO T5

WIRELESS DIMMER FOR HEATING

Sentido KNX Manual. Sentido KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Fixture Built-in Sensor Daylight Harvest Version

Owner s Manual BL

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

OPERATING INSTRUCTIONS Digital weekly time switch

Technical Manual MDT LED-Indicator

Smart Dupline Wireless dimmer with energy reading Type SHJWD200WExxx

application software

Smart-house Dimmer Power dimmer up to 500W Type SH2D500W230


GUIDE TO TROUBLESHOOTING INFRA RED SYSTEMS

User Manual of MOBILUS C-SWP external module.

Original operating instructions Fail-safe inductive sensor GG507S

KNX Room temperature controller

System overview. be connected: Components that can. 1. OKIMAT IPS OM Massage motor. 7. Optional: Junction cable

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

FL ballasts Electronic dimming. PCA T8 EXCEL one4all lp Y II, W EXCEL T8

Awning control system GFM001. Installation and Operating Instructions

KNX ENO 620/622 (32-channel AP)

KNX presence detectors for ceiling flush mount EK-DD2-TP, EK-DE2-TP

AT-SL-DDR & AT-SL-DDR-SA


Product and Applications Description

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series

Please enter the identity code of your device here!

Transcription:

Order No. : 5490.. Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully. Danger of electric shock. Always disconnect before carrying out work on the devise or load. In so doing, take all the circuit breakers into account, which support dangerous voltages to the device and or load. Danger of electric shock. The device is not suitable for disconnection from supply voltage. Depending on the insert used, the load is not electrically isolated from the mains, even when the device is switched off. These instructions are an integral part of the product, and must remain with the end customer. 2 Device components Figure 1: Device components (1) FM insert (2) Frame (3) Radio button (4) Status LED 3 Function Intended use - Manual and radio-controlled operation of suitable flush-mounted inserts for switching or dimming (see accessories) - Mounting on flush-mounted insert - Operation with suitable radio transmitters i No operation on pulse insert, 2-wire and 3-wire extension inserts possible. 32582712 10499459 15.07.2016 1/10

Product characteristics - Evaluation of extensions - Scene operation possible - Status indication with LED - Status feedback to radio transmitter - Switch-on brightness can be saved permanently when combined with flush-mounted inserts for dimming Can be set with server: - Maximum brightness - Minimum brightness - Dimming speed - Switch-on delay / switch-off delay - Dim up/dim down ramp - Switch-off warning - Operation locks - Continuous on, Continuous off - Hotel function - Run-on time - Light control i If settings are changed with the server, operation and signalling could vary from what is described here. i The parameter list is in the Internet in the documentation for this device. Supplementary functions with server: - Update of the device software - Reading of error memory Response after mains voltage return The response after mains voltage return can be configured with the server. Default setting: Off. 4 Operation Operation is performed directly on the device or on a connected extension. i If operation takes place with radio transmitters, please observe the radio transmitter instructions. Switch light o Press button for less than 0.4 seconds. The light is switched on or off. In combination with inserts for dimming, switch-on takes place at the saved switch-on brightness. Status-LED (4) lights up: output is switched on. Status-LED (4) off: output is switched off. i In the case of the HVAC insert, only the output Kanal 1 is switched, whilst the output HLK switches according to the output Kanal 1 (see operation manual of the insert). Adjust the brightness Button is combined with an insert for dimming. Light is switched on. o Press top button for longer than 0.4 seconds. The light gets brighter up to maximum brightness. o Press bottom button for longer than 0.4 seconds. Light gets darker to minimum brightness. i Push-button: the light becomes brighter up to maximum brightness, remains there briefly and becomes dimmer down to minimum brightness, remains there briefly and becomes brighter again. This process repeats for as long as the push-button remains pressed. 32582712 10499459 15.07.2016 2/10

Switch light on with minimum brightness Button is combined with an insert for dimming. o Press button at bottom for longer than 0.4 seconds. Light is switched on at minimum brightness. i If the button or 2-wire extension is pressed at the top or the push-button is pressed for longer than 0.4 seconds, then the light is switched on to minimum brightness and then brighter. Save switch-on brightness Button is combined with an insert for dimming. o Set light to the required brightness. o Press button over entire surface for longer than 4 seconds. Switch-on brightness is saved. For confirmation the lighting switches off briefly and then on again to the saved switch-on brightness. i An push-button cannot be used to save the switch-on brightness. 5 Information for electrically skilled persons 5.1 Fitting and electrical connection DANGER! Electrical shock when live parts are touched. Electrical shocks can be fatal. Before carrying out work on the device or load, disengage all the corresponding circuit breakers. Cover up live parts in the working environment. Connecting and fitting the device To ensure good transmission quality, keep a sufficient distance from any possible sources of interference, e.g. metallic surfaces, microwave ovens, hi-fi and TV systems, ballasts or transformers. The flush-mounted insert is correctly fitted and connected (see instructions for flush-mounted insert). o Fit radio button (3) and frame (2) on flush-mounted insert (1). o Switch on mains voltage. o Carry out commissioning (see Commissioning chapter). 5.2 Commissioning i DANGER! Electrical shock when live parts are touched. Electrical shocks can be fatal. During commissioning, cover the parts carrying voltage on radio transmitters and actuators and in their surrounding area. The button can also be commissioned with server as an alternative to the commissioning described here. Connecting with radio transmitter Load is switched off. o Press button over entire surface for longer than 4 seconds. i Switch inserts switch the load on until the Status LED flashes. The status LED (4) flashes after 4 seconds. The button is in programming mode for approx. 1 minute. o Switch radio transmitter to programming mode as well (see radio transmitter instructions). 32582712 10499459 15.07.2016 3/10

o i i Trigger telegram on the radio transmitter (see instructions of the radio transmitter). The status LED lights up for 5 seconds. The button is connected to the radio transmitter. The button and radio transmitter exit the programming mode automatically. If the status LED of the button flashes 3 times at 1-second intervals for approx. 5 seconds, then the programming operation was not successful. All the memory locations in the button or radio transmitter are occupied. All On and All Off buttons of a radio transmitter are connected to the actuator automatically as soon as the first connection to a radio transmitter takes place. Scene buttons must be connected separately. Disconnecting connection to a radio transmitter o Carry out the same steps as when connecting (see Connecting to radio transmitter). The status LED (4) flashes quickly for 5 seconds. The button is disconnected from the radio transmitter. The button and radio transmitter exit the programming mode automatically. i If there several connections or scene buttons for a radio transmitter, all connections must be disconnected individually. i All On and All Off buttons of a radio transmitter are disconnected automatically as soon as the last connection to the radio transmitter is disconnected. Manual disconnection is not possible. Resetting button to the default setting All connections to radio transmitters are disconnected and parameters are reset to default setting. i The connections in the radio transmitters are preserved and must be deleted separately. Load is switched off. o Press button over the entire surface for at least 20 seconds. i Switch inserts switch the load on until the Status LED flashes. The status LED flashes after 4 seconds. After 20 seconds the status LED flashes faster. o Release the button and press it briefly and fully once again within 10 seconds. The status LED flashes more slowly for approx. 5 seconds. The button is reset to default setting. 6 Appendix 6.1 Technical data Ambient temperature -5... +45 C Radio frequency 868.0... 868.6 MHz Transmitting range in free field typ. 100 m Transmission capacity max. 20 mw Receiver category 2 The device parameters can be changed with the server: Settings window Device settings Parameters Manual commissioning Setting options, Basic setting Explanations Blocks manual commissioning for the device channel. Note: In the "Off" setting, the device cannot be reset to the factory setting. 32582712 10499459 15.07.2016 4/10

Allow extension unit operation Settings, channel Parameters Manual commissioning Operating mode Setting options, Basic setting Normal operation Continuous on Continuous off Basic setting: Normal Operation Prevents operation via wired extensions. Explanations Blocks manual commissioning for the device channel. Note: In the "Off" setting, the device cannot be reset to the factory setting. Normal operation The output can be operated with radio transmitters, with the button and with a connected extension. Continuous on The output switches to continuously "On". All operations of radio transmitters, of the button and of connected extensions are ignored. Continuous off The output switches to continuously "Off". All operations of radio transmitters, of the button and of connected extensions are ignored. Local Operation Manual switch-off of the runon time Basic setting: Off Switch-on brightness 1...100 % Basic setting: 100 % Blocks the output for operation using the button. Allows manual switch-off of a running run-on time. If the parameter is switched off, then a switch-off command will also switch the actuator on. This parameter is directly connected to the "Run-on time" parameter. During brief operation, the output switches on at the set switch-on brightness. Note: If the value is above the set maximum brightness or below the minimum brightness, then the system will switch to the appropriate limit value. 32582712 10499459 15.07.2016 5/10

Switch-on delay Switch-off delay Dim up ramp Dim down ramp Dimming adjustment time Run-on time Behaviour after the end of the disabling function 0 s 24 h Basic setting: 0 s 0 s 24 h Basic setting: 0 s 0 s 24 h Basic setting: 0 s 0 s 24 h Basic setting: 0 s 1 60 s Basic setting: 4 s 0 s 24 h Basic setting: 0 s On Off no change Last value Basic setting: No change The load switches on after a delay. Repeated switch-on commands restart the delay time. If the load has not yet been switched on due to the delay when a switch-off command comes, then the load will remain off. The load switches off after a delay. Repeated switch-off commands restart the delay time. If the load has not yet been switched off due to the delay when a switch-on command comes, then the load will remain on. Time between switch-on and reaching switch-on brightness. The light is switched on at minimum brightness and then dimmed to the switch-on brightness. Note: If scenes are recalled or switching uses logic modules, the switch-on brightness is approached using so-called soft dimming (not configurable). Time until reaching minimum brightness in case of switching off (short operation). The light is dimmed to minimum brightness and then switched off. Note: If scenes are recalled or switching uses logic modules, the system switches off directly. Time from minimum brightness until reaching maximum brightness (dimming speed). As soon as a run-on time has been entered, the actuator will no longer remain on permanently, but only for the length of the run-on time. The run-on time is restarted if actuation is repeated. This parameter is directly connected to the "Manual switch-off of run-on time" parameter. Behaviour of the output when a block is removed. 32582712 10499459 15.07.2016 6/10

Manual saving of the scene values Behaviour on voltage return On Off Last value Configured brightness Basic setting: Off Brightness on voltage return 0...100 % Basic setting: 100 % Switch-off warning Basic setting: Off Priority, lock-out protection 0...4 Basic setting: 1 Priority, restraint 0...4 Basic setting: 2 Priority, wind alarm 0...4 Basic setting: 3 Priority, sun protection 0...4 Basic setting: 0 Disables the saving of the current brightness value as scene value in an actuator for a command via a transmitter. Defines the behaviour of the output after voltage return. Brightness value, set by the output after voltage return (mains voltage). The parameter "Behaviour after voltage return" must be set to "Configured brightness". Note: If the value is above the set maximum brightness or below the minimum brightness, then the system will switch to the appropriate limit value. If the switch-off warning is active, then, during switch-off, the systems dims to minimum brightness within 30 seconds and only then switches off. If the parameter "Dim down ramp" is configured as longer than 30 s, then the length of the dim down ramp is applied. If, during the dim down operation, another command is given, e.g. switch on or scene recall, then the switchoff warning stops and the command is executed. A switch-off command restarts the time for the switch-off warning. Specifies the priority for recalling and removing a scene of type Lock-out protection for the channel. Note: 1 is the highest priority and 4 the lowest. 0 means no priority. Specifies the priority for recalling and removing a scene of type Restraint for the channel. Specifies the priority for recalling and removing a scene of type Wind alarm for the channel. Specifies the priority for recalling and removing a scene of type Sun protection for the channel. 32582712 10499459 15.07.2016 7/10

Priority, twilight 0...4 Basic setting: 0 Switch off brightness overshoot Switch on brightness undershoot Basic setting: Off Minimum brightness 1...67 % Basic setting: 5 % Maximum brightness 75...100 % Basic setting: 100 % Hotel function Basic setting: Off Specifies the priority for recalling and removing a scene of type Twilight for the channel. Allows automatic switch-off according to the brightness. If the parameter is On, then the light controller switches off automatically when the brightness setpoint is greatly exceeded. Note: This parameter is not yet active, as a light controller has not yet been implemented. Allows automatic switch-on according to the brightness. If the parameter is On, then the light controller switches on automatically when the brightness setpoint is greatly undershot. We recommend only using the parameter in connection with the parameter "Switch-off on brightness overshoot". Note: This parameter is not yet active, as a light controller has not yet been implemented. Specifies the minimum settable brightness. Note: If parameters or scene values are set to a level lower than the minimum brightness, then the system will dim to minimum brightness. Specifies the maximum settable brightness. Note: If parameters or scene values are set to a level higher than the maximum brightness, then the system will dim to maximum brightness. If the hotel function is activated, the system will dim to 20 % brightness when a switch-off command is made. Switch-off is only possible with a forced position command. Note: If the minimum brightness is set to greater than 20 %, then the system dims to the set minimum brightness when the hotel function is activated. 32582712 10499459 15.07.2016 8/10

Operating hours 0...65535 Basic setting: Current value The time is counted during which the load is physically switched on. This parameter can be reset to "0", for example after exchanging the load. The Reset button is used to reset the meter to "0". The device must be programmed to apply the change. Information window In the Information window, the load can be controlled and the information about the device can be displays. Display value Current dimming value Load state Restraint Operating hours Explanations The load can be dimmed using the slider or a brightness value entry. The load can be switched on or off. Display of forced position status. Display of the operating hours since the last restart in the Settings window Einstellungen. 6.3 Troubleshooting Push-button as extension, dimming operation stops at minimum brightness. Cause 1: Minimum brightness parameter was changed with the server. Cause 2: Hotel function parameter is activated. Set the minimum brightness parameter to the smallest value. Deactivate the hotel function parameter. Use a 2-wire extension insert. Push-button as extension, only switching and dimming brighter are possible. Cause: Maximum brightness parameter was changed with the server. Set the maximum brightness parameter to the largest value. Use a 2-wire extension insert. 6.4 Accessories Operation with all System 2000 flush-mounted inserts for switching or dimming. Gira Giersiepen GmbH & Co. KG hereby declares that the radio system type Order No. 5490.. corresponds to the directive 2014/53/EU. You can find the full article number on the device. The complete text of the EU Declaration of Conformity is available under the Internet address: www.gira.de/konformitaet 6.6 Warranty The warranty follows about the specialty store in between the legal framework as provided for by law Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical specialist trade). They will forward the devices to the Gira Service Center. 32582712 10499459 15.07.2016 9/10

Gira Giersiepen GmbH & Co. KG Elektro-Installations- Systeme Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel +49(0)21 95-602-0 Fax +49(0)21 95-602-191 www.gira.de info@gira.de 32582712 10499459 15.07.2016 10/10