Bracket guide LK Radiator fixture Uni LK Radiator fixture Uni c/c 40 (Article no. 481 43 92) LK Radiator fixture Uni c/c 50 (Article no. 481 44 03) LK Pipe Pole (Article no. 481 43 91, 481 43 90) Used to produce a neat and secure vertical piping attachment to radiators on plastic cast concrete slabs. The fixture is mounted to an edge beam or building structure/form board. The fixture can be reused at the next work site. LK Pipe Pole is used to produce a neat and secure vertical pipe connection to e.g. radiators for assembly on floor slabs. LK Pipe Pole is available in two designs, double with c/c 40 between holes and quattro with two x c/c/ 40. (40-50-40) LK Pipe Pole can be reused. An example of installation with LK Radiator fixture UNI c/c 40. An example of installation with LK Pipe Pole. 1
LK Manifold Stand (Article no. 241 78 19) LK Cabinet Stand (Article no. 241 88 94) LK Manifold stand be used as an aid when securing manifolds. The stand also includes two sleeve pipes which prevent the legs getting stuck in the concrete. The stand is reusable. LK Cabinet Stand is used for temporary fixing/hanging of LK Manifold Cabinet. The stand also includes four pole clips complete with bolts and two sleeve pipes which prevent the legs getting stuck in the concrete. The stand is reusable. An example of installation with LK Manifold Stand. An example of installation with LK Cabinet Stand. 2
LK Legs for Manifold Cabinet UNI (Article no. 187 82 02) LK Fixing Plate Pipe-in-Pipe 25 (Article no. 188 11 05) Legs for aiding assembly of LK Manifold Cabinet UNI. May well be used on precast concrete floor slab. Supplied with 4 x self tapping screws and sealing washers to fix to the manifold cabinet. The fot has a 6 mm pre-drilled hole intended for metal nail plug or bolt etc. (not supplied). In cases where the legs does not provide proper fixation of the manifold cabinet, it should also be fixed in the wall construction. Used to produce a straight and precise pipe installation to manifolds. Assembled with the aid of 2 Ø 10 mm reinforcement bars which are hammered into the ground. The fixing plate is fitted with 10 st pairs of holes dim. 25 mm intended for LK Manifold Cabinet UNI 550. The fixing plate has cut markes to fit LK Manifold Cabinet UNI UNI 350. The fixing plate can be disassembled without having to disconnect the manifold, and the fixing aid can be reused at the work site. An example of installation with LK Legs for Manifold Cabinet UNI. An example of installation with LK Fixing Plate Pipe-in-Pipe 25. 3
LK Bend support UNI - Floor (Article no. 481 43 81) LK Bend support UNI - Wall (Article no. 481 43 80) Used to secure pipes in floors. Fits P-i-P dim. 16 and 20. The pipes are spaced at c/c 40. The bracket is screwed or nailed to the floor slab. LK Bend Support UNI-Floor is combined with LK Bending Support UNI-Wall (Article no. 481 43 80) for example, to connect radiators to walls. LK Bend Support UNI-Wall combines with LK Bend Support UNI-Floor (Article no. 481 43 81) for exampe to connect radiators to walls. An example of installation with LK Bend Support UNI-Floor and LK Bend Support UNI-Wall. An example of installation with LK Bend Support UNI-Wall and LK Bend Support UNI-Floor. 4
LK Connection box (Article no. 187 23 96, 187 25 39) LK Pipe Holding Nail (Article no. 241 94 86) LK Connection box is used as an economy mould when embedding P-i-P in concrete slabs. The box comes in two different designs, either with holes on the shorter sides or with holes on all four sides. After embedding the pipe can be exposed again if required for connection. Intended for fixing pipes with outer diameters up to 63 mm to insulation. An example of installation with LK Connection box. An example of installation with LK Pipe Holding Nail. 5
LK Nail Clips (Article no. 381 05 13, 381 05 14) LK Nail Clip 16-63 (Article no. 381 05 85) Intended for securing conduits 25 and 34 to concrete constructions. Nail Clips are hammered into an 8 mm hole. The clips come in a single or double design. Intended for fixing pipes and conduits dimension 16 to 63 mm to concrete. Nail Clips are hammered into an 8 mm hole. Supplied with cable ties. An example of installation with LK Nail Clips. An example of installation with LK Nail Clip 16-63. 6
LK Radiator Bend Support, for installation to radiators (Article no. 481 43 67) LK Plastic Clip For Sleeve Pipe For conduit 25 mm (Article no. 188 07 62) For conduit 34 mm (Article no. 188 07 63) Used for pipe exits from the floor with 25. dim conduits. LK Radiator Bend Support is screwed or nailed to building structures. May be joined by c/c distance 40 or 50 mm. For fixing conduits to building structures. Clips are available in dimensions 25 or 34. The clip has two pre-mounted screws, torx 20. An example of installation with LK Radiator Bend Support. An example of installation with LK Plastic Clip For Sleeve Pipe 25 mm. 7
LK Metal Clip for Sleeve Pipe 25, coil For sleeve pipes 25 mm (RSK 188 18 62) LK Wall Support (Article no. 188 06 82) For attachment of sleeve pipes to building structure. The metal clip is available in dimension 25. The metal clip is on coils that are sold in cartons. The metal clip is cut to the desired length/number and designed so that the conduit pipe does not slide. The metal clip can be mounted with both screw and nail gun. Note! Distance between the cold and hot tap water should be considered. For fixing 25 mm conduit in straight leadthrough in wall stud or wall board. Max stud thickness 70 mm. Supplied with fixing plate. An example of installation with LK Metal Clip for Sleeve Pipe 25, coil. An example of installation with LK Wall Support. 8
LK Conduitprotection For conduit 25 mm (RSK 188 84 83) For conduit 34 mm (RSK 188 84 84) LK Fixing Plate For conduit 25 mm (RSK 187 22 16) For conduit 34 mm (RSK 187 05 74) Protection of conduit passing through the steel stud with a maximum thickness of 3 mm. For Conduitprotection 25 use the hole saw 32 mm For Conduitprotection 34 use the hole saw 43 mm. Fixing Plate plastic, for securing conduit pipes laid in wooden joists, stud walls etc. Buttoning fixation plate around the conduit so that it locks into a groove. The fixing plate can easily be installed on both sides of the stud to lock the conduit in both directions. Available for 25 mm conduit. Available for 34 mm conduit. An example of installation with LK Conduit protection 25 An example of installation with LK Fixing Plate 25 9
LK Fixing Plate For conduit 25 mm (RSK 188 21 50) For conduit 34 mm (RSK 188 21 49) LK Angle Wall Box Bracket - 1 (Article no. 187 73 99) Fixing Plate metal, for securing conduit pipes laid in wooden joists, stud walls etc. Mount the fixing plate in a groove on the conduit. Install the fixing plate with a screw in the joist. Available for 25 mm conduit. Available for 34 mm conduit. LK Angle Wall Box Bracket - 1, steel for fixing wall box UNI into the side of the joist. May also be used for LK Angle Wall Bracket Grip. An example of installation with LK Fixing Plate 25. An example of installation with LK Angle Wall Box Bracket -1. 10
Stud walls, steel or wooden studs LK Wallbox UNI Push Clamp (Article no. 188 11 04) LK Wall Fixture 2 x c/c 40 (Article no. 187 43 70) For rear installation of LK Wallbox UNI Push for example in Wet-Room-Wall 2012 (Safe Water-wall). Allows mounting offset from the holes for the wallbox shank. LK Wall Fixture 2 x c/c 40, mounted to joists or nogging piece. Note! The wall fixture must be supplemented with nogging piece alternatively Wet-Room-Wall 2012 (Safe Water-wall). An example of installation with LK Wallbox UNI Push Clamp. An example of installation with LK Wall Fixture 2 x c/c 40. 11
LK Drain Fixture 2 x 40 (Article no. 187 43 69) LK Angle Wall Support 160 (Article no. 187 22 27) LK Drain Fixture 2 x c/c 40 is mounted in LK Angle Wall Support 160. Drainage dim. 50 can be attached with the aid of LK Drain Fixture. LK Angle Wall Support 160 is mounted to wooden or steel studs. The rail accepts c/c 40 horizontal or vertical, as well as c/c 160. It is also possible to attach three-hole horizontal or vertical wall mounting plates. Note! The wall support must be supplemented with nogging piece alternatively Wet-Room-Wall 2012 (Safe Water-wall). An example of installation with LK Drain Fixture 2 x 40. An example of installation with LK Angle Wall Support 160. 12
LK Angle Wall Support 160 Mini (Article no. 187 68 99) LK Angle Wall Support 40 (Article no. 187 81 74) LK Angle Wall Support 160 Mini is mounted to wooden or steel studs. The rail can be used with c/c 80 horizontal or vertical, as well as c/c 160. Note! The wall support must be supplemented with nogging piece alternatively Wet-Room-Wall 2012 (Safe Water-wall). LK Angle Wall Support 40 is mounted to wooden or steel studs. The Wall Support can be used with c/c 40 horizontal or vertical, as well as c/c 160. Note! The wall support must be supplemented with nogging piece alternatively Wet-Room-Wall 2012 (Safe Water-wall). An example of installation with LK Angle Wall Support 40. An example of installation with LK Angle Wall Support 40. 13
LK Angle Wall Support 150 (Article no. 187 22 30) LK Wall Support Flex Wallbox UNI Push (RSK 188 22 03) LK Angle Wall Support 150 is mounted to wooden or steel studs. Wall mounting plates c/c 150 can also be attached to the wall support. It is also possible to use the wall support where the piping protrudes from the wall by c/c 50 mm, e.g. for connection to floor-mounted manifolds. Note! The wall support must be supplemented with nogging piece alternatively Wet-Room-Wall 2012 (Safe Water-wall). LK Wall Support Flex Wallbox UNI Push mounted against a wall stud with the c/c distance of 300 mm, 450 mm or 600 mm. Alternatively in steel studs with c/c 450 mm. Adjustable c/c measurement for pipe oulet. Comes with two brackets for the installation of two wallboxes. Note! The wall support should be supplemented with wet room wall according to Swedish industry rules of safe water installation. An example of installation with LK Angle Wall Support 150. An example of installation with LK Wall Support Flex Wallbox UNI Push. 14
LK Wall Support Wallbox UNI Push For c/c 160 (Article no. 188 07 42) For c/c 150 (Article no. 188 07 43) LK Wall Support CC75/150 Wallbox UNI Push (RSK 188 22 95) LK VWall Support Wallbox UNI Push is mounted in wooden studs with with a c/c distance of 300 mm or 450 mm. The stud must be jacked out 5 mm to provide space for the plate reinforcement profile. For pipe exits c/c 160, use plate 188 07 42. For pipe exits c/c 150, use plate 188 07 43. Note! The wall support must be supplemented with nogging piece alternatively Wet-Room-Wall 2012 (Safe Water-wall). For mounting the LK Wallbox UNI Push in wooden studs with a c/c distance of 600 mm. The studs must be jacked out with 8 mm. For pipe outlets c/c 150 mm. The wallbox is mounted to the plate with the included screws. There is also screws included to mount the plate to the studs. Note! The wall support must be supplemented with Wet-Room-Wall 2012 (Safe Water-wall). An example of installation with Wall Support Wallbox UNI Push c/c 160. An example of installation with LK Wall Support Wallbox UNI Push. 15
LK Mounting Tool, concrete (RSK 188 23 28) The bend support is designed for use with LK Wall Box for concrete. To be installed with nail on rear or front wall insert. The plate is reversible in order to install LK Wall Box for concrete with c/c 150 or 160 mm. The bend support has a centre hole for fixation of a 50 mm drainpipe. The plate also has a hole for clamping the pipe. Installationsexempel med LK Montagefixtur betong. 16