Saturation of Active Loop Antennas

Similar documents
Trees, vegetation, buildings etc.

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

INTRODUCTION TO CONDUCTED EMISSION

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

AC Wire Carrier Current Devices (Unintentional Radiators)

Effectively Using the EM 6992 Near Field Probe Kit to Troubleshoot EMI Issues

Measurement and Analysis for Switchmode Power Design

Loop & Magnetic Field Coil

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

Calibration and Validation for Automotive EMC

Switched Mode Power Supply Measurements

Radiated emission is one of the most important part of. Research on the Effectiveness of Absorbing Clamp Measurement Method.

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards

Techniques to reduce electromagnetic noise produced by wired electronic devices

Australian/New Zealand Standard

SCHWARZBECK MESS - ELEKTRONIK An der Klinge 29 D Schönau Tel.: 06228/1001 Fax.: (49)6228/1003

Appropriate methods to analyse Power Conversion Harmonics

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

Electromagnetic Compatibility

Alternative Radiated Emission Test Methods Progress Achieved in IND60 Project

Large E Field Generators in Semi-anechoic Chambers for Full Vehicle Immunity Testing

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 2.8GHz.

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCE EMITTED FROM TELECOMMUNICATIONS EQUIPMENT

Signal Detection with EM1 Receivers

Spectrum Analyzer. EMI Receiver

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

The Value of Pre-Selection in EMC Testing. Scott Niemiec Application Engineer

EMC Near-field Probes + Wideband Amplifier

Table of Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient (EFT) 3 Electromagnetic Interference

T + T /13/$ IEEE 236. the inverter s input impedances on the attenuation of a firstorder

Reducing Uncertainty in EMC Measurements

Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

Ileana-Diana Nicolae ICMET CRAIOVA UNIVERSITY OF CRAIOVA MAIN BUILDING FACULTY OF ELECTROTECHNICS

EMC ANECHOIC CHAMBERS 5-METER CHAMBERS

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

Test and Measurement for EMC

Predicting Module Level RF Emissions from IC Emissions Measurements using a 1 GHz TEM or GTEM Cell A Review of Related Published Technical Papers 1

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

A GTEM BEST PRACTICE GUIDE APPLYING IEC TO THE USE OF GTEM CELLS

Course Introduction Purpose Objectives Content Learning Time

Laboratory Accreditation Programmes

MIL-STD 461F Results for M&A Technology Companion epad Computer

Characterization of Integrated Circuits Electromagnetic Emission with IEC

PMM 7010 EMI RECEIVERS. The EMI Receiver with built-in LISN

AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT

Advanced Test Equipment Rentals ATEC (2832)

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

Downloaded from 1. THE FOLLOWING PAGES OF MIL-STD-462D HAVE BEEN REVISED AND SUPERSEDE THE PAGES LISTED:

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

Practical Considerations for Radiated Immunities Measurement using ETS-Lindgren EMC Probes

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

FISCHER CUSTOM COMMUNICATIONS, INC.

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

POWER FACTOR CORRECTION AND HARMONIC CURRENT REDUCTION IN DUAL FEEDBACK PWM CONTROLLED AC/DC DRIVES.

Performance Evaluations and Comparative Electromagnetic Compatibility Measurements on Compact Fluorescent Lamps

Specification for Conducted Emission Test

Conducted emission pre compliance measurements

Test Plan for Hearing Aid Compatibility

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

ELEC 0017: ELECTROMAGNETIC COMPATIBILITY LABORATORY SESSIONS

External Drive Hardware

DF Antennas - Datasheet. Datasheet

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

Todd H. Hubing Michelin Professor of Vehicular Electronics Clemson University

MEASUREMENTS OF COUPLING THROUGH BRAIDED SHIELD VIA NEW CONDUCTED IMMUNITY TECH- NIQUE

In late 2011, The International Standards

Investig&ion of the Theoretical Basis for Using a 1 G& TEM Cell to Evaluate the Radiated Emissions from Integrated Circuits

Emerging Standards for EMC Emissions & Immunity

ANSI-ASQ National Accreditation Board/ACLASS

The Causes and Impact of EMI in Power Systems; Part 1. Chris Swartz

Technical Criteria for the Accreditation Of Electromagnetic Compatibility (EMC) And Radio Testing Laboratories

Conducted emission pre compliance measurements

Preliminary Design and Development of Open Field Antenna Test Site

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

esa Space Station Electromagnetic Emission and Susceptibility Requirements International Space Station Revision C May 31, 1996 SSP Revision C

Comparison of IC Conducted Emission Measurement Methods

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

Radiated Spurious Emission Testing. Jari Vikstedt

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

System description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7

SERIES K: PROTECTION AGAINST INTERFERENCE

FlexRay Communications System. Physical Layer Common mode Choke EMC Evaluation Specification. Version 2.1

TEST REPORT... 1 CONTENT...

IEEE EMC Society Standards Development Committee Recommendations on the Resolution of Specific

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR

Potential Impacts of khz Harmonic Emissions on Smart Grid Communications in the United States

EMC and Variable Speed Drives

Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017

For the National Voluntary Laboratory Accreditation Program

FUNDAMENTALS OF EMC. Candace Suriano John Suriano

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

RADIOMETRICS Midwest Corporation

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

EMC / FIELD STRENGTH Test receivers. Fast and straightforward: diagnostic and precompliance measurements with the R&S ESRP

ANNEX TO NPL CERTIFICATE FOR LOG-PERIODIC DIPOLE ARRAY ANTENNAS

Transcription:

Saturation of Active Loop Antennas Alexander Kriz EMC and Optics Seibersdorf Laboratories 2444 Seibersdorf, Austria Abstract The EMC community is working towards shorter test distances for radiated emission measurements in the frequency range from 9 khz to 3 MHz. This would reduce the cost for testing dramatically since typical absorber lined shielded rooms can be used for magnetic field strength measurements. The reduction of the test distance will lead to higher emission limits. In combination with pulsed signals commercially available active loop antennas are not suitable due to insufficient dynamic range. Measuring a 2 % duty cycle signal will increase the dynamic range by 3 db. Pulsed signal have to be taken into consideration because pulse width modulation is one of the possibilities to control power in wireless charging applications. Keywords magnetic field measurement; active loop antenna;amplifier saturation; emission measurement; saturation indication I. INTRODUCTION Active loop antennas are widely used for radiated emission testing in the frequency range from 9 khz to 3 MHz; applicable standards are CISPR 11 [1], CISPR 14-1 [2] and ANSI C63.4 [3]. They are required since emission limits are low due to a historical test distance of 3 m. This large test distance is inconvenient for the test labs due to large required space outside the building. The use of anechoic environments is established for emission measurement since more than two decades with several good reasons. So the EMC community is seeking for a test distance of m or even 3 m with the advantage that emission tests are carried out in facilities which are built for the range above 3 MHz. Ongoing activities in several committees of CISPR support this demand. With decreasing distance the emission limits have to be increased to protect radio services at the same level. In principle an active antenna is a combination of a passive antenna and a preamplifier. For EMC measurements preamplifier are generally not recommended due to overload. In CISPR 16-1-1 [4] extensive discussion of advantages and disadvantages can be found. In the relevant standards no specification of loop antennas can be found, except a maximum size requirement. Overload and saturation effects of active antennas are barely mentioned; only a reminder that saturation indicator lamps shall be observed is found. Typical equipment with emissions below 3 MHz is induction cooking appliances, but the number is growing with large TV sets and wireless charging devices. II. EQUIPMENT UNDER TEST Although induction cooking appliances and wireless charging stations serve completely different purposes, the systems have a similar topology, see Fig. 1. After the AC power from the mains is rectified to DC, high frequency power is generated by an inverter. A strong magnetic field is generated by the working coil. In case of an induction cooking appliance the magnetic field is absorbed by a suitable pan and transformed into heat. Wireless charging systems have a second coil, which feeds the charger for the batteries. Depending on the application the transferred power reaches from a few watts for smart phones to several kilowatts for electric vehicle. The frequency range of the inverter ranges from 24 khz for induction cooking [5], 85 khz for Wireless Electric Vehicle Charging (WEVC) [6] to khz to 5 khz for wireless power transfer (WPT) for smart phones [7]. Common for all systems is a control functionality of the transferred power. There are several possibilities to perform this task: Change of the DC output voltage of switched-mode power supply. Change of the inverter frequency in resonant systems. By detuning the circuit the current in the working coil and so the power is reduced. Pulse-width modulation of the inverter. Pulse-width modulation is the most interesting in the view of an EMC engineer. This means the generated disturbance is not a signal with harmonics but a pulsed signal. WPT systems [7] specify a duty cycle from 2 % to 5 %. Fig. 1. System topology of EUT from [5]

III. AVAILABLE ANTENNAS A. Specification Since decades several manufacturers offer active loop antennas. They differ in diameter and in dynamic range, see Tab. 1. Specifications of the antenna diameter can be found at CISPR 16-1-4 [8]. The loop antenna shall fit into a square with 6 cm diameter. Requirements on dynamic range are not given. Typically the upper end of the dynamic range is defined by the 1 db compression point. Most of the antennas have an indication for saturation. Model TABLE I. Loop diameter [cm] COMMERCIALLY AVAILABLE ANTENNAS Specifications Maximum field strength [dbµa/m] Saturation indication #1 5 78.5 No #2 3 82.5 Yes #3 6 88.5 Yes #4 49 78. Yes #5 6 88.5 Yes #6 59 88.5 No In this paper measurements with model #1 and #2 are presented. B. Calibration Antenna calibration procedures can be found at CISPR 16-1-6 [9], ARP 958 [] and IEEE Std. 291 [11]. All of them use signals for calibration and do not contain procedures to quantify saturation effects. Also methods to proof the effectivity of saturation indicators are not present. IV. PROPERTIES OF PULSED SIGNALS The properties of pulsed signals can be derived from the shape, see Fig. 2. The duty cyle D is the ratio between the active part T and the period P D = T P < D < 1 (1) Since loop antennas are not sensitive to static magnetic fields, signals do not have a DC component. V+ V- T P Fig. 2. Shape of a pulsed signal So the area below the positive and negative pulse must be equal The RMS power is calculated by V + D = V (1 D) (2) P RRR = V + 2 D + V 2 (1 D) (3) EMI receivers display the spectrum of the output voltage of the antenna. The fourier transformation is used to calculate the frequency domain X k from the time domain x n. The fundamental frequency is the spectral line where k=1. To plot the power versus duty cycle normalization is required. In active antennas typically class AB amplifier or instrumentation amplifier are used. Their output swing is symmetrical around ground. Compression effects influence the output signal if V+ or V- overruns the output swing. Fig. 3 shows the RMS power and the power of the fundamental frequency versus duty cycle of a pulsed signal of V+ = 1 V. Additionally the power of the sine wave with 1 V peak magnitude is plotted. The RMS power is always larger than the power of the fundamental frequency. This is obvious because the harmonics contain the difference in power. At 5 % duty cycle both are above the power. The reason for this is that a rectangular signal contains more energy than a signal of the same peak voltage. With decreasing duty cycle the RMS power drops with db per decade while the power of the fundamental frequency drops with db per decade. For a duty cycle of 2 % the fundamental is 28 db below the signal. This fact is important if pulsed emissions are measured, because this relation is also valid at the compression point. This means if the EMI receiver shows a moderate signal magnitude, the active antenna can already be overloaded. This fact could be easily overlooked by the operator. Fault measurement can occur, if the antenna does not have a saturation indication or if this feature is not used. V. SATURATION EFFECTS Typically the 1 db compression point is published in the datasheet of an active loop antenna. This property is measured with signals where the input power is increased until the gain of the internal amplifier drops by 1 db. The same procedure can be applied with a pulsed signal. In this case the power of the fundamental frequency of the output is measured. Fig. 4. shows the result of a simulation to investigate this effect. The output voltage of the simulated amplifier is limited by a defined voltage. If the voltage is below that the amplifier works in the linear range and no error occurs. Above this (4)

- Level [dbm] - -3-4 Fig. 3. Shape of a pulsed signal -5 Power of -6 RMS of rectangular Power of fundamental -7.1.1 1 Duty Cycle [%] threshold normalized to db saturation occurs. For signals there is a smooth transition between linear range and compression. If a small part of the top of a sine is cut off, the power is not changed dramatically. For pulsed signals the effect of compression starts with a bend at the threshold. Above a linear trace can be observed. To see a 1 db compressed signal the voltage is 2 db above the threshold. For a 1 db compressed pulse the voltage is only 1.1 db above the threshold. This behavior is independent from the duty cycle. To eliminate the effect of saturation the maximum signal should be 2 db below the 1 db compression point. The instrumentation uncertainty of radiated emission measurements above 3 MHz is specified in CISPR 16-4-2 [12]. If this standard is extended to the range below 3 MHz, operation in the linear range is preferred to minimize the uncertainty. Otherwise an additional uncertainty contribution has to be taken into consideration. Compression [db] -.5-1 -1.5-2 -2.5 Pulse -3-3 -2-1 1 2 3 Voltage normalized to threshold [db] Fig. 4. Compression of signals VI. EMISSION LIMITS In CISPR 11 equipment is separated into groups and divided into classes with limits for each test distance, see Fig. 5. Due to this variety there are strong demands on the dynamic range of active loop antennas. The latest edition 6. from 15 is responsible for wireless power transfer for instant power supply and charging purposes as group 2 equipment. Even for signals not all products given in Tab. 1 are suitable for a test distance of 3 m, if a class A group 2 device is measured. For a 2 % duty cycle pulsed signal the situation is worse. The saturation should be at least 28 db above the limit, see Fig. 3. Furthermore amplifiers are more sensitive to compression for pulsed signals. To avoid saturation effects another 2 db must be added, see Fig. 4. This means the antenna should have a dynamic range up to 112 dbµa/m, which cannot be fulfilled by any active antenna. Induction cooking devices are covered by CISPR 14-1 and measured at 3 m distance. The largest limit for such devices is 69 dbµa/m in the frequency range 9 khz to 7 khz. Magnetic field strength [db µa/m] 9 8 7 6 5 4 3 - - -3,1 1 Frequency [MHz] Fig. 5. CISPR 11 emission limits 3 m; class A group 2 3 m; class B group 2 m; class A group 2 3 m; class A group 2 in situ 3 m; class A group 1 in situ 3 m; class A group 2

VII. MEASUREMENTS A test setup used for calibration of loop antennas is given in Fig. 6. An arbitrary waveform generator is used to generate a pulsed signal with a duty cycle from 1 % to 5 %. This signal is amplified and fed to a TEM cell. It is measured with an oscilloscope via attenuators from the cell output. The output of the active loop antenna is measured with an EMI receiver. EMI Fig. 6. Block diagramm of antenna calibration test setup With this setup the 1 db compression points are measured for the active antennas #1 and #2 of Tab. 1, see Fig. 7. The diagram shows the RMS power measured with the oscilloscope and the power of the fundamental frequency measured with the EMI receiver. Additionally the compression point for signals is plotted. a) b) Magnetic field strength [dbµa/m] 95 9 85 8 75 7 65 6 1 RMS Fundamental frequency Both diagrams look similar but have a difference in magnitude of approximately 7 db. The reason for this is the difference in diameter and the gain of the internal amplifier. They show a good agreement with the calculated power in Fig. 3. Minor deviations occur due to measurement uncertainty and due to ringing close to the compression point of antenna #2. So the estimation of the requirement for additional dynamic range, if pulsed signal are measured, is valid. VIII. SATURATION INDICATORS Another important issue is the saturation indicator of active loop antennas. Although the majority of antennas are equipped with such indicators little information is present. Several important questions are not answered by their manufacturers in the data sheets: At which magnetic field strength does the indicator alert the operator? Is there a frequency dependency of this magnetic field strength? When the indicator alerts is the antenna still in the linear range or does compression already occur? Is the indicator sensitive to peak, average or RMS power? How long after a single overload does the indicator show the alert? So the manufacturers are requested to give further information on the principle of the saturation indicator and the proper use. With the test setup of chapter VII it is possible to determine the effectiveness of the indicator. When measuring the compression point the magnetic field strength at which the indicator alerts is also recorded. For antenna #2 this measurement is performed and showed in Fig. 8. The diagram shows the level at which the indicator alerts relative to the 1 db compression point. So the indicator responds at least 2 db below the compression point which means in the linear range of the amplifier. It works wells for pulsed signals with a duty cycle between 1 % and 5 %. If the indicator is sensitive to single pulses was not tested. Also the frequency dependency is out of scope of this paper. -1 Magnetic field strength [dbµa/m] 95 9 85 8 75 7 65 6 1 RMS Fundamental frequency Level [db] -2-3 -4-5 -6-7 -8 1 Fig. 7. Measured compression for pulsed signals of antenna a) #1 b) #2 Fig. 8. Effectivity of saturation indication

IX. COMPRESSION DETECTION AND AVOIDANCE The previous chapter showed that the saturation indication works effectively for pulsed signals. However observing a LED of an antenna inside a shielded room is inconvenient. Therefore the manufacturer offers a fiber optic extension to root the light outside the room. Other products increase the supply current of the antenna to alert the operator. If an antenna does not have a saturation indication the wave shape of the emission must be known. If it is unknown an oscilloscope must be used to see if it is or pulsed signal and to determine the duty cycle. There are limited methods to avoid compression. One is to increase the test distance but this is not an option for the majority of the operators. So switching to another antenna model with larger dynamic range or less sensitivity is one possibility. The easiest method to avoid saturation is to use a passive antenna. The antenna factor of a passive antenna decreases with db per decade for lower frequencies and is flat for higher frequencies, see Fig. 9. Between khz and khz the antenna factor is approximately dbs/m. The dynamic range of an EMI receiver in band B is typically from dbµv to 137 dbµv. This leads to a dynamic range for magnetic field strength measurements from dbµa/m to 147 dbµa/m since cable loss can be neglected in this frequency range. This fits well for class B group 2 equipment for a test distance of 3 m and m. For a test distance of 3 m the dynamic range is insufficient. So passive as well as active loop antennas are required for a laboratory to serve all distances. Antenna factor [db S/m] 4 3 - -,1,1,1 1 Frequency [MHz] Fig. 9. Antenna factor of a passive loop antenna with 6 cm diameter The operator has to keep in mind that a dynamic range up to 112 dbµa/m, see chapter VI, is still required even if a passive loop antenna is used. The reason for this is the design of the preselector of the EMI receiver. The specification of the design is not given by the relevant standard [4], instead the functionality is specified. However manufacturer use similar implementations with a fixed lowpass filter below 15 khz and fixed or tuneable bandpass filter above. Since these bandpass filters are not narrowband, the pulsed signal with several of its harmonics lies on the input of the receiver. The same effect like for active antenna occurs, however it is easier to control the level with the step attenuator. X. OUTLOOK Changes in the test distance for radiated emission measurements and emerging technologies like wireless power transfer will change magnetic field strength measurements in future. Active loop antennas with a large dynamic range are required to fulfill the demands. In future new designs will be switchable from active to passive. Also antennas with a complete front-end with preselector and step attenuator are possible [13]. REFERENCES [1] CISPR 11, Industrial, scientific and medical equipment Radiofrequency disturbance characteristics Limits and methods of measurement, Edition 6., 15-6, IEC [2] CISPR 14-1, Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Part 1: Emission, Edition 5.2, 11-11, IEC [3] ANSI C63.4-14, American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 khz to 4 GHz, IEEE, 3 Park Avenue, New York, USA, 14 [4] CISPR 16-1-1, Specification for radio disturbance and immunity measuring apparatus and methods Part 1-1: Radio disturbance and immunity measuring apparatus Measuring apparatus, Edition 4., 15-9, IEC [5] Fairchild Semiconductor, AN-912 Induction Heating System Topology Review, www.fairchildsemi.com, Rev. 1..4, [6] Keith Mallinson, WEVC Requires Many Technologies with Well- Integrated Systems and Supply, WiseHarvor Spotlight Report, www.wiseharbor.com, 24 th August 15 [7] Wireless Power Consortium, System Description Wireless Power Transfer, Volume 1: Low Power, Part 1: Interface Definition, Version 1.1.2, info@wirelesspowerconsortium.com, June 13 [8] CISPR 16-1-4, Specification for radio disturbance and immunity measuring apparatus and methods Part 1-4: Radio disturbance and immunity measuring apparatus Antennas and test sites for radiated disturbance measurements, Edition 3.1, 12-7, IEC [9] CISPR 16-1-6, Specification for radio disturbance and immunity measuring apparatus and methods Part 1-6: Radio disturbance and immunity measuring apparatus EMC antenna Calibration,Edition 1., 14-12, IEC [] ARP 958, Electromagnetic Interference Measurement Antennas; Standard Calibration Method, SAE International, 4 Commonwealth Drive, Warrendale, PA 1596-1, 1999 [11] IEEE Std. 291-1991, IEEE Standard Methods for Measuring Electromagnetic Field Strength of Sinusoidal Continuous Waves, 3 Hz to 3 GHz, The Institute of Electrical and Electronics Engineers, 345 East 47th Street, New York, 1991 [12] CISPR 16-4-2, Specification for radio disturbance and immunity measuring apparatus and methods Part 4-2: Uncertainties, statistics and limit modelling Measurement instrumentation uncertainty, Edition 2.1, 14-2, IEC [13] D. Festa, A. Gandolfo, R. Azaro, Innovative Field Receiver Based on a New Type of Active Rod Antenna, 15 IEEE Symposium on Electromagnetic Compatibility and Signal Integrity, Santa Clara, CA