SGD-EGC200 «SKAT II» GEOPHYSICAL MULTI-FUNCTION TRANSMITTER

Similar documents
SGD-EEM «MEDUSA» GEOELECTRICAL MULTIFUNCTION RECEIVER

IP-1000М Transmitter

Technical data. General specifications V DC No-load supply current I 0. typ. 50 ma Power consumption P 0

Wireless Transceivers for Fuel Level Sensors RUd-DF-232 RUd-DF-485. Instruction Manual Version # 2.1 VTAS IM

The universal driver for LEDs D-31M

PORTABLE EDDY CURRENT FLAW DETECTOR

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR

SCIENCE AND PRODUCTION COMPANY POWER SUPPLY SOURCES OF DIRECT CURRENT SERIES БП 906 БП 906/24-1(2) БП 906/36-1(2) Certificate

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 700 a at 40 C Mission Time (T M ) L 10

Mars-Energo. Volt/mA Calibrator CALMAR-S. User s manual Edition 3.1

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 700 a at 40 C Mission Time (T M ) L 10

The universal driver for LEDs with built-in cooler DLT-37M

Multiturn absolute encoder

Astra-R Kit Wireless Alarm System Operation Manual

5 Channel Multifunctional PWM Controller. HomLiCon LCH5T. Technical Specifications

БП 906А/24-4КР POWER SUPPLY SOURCES OF DIRECT CURRENT. Certificate НКГЖ ПС. For APP

GFL-1000 User Manual Ground Fault Locator

QL50 Luminescence Sensor

Jet Central Sequencer Plus

DC Electronic Loads 8500 Series

HAWK5000 Operators Manual

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

Multiturn absolute encoder

Studio Broadcast System

LMG500 Getting started. Get in touch

CONTACTLESS READER OPERATION MANUAL. Ver. 1.1

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

Encoder - Absolut 2RMHF-SSI

AMT-07. Amplifier for MID-IR PDs, with built-in cooler

Technical data. General specifications. Linearity error ± 0.1 Electrical specifications Operating voltage U B

Technical data. General specifications V DC Power consumption P 0. 1 W Time delay before availability t v

WaveStation Function/Arbitrary Waveform Generators

PCX-9000 Series Datasheet

ABSOLUTE ROTARY ENCODER SSI

GE Infrastructure Sensing. Druck DPI 841/842. Frequency calibrator and Frequency loop calibrator User manual - K395

7.2 DV1311.L08 and DV1311.L12

Answering frequently asked Questions (Firmware V.107)

DTI-1000 & STS-100/102. Digital Temperature Indicator & STS Reference Sensor

WaveStation Function/Arbitrary Waveform Generators

FAG PRESTO DX. FAG PRESTO-DX preliminary User Manual. FAG GRAPHIC SYSTEMS S.A. 3, rue de la Vigie CH-1003 Lausanne Switzerland

Appendix A: Specifications

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

COD GB / 1.0 RBAND/UMS - RBAND/CSM

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

HZJF-9007 Fully Functional Partial Discharge Inspector USER MANUAL. Huazheng Electric Manufacturing(Baoding) Co.,Ltd

DC Electronic Loads 8500 series

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

DSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.

NON-LINEAR JUNCTION DETECTOR L O R N E T - 24 USER MANUAL

EM 6000 EM 6000 DANTE True bit diversity receiver

TX CONTROLLER Model EM-IP Quick Start Guide

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

MTY (81)

User Manual. ilive 2 Wireless microphone system

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

Preset counters, electronic

TM1600. Circuit Breaker Analyzer System

Precision Delay Your Station In Sync and On Time

RADIOACTIVITY INDICATOR RADIASCAN-501(701) OPERATIONS MANUAL

Absolute Encoders Multiturn

medlab Two Channel Invasive Blood Pressure OEM board EG 02000

Technical data. General specifications. Measurement range min max. 360

Brunata Optuna H. Properties. Counter

DPSI LCD Operating Instructions Version 1.0. Contents

T 160S. User Guide TIME CODE SATELLITE GPS. TIME CODE READER / GENERATOR SMPTE to MTC / MTC to SMPTE MMC /WIRELESS TC. T 160S Version1.

5V SERIES DC LOADS 5V SERIES DC LOADS. Key features:

ST121 SIGNAL IMITATOR TECHNICAL DESCRIPTION AND OPERATING MANUAL

ISOMETER IRDH575. Approvals

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

G5 System Family and Accessories

SVM F22 SVM F27. Calculator for heating or cooling applications. Ultraljudsmätare. Installation Guide. Datablad

ADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK /

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Operating Instructions

Getting Started with TrangoLink

RADIOBAND V3 Programming & Installation Manual

IP 251 Universal Signal Converter SSI parallel RS232 parallel SSI RS232

PWM regulator for electrolysis cell Η 2

Distance sensors. System description. Distance measurement using triangulation

Multifunctional counter tico 772/773/774

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

Technical Information itemp TMT180

Absolute Encoders Singleturn

CIC ENGINEERING 345 CENTER STREET EAST PEORIA, IL PH FAX µmpis Control Software

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website:

MAGNETIC FIELD METER Operator s Manual

БП 906А/24 БП 906А/36

INTRODUCTION CHAPTER 1

20 CHANNELS DIGITAL DELAY GENERATOR

USER MANUAL. EPP Intelligent Positioner Control Unit 1/22.

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

BeeLine TX User s Guide V1.1c 4/25/2005

High-speed programmable attenuator MAT800

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

9/2/2013 Excellent ID. Operational Manual eskan SADL handheld scanner

USERS MANUAL TR-710.

AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics

Transcription:

Research and Production Company Sib Geofiz Pribor SGD-EGC200 «SKAT II» GEOPHYSICAL MULTI-FUNCTION TRANSMITTER Version V4.0 OPERATIONS MANUAL 2012

2 Operation Manual Sib Geofiz Pribor

SGD-EGC200 «SKAT II» 3 CONTENTS 1. Product overview 4 1.1. Introduction 4 1.2. Design and operation 6 1.3. Preparation for use 8 1.4. Operating procedure 9 2. Technical specifications 11 3. Configuration 12 Notes 13 Sib Geofiz Pribor

4 Operation Manual 1. PRODUCT OVERVIEW 1.1. Introduction 1.1.1. The geoelectrical transmitter SGD-ECG200 «SKAT II» SGFP 220.00.00-03 (hereinafter transmitter) is designed to create electromagnetic field during geophysical survey. It can produce a stabilized rectangular alternating currents with a duty cycle of 50 or 100% with a wide range of frequencies and current values. 1.1.2. Application area - geophysical exploration by methods of direct current, induced polarization, frequency sounding and other methods. 1.1.3. The geoelectrical transmitter SGD-EGC200 «SKAT II» should not be subjected obligatory certification according to Government Resolution of the Russian Federation dated December 1, 2009 N 982 "About approval of the single list of products subjected to obligatory certification, and a single list of products, which conformity assessment takes the form of acceptance of the declaration of conformity". Sib Geofiz Pribor

SGD-EGC200 «SKAT II» 5 Picture 1. The geoelectrical transmitter SGD-ECG200 «SKAT II» Sib Geofiz Pribor

6 Operation Manual 1.2. Design and operation 1.2.1. The transmitter is made in a metal case on the front panel of which are placed: 1) graphic display VFD or OLED type with a 128x64 pixel resolution; 2) controls; 3) connectors to input power, control the transmitter and output power to the soil. 1.2.2. Graphic display is designed to show the settings menu and operating parameters. 1.2.3. Controls of transmitter are presented by six button of membrane type: ON/OFF - switch on/off the transmitter; START/STOP - start / stop power transmission; ENTER - enter to the submenu, enter to the parameter edit mode of the menu item, exits the parameter edit mode of menu item with saving of its new value; ESC - exit out of the submenu, exit out of the parameter edit menu without saving its new value; - navigating a menu items, making changes in the menu item. 1.2.4. Connectors: 24V - connector for power input; AB - terminals for power out; COMM, GNSS,... - multipurpose connector for an external transmitter control, synchronization and signal from the current sensor. It is not installed in all versions of the transmitter. 1.2.4. Transmitter operates in two basic modes: 1) menu mode; 2) power transmission mode; 1.2.5. In menu mode, on the instrument display is shown the menu of settings. These settings can be changed using the control buttons. 1.2.6. In power transmission mode, the device generates alternating current with a stable amplitude through the terminals AB. In this mode, display will show the preset value of the current and the frequency, amplitude of the load voltage, and load resistance. If the load current corresponds to the set value, then in the top right corner of the display shows the "STAB", otherwise shows " - " and sounds a periodic beep. 1.2.7. The transmitter can synchronize switching current with the leading edge of the external differential signal at the pins 9, 10 of «COMM, GNSS» connector. Also, it can generate a synchronization signal on the same pins. The synchronization mode is defined in the menu item «Sync». All synchronization modes are shown in the following table. Sib Geofiz Pribor

SGD-EGC200 «SKAT II» 7 Item menu Direction for «Sync» 9,10 pins «Input» input Transition from 9(-), 10(+) to 9(+), 10(-) Transition from 9(+), 10(-) to 9(-), 10(+) «Output+» output Transition from 9(-), 10(+) to 9(+), 10(-) «Output-» output Transition from 9(-), 10(+) to 9(+), 10(-) «GNSS+» output Transition from 9(-), 10(+) to 9(+), 10(-) «GNSS-» output Transition from 9(-), 10(+) to 9(+), 10(-) Moment synchronization of current Pin 9, 10 100% duty cicle 50% duty cicle Transition from А(-), В(+) to А(+), В(-) AB current on Transition from А(+), В(- AB current ) to А(-), В(+) off Transition from А(-), AB current В(+) to А(+), В(-) on Transition from А(+), В(- AB current ) to А(-), В(+) off Transition from А(-), AB current В(+) to А(+), В(-) on Transition from А(+), В(- AB current ) to А(-), В(+) off In synchronization mode "GNSS", on the pin 6 of the «COMM, GNSS» connector is present voltage for supply navigation receiver. Sib Geofiz Pribor

8 Operation Manual 1.3. Preparation for use. 1.3.1. Inspect the transmitter and make sure that there is no any mechanical damage. 1.3.2. Apply power to the connector "24V". The assignment of connector pins are shown below: Description Pin number + 20 30 V 2 Ground 3 1.3.3. Connect the feed line or a resistive load to the terminals «A» and «B». 1.3.4. The pin assignment of "COMM, GNSS" connector are shown below: Description Pin number RS232 Tx/RS485 A 1 RS232 Rx/RS485 B 2 Ground 3 Isolated current monitor«+» 4 Isolated current monitor«-» 5 Supply for GNSS receiver 6 External On/Off 7 Ground 8 Synchronization + 9 Synchronization - 10 Attention!!! Direct current power source with output voltage equal to 24 volts should provide sufficient power for the respective operating mode of the transmitter. So for the modes with the highest possible power, for example 750V @ 250 ma, the current consumption can be up to 12A at the minimum supply voltage. Using a lead-acid batteries as a power supply, it is necessary to consider their ability to prolonged impact appropriate currents. This feature will directly depend on the rated capacity of the battery, the charging state, its residual resource and ambient temperature. For all modes of operation of the transmitter, the recommended nominal battery capacity should be at least several times more than the consumption in this mode current. So for operation with a maximum power the capacity of lead-acid batteries should be at least 24 A h. Time of continuous work with such battery and positive ambient temperatures can be about 60 minutes. It`s also necessary to pay attention to the power leads. Wire cross-section and its length should have a minimum voltage drop to the requirable modes. Sib Geofiz Pribor

SGD-EGC200 «SKAT II» 9 1.4. Operating procedure 1.4.1. Power on/off the transmitter is made by briefly pressing on the button «ON/OFF. Within seconds after the transmitter was turn on, the display shows a welcome message with the name of the manufacturer, the product name, version of hardware implementation and software products, the serial number of the product. It is displayed for three seconds, and then the device enters the menu mode. 1.4.2. The menu consists of items of the two types. The first type includes an editable parameter, the second type contains a submenu. The first type is displayed as «name of parameter»+ «value of parameter». The second type is displayed as "name of submenu" + «...». 1.4.3. Navigating a menu items can be done by buttons и. Selected menu item is marked on the display by sign. Navigating to submenu or enter to parameter edit mode of the menu item is called by pressing button «ENTER». Exit of submenu is called by pressing button «ESC». 1.4.4. After enter the parameter edit mode of the menu item (by button «ENTER»), the choice of specified value of current, frequency, duty cicle, display brightness, date and time setting is made by buttons и. Exit of the edit mode with saved the selected value is called by pressing the button «ENTER». Exit out of edit mode of the menu without its change is called by pressing the button «ESC». 1.4.5. Settings menu includes following items: F 4.8828 Hz - frequency of current; I 100 mа - value of output current; Duty 50% - duty cycle of current; «50%»; «100%». F set 4,88Hz - set of frequencies: «4,88Гц»; «50/60Гц». Sync Input - synchronization mode: «No»; «Input»; «Output+»; «Output-»; «GNSS+»; «GNSS». Date and Time... - submenu for date and time setting. 1.4.6. Transition to power transmission mode are called by pressing button «START/STOP». In this mode, the device generates alternating current with a stable amplitude through the terminals AB with the same parameters, which were specified in setup menu. In this mode, current generator created current in АВ line with the same parameters, which were specified in setup menu, and displays following lines constantly: I = 100 mа STAB - selected value of current is stabilized; or I = 100 mа - selected value of current is not stabilized; Sib Geofiz Pribor

10 Operation Manual U = 470 V 62% - amplitude of voltage on the terminals AB and the percentage of the maximum possible value for this current; R = 4.70 kohm - calculated value of the load resistance at the terminals AB. In the case where the device fails to stabilize the current, it will emit short periodic beep. 1.4.7. In the bottom line of display, regardless of operation mode, current time and supply voltage are always shown. In the power transmission mode is also displays a flashing sign of lightning. 1.4.8. Recommended values for output current depending on AB line resistance are shown in table below: Power, W Output current, mа Maximum output voltage, V Resistance range of АВ line, Ohm 200 1 1.000 750.000 2 500 375.000 5 200 150.000 10 100 75.000 20 750 50 37.500 50 20 15.000 100 10 7.500 150 6,6 5.000 200 5 3.750 250 4 3.000 300 650 3,3 2.200 400 500 2,5 1.250 500 400 2 800 600 330 1,6 550 700 280 1,4 400 800 180 1,25 312 900 180 1,1 245 1000 180 1 200 Sib Geofiz Pribor

SGD-EGC200 «SKAT II» 11 2. TECHNICAL SPECIFICATIONS 2.1. Maximum output power - 200 W. 2.2. Rated output current - 1, 2, 5, 10, 20, 50, 100, 150, 200, 250, 300, 400, 500, 600, 700, 800, 900 и 1000 ma. 2.3. Leakage current in feed line in state of the current is switched off - no more than 0,01 ma. 2.4. Maximum output voltage - ± 750 (1500 peak-to-peak) V. 2.5. Relative error of current stabilization - no more than 0,5 %. 2.6. Rise time and fall time (Rload = 1 kohm) - no more than 1,5 microsecond. 2.7. Setup time of current after pressing "start" - no more than 2 seconds. 2.8. Shape of the output current - rectangular pulses of alternating polarity with a pause or no pause. 2.9. Available values of the duty cycle of current - 50%, 100%. 2.10. The number of available frequency sets is two. 2.11. Available frequency values of the first set - 0, 0.019, 0.038, 0.076, 0.152, 0.305, 0.61, 1.22, 2.44, 4.88, 9.76, 19.53, 39.06, 78.125, 156.25, 312.5, 625 Hz. 2.12. Available frequency (period) values of the second set - 0.5, 1, 2, 4, 8, 16, 32 sec. 2.13. Absolute error of frequency current pulses without using a GNSS receiver - ± 1 10-6. 2.14. Relative frequency instability of current pulses without using a GNSS receiver - ± 1 10-6. 2.15. Internal or external synchronization. 2.16. Internal clock and calendar. 2.17. Continuous operation in the operating temperature range. 2.18. Reliability: 1) Mean time to failure, at least 2000 h; 2) Mean life time, at least 6 years; 3) Mean shelf life, at least 3 years. 2.19. Supply voltage range - 20 to 28 V. 2.20. Maximum power consumption in no-load mode - no more 5,5W. 2.21. Maximum current consumption - no more 12 А. 2.22. IP Code according to GOST14254-96 (MEK 529-89 CE I70-1 EN 60529) is IP64. 2.23. Operation temperature range - -40 to +50 С. 2.24. Dimensions - no more than 212 77 235 mm. 2.25. Weight - no more than 2,8 kg. 2.26. Weight of device and special vest with two sealed lead battery«12v, 8.5А h» is not more than 9,5 kg. Sib Geofiz Pribor

12 Operation Manual 3. CONFIGURATION 3.1. Contents of delivery for current generator SGD-EGC200 «SKAT II» SGFP 220.00.00-03 is shown in Table 1. Table 1. Name Item Quality Note DOCUMENTS SGFP 220.00.00-03 RE Transmitter SGD-EGC200 «SKAT II» Operations manual. 1 UNITS SGFP 220.00.00 Transmitter SGD-EGC200 «SKAT II» 1 036 SGFP 220.51.00 Power cable «SUPPLY 24V» 1 1,2 m High-voltage terminal LAS S W HIRSCHMANN 4 «YELLOW» GEO.364.126 ТУ GEO.364.126 ТУ Connector 2RМ22KNU4G3V1 Connector 2RМ22KNU10G1V1 1 1 SGFP 120.71.00 Special vest 1 SGFP 120.72.00 Sealed lead battery«12v, 8.5 А h» SGFP 443.00.00-01 Battery charger SGD-BC3502 Sib Geofiz Pribor

SGD-EGC200 «SKAT II» 13 NOTES Sib Geofiz Pribor

14 Operation Manual NOTES Sib Geofiz Pribor