Low Slope Fastening Solutions Guide

Similar documents
DEKFAST COMMERCIAL ROOFING FASTENERS

Perlok CR 1.2 Base Sheet Fastener Secure Base Sheets to Lightweight Insulating Concrete or Gypsum

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

Perlok CR 1.2 Base Sheet Fastener Secure Base Sheets to Lightweight Insulating Concrete or Gypsum

MULE-HIDE PRODUCTS CO., INC FASTENER GUIDELINES

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

4isofast Product code Page

Fastener Design. Fastener Materials. Coated Corrosion-Resistant Fasteners. Metal Alloy Capped Fasteners

METAL-TO-METAL FASTENERS QUIKDRILL METAL2METAL METAL2METAL HD. Value through the Roof.

TI: Efficient self tapping fasteners into concrete without plugs

Large Diameter Tapcon

FASTENERS QUIKDRILL QUIKGRIP CLIPSCREWS. Value through the Roof.

UL Construction No. 254

LENGTH IDENTIFICATION

REPORT HOLDER: SFS INTEC 1045 SPRING STREET WYOMISSING, PENNSYLVANIA EVALUATION SUBJECT:

SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here)

METAL-TO-WOOD FASTENERS QUIKGRIP METAL2WOOD METAL2WOOD HD METAL2WOOD XD LOPRO 300SS. Value through the Roof.

Stainless Steel Anchors. for Concrete & Masonry

SECTION CONCRETE ANCHORING. Display hidden notes to specifier. (Don't know how? Click Here)

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

POWER-Skru Large Diameter Concrete Screw

BITS, NUTSETTERS, ADAPTERS

ANCHORS SLEEVE ANCHORS BOLT DIAMETER

Elco Construction Products 1301 Kerr Drive Decorah, IA fax:

FASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S. Which FERO Tie Systems Require Fasteners?

FOCUSING ON FASTENERS

Fasteners Engineered for Cutting Edge Performance

BUILT BY AMERICA. CONNECTED WORLDWIDE.

Peco Fasteners 3/8 Internal Plug Drop In 50 Per Jar 3/8-16 SMART DROP IN ANCHOR ZINC

Letter of Transmittal/Submittal

Screw selecting guide for Norex & Noroc panels installation (metal screw)

PRICE BOOK NO. 204S ORDERING INFORMATION

Dimensions Mechanical and Performance Requirements. Drop-In Anchors Hollow Wall, Steel Regular Style Drive Style...

YOUR ONE SOURCE FOR CONCRETE FASTENERS PRODUCT CATALOG. p f East 40th Street Cleveland, Ohio

Fasteners & Accessories For Commercial Construction

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

Hang-TITE Rod Hanger Screws

ZXL MB Advantage Catalog. A Division of The Hillman Group

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

CSS Central Mount System

GCN150 Gas-Actuated Concrete Nailer

Multi-Set II Drop-In Anchors

FASTENERS BUILDING DEPARTMENT

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

UNA-CLAD Metal Roof Systems

Fasteners & Accessories For Commercial Construction

BUILDING FASTENERS METAL TO WOOD FASTENERS

MX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

ALLIGATOR All-Purpose Anchors

ROOFSAFE ANCHOR & CABLE

GLOSSARY OF TERMS SECTION 8

Holemaking Products & Accessories

International Catalogue. Flat Roof Innovative fastening systems and application expertise

ESR-3042* Reissued August 1, 2012 This report is subject to renewal September 1, 2014.

PRODUCT INFORMATION. ASTM B633,SC1, Type III (Fe/Zn 5) Rod/Anchor Diameter

Coatings ASTM B117 SST Salt Spray Test Kesternick Phosphate Zinc E-Coat Dip Spin Coatings

Holemaking Products & Accessories

The Quick, Economical Method to Secure Hurricane Protection

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

ICC-ES Evaluation Report

MODERN PERGOLA INSTALLATION GUIDE. When only the best will do.

Contents. Grade 2, 5, 8 Hex Bolts 4. Heavy Hex Head Structural Bolts 6. A325 and A490 Tension Control Bolts (TC) 13. Nuts 22.

Grade 5 dual-hardened concrete/masonry screw anchoring system

Notes B

Metal Roof Installation Manual. Chapter 14: Fasteners

The All American Anchor is a positive drive positive setting anchor for use in all masonry materials / / /8 7 1/ /16

CertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS. Fence Installation Guide 3', 4' & 6' High

Pergola Installation Guide. When only the best will do.

Thermoplastic Mechanically Fastened Roofing Systems Induction Welding (RhinoBond / Isoweld) Attachment Method. Attachment I

FASTENERS ANCHORS - ADHESIVE. AC100E Professional Kits. Fasteners - Adhesive Anchoring-Concrete & Masonry

TAPTITE 2000 Fasteners

Hollo Set Drop-In Anchors

SECTION SHEET METAL FLASHING AND TRIM

Umbrella Inserts and Stubby Screens

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT

ESR-1271* Reissued September 1, 2013 This report is subject to renewal July 1, 2015.

SB-WM-ART1-M-BL. Weatherproof Universal Single-Arm Articulating Mount for Medium Displays INSTALLATION MANUAL

Powder Actuated Fastening INTRODUCTION

PULL TESTERS FOR FASTENER MEMBRANE FOAM TESTING

Flat Roof Fastening Systems for Sika Roofing

7141 & NATIONAL POLE VAULT STANDARDS SPECIFICATIONS

FASTENERS ANCHORS - ADHESIVE. AC100E Professional Kits. Fasteners - Adhesive Anchoring-Concrete & Masonry

TREX POST MOUNT DECKING AND CONCRETE

Evaluation of In-Pavement Light Fixture Designs and Performance

Complete line of Holemaking Products and Accessories

Buyers Guide. Pg. 74 Bronze Screws High Speed Drill Bits Pg. 106 Packaged Fasteners Pg. 108

INDEX PAGE RELEASE SECTION NUMBER DATE

PV MOUNTING SYSTEM INSTALLATION MANUAL

Flooring Nails 6-D Flooring Nails $3.40 / 1# 6-D Flooring Nails $14.50 / 5# 8-D Flooring Nails $3.40 / 1# 8-D Flooring Nails $14.

Powder Actuated Fasteners - Drive Pins

10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

C O N S T R U C T I O N F A S T E N E R S S T E E L POWDER ACTUATED CARBIDE DRILL BITS

SECTION 3. BOLTS. bolt is a standard AN-type or a special-purpose bolt, and sometimes include the manufacturer.

Load Tables, Technical Data and Installation Instructions

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

American Safe Room. Explosion Resistant Blast Hatch with Integrated Riser

Transcription:

Low Slope Fastening Solutions Guide Featuring Products & Systems

Table of Contents Section Page General Information Dekfast Identification Convention...2 Fasteners #12 Phillips Head...3 #12 Hex Head...4 #14 Phillips Head...5 #15 Phillips Head...6-7 Stress Plates Insulation Plates... 8-9 Membrane Plates...10-11 Section Page Rooftop Productivity Tools & Systems isofast Insulation Attachment...25 isofast Membrane Attachment...26 isoweld Induction Welding System...27 TPR-L Peel Rivet System...28 Stealth Pre-Assembly Tool...29-30 Reference Approved FM Fastening Patterns...31 Fastener...32 Specialty Fastening #12 Purlin...12 Insulation Panel Fastener...13 #14 Stainless...14 isotak...15 Deklite...16-17 Dekspike...18-19 ZAC Anchors...20 Zinc Nailins...21 Base Ply/Twin Loc-Nail Fasteners...22 Termination and Batten Bars... 23-24 1

Difference-making with Dekfast SFS intec has delivered fastening solutions for over fifty years to worldwide markets. The Dekfast brand is universally understood as the premier choice by specifiers and contractors for commercial low slope (flat roof) applications. Fastening Solutions Dekfast, an innovative and proven solution, is designed, manufactured and tested to achieve compliance with Factory Mutual (FM) 4470. Having a wide variety of materials, thread styles, point geometries, finishes and installation applications, Dekfast is a preferred choice for insulation and membrane attachment in wood, steel and concrete decks. Productivity Solutions SFS intec offers stand-up roofing tools to increase productivity and provide ergonomic benefits to roofing contractors. Having used SFS intec tools, contractors have reported significant rooftop productivity gains for insulation and membrane attachment in some cases productivity is "3x" faster. isofast and isoweld are unmatched in the industry and provide contractors with the edge required to get on and off of the roof more quickly. Job-Site Solutions SFS intec provides rooftop consultation, training and start-up support at no cost to the market. Our rooftop training programs are geared towards creating customer confidence and competence with all of the Dekfast brand offerings as well as our productivity tools. Job site solutions include: pull tests project start-up rooftop crew training Office-Based Solutions Supporting the Dekfast brand is our highly differentiated esolutions service offering. esolutions is a web-based application which streamlines customer order placement, tracking, invoicing, etc. esolutions empowers customers to be in control of their material requirements. Using esolutions will lead to improved order accuracy and reduced supply chain costs. 2

SFS intec "Intelligent Product Code" Dekfast Identification Convention #12 Dekfast, 3-3/4 Length, #3 Phillips Drive, E-Coat Black, Bulk/Pail DF - #12x3-3/4 - PH3 - E0999 - B Product Type Dimensions Head/Drive Coating Type & Color Code Packaging 2-3/8 Galvalume Steel Round, Barbed Plate (6 Barbs). Bulk/Pail PLT - R - 2-3/8-6B - B Product Type Shape Outside Dimension Barbs Packaging #14 Insulation Panel Fastener, 4 Length, Pancake Head, #3 Square Drive, E-Coat Black, Bulk/Pail IPF - #14x4 - PC - SQ3 - E0999 - B Product Type Dimensions Head Drive Coating Type & Color Code Packaging Product Type BB-R BP DF DL IPF PLT PUR SPK TB-AP TB-DB TB-F TB-FBB TB-LB TB-RSL TB-R TB-SL TLN TPR ZA ZNI Plates Coiled Batten Bar Base Ply Dekfast Deklite Insulated Panel Fastener Plate Purlin Spike Term Bar - All purpose Term Bar - Drain Bar Term Bar - Flat Flat Batten Bar Term Bar - Lip and Ball Term Bar - Ribbed Single Lip Term Bar - Ribbed Term Bar - Single Lip Twin Loc-Nail Peel Rivet ZAC Anchor Zinc Nail in PLT Plate Designation FL-P isoweld DL Deklite Plate G3 3" Round Galvalume (pre-assembled) H Hex HR Hex Recess O Oblong P Plastic R Round S Square xb Barbed & # of barbs Material Type S4 Stainless 400 series Head Type/Drive HWx/x PHx/x CHWx/x PC SQx/x Hex Washer Head Phillips Cupped Hex Washer Head Pancake Head Square Drive Washer N Neoprene Seal Washer Coating E0999 E-Coat Black Packaging B BL C CTN TUBE Bulk in cartons or pails Belted 100/bag or box Carton Tube 3

Fasteners #12 Phillips Head #3 Phillips drive, 13 tpi, drill point For insulation attachment to wood and steel roof decks Available with #3 Phillips drive. Drill point design prevents fastener walking. 13 threads per inch provides higher pull-out values. Drill point cuts through gravel and BUR. e-coat Application #12 Dekfast Fasteners Available pre-assembled and loose for insulation attachment to steel and wood. Materials: Steel thickness from 22 ga (.028 in.) through 18 ga (.045 in.): Min penetration: 3/4" Wood 2x (1-1/2" thick): Min penetration: 1" Plywood: Min thickness: 3/4" FR treated; min through penetration: 1/4" Dekfast 3" round metal plates and 2-7/8" hex metal plates Dekfast 3" round plastic Dekflat plates Head Types: #3 Phillips Head Height: Max.118" Head Dia: Max.448" Thread Major Dia:.222" Shank Dia:.167" Strength (lbs ult.): Tensile: 2410 Torsional: 76 in-lbs min Shear: 1815 Pull-out: (lbs avg.): Steel 22 ga: 513 Steel 20 ga: 695 Steel 18 ga: 787 2x dimensional lumber (1" penetration): 462 3/4" FR Plywood (through penetration): 575 Notes Dimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull-out (pounds ultimate) strength values may vary from tabulated loads depending upon the uniqueness of the application. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Fastener *Thread Material No. Carton Carton Skid Length Length Phillips Head North American Code Steel Wood Concrete Wt. (lbs) Qty. Qty. 1-5/8" Full 785683 DF-#12x1-5/8-PH3-E0999-B Up to 7/8" Up to 5/8" N/A 13 1,000 60,000 2-1/4" Full 785698 DF-#12x2-1/4-PH3-E0999-B 5/8" to 1-1/2" Up to 1-1/4" N/A 17 1,000 60,000 2-7/8" Full 785717 DF-#12x2-7/8-PH3-E0999-B 5/8" to 2-1/8" Up to 1-1/8" N/A 21 1,000 60,000 3-1/4" 3" 785735 DF-#12x3-1/4-PH3-E0999-B 1/2" to 2-1/2" 1/2" to 2-1/4" N/A 23 1,000 60,000 3-3/4" 3" 785761 DF-#12x3-3/4-PH3-E0999-B 1" to 3" 1" to 2-3/4" N/A 26 1,000 60,000 4-1/2" 4" 785781 DF-#12x4-1/2-PH3-E0999-B 3/4" to 3-3/4" 3/4" to 3-1/2" N/A 31 1,000 40,000 5" 4" 785797 DF-#12x5-PH3-E0999-B 1-1/4" to 4-1/2" 1-1/4" to 4" N/A 34 1,000 40,000 6" 4" 785818 DF-#12x6-PH3-E0999-B 2-1/4" to 5-1/4" 2-1/4" to 5" N/A 41 1,000 40,000 7" 4" 785835 DF-#12x7-PH3-E0999-B 3-1/4" to 6-1/4" 3-1/4" to 6" N/A 24 500 30,000 8" 4" 785851 DF-#12x8-PH3-E0999-B 4-1/4" to 7-1/4" 4-1/4" to 7" N/A 28 500 30,000 * Note - Thread length measured from tip of the drill point to end of threads. Approvals 12-1017.07 Tools: 2000 2500 rpm screw guns with hardened #3 Phillips bit. #12 Dekfast fasteners can be pre-assembled with metal or plastic insulation plates. The standard carton package includes one #3 Phillips bit. Options Insulation Plates Assemblies State of Florida: FL20311 Belted Systems Tools 4

Fasteners #12 Hex Head 1/4" hex drive, 13 tpi, drill point For insulation attachment to wood and steel roof decks Available with 1/4" hex head. Drill point design prevents fastener walking. 13 threads per inch provides higher pull-out values. Application #12 Dekfast Fasteners Available pre-assembled and loose for insulation attachment to steel and wood. Materials: Steel thickness from 22 ga (.028 in.) through 18 ga (.045 in.): Min penetration: 3/4" Wood 2x (1-1/2" thick): Min penetration: 1" Plywood: Min thickness: 3/4" FR treated; min through penetration: 1/4" Dekfast 2-7/8" hex plates Dekfast 3" round plastic Dekflat plates Drill point cuts through gravel and BUR. e-coat Head Types: 1/4" Hex Head Head Height: Max.118" Head Dia: Max.448" Thread Major Dia:.222" Shank Dia:.167" Strength (lbs ult.): Tensile: 2410 Torsional: 76 in-lbs min Shear: 1815 Pull-out: (lbs avg.): Steel 22 ga: 513 Steel 20 ga: 695 Steel 18 ga: 787 2x dimensional lumber (1" penetration): 462 3/4" FR plywood (through penetration): 575 Notes Dimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull-out (pounds ultimate) strength values may vary from tabulated loads depending upon the uniqueness of the application. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Fastener *Thread Material No. Carton Carton Skid Length Length Hex Head North American Code Steel Wood Concrete Wt. (lbs) Qty. Qty. 1-5/8" Full 790081 DF-#12x1-5/8-HW1/4-E0999-B Up to 7/8" Up to 5/8" N/A 14 1,000 60,000 2-1/4" Full 790087 DF-#12x2-1/4-HW1/4-E0999-B 5/8" to 1-1/2" Up to 1-1/4" N/A 18 1,000 60,000 2-7/8" Full 790090 DF-#12x2-7/8-HW1/4-E0999-B 5/8" to 2-1/8" Up to 1-1/8" N/A 23 1,000 60,000 3-1/4" 3" 790093 DF-#12x3-1/4-HW1/4-E0999-B 1/2" to 2-1/2" 1/2" to 2-1/4" N/A 26 1,000 60,000 3-3/4" 3" 790099 DF-#12x3-3/4-HW1/4-E0999-B 1" to 3" 1" to 2-3/4" N/A 29 1,000 48,000 4-1/2" 4" 790102 DF-#12x4-1/2-HW1/4-E0999-B 3/4" to 3-3/4" 3/4" to 3-1/2" N/A 34 1,000 40,000 5" 4" 790105 DF-#12x5-HW1/4-E0999-B 1-1/4" to 4-1/2" 1-1/4" to 4" N/A 37 1,000 40,000 6" 4" 790108 DF-#12x6-HW1/4-E0999-B 2-1/4" to 5-1/4" 2-1/4" to 5" N/A 44 1,000 40,000 7" 4" 790115 DF-#12x7-HW1/4-E0999-B 3-1/4" to 6-1/4" 3-1/4" to 6" N/A 25 500 30,000 8" 4" 790118 DF-#12x8-HW1/4-E0999-B 4-1/4" to 7-1/4" 4-1/4" to 7" N/A 28 500 30,000 * Note - Thread length measured from tip of the drill point to end of threads. Approvals State of Florida: FL20311 12-1017.07 Tools: 2000 2500 rpm screw guns with 1/4" hex head drive bits. #12 hex head Dekfast fasteners are available pre-assembled with metal insulation plates. The standard carton package includes one #1/4" Hex socket for HWH Options Insulation Plates Assemblies Tools Coatings 5

Fasteners #14 #3 Phillips drive, 10 tpi, drill point For insulation and membrane attachment to wood, steel, and structural concrete roof decks Can be pre-assembled to plastic Dekflat plate for insulation attachment and to seam plates for roof cover attachment. 10 threads per inch for ease of installation in concrete roof decks. Low profile truss head can be used for clip attachment in applications where head height is important. Application #14 Dekfast Fasteners Insulation board to roof deck Materials: Steel thickness from 22 ga (.028 in.) through 18 ga (.045 in.): Min penetration: 3/4" Plywood: Min thickness: 3/4" FR treated; min through penetration: 1/4" Wood 2x (1-1/2" thick): Min penetration: 1" Structural concrete: Min penetration: 1" Dekfast 2-7/8" hex plates Dekfast 3" round plastic Dekflat plates Other attachment elements approved by the roofing system manufacturer for use with its products Notes Dimensions are nominal inches unless noted. Steel roof decks include all FM-approved 18-20-22 ga. FM-approved wood decks include 3/4" FR plywood and 2x dimensional lumber. Structural concrete to be predrilled with standard 3/16" carbide bit to minimum 1/2" deeper than fastener penetration. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Fastener *Thread Material No. Carton Carton Skid Length Length Phillips Head #14-10 North American Code Steel Wood Concrete Wt. (lbs) Qty. Qty. 1-1/4" Full 1202602 DF-#14x1-1/4-PH3-E0999-B Up to 1/2" Up to 1/4" Up to 1/4" 12 1,000 60,000 2" Full 1203249 DF-#14x2-PH3-E0999-B Up to 1-1/4" Up to 1-1/4" Up to 1" 19 1,000 60,000 3" Full 1203528 DF-#14x3-PH3-E0999-B Up to 2-1/4" Up to 2" Up to 2" 24 1,000 60,000 4" Full 1203578 DF-#14x4-PH3-E0999-B 1-1/4" to 3-1/4" 1-1/4" to 3" 2" to 3" 30 1,000 60,000 5" 4' 1203605 DF-#14x5-PH3-E0999-B 1-1/4" to 4-1/4" 1-1/4" to 4" 3" to 4" 45 1,000 40,000 6" 4" 1203632 DF-#14x6-PH3-E0999-B 2-1/4" to 5-1/4" 2-1/4" to 5" 4" to 5" 46 1,000 40,000 7" 4" 1203659 DF-#14x7-PH3-E0999-B 3-1/4" to 6-1/4" 3-1/4" to 6" 5" to 6" 28 500 30,000 8" 4" 1203810 DF-#14x8-PH3-E0999-B 4-1/4" to 7-1/4" 4-1/4" to 7" 6" to 7" 31 500 30,000 9" 4" 1204081 DF-#14x9-PH3-E0999-B 5-1/4" to 8-1/4" 5-1/4" to 8" 7" to 8" 34 500 20,000 10" 4" 1202260 DF-#14x10-PH3-E0999-B 6-1/4" to 9-1/4" 6-1/4" to 9" 8" to 9" 38 500 20,000 11" 4" 1202597 DF-#14x11-PH3-E0999-B 7-1/4" to 10-1/4" 7-1/4" to 10" 9" to 10" 41 500 20,000 12" 4" 1202600 DF-#14x12-PH3-E0999-B 8-1/4" to 11-1/4" 8-1/4" to 11" 10" to 11" 45 500 20,000 * Note - Thread length measured from tip of the drill point to end of threads. Approvals 12-1017.07 Tools: 2000 2500 rpm screw guns and #3 hardened Phillips bit. For structural concrete, 3/16" carbide bit and 1500 rpm max screw guns, or hammerdrills in the hammer mode. The standard carton package includes one #3 Phillips bit. Options Insulation Plates Membrane Plates State of Florida: FL20311 Assemblies #3 Phillips recess provides for ultimate bit engagement. The Dekfast reduced drill point provides for ultimate pull-out values by producing a minimum opening. Thread engagement is superior as compared to standard drill points. e-coat Head: #3 Phillips Head Height:.118" max Head Dia:.448" max Thread Major Dia:.238" Shank Dia:.180" Strength (lbs ult.): Tensile: 3600 Torsional: 110 in-lbs min Shear: 2630 Pull-out: (lbs avg.): 22 ga: 540 20 ga: 630 18 ga: 900 4000 psi concrete (1" penetration): 850 3/4" plywood (through penetration): 590 2x dimensional lumber (1" penetration): 605 6

Fasteners #15 #3 Phillips drive, 13 tpi, drill point For insulation and membrane attachment to wood, steel, and structural concrete roof decks Can be pre-assembled to Dekfast steel membrane plates for roof cover attachment and 3" round Dekflat for insulation attachment. Application #15 Dekfast Phillips Head Insulation board to roof deck Materials: Steel thickness from 26 ga (.019 in.) through 18 ga (.045 in.): Min penetration: 3/4" Plywood: Min thickness 3/4" FR treated; min through penetration: 1/4" Wood 2x (1-1/2" thick): Min penetration: 1" Structural concrete: Min penetration: 1" Dekfast 2-7/8" hex plates Dekfast 3" round plastic Dekflat plates 3" round metal plates Batten Bar Steel membrane plates Other attachment elements approved by the roofing system manufacturer for use with their products Above average pull-out values in 24, 26 gauge metal panels. e-coat Head: #3 Phillips Head Height:.130" max Head Dia:.448" max Thread Major Dia:.263" Shank Dia:.204" Threads per Inch: 13 Strength (lbs ult.): Tensile: 4350 Torsional: 130 in-lbs min Shear: 3700 Pull-out: (lbs avg.): 22 ga: 706 20 ga: 898 18 ga: 1140 3/4" plywood (through penetration): 703 2x lumber (1-1/2" penetration): 692 Concrete 4000 psi (1" penetration): 728 Non FM Approved Decks: 26 ga: 301 24 ga: 453 Notes Dimensions are nominal inches unless noted. Steel roof decks include all FM-approved 18-20-22 ga. FM-approved wood decks include 3/4" FR plywood and 2x dimensional lumber. Structural concrete to be predrilled with standard 7/32" carbide bit to minimum 1/2" deeper than fastener penetration. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Fastener *Thread Carton Carton Skid Length Length Material No. North American Code Steel Wood Concrete Wt. (lbs) Qty. Qty. 1-1/4" Full 789566 DF-#15x1-1/4-PH3-E0999-B Up to 1/4" Up to 1/4" Up to 1/4" 13 1,000 60,000 2" 1.75" 1204935 DF-#15x2-PH3-E0999-B Up to 1-1/4" Up to 1" Up to 1" 24 1,000 60,000 3" 2.75" 789609 DF-#15x3-PH3-E0999-B Up to 2-1/4" Up to 2" 1" to 2" 30 1,000 60,000 4" 3.75" 789635 DF-#15x4-PH3-E0999-B 1-1/4" to 3-1/4" 1-1/4" to 3" 2" to 3" 42 1,000 60,000 5" 4" 789664 DF-#15x5-PH3-E0999-B 1-1/4" to 4-1/4" 1-1/4" to 4" 3" to 4" 51 1,000 40,000 6" 4" 789692 DF-#15x6-PH3-E0999-B 2-1/4" to 5-1/4" 2-1/4" to 5" 4" to 5" 30 500 30,000 7" 4" 1230686 DF-#15x7-PH3-E0999-B 3-1/4" to 6-1/4" 3-1/4" to 6" 5" to 6" 35 500 30,000 8" 4" 789740 DF-#15x8-PH3-E0999-B 4-1/4" to 7-1/4" 4-1/4" to 7" 6" to 7" 40 500 30,000 9 4" 1297437 DF-#15x9-PH3-E0999-B 5-1/4" to 8-1/4" 5-1/4" to 8" 7" to 8" 45 500 20,000 10" 4" 789767 DF-#15x10-PH3-E0999-B 6-1/4" to 9-1/4" 6-1/4" to 9" 8" to 9" 49 500 20,000 12" 4" 789791 DF-#15x12-PH3-E0999-B 8-1/4" to 11-1/4" 8-1/4" to 11" 10" to 11" 29 250 10,000 14" 4" 789807 DF-#15x14-PH3-E0999-B 10-1/4" to 13-1/4" 10-1/4" to 13" 12" to 13" 34 250 6,000 16" 4" 789822 DF-#15x16-PH3-E0999-B 12-1/4" to 15-1/4" 12-1/4" to 15" 14" to 15" 38 250 6,000 18" 4" 789830 DF-#15x18-PH3-E0999-B 14-1/4" to 17-1/4" 14-1/4" to 17" 16" to 17" 42 250 6,000 20" 4" 789835 DF-#15x20-PH3-E0999-B 16-1/4" to 19-1/4" 16-1/4" to 19" 18" to 19" 47 250 6,000 22" 4" 1204091 DF-#15x22-PH3-E0999-B 18-1/4" to 21-1/4" 18-1/4" to 21" 20" to 21" 52 250 6,000 24" 4" 789845 DF-#15x24-PH3-E0999-B 20-1/4" to 23-1/4" 20-1/4" to 23" 22" to 23" 56 250 6,000 26" 4" 789850 DF-#15x26-PH3-E0999-B 22-1/4" to 25-1/4" 22-1/4" to 25" 24" to 25" 61 250 6,000 28 4" 1204092 DF-#15x28-PH3-E0999-B 24-1/4" to 27-1/4" 24-1/4" to 27" 26" to 27" 54 200 4,800 * Note - Thread length measured from tip of the drill point to end of threads. Continued on following page 7

Fasteners #15 #3 Phillips drive, 13 tpi, drill point For insulation and membrane attachment to wood, steel, and structural concrete roof decks Approvals State of Florida: FL20311 12-1017.07 Tools: 2000 2500 rpm screw guns and #3 hardened Phillips bit. For structural concrete, 7/32" carbide bit and 1500 rpm screw gun or hammer drill in hammer mode. The standard carton package includes one #3 Phillips bit. Options Insulation Plates Membrane Plates Assemblies Tools isoweld 8

Stress Plates Insulation Plates 2-7/8" hex plate, 3" round For insulation using Dekfast #12, #12 Hex, #14, #15, Dekspike, Deklite, and T.P.R. Flat bottom provides for use on rigid board surfaces. Metal plates are stacked for ease of use. Application Galvalume Steel Hex Insulation Plate #12 Dekfast #14 Dekfast #15 Dekfast 1/4" Dekfast Spike TPR OD: 2-7/8" Hex ID:.270" Thickness:.019" Finish: AZ50 Galvalume Galvalume Steel 3" Round Insulation Plate #12 Dekfast #14 Dekfast #15 Dekfast TPR 1/4" Dekfast Spike OD: 3" Round ID:.260" Thickness:.019" Finish: AZ50 Galvalume Available pre-assembled to Dekfast #12 Phillips Dekflat 3" Round Plastic Lock Plate Flat bottom is ideal for use with rigid board surfaces as well as standard insulation boards. #12 Dekfast #14 Dekfast #15 Dekfast OD: 3" Round ID:.260" Material: Polypropylene Can be pre-assembled to Dekfast #14 or #12 Phillips fasteners isoweld plates #15 Dekfast Contact SFS for special use applications with: #12 Dekfast #14 Dekfast BS 6.1mm Weld interface surface TPO membrane to TPO plate Weld interface surface PVC/ KEE membrane to PVC plate TPO PVC/KEE OD: 3.12" Round ID:.260" Material: G90 Steel with proprietary TPO adhesive coating Color: Yellow Coating back of plate: polyester gray OD: 3.12" Round ID:.260" Material: G90 Steel with proprietary PVC adhesive coating Color: Purple Coating back of plate: polyester gray Notes Dimensions are nominal inches unless noted. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Continued on following page 9

Stress Plates Insulation Plates 2-7/8" hex plate, 3" round For insulation using Dekfast #12, #12 Hex, #14, #15, Dekspike, Deklite, and T.P.R. Item Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty. Galvalume Steel Hex Insulation Plate 730612 PLT-H-2-7/8-B 38 1,000 40,000 Galvalume Steel 3" Round Insulation Plate 739814 PLT-R-3-B 41 1,000 40,000 Dekflat 3" Round Plastic Lock Plate 792622 PLT-P-R-3-B 22 1,000 36,000 isoweld Plate - PVC 1486156 FI-P-6,8-PVC-PC 34 500 18,000 isoweld Plate - TPO 1486155 FI-P-6,8-TPO-PC 34 500 18,000 Approvals State of Florida: FL20311 12-1017.07 Use in applications approved by the roofing system manufacturer. Options #12 #14 #15 Assemblies Dekspike T.P.R. Peel Rivet 10

Stress Plates Membrane Plates 2-3/8" round, 2" round For membrane using #14, #15, K-fast, Dekspike, and T.P.R. Engineered barb design creates maximum wind uplift rating. Application Galvalume Steel Round 2" 22-Ga Barbed Plate #14 Dekfast #15 Dekfast 1/4" Dekfast Spike TPR SFS intec plates are stacked for ease of fastening pattern. OD: 2" ID:.265/.270" Thickness:.032" Finish: AZ55 Galvalume Non-Barbed Galvalume 2" Round Membrane Plate #12 Dekfast #14 Dekfast OD: 2" Round ID:.255" Thickness:.032" Finish: AZ55 Galvalume Galvalume Steel Round 2-3/8" 20-Ga Barbed Plate #14 Dekfast #15 Dekfast 1/4" Dekfast Spike TPR OD: 2-3/8" ID:.260/.262" Thickness:.038" Finish: AZ50 Galvalume Galvalume Steel Oval 1-1/2" x 2-3/4" 18-Ga Barbed Plate Use for PVC membrane with: #14 Dekfast #15 Dekfast #12 Purlin Lenth: 2.750" Width: 1.500" ID:.250" Thickness:.048" Finish: AZ50 Galvalume Notes Dimensions are nominal inches unless noted. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Continued on following page 11

Stress Plates Membrane Plates 2-3/8" round, 2" round For membrane using #14, #15, K-fast, Dekspike, and T.P.R. Item Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty. Galvalume Steel Round 2", 22-Ga Barbed Plate 298312 PLT-R-2-4B-B 29 1000/pail 40,000 Non-Barbed Galvalume 2" Round Membrane Plate 727658 PLT-R-2-B 34 1000/pail 50,000 Galvalume Steel Round 2-3/8", 20-Ga Barbed Plate 982326 PLT-R-2-3/8-6B-B 36 1000/pail 24,000 Galvalume Steel Oval 1-1/2" x 2-3/4", 18-Ga Barbed Plate 1274909 PLT-02-3/4-12B-B 12 500/pail 20,000 Approvals 12-1017.07 Use in applications approved by the roofing system manufacturer. Options State of Florida: FL20311 #14 #15 Assemblies Belted Systems T.P.R. Peel Rivet 12

Specialty Fastening #12 Purlin Fastener #3 square drive, drill point For retro-fit roofing systems where heavy gauge purlin material must be penetrated Shank diameter is smaller than that of the drill point and the outside thread diameter, allowing thick metal to be drilled and cleared of chips before threads tap into metal. Application Dekfast #12 Purlin Fasteners Up to 1/4" purlin steel Materials: Steel thickness: 18 ga (.045" nominal) through 1/4" (.250") 24 threads per inch allow for easier driving of the fastener and greater pull-out values. e-coat Notes Dimensions are nominal inches unless noted. * Denotes tensile failure of fastener (fastener failed in tensile before pulling out of tabulated substrate). Fasteners are designed for the attachment of roofing materials to purlins. Designated holding values depend on the quality of materials to which the fastener is being anchored. Pull-out tests need to be conducted to verify that the substrate provides adequate pull-out values. Fastener *Thread Pilot Composite Carton Carton Skid Length Length Length Material No. North American Code Thickness Wt. (lbs) Qty. Qty. 12 x 3-3/4" 3.375" 0.750" 1202224 PUR-#12x3-3/4-PC-SQ3-E0999-B Up to 2-3/4" 33 1000 60,000 12 x 4-3/4" 3.375" 0.750" 1202226 PUR-#12x4-3/4-PC-SQ3-E0999-B 1-1/4" to 3-3/4" 41 1000 40,000 12 x 5-3/4" 3.375" 0.750" 1202228 PUR-#12x5-3/4-PC-SQ3-E0999-B 2-1/4" to 4-3/4" 48 1000 40,000 12 x 6-3/4" 3.375" 0.750" 1202230 PUR-#12x6-3/4-PC-SQ3-E0999-B 3-1/4" to 5 3/4" 28 500 30,000 * Note - Thread length measured from tip of the drill point to end of threads. Tools: 1800 2500 rpm screw gun equipped with depth-sensing nosepiece. The standard carton package includes one #3 square bit. Thread Length Pilot Length Head: #3 square, pancake head Head Height:.110" Head Dia:.445" Thread Major Dia:.207" Shank Dia:.179" nom Strength (lbs ult.): Tensile: 2300 Torsional: 100 in-lbs min Pull-out: (lbs avg.): 18 ga (.045): 375 16 ga (.060): 599 14 ga (.075): 869 12 ga (.104): 1477 3/16" (.188): 2300* 1/4" (.250): 2300* Options isoweld 13

Specialty Fastening Insulation Panel Fastener #14 #3 square drive, drill point For use in vented and/or composite nailboard applications Flat profile head for flush engagement to the nailboard. No plates necessary. Application Insulation Panel Fasteners #14 #3 square drive, drill point Materials: Dimensional wood 2x (1-1/2" thick): Min penetration: 1" Steel thickness: 22-20-18 ga: Min penetration: 3/4" 5/8" oversized head reduces fastener patterns. e-coat Head: #3 square drive Head Dia:.645".620" Head Height:.078".072" Thread Major Dia:.245" Shank Dia:.190" Strength (lbs ult.): Tensile: 3500 Shear: 2700 Torque: 125 in-lbs Pull-out (1" penetration) (lbs avg.): Face Grain: 823 Edge Grain: 845 1-1/2" Penetration: Face Grain: 1344 Edge Grain: 1320 Grade E steel deck: 22 ga (.030): 498 Notes Dimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull-out (pounds ultimate) strength values may vary from tabulated loads depending upon specific wood density variation. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Fastener Length *Thread Length Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty. 2-5/8" 1.5" 1119456 IPF-#14x2-5/8-PC-SQ3-E0999-B 15 500 30,000 3" 1.5" 1119468 IPF-#14x3-PC-SQ3-E0999-B 16 500 30,000 3-1/2" 3" 1119481 IPF-#14x3-1/2-PC-SQ3-E0999-B 18 500 30,000 4" 3" 1119482 IPF-#14x4-PC-SQ3-E0999-B 21 500 30,000 4-1/2" 3" 1119484 IPF-#14x4-1/2-PC-SQ3-E0999-B 23 500 30,000 5" 3" 1119486 IPF-#14x5-PC-SQ3-E0999-B 25 500 30,000 5-1/2" 3" 1119494 IPF-#14x5-1/2-PC-SQ3-E0999-B 27 500 30,000 6" 3" 1119495 IPF-#14x6-PC-SQ3-E0999-B 29 500 30,000 6-1/2" 3" 1119497 IPF-#14x6-1/2-PC-SQ3-E0999-B 31 500 30,000 7" 3" 1119501 IPF-#14x7-PC-SQ3-E0999-B 33 500 30,000 7-1/2" 3" 1119505 IPF-#14x7-1/2-PC-SQ3-E0999-B 34 500 30,000 8" 3" 786137 IPF-#14x8-PC-SQ3-E0999-B 18 250 15,000 8-1/2" 3" 1119513 IPF-#14x8-1/2-PC-SQ3-E0999-B 20 250 15,000 9" 3" 1119516 IPF-#14x9-PC-SQ3-E0999-B 20 250 10,000 10" 3" 1119539 IPF-#14x10-PC-SQ3-E0999-B 23 250 10,000 * Note - Thread length measured from tip of the drill point to end of threads. Install fasteners with self-drill fastener installation tool or drill using caution to avoid fastener strip out. The standard carton package includes one #3 square drive bit. 14

Specialty Products #14 Stainless #14, 13 tpi, drill point For the attachment of insulation and membrane roof covers in a corrosive environment 400 series stainless steel is a magnetic heat-treatable stainless steel Application Dekfast #14 Stainless Steel Attachment of insulation and/or roof covers in mild to light industrial environments Materials: Steel thickness from 22 ga (.028 in.) through 18 ga (.045 in.): Min penetration: 3/4" Plywood: Min thickness: 3/4" FR treated: Min penetration: 1/4" Wood 2x: (1-1/2" thick): Min penetration 1" Stress plates Batten Bar Other attachment elements approved by the roofing system manufacturer for use with its products Steel roof decks include all FM approved 18-20-22 ga Notes Dimensions are nominal inches unless noted. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Fastener *Thread Carton Carton Skid Length Length Material No. North American Code Steel Wood Concrete Wt. (lbs) Qty. Qty. 1-1/2" Full 791371 DF-S4-#14x1-1/2-PH3-B Up to 3/4" Up to 1/2" Up to 1/2" 14 1,000 60,000 2" Full 791373 DF-S4-#14x2-PH3-B Up to 1-1/4" Up to 1" 1/2" to 1" 18 1,000 60,000 3" 2.875" 791376 DF-S4-#14x3-PH3-B 3/8" to 2-1/4" Up to 2" 1-1/2" to 2" 25 1,000 40,000 4" 3.875" 791379 DF-S4-#14x4-PH3-B 3/8" to 3-1/4" Up to 3" 2-1/2" to 3" 32 1,000 40,000 5" 3.875" 791381 DF-S4-#14x5-PH3-B 1-3/8" to 4-1/4" 1-3/8" to 4" 3-1/2" to 4" 39 1,000 40,000 6" 3.875" 791383 DF-S4-#14x6-PH3-B 2-3/8" to 5-1/4" 2-3/8" to 5" 4-1/2" to 5" 46 1,000 40,000 7" 3.875" 791385 DF-S4-#14x7-PH3-B 3-3/8" to 6-1/4" 3-3/8" to 6" 5-1/2" to 6" 27 500 30,000 8" 3.875" 791387 DF-S4-#14x8-PH3-B 4-3/8" to 7-1/4" 4-3/8" to 7" 6-1/2" to 7" 30 500 30,000 10" 3.875" 791389 DF-S4-#14x10-PH3-B 6-3/8" to 9-1/4" 6-3/8" to 9" 8-1/2" to 9" 39 250 20,000 12" 3.875" 1298264 DF-S4-#14x12-PH3-B 8-3/8" to 11-1/4" 8-3/8" to 11" 10-1/2" to 11" 48 250 20,000 * Note - Thread length measured from tip of the drill point to end of threads. Approvals State of Florida: FL20311 Type 410 self-drilling fasteners provide fair resistance to corrosion in mild to light industrial environments. Head: #3 Phillips Truss head Head Height:.118" max Head Dia:.440" max Thread Major Dia:.235" Shank Dia:.180" Pull-out: (lbs avg.): 24 ga: 325 22 ga: 470 20 ga: 635 18 ga: 815 Plywood (3/4" thick): 495 Tools: 2000 2500 rpm screw guns and #3 hardened Phillips bit. The standard carton package includes one #3 Phillips bit. Options Dekfast stainless fasteners must be used with the following plates or other attachment elements approved by the roofing systems manufacturer for use with their products: 3" round plastic plate (792622). Insulation Plates Membrane Plates 15

Specialty Fastening isotak Thermal break fastening system For attachment of membrane and insulation reducing thermal bridging Guards against fastener thermal bridging Ideal for low slope roof and cold storage construction Cost savings through energy conservation Applications isotak System Materials: #14 isotak fastener Polypropylene sleeve for insulation attachment The combination of sleeve and fastener length will determine the minimum and maximum build-up thickness the system can accommodate, with a maximum thickness up to 18" Lower cost alternative for attaching thick roof assemblies Factory Mutual approved Fastener Fastener Head: Countersunk head, drive T25 Fastener Head Dia: 0.358" Thread Major Dia: 0.240" Sleeve Material: Polypropylene, PP Plate Dia: 3" Round Shank Dia: 0.590 Pull-out (lbs. avg.): 22 ga: 573 20 ga: 660 18 ga: 1005 Notes Dimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull-out (pounds ultimate) strength values may vary from tabulated loads depending upon the uniqueness of the application. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Fastener Length Material No. Code Carton Wt. (lbs) Carton Qty. 2-3/8" 1185063 BS-6.1/52x60 9 500 4" 1185059 BS-6.1/91x100 14 500 6" 1193134 BS-6.1/141x150 21 500 7-7/8" 1193137 BS-6.1/192x200 28 500 Sleeve Length Material No. Code Carton Wt. (lbs) Carton Qty. 4-1/8" 1037836 R75x105 23 500 5-1/4" 1037838 R75x135 26 500 6-1/2" 1037839 R75x165 13 250 8-7/8" 1037842 R75x225 16 250 10" 1037843 R75x255 18 250 11-1/4" 1037844 R75x285 15 200 Approvals State of Florida: FL20311 For ease of installation, special drive shafts and driving tools are available. 16

Specialty Fastening Deklite Nylon reinforced fiberglass auger For lightweight roof decks: lt. wt. concrete, Tectum, and gypsum, for insulation and membrane attachment Deklite tapered root progressively compacts the material making the deck denser around the root, increasing pull-out values. Application Deklite Non-penetrating Nylon Fastener Materials: Lightweight insulating concrete, poured gypsum, gypsum plank, Tectum Min penetration: 1-1/2" Auger locks to plate upon installation. Tapered design also yields 70% more surface area leading to a greater holding power. Head OD: 1" Head Height: 1/8" Insert Size: 1/4" square drive Fixture Clearance Hole: 5/8" Fixture clearance holes are needed only when plywood or other rigid materials are fastened to a roof deck. Deklite Galvalume Steel 2" Round Seam Plate OD: 2" Thickness:.032" Finish: AZ55 Galvalume Deklite Galvalume Steel 3" Round Insulation Plate OD: 3" Thickness:.017" Finish: AZ55 Galvalume Notes Dimensions are nominal inches unless noted. Due to density differences in light weight insulating concretes, Tectum, and gypsum type roof decks, conducting field pull-out testing is recommended. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Continued on following page 17

Specialty Fastening Deklite Nylon reinforced fiberglass auger For lightweight roof decks: lt. wt. concrete, Tectum, and gypsum, for insulation and membrane attachment Length Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty. 2" 792776 DLx2-SQ1/4-B 14 500 31,500 2-1/2" 792778 DLx2-1/2-SQ1/4-B 15 500 22,500 3" 792780 DLx3-SQ1/4-B 17 500 22,500 3-1/2" 792782 DLx3-1/2-SQ1/4-B 18 500 22,500 4" 792784 DLx4-SQ1/4-B 19 500 13,500 4-1/2" 792786 DLx4-1/2-SQ1/4-B 21 500 13,500 5" 792788 DLx5-SQ1/4-B 22 500 9,000 5-1/2" 792790 DLx5-1/2-SQ1/4-B 23 500 9,000 6" 792792 DLx6-SQ1/4-B 25 500 9,000 6-1/2" 792794 DLx6-1/2-SQ1/4-B 26 500 9,000 7" 792796 DLx7-SQ1/4-B 14 250 6,750 7-1/2" 792798 DLx7-1/2-SQ1/4-B 15 250 6,750 8" 792800 DLx8-SQ1/4-B 16 250 6,750 8-1/2" 792802 DLx8-1/2-SQ1/4-B 17 250 6,750 9" 792804 DLx9-SQ1/4-B 17 250 4,500 9-1/2" 792806 DLx9-1/2-SQ1/4-B 17 250 4,500 10" 792807 DLx10-SQ1/4-B 18 250 4,500 11 792809 DLx11-SQ1/4-B 19 250 4,500 12 792810 DLx12-SQ1/4-B 21 250 4,500 13 792811 DLx13-SQ1/4-B 22 250 4,500 Deklite Stress Plates Length Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty. 2" Stress Plate 792743 PLT-DL-R-2-4B-B 18 500 4,500 3" Stress Plate 792745 PLT-DL-R-3-4B-B 18 500 4,500 Performance Base Material Pre-Drill Embedment Tension Load Tectum Deck 1-1/2 " 280 lbs Tectum Deck 2" 440 lbs Tectum Deck 2-1/2" 595 lbs 3" Insulrock 5/16" 2-1/2" 365 lbs Poured Gypsum 3/8" 2" 540 lbs Notes: Load capacities are based on testing conducted according to ASTM Standard E 488. Test data above represent average ultimate loads sustained in the materials indicated and should be used as guidelines only. Job site tests are recommended. Tectum is a registered trademark of Tectum, Inc. Approvals State of Florida: FL20311 *Deklite fasteners not included. 12-1017.07 Tools: Impact wrench or hammer drills in the hammer mode. The standard carton package includes one 1/4" square drive bit. 18

Specialty Fastening Dekspike 1/4" mushroom head For insulation and membrane attachment to structural concrete roof decks Compresses at 3 contact points to match the tolerance of the drilled hole. Applications Dekspike Structural Concrete Roofing Anchor Materials: Structural concrete: Min penetration: 1-1/4" (Min penetration for 1-1/4" length: 7/8") Composition thickness range of Dekspike 1-1/2" through 16": Anchor length less 1-1/4" (Min embedment: 1-1/4") Composition thickness range of Dekspike 1-1/4": 3/8" (Min embedment: 7/8") Min FM approved insulation board for concrete application: 1/2" Min FM approved penetration: 1-1/4" Shortest FM approved length for insulation attachment: 2" Batten Bar Steel insulation plates Steel membrane plates Can withstand dynamic loads induced by wind loading. e-coat Head: Mushroom Head Head Height:.120" max Head Dia:.500" max Shank Dia:.239" Strength (lbs ult.): Tensile (at 1-1/4" embedment): 1100 Pull-out: (lbs avg.): 4000 psi (1-1/4" penetration): 1550 Notes Dimensions are nominal inches unless noted. Tension strength (pull-out) based on 1-1/4" embedment depth and 2500 psi concrete. Pull-out strength is 1100 lbs ult. in 2500 psi concrete (FM J.I. No. 0Y0A8.AM) at 1-1/4" penetration depth. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Length Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty. 1-1/4" 792840 SPK-#14x1-1/4-E0999-B 11 500 60,000 1-1/2" 792841 SPK-#14x1-1/2-E0999-B 11 500 60,000 2" 792842 SPK-#14x2-E0999-B 16 500 60,000 2-1/2" 792843 SPK-#14x2-1/2-E0999-B 21 500 42,000 3" 792844 SPK-#14x3-E0999-B 22 500 18,000 3-1/2" 792845 SPK-#14x3-1/2-E0999-B 25 500 18,000 4" 792846 SPK-#14x4-E0999-B 31 500 18,000 4-1/2" 792847 SPK-#14x4-1/2-E0999-B 31 500 18,000 5" 792850 SPK-#14x5-E0999-B 35 500 18,000 5-1/2" 792853 SPK-#14x5-1/2-E0999-B 36 500 18,000 6" 792856 SPK-#14x6-E0999-B 20 250 21,000 7" 792860 SPK-#14x7-E0999-B 23 250 21,000 7-1/2" 792861 SPK-#14x7-1/2-E0999-B 26 250 21,000 8" 792864 SPK-#14x8-E0999-B 28 250 21,000 9" 792868 SPK-#14x9-E0999-B 30 250 9,000 10" 792870 SPK-#14x10-E0999-B 33 250 4,500 11" 792872 SPK-#14x11-E0999-B 14 100 8,000 12" 792874 SPK-#14x12-E0999-B 15 100 8,000 13" 792875 SPK-#14x13-E0999-B 16 100 5,000 14" 792878 SPK-#14x14-E0999-B 17 100 5,000 Continued on following page 19

Specialty Fastening Dekspike 1/4" mushroom head For insulation and membrane attachment to structural concrete roof decks Approvals 12-1017.07 Tools: ANSI 1/4" diameter (.268.260 dia) drill bit. Drill hole depth at least 1/2" beyond the anticipated embedment depth. Clean the hole and drive Dekspike flush against the plate or material being fastened. Options Insulation Plates State of Florida: FL20311 Membrane Plates Termination Product 20

Specialty Fastening ZAC Anchors 3/8" HWH termination fastener For fastening termination bar at wall terminations Term bar fastener that can be backed out. Threads into wood, masonry, concrete and metal. ZAC cap is zinc aluminum composition and will never red rust. Application ZAC Anchor Wood, masonry, concrete, and steel at roof wall terminations. Can be removed and re-engaged for roof repairs without damage to the roof system. e-coat coating on thread. Head: 3/8" AF ZAC HWH Long Life Dia: #14 (.248) Notes Dimensions are nominal and in inches unless noted. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Performance Load Capacities (2000 psi concrete) Pre-Drill 7/32" 7/32" 7/32" Embed. Depth 1" 1.25" 1.375" Tension Load (lbs) 620 810 905 Shear Load (lbs) 830 1130 1280 Notes: All load values listed are ultimate load capacities and are not allowable load capacities. These loads should be reduced by an appropriate safety factor of at least 4 to determine the allowable load. Dia and Length Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty. #14 x 1-3/8" HWH ZAC Anchor 792897 ZA-#14x1-3/8-HW3/8-N-E0999-C 25 1000 60,000 Notes: Load capacity is related to embedment depth. Select anchor length to provide needed embedment depth for the installed anchor. Tools: Carbide-tipped masonry drill bit sized slightly larger than nominal diameter to allow clearance. Options Termination Product 21

Specialty Fastening Zinc Nailins Termination fastener For fastening termination bar at wall terminations Long life coatings and composition prevent corrosion. Application Zinc Nailin Concrete, block, brick and stone Head: Mushroom Dia: 3/16" and 1/4" Body: Zamac 7 Notes Dimensions are nominal inches unless noted. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Performance Load Capacities (4000 psi concrete) Diameter 3/16" 1/4" 1/4" 1/4" 1/4" 1/4" Embed. Depth 3/4" 5/8" 7/8" 1-1/8" 1-3/8" 1-7/8" Tension Load (lbs) 500 600 820 960 1150 1300 Shear Load (lbs) 1000 1500 1500 1500 1500 1500 Notes: All load values listed are ultimate load capacities and are not allowable load capacities. These loads should be reduced by an appropriate safety factor of at least 4 to determine the allowable load. Dia and North Inner Carton Carton Skid Length Material No. American Code Nail Box Qty. Wt. (lbs) Qty. Qty. 3/16 x 7/8" 792879 ZNI-3/16x7/8-C Plated Steel 100 5 500 60,000 1/4 x 3/4" 792880 ZNI-1/4x3/4-C Plated Steel 100 8 500 60,000 1/4 x 1" 792881 ZNI-1/4x1-C Plated Steel 100 10 500 60,000 1/4 x 1-1/4" 792882 ZNI-1/4x1-1/4-C Plated Steel 100 12 500 60,000 1/4 x 1-1/2" 792884 ZNI-1/4x1-1/2-C Plated Steel 100 13 500 60,000 1/4 x 2" 792885 ZNI-1/4x2-C Plated Steel 100 16 500 60,000 Notes: Load capacity is related to embedment depth. Select anchor length to provide needed embedment depth for the installed anchor. The 1-1/4" length is popular for 1/8" composite thickness applications resulting in 1-1/8" embedment. Tools: Carbide-tipped masonry drill bit sized slightly larger than nominal diameter to allow clearance. A 3/16" nominal masonry drill bit is actually.198".206" dia. A 1/4" nominal size is actually.260".268" dia. Procedure: Position the fixture and drill a hole the same diameter as the zinc nail-in (3/16" or 1/4"). Insert the anchor and tap gently against the fixture to be fastened. Drive the nail flush to the anchor head to expand the anchor. Options Termination Product 22

Specialty Fastening Base Ply/Twin Loc-Nail Fasteners Base Sheet Attachment Base Sheet, Recovery Board and Insulation Attachment to Concrete, Wood Fiber and Poured Gypsum Non-threaded fastener Precision formed from coated steel to prevent corrosion Application FM90 and FM75 Base sheet attachment to higher density/lightweight Insulation Concrete Fastener anchors itself in its own hole. No pre-drilling required. Twin Loc-Nail Base sheet, recovery board and insulation to lightweight insulation concrete, structural wood fiber and poured Gypsum. Tube shape easily penetrates decking and existing membrane. First impact sets tube, second impact actuates staple. Should always be embedded into the structural roof deck to a depth of at least 1" Plate Dia.: 2.7" Leg Length FM-90: 1.7" FM-75: 1.2" Pull-out value dependent on substrate. On-site pull testing should be performed prior to roofing. Plate Dia.: 2.7" Tube Length: 1.4", 1.8", 2.8", 3.8" and 4.8" Pull-out value dependent on substrate. On-site pull testing should be performed prior to roofing. Notes Fastener density and spacing vary depending on applicable uplift requirements. Local codes, governing approval boadies, membrane manufacturers and individual roof deck manufacturers may have specific requirements that need to be addressed prior to beginning roofing project. Material No. Carton Product Base Ply Fast North American Code Carton Wt. (lbs) Qty. Dekfast/FM90-1.7" Assembled 501347 BP-2.7x1.7-B 40 1000 Dekfast/FM75-1.2" Assembled 501346 BP-2.7x1.2-B 36 1000 Twin Loc-Nail 1.4" 792822 TLN-2.7x1.4-B 27 500 Twin Loc-Nail 1.8" 792823 TLN-2.7x1.8-B 28 500 Twin Loc-Nail 2.8" 792824 TLN-2.7x2.8-B 34 500 Twin Loc-Nail 3.8" 792825 TLN-2.7x3.8-B 42 500 Twin Loc-Nail 4.8" 792826 TLN-2.7x4.8-B 27 250 Tools Material No. North American Code Carton Wt.(lbs) Carton Qty. Magnetic Drive 792819 TOOL-Magnetic Driver Tool 23 1 Magnetic Twin Lock Driver Tool 792821 TOOL-Magnetic Twin Loc Driver Tool 5 1 To ensure proper installation, use the Dekfast Magnetic Driver for FM-90 and FM-75 product. Use the Twin Loc Driver to install the Twin Loc-Nail. Consult Factory Mutual, Underwriters Lab or Miami-Dade requirements for recommended pattern in normal, exposed and hurricane areas. 23

Specialty Fastening Termination and Batten Bars.050",.075",.090",.100",.125", 6" OC For wall termination applications Manufactured from specially extruded aluminum without sharp edges. Application Ribbed Term Bar w/ Lip #14 Dekfast Fastener #15 Dekfast Fastener Zac Anchor Zinc Nailin Dekspike Reinforced strengthening ribs allow for use in high wind applications. Dimensions:.050" (edge) x.075" (ribs) x 1" wide x 10 long Holes:.260" x.380" slotted at 6" O.C. spacing Material: Extruded Aluminum Ribbed Term Bar #14 Dekfast Fastener #15 Dekfast Fastener Zac Anchor Zinc Nailin Dekspike Dimensions:.075 (edge) x.100" (ribs) x 1" wide x 10 long Holes:.260" x.380" slotted at 6" O.C. spacing Material: Extruded Aluminum Lip & Ball Term Bar #14 Dekfast Fastener #15 Dekfast Fastener Zac Anchor Zinc Nailin Dekspike Dimensions:.088" x 1" wide x 10' long Holes:.280" x.380" slotted at 6" O.C. spacing Material: Extruded Aluminum Gravel Stop/Drain Bar #14 Dekfast Fastener #15 Dekfast Fastener Zac Anchor Zinc Nailin Dekspike Dimensions:.110" x 3.50" wide x 10' long Drainage Holes:.300" x 1.62" slotted at 4" O.C. spacing Fastener Holes:.25" x.625" slotted at 6" O.C. spacing Material: Extruded Aluminum Notes Dimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull out (pounds ultimate) strength values may vary from tabulated loads depending upon the uniqueness of the application. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Continued on following page 24

Specialty Fastening Termination and Batten Bars.050,".075",.090,".100",.125," 6" OC For wall termination applications Material No. Carton Hole Termination Product Termination North American Code Wt. (lbs) Spacing Carton Qty. Skid Qty..050" All Purpose 791391 TB-AP-.05x1x120-6o.c.-TUBE 45 6" 500 feet (50-10 ft pcs) 10,000.075" Single Lip 791394 TB-SL-.075x1x120-6o.c.-TUBE 51 6" 500 feet (50-10 ft pcs) 10,000.075" Ribbed Single Lip 791395 TB-RSL-.075x1x120-6o.c.-TUBE 51 6" 500 feet (50-10 ft pcs) 10,000.100" Single Lip 791401 TB-SL-.1x1x120-6o.c.-TUBE 68 6" 500 feet (50-10 ft pcs) 10,000.125" Flat 791403 TB-F-.125x1x120-6o.c.-TUBE 78 6" 500 feet (50-10 ft pcs) 10,000.100" Ribbed Term Bar Flat 791404 TB-R-.1x1x120-6o.c.-TUBE 78 6" 500 feet (50-10 ft pcs) 10,000 Drain Bar/Gravel Stop 791410 TB-DB-.125X3.5x120-TUBE 42 6" 100 feet (10-10 ft pcs) 10,000.090" Lip and Ball 791411 TB-LB-0.09-TUBE 86 6" 500 feet (50-10 ft pcs) 10,000 Flat Batten Bar (.050) 625833 TB-FBB-.05x1x120-6o.c.-TUBE 45 6" 500 feet (50-10 ft pcs) 10,000 Coiled Batten Bar (.260) 791434 BB-R-.08x.99x100-3o.c.-CTN 72 3" 500 feet (50-10 ft pcs) 10,000 Approvals Termination products meet Factory Mutual corrosion-resistance Standard 4470. Options ZAC Anchors & Nailins 25

Roof Top Productivity Tools & Systems isofast Insulation attachment using #12 Dekfast 3x faster installation Application Fastener length 2-1/4" - 6" isofast IF 160 tool Material no: 1349029 Stand-up operation reduces back strain and fatigue. Fastener length 2-1/4" - 8" isofast IF 240 tool Material no: 1349071 #12 Belted Fasteners Collated fasteners for insulation attachment Materials: Steel thickness from 22 ga (.028 in.) through 18 ga (.045 in.): Min penetration: 3/4" Wood 2x: (1-1/2" thick): Min penetration 1" IFC/PH 70x70 (2-3/4" x 2-3/4") Galvalume stress plates IF/IG-C 82x40 (3-1/4" x 1-1/2") Galvalume stress plates Steel roof decks include all FM approved 18-20-22 ga Head Drive: #3 Phillips Head Height: Max.118" Head Dia: Max.448" Thread Major Dia:.222" Shank Dia:.167" Strength (lbs ult.): Tensile: 2410 Torsional: 76 in-lbs min Shear: 1815 Pull-out (lbs avg.): Steel: 22 ga: 513 20 ga: 695 18 ga: 787 2x dim. lumber (1" penetration): 462 Plywood 3/4" thick (through penetration): 575 Notes Dimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull-out (pounds ultimate) strength values may vary from tabulated loads depending upon the uniqueness of the application. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Length Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty. 2-1/4" 785705 DF-#12x2-1/4-PH3-E0999-BL 13 750 52,500 2-7/8" 785724 DF-#12x2-7/8-PH3-E0999-BL 16 750 52,500 3-1/4" 785746 DF-#12x3-1/4-PH3-E0999-BL 17 750 52,500 3-3/4" 785770 DF-#12x3-3/4-PH3-E0999-BL 20 750 52,500 4-1/2" 785787 DF-#12x4-1/2-PH3-E0999-BL 23 750 33,750 5" 785804 DF-#12x5-PH3-E0999-BL 26 750 33,750 6" 785813 DF-#12x6-PH3-E0999-BL 31 750 33,750 7" 1296243 DF-#12x7-PH3-E0999-BL 36 750 33,750 8 1296248 DF-#12x8-PH3-E0999-BL 41 500 15,000 IF-L-70 x 70 Insulation Plate #12 Belted Fasteners OD: 2-3/4" x 2-3/4" Square ID:.257" Thickness:.019" Finish: AZ50 Galvalume Description Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty. 2-3/4" Square 735650 PLT-S-2-3/4x2-3/4-BL 41 750 40,500 Approvals State of Florida: FL20311 26 12-1017.07

Roof Top Productivity Tools & Systems isofast Membrane attachment using #15 Dekfast 3x faster installation Application Fastener length 2" - 6" isofast IF 160 tool Material no: 1349028 Application #15 Belted Fasteners Collated fasteners for membrane attachment Materials: Steel thickness from 26 ga (.019 in.) Through 18 ga (.045 in.): Min penetration: 3/4" Wood 2x (1-1/2" thick): Min penetration 1" IF-2.375-AT (2-3/8") stacked Galvalume stress plates IF-82x50-AT (3-1/4" x 1-1/2") stacked Galvalume stress plates Steel roof decks include all FM approved 18-20-22 ga Stand-up operation reduces back strain and fatigue. Fastener length 2" - 9" isofast IF 240 tool Material no: 1349030 Head Drive: #3 Phillips Head Height: Max.130" Head Dia: Max.448" Thread Major Dia:.263" Shank Major Dia:.204" Threads per Inch: 13 Strength (lbs ult.): Tensile: 4350 Torsional: 130 in-lbs min Shear: 3700 Pull-out (lbs avg.): Steel: 22 ga: 706 20 ga: 898 18 ga: 1140 Plywood 3/4" thick (through penetration): 703 Wood 2x (1-1/2" penetration): 692 Non-FM approved decks: 26 ga: 301 24 ga: 453 Notes Dimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull-out (pounds ultimate) strength values may vary from tabulated loads depending upon the uniqueness of the application. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Length Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty. 2" 1297395 DF-#15x2-PH3-E0999-BL 21 1000 42,000 3" 1297401 DF-#15x3-PH3-E0999-BL 31 1000 30,000 4" 1060285 DF-#15x4-PH3-E0999-BL 21 500 21,000 5" 1297411 DF-#15x5-PH3-E0999-BL 25 500 15,000 6" 1297420 DF-#15x6-PH3-E0999-BL 30 500 15,000 7" 1297427 DF-#15x7-PH3-E0999-BL 35 500 15,000 8 1297433 DF-#15x8-PH3-E0999-BL 39 500 15,000 9 1297438 DF-#15x9-PH3-E0999-BL 44 500 15,000 IF-2.375-AT Membrane Plate #15 Belted Fasteners OD: 2 3/8" Round ID:.265" Thickness:.042" Finish: AZ50 Galvalume Description Material No. North American Code Carton Wt. (lbs) Carton Qty. Skid Qty. 2-3/8" Round 792759 PLT-R-2-3/8-BL 41 500 27,000 Approvals 12-1017.07 State of Florida: FL20311 27

isoweld 1-step calibration Hand-held inductor Constant monitoring of membrane surface temperature "x2" welding - two membrane thickness Application isoweld System PVC and TPO single ply membrane: 35-90 mils Polyiso insulation High density cover boards EPS insulation Foil faced insulation Mineral wool insulation Parapet wall welding Roof Top Productivity Tools & Systems Induction Welding System Innovative induction welding system which welds adhesive coated plates to single ply membranes 3-way weld verification Plate-finding search function No "false positive" welds Contents included in shipping/storage case: 1 - isoweld 3000 stand-up tool 1 - calibration template 5 - replacement protective pads for inductor 1 - instruction manual 1 - plunger cup Additional Components Magnets (8) and magnets in case #15 Dekfast Fastener TPO Plate (500/plastic pail) Hand-Held inductor PVC Plate (500/plastic pail) Tool System Material No. Material No. Component Sell Rental isoweld 3000 1349227 1351200 Hand inductor 1345222 1355217 Magnets (set of 8) 1330067 1355216 #15 Dekfast fastener Length Dependent N/A TPO Plate (500/plastic pail) 1486155 N/A PVC Plate (500/plastic pail) 1486156 N/A tool 1336394 N/A Pad for EPS/XPS application 1351805 N/A Technical Data Dimensions & Weight isoweld 3000-43"H x 21"W x 16"D isoweld 3000-32"L x 23"W x 18"D (in case) isoweld 3000-41 lbs.; 88 lbs. (in case) Magnets, set of 10-34"L x 13"W x 9"D (in case) Magnet, single - 2.7 lbs. Magnet, set of 8-53 lbs. (in case) Hand-held inductor cable length - 13' Plates, 500 pc. plastic pail - 9-7/8" x 9-7/8" x 4-3/8"; 34 lbs Approvals State of Florida: FL20311 12-1017.07 28 Pad for EPS/XPS application Electrical - minimum requirements*: Voltage: 110V (50-60 Hz) /230V Current: 20 amp, GFI protection Power: 5000 W generator, dedicated 12AWG/3 power extension cord 100' maximum length of power extension cord *Power cords of larger conductor size (10AWG/3) and shorter length are recommended for optimal performance. Recommended Application Limits: Temperature: 23ºF - 122ºF Slope: <10º

Roof Top Productivity Tools & Systems TPR-L Peel Rivet System Two-piece, aluminum magnesium alloy fastener For insulation and membrane attachment to problematic roof decks For use in decks where threaded fasteners cannot achieve required pull-out values. Provides improved pull-out values in light gauge or problematic steel decks. Corrosion-resistant components for corrosive building environments. Application TPR-L Peel Rivet For insulation and membrane attachment to problematic decks Materials: Steel: Min penetration: 1" Woodfiber: Min penetration: 1" Wood: Min penetration: 1" Lightweight Concrete: Min penetration: 1" 2" or 3" round Galvalume stress plates 2-7/8" hex Galvalume stress plates Head: Low Profile Mushroom Head Dia:.480" Shank Dia:.225" Installed Dia: 1.65" Pull-out (lbs avg.): 28 ga: 385 26 ga: 465 1/2" OSB: 330 3" Poured Gypsum: 430 Notes Dimensions are nominal inches unless noted. Ultimate values listed are the result of laboratory testing. Pull-out (pounds ultimate) strength values may vary from tabulated loads depending upon the uniqueness of the application. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. Recommend Minimum Maximum Carton Carton Length Clamping Length Clamping Length Material No. North American Code Wt. (lbs) Qty. Skid Qty. 1-1/2" 1/2" 1/2" 1241233 TPR-L-6,3x38 Peel Rivet 21 1,000 16,0000 2" 1/2" 1" 1326232 TPR-L-6,3x 51 Peel Rivet 25 1,000 16,0000 3" 7/8" 2" 1241241 TPR-L-6,3x 76 Peel Rivet 17 500 16,0000 4" 1-5/8" 3" 1241244 TPR-L-6,3x102 Peel Rivet 21 500 16,0000 5" 2-5/8" 4" 1241246 TPR-L-6,3x127 Peel Rivet 25 500 16,0000 6" 3-5/8" 5" 1241248 TPR-L-6,3x152 Peel Rivet 29 500 16,0000 7" 4-5/8" 6" 1241249 TPR-L-6,3x178 Peel Rivet 16 250 8,000 8" 5-5/8" 7" 1241250 TPR-L-3x203 Peel Rivet 18 250 8,000 9" 6-5/8" 8" 1241251 TPR-L-6,3x229 Peel Rivet 20 250 8,000 10" 7-5/8" 9" 1241252 TPR-L-3x254 Peel Rivet 22 250 8,000 TAURUS 2 Peel Rivet Pneumatic-hydraulic setting tool for the installation of TPR-L Peel Rivets Material No.: 1457802 SN2 Tong Rivet Tool Hand operated setting tool for the installation of TPR-L Peel Rivets Material No.: 838870 Pre-drill diameter for all substrates is 7mm (9/32"). The specially designed pneumatic pulling tool is required for all installations. Note: Reduce maximum clamping length by 1/4" when fastening to wood fiber or fragile substrates. Options Insulation Plates Membrane Plates Tools isoweld 29

Roof Top Productivity Tools & Systems Pre-Assembly Tool - Stealth #12 Dekfast with 3" round insulation plate When installed with Stealth tools, productivity increases up to 30% and allows the contractor to install the roof assembly in a more ergonomically correct position versus standard installation methods. Screw and plate relationship is perpendicular every time, allowing for proper and quicker installations. Application #12 Phillips w/ Round Galvalume Plate Mechanical attachment of insulation per manufacturers requirements Materials: Steel thickness from 22 ga (.028 in.) through 18 ga (.045 in.): Min penetration: 3/4" Wood 2x (1-1/2" thick): Min penetration: 1" Stealth Steel roof decks include all FM approved 18-20-22 ga Pre-assembled fasteners can be placed on the deck or loaded into the Stealth installation tools, giving the contractor the ability to use crew members in other areas of the roof project. Head Drive: #3 Phillips Head Height: Max.118" Head Dia: Max.448" Thread Major Dia:.222" Shank Dia:.167" Plate: 3" round Galvalume Material: AZ50 Galvalume Strength (lbs ult.): Tensile: 2410 Torsional: 76 in-lbs min Shear: 1815 Pull-out (lbs avg.): Steel 22 ga: 513 Steel 20 ga: 695 Steel 18 ga: 787 2x dimensional lumber (1" penetration): 462 3/4" FR Plywood: 575 #12 Hex w/ Round Galvalume Plate Mechanical attachment of insulation per manufacturers requirements Materials: Steel thickness from 22 ga (.028 in.) through 18 ga (.045 in.): Min penetration: 3/4" Wood 2x (1-1/2" thick): Min penetration: 1" Stealth Steel roof decks include all FM approved 18-20-22 ga Head Drive: 1/4" hex Head Height: Max.140" Head Major Dia.: Max.448" Thread Major Dia:.226" Shank Major Dia:.167" Plate: 3" Round Galvalume Material: AZ50 Galvalume Strength (lbs ult.): Tensile: 2410 Torsional: 76 in-lbs min Shear: 1815 Pull-out (lbs avg.): Steel 22 ga: 513 Steel 20 ga: 695 Steel 18 ga: 787 2x dimensional lumber (1" penetration): 462 3/4" FR Plywood: 575 Stealth #12 Dekfast with 3" Round insulation plate Screw Gun Adaptor: Dewalt Continued on following page 30

Roof Top Productivity Tools & Systems Pre-Assembly Tool - Stealth #12 Dekfast with 3" round insulation plate Carton Carton Skid Length Material No. North American Code Steel Wood Concrete Wt. (lbs) Qty. Qty. #12 Phillips Metal 1-5/8 785690 DF-#12x1-5/8-PH3-G3-E0999-B Up to 7/8 Up to 5/8 N/A 27 500 13,500 2-1/4 785707 DF-#12x2-1/4-PH3-G3-E0999-B Up to 1-1/2 Up to 1-1/4 N/A 14 250 9,000 2-7/8 785726 DF-#12x2-7/8-PH3-G3-E0999-B Up to 2-1/8 Up to 1-7/8 N/A 15 250 9,000 3-1/4 784748 DF-#12x3-1/4-PH3-G3-E0999-B 1/2 to 2-1/2 1/4 to 2-1/4 N/A 16 250 9,000 3-3/4 785772 DF-#12x3-3/4-PH3-G3-E0999-B 1 to 3 3/4 to 2-3/4 N/A 17 250 9,000 4-1/2 785789 DF-#12x4-1/2-PH3-G3-E0999-B 1-3/4 to 3-3/4 1-1/2 to 3-1/2 N/A 18 250 6,750 5 785806 DF-#12x5-PH3-G3-E0999-B 2-1/4 to 4-1/4 2 to 4 N/A 19 250 6,750 6 785826 DF-#12x6-PH3-G3-E0999-B 3-1/4 to 5-1/4 3 to 5 N/A 20 250 6,750 7 785842 DF-#12x7-PH3-G3-E0999-B 4-1/4 to 6-1/4 4 to 6 N/A 17 200 5,400 8 785858 DF-#12x8-PH3-G3-E0999-B 5-1/4 to 7-1/4 5 to 7 N/A 19 200 5,400 #12 Hex Metal 1-5/8 790082 DF-#12x1-5/8-HW1/4-G3-E0999-B Up to 7/8 Up to 5/8 N/A 26 500 13,500 2-1/4 790088 DF-#12x2-1/4-HW1/4-G3-E0999-B Up to 1-1/2 Up to 1-1/4 N/A 14 250 9,000 2-7/8 790091 DF-#12x2-7/8-HW1/4-G3-E0999-B Up to 2-1/8 Up to 1-7/8 N/A 15 250 9,000 3-1/4 790096 DF-#12x3-1/4-HW1/4-G3-E0999-B 1/2 to 2-1/2 1/4 to 2-1/4 N/A 16 250 9,000 3-3/4 790100 DF-#12x3-3/4-HW1/4-G3-E0999-B 1 to 3 3/4 to 2-3/4 N/A 17 250 9,000 4-1/2 790103 DF-#12x4-1/2-HW1/4-G3-E0999-B 1-3/4 to 3-3/4 1-1/2 to 3-1/2 N/A 18 250 6,750 5 790106 DF-#12x5-HW1/4-E0999-B 2-1/4 to 4-1/4 2 to 4 N/A 19 250 6,750 6 790111 DF-#12x6HW1/4-G3-E0999-B 3-1/4 to 5-1/4 3 to 5 N/A 20 250 6,750 7 790116 DF-#12x7-HW1/4-G3-E0999-B 4-1/4 to 6-1/4 4 to 6 N/A 17 200 5,400 8 790119 DF-#12x8-HW1/4-G3-E0999-B 5-1/4 to 7-1/4 5 to 7 N/A 19 200 5,400 Stealth Tool Part No. Carton Qty. Stealth w/ 20" Extension 1201245 1 Approvals 12-1017.07 State of Florida: FL20311 * * Does not include #12 Hex head assemblies The standard carton package includes one #3 Phillips bit. Notes Dimensions are nominal inches unless noted. Steel roof decks include all FM-approved 18-20-22 ga. FM-approved wood decks include 3/4" F.R. plywood and 2x dimensional lumber. Structural concrete to be predrilled with standard 3/16" carbide drill bit to minimum 1/2" deeper than fastener penetration. The specific job conditions should be considered and appropriate safety factors applied when specifying the proper fasteners. 31

Reference Approved FM Fastening Patterns Factory Mutual Approved FM Fastening Patterns Standard Patterns Fasteners positioned 1 every 4 sq. ft. Standard Patterns Fasteners positioned 1 every 2 sq. ft. Enhanced Fastener Patterns 1 per 2.6 sq. ft. 1 per 3 sq. ft. 1 per 3.2 sq. ft. 1 per 2.9 sq. ft. Enhanced Fastener Patterns 1 per 2.4 sq. ft. 1 per 2.6 sq. ft. 1 per 2.6 sq. ft. 32

Reference Fastener A Word About the Specification of Fasteners Proper fastener selection takes into account where and how the fasteners are installed. Factors that must be considered include: materials being attached, environmental factors, installation conditions, and safety issues. Because product specifications, applications, and interpretations may differ, specifiers and purchasers must make their own product evaluation to be assured of suitability for the intended use. Disclosure Statement Fastener data shown herein is subject to change or correction for typographical error witout notice. All test data and ultimate values shown in this catalog are the result of laboratory testing. Specific job conditions should be considered and appropriate safety factors applied when specifying fasteners. In actual applications, proper installation techniques must be used to assure adequate performance of the fastener. Assistance and recommendations are available by contacting your SFS intec sale or customer service professional. Final selection of fasteners or accessories for use is ultimately the decision of the purchaser. While SFS intec, Inc. may assist by providing data and information for comparison, it makes no suggestions or warranties pertaining to the suitability of its products for any particular applicaion. Galvalume is a registered trademark of BIEC International, Inc. 33

Difference-making with Dekfast SFS intec has delivered fastening solutions for over fifty years to worldwide markets. The Dekfast brand is universally understood as the premier choice by specifiers and contractors for commercial low slope (flat roof) applications. Fastening Solutions Dekfast, an innovative and proven solution, is designed, manufactured and tested to achieve compliance with Factory Mutual (FM) 4470. Having a wide variety of materials, thread styles, point geometries, finishes and installation applications, Dekfast is a preferred choice for insulation and membrane attachment in wood, steel and concrete decks. Productivity Solutions SFS intec offers stand-up roofing tools to increase productivity and provide ergonomic benefits to roofing contractors. Having used SFS intec tools, contractors have reported significant rooftop productivity gains for insulation and membrane attachment in some cases productivity is "3x" faster. isofast and isoweld are unmatched in the industry and provide contractors with the edge required to get on and off of the roof more quickly. Job-Site Solutions SFS intec provides rooftop consultation, training and start-up support at no cost to the market. Our rooftop training programs are geared towards creating customer confidence and competence with all of the Dekfast brand offerings as well as our productivity tools. Job site solutions include: pull tests project start-up rooftop crew training Office-Based Solutions Supporting the Dekfast brand is our highly differentiated esolutions service offering. esolutions is a web-based application which streamlines customer order placement, tracking, invoicing, etc. esolutions empowers customers to be in control of their material requirements. Using esolutions will lead to improved order accuracy and reduced supply chain costs. 34

35

36

epost esolutions - Supply Chain innovations are just a click away eportal eshop VMI Job Pack Our Technologies Provide easier, faster & more secure working methods Reduce supply chain costs Minimize errors escan EDI Improve information availability epullout eformat Visit our website, or contact our esolutions specialist to learn more. www.sfsintecusa.com 1-800-234-4533 Manufacturing Locations Exeter Plant Lincoln Corporate Center, 41 Dennis Drive, Reading, PA 19606 Medina Plant 5201 Portside Drive, Medina, OH 44256 Wyomissing Plant 1045 Spring Street, PO Box 6326, Wyomissing, PA 19610 Canada Plant 40 Innovation Drive, Dundas, ON L9H 7P3 US Service Centers: Contact Us Toll Free: 1-800-234-4533 Toll-free Fax: 888-485-4225 Northeast: 1045 Spring Street, PO Box 6326, Wyomissing, PA 19610 T: 610-376-5751 F: 610-376-8551 Northern Midwest: 500 West 3rd Avenue, Durant, IA 52747 T: 563-785-4990 F: 563-785-6997 Toll-free Fax: 888-211-4211 Southeast: 675 Progress Center Ave., Unit M, Lawrenceville, GA 30043 T: 770-995-5256 F: 770-995-3782 West Coast: 2426 Port Street, West Sacramento, CA 95691 T: 916-373-9912 F: 916-373-0176 Toll-free Fax: 888-488-8332 Canada Service Center: Contact Us Toll-Free : 1-866-847-5400 Toll-free Fax: 855-858-5300 40 Innovation Drive, Dundas, ON L9H 7P3 T: 905-689-5401 F: 905-689-9474 2017 SFS intec / Printed in USA Technical Changes Reserved January 2017 Technical advice and sales service SFS intec Division Construction 1045 Spring Street PO Box 6326 US-Wyomissing, PA 19610 800 234 4533 T +1 610 376 5751 F +1 610 376 8551 us.construction@sfsintec.biz www.sfsintecusa.com SFS intec - Canada 40 Innovation Drive Dundas, ON L9H 7P3 T +1 905 689 5401 ca.info@sfsintec.biz www.sfsintec.ca