Harmonic restraint earth fault or single-phase overcurrent protection

Similar documents
Transformer differential protection

Time over/underfrequency relay with protection assemblies

Transformer and generator time-overexcitation relay and protection assemblies RXLK 2H and RALK

Time relay RXKA 1. (xx jpg) RXKA 1

Compact current relay and protection assemblies RXHL 401 and RAHL 401

Time-overcurrent relays and protection assemblies

)HDWXUHV Voltage restraint overcurrent stage with five different inverse or definite time characteristics

Modular multifunction generator protection

Current and voltage measuring relays RXIK 1, RXEEB 1 and RXIB 24

Earth fault protection for isolated neutral systems with frequency converters

Phase and neutral overcurrent protection

Transformer differential protection RADSB

RARIC Shaft current protection

Stabilized Differential Relay SPAD 346. Product Guide

RXFK 2H and RAFK Time over/underfrequency relay and protection assemblies

Overcurrent Protection / 7SJ45

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

INDICATOR TYPE RXSK 2H

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

SPAD 346 C Stabilized differential relay

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

SPAE 010, 011 High Impedance Protection Relay

presentation contents application advantages

SPECIFICATION FOR OVERCURRENT RELAYS

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

Type CP-S, CP-C & CP-A Switch mode

RAIDK, RAIDG, RAPDK and RACIK Phase overcurrent and earth-fault protection assemblies based on single phase measuring elements

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

IRI1-ER - Stabilized Earth Fault Current Relay

IRI1-ER - Stabilized Earth Fault Current Relay. Manual IRI1-ER (Revision A)

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Electronic timer CT-TGD.22

Plug-in microprocessor controlled multifuncional relay with automatic shorting of c.t.

Protection and control. Sepam range Sepam 100 LA Self-powering protection. Merlin Gerin Square D Telemecanique

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

LINAX 4000L Continuous-line recorder

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

SPAA 120 C and SPAA 121 C Feeder protection relay

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

POINTAX 6000L2 Point Recorder

Railway application RER670 Version 2.2 IEC Type test certificate R E L I O N 670 SERIES

High-Tech Range. IRI1-ER- Stablized Earth Fault Current Relay. C&S Protection & Control Ltd.

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

SPAJ 135 C. Combined overcurrent and earth-fault relay SPAJ 135 C. User s manual and Technical description. U aux V ~ V.

SPAJ 110 C. Earth-fault relay SPAJ 110 C. User s manual and Technical description. U aux V ~ V f n. n ( I o>> SPCJ 1C8

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

83 Series - Modular timers 16 A. Features

Instantaneous Overcurrent Relay

CP-T range Product group picture

Digital Grid Products. SICAM Fault Sensor Indicator (FSI) The Guardian for your Overhead Line Networks

Multi-voltage Multi-function. Wiring diagram (without control signal)

SPAS 348 C. Feeder Protection Relay. User s manual and Technical description SPAS 348 C V ~ V. t 2 > [ s ] f n = 50Hz 60Hz

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-SDS.22

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy

Power supply CP-E 24/2.5

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

Relion 670 series. Generator protection REG IEC Type test certificate

Power supply CP-E 24/20.0

RE17LLBM asymmetrical flashing relay s V AC - solid state output

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Solid-state Timer H3DS

DEIF A/S. Insulation monitor. Type SIM-Q

Installation / Monitoring Technique

Automatic synchronising relay

Three-phase monitoring relays

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Power supply CP-D 24/4.2 Primary switch mode power supply

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

24 V DC, 12 W output 12 V DC, 12 W output 24 V DC, 36 W output

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

Product Specification sheet

CP-T range Benefits and advantages

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Transcription:

Harmonic restraint earth fault or single-phase overcurrent protection Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970885) Features Sensitive earth fault protection for solidly earthed networks Rated frequency 50 or 60 Hz 2nd harmonic restraint for stability at transformer inrush Operation blocked by 2nd harmonic component >20% of the fundamental current Operate current is settable 1-1,2-1,5-1,8 times a scale constant Scale constant is reconnectible 0,03-0,06-0,12 A or 0,2-0,4-0,8 A Operate time 50-70 ms at 3 x pick-up Reset ratio >90% Variants available with definite or inverse time delayed output Application The relay is above all intended as sensitive, delayed earth-fault protection for use in solidly earthed power systems. The most typical application is as a sensitive back-up protection in a transformer neutral or at a power line. When a transformer is switched in and energized, a high inrush current usually appears. It can reach a peak value of several times the transformer s rated current, and it is gradually damped to a normal magnetizing current of some percent of rated current. The dampening is relatively slow, and the inrush current can last for several seconds. Normal current relays respond to this inrush current. In particular, earth current relays, which are sensitively set and/or have a short delay, run a risk of unwanted operation from this inrush current. By applying a second harmonic restraint to the current relay, the possibility to apply sensitive protection with a short delay is very much improved. The restraint is arranged to prevent operation, when amount of second harmonic current component compared to the fundamental current passes a certain value. The transformer inrush current is heavily distored and has a high percentage of second harmonic, which prevents relay operation. The harmonic restraint unit RXISB 4 can be arranged to enable operation of another measuring relay, for instance RXIDK 2H with inverse time delay. In such cases RXISB 4 is set to operate at a lower current than the enabled relay.

Page 2 Design is available in a basic variant with definite time delay, flag indication and test switch, and in other variants in combinations with overcurrent inverse time relays or counter for elapsed time.the measuring relay RXISB 4 can also be delivered separately. The basic variant of includes an RTXP 18 test switch, an RXTUG 21H dc-dcconverter, an RXISB 4 restraint over-current relay, an RXKL 1 time relay and an RXSF 1 flag relay. The measuring relay RXISB 4 contains an input transformer, two circuit boards with circuits for operation and restraint, and an output relay with three make contacts. The input transformer is reconnectible for three different scale constants. The fundamental frequency operate value is set with a selector switch on the front of the relay. The value is adjustable in four steps from 1,0 to 1,8 times the scale constants. The function of the relay is blocked by the restraining circuit for second harmonic current larger than 20% of the fundamental current. The RXISB 4 relay is supplied with ±24V dc from an RXTUG 22H dc-dc-converter providing a galvanic separation from the auxiliary supply voltage (24...250 V). The converter has a green LED and a relay for signalling loss of dc supply. The time relay RXKL 1 is used for definite-time delay of the operation. The delay can be set between 20 ms and 99 h. The flag relay RXSF 1 provides a red flag and three make contacts to indicate tripping. The test switch RTXP 18 is a part of the COMBITEST system. By use of a test plug handle RTXH 18 connected to a test set, a complete secondary test of the protective relay can be done without any disconnections of cables. Besides the basic variant, the following variants are also available: - with definite-time delay, and an RXTNI 21 counter (requires ac supply) to measure the elapsed time and RXSF 1 flag relay with yellow flag for starting and red flag for trip indications. - with inverse-time current relays type RXIDK 2H or RXIDG 21H.

Page 3 Technical data Table 1: Energising quantities, rated values and limit Quantity Rated values Rated frequency f r 50 or 60 Hz Scale range 0,03-0,216 A or 0,2-1,44 A Operate value Adjustable in steps 1,0, 1,2, 1,5 and 1,8 x scale constant I s Scale constant I s Reconnectible 0,03, 0,06 and 0,12 A or 0,2, 0,4 and 0,8 A Reset ratio > 90% Degree of restraint (I2/I1) Operate time Reset time Critical impulse time Graduation error Overload capacity for relays with scale factor I s =0,03 A I s =0,06 A I s =0,12 A I s =0,2 A I s =0,4 A I s =0,8 A Operation is blocked when the second harmonic component is > 20% of the fundamental current 50-70 ms at I 3 x set operating value < 70 ms Approx. 35 ms at I = 3 x set operating value < 6% of set value Continuously For 1 s 1,5 A 40 A 4 A 70 A 4 A 70 A 10 A 240 A 20 A 350 A 20 A 50 A Auxiliary dc voltage EL 24-250 V dc, +10%, -20% Power consumption: Current measuring circuit at I= I s = 0,03 and 0,06 A 0,12 and 0,2 A 0,4 A 0,8 A Aux. voltage circuit Permitted ambient temperature < 1 mva < 2 mva 4 mva 15 mva < 10 W -20 C to +55 C Table 2: Insulation test (IEC 255- Dielectric test: Current circuits Other circuits Impulse voltage test 2,5 kv 50 Hz, 1 min 2,0 kv 50 Hz, 1 min 5,0 kv, 1,2/50 µs, 0,5 J

Page 4 Technical data (cont d) Table 3: Electromagnetic compatibility test Power frequency test (SS 436 15 03) 500 V, class PL 4 Fast transient test (SS 436 15 03) 4-8 kv, class PL 4 1 MHz burst test (IEC 255-22-1) Electrostatic discharge (IEC 255-22-2) Radiated electromagnetic field test (IEC 255-22-3) Fast transient test (IEC 255-22-4) Permissible interruption in auxiliary dc voltage (IEC 255-11) without unwanted operation without interrupting the operation 2,5 kv, class III 8 kv, class III 10 V/m, 427 MHz 4 kv, class IV 2-200 ms 40 ms at 110 V dc 220 ms at 250 V dc Table 4: Mechanical tests Vibration test (IEC 255-21-1 Response test Endurance test Shock tests (IEC 255-21-2) Response test Withstand test 0,035 mm/0,5 g, 10-150-10 Hz, Class I 1 g 10-150-10 Hz, 20 sweeps, Class 1 5 g, 11 ms, 3 pulses, Class 1 15 g, 11 ms, 3 pulses, Class 1 Bump test (IEC 255-21-2) 10 g, 16 ms, 1000 pulses, Class 1 Seismic tests (IEC 255-21-3) horizontal axis vertical axis 1 g, 5-35-5 Hz, Class I 0,5 g, 5-35-5 Hz Class I Table 5: Contact data of RXISB Number of contacts Max. system voltage dc/ac Current-carrying capacity 200 ms/1 s continuously 3 make contacts 250/250 V 90/50 A 5 A Making and conducting capacity L/R > 10 ms 200 ms/1 s 30/10 A Breaking capacity for ac, PF >0,4, 220V dc, L/R <40 ms 48 V 110 V 220 V 250 V 8,0 A 1,0 A 0,4 A 0,2 A 0,15 A Contact data for time relay RXKL 1, time-overcurrent relays RXIDK 22H and RXIDG 21H, and flag relay RXSF 1 are given in the respective catalogue. See References.

Page 5 Diagrams 107 431 TRIP, ALARM ETC. 213 215 217 214 216 218 101 118 128 225 126 127 128 441 415 EARTH FAULT OR 1-PHASE OVERCURRENT PROTECTION WITH HARMONIC RESTRAINT 18C 101 107 4U U< 117 116 118 LOSS OF EL 316 318 317 101 RXTUG 22H 107 RXISB 4 + + + + + - EL Fig. 1 Circuit diagram 1MRK 000 052-AB for RXISB 4 with RXTUG 22H L1 L2 L3 ALT 1 1MRK000052-BB 101:3A 101:4A ENABLE ETC. TRIP ALARM ETC. LOSS OF EL 113:217 101:17A 101:16A 325:15 107:316 107:318 107:317 101:2A 325:13 101:13A 101:1A 101:18A - U< 107:116 107:118 ALT 2 EARTHFAULT OR 1-PHASE OVERCURRENT PROTECTION WITH HARMONIC RESTRAINT 30C 101 107 113 125 325 4U + + + + + - + - E ALT 3 101 RTXP 18 107 RXTUG 22H 113 RXISB 4 125 RXKL 1 325 RXSF 1 Fig. 2 Terminal diagram 1MRK 000 052-BBA, basic variant

- Page 6 Diagrams (cont d) L1 L2 L3 ALT 1 1MRK 000052-CB RAIS 101:3A EARTHFAULT OR 1-PHASE OVERCURRENT PROTECTION WITH HARMONIC RESTRAINT TRIP ETC. ALARM ETC. LOSS OF EL ENABLE ETC. 101:17A 101:16A 331:15 331:25 107:316 107:318 113:217 + U< 101:4A ALT 2 36C 101 107 113 125 325 4U 331 101:7A 101:2A 331:13 107:317 101:1A 101:18A + + + + + - 107:116 107:118 + - E 125:228 331:23 R ALT 3 101 RTXP 18 107 RXTUG 22H 113 RXISB 4 125 RXTNI 21 325 RXKL 1 331 RXSF 1 Fig. 3 Terminal diagram 1MRK 000 052-CBA, with RXTNI 21 + - L1 L2 L3 ALT 1 1MRK000052-DB,-EB EARTHFAULT OR 1-PHASE OVERCURRENT PROTECTION WITH HARMONIC RESTRAINT 36C 101 107 113 125 131 & I> ALT 2 4U 1) 2) 3) 101 14A 125:328 U ALT 3 101 RTXP 18 107 RXTUG 22H 113 RXISB 4 125 RXIDG 21H / RXIDK 2H 131 RXSF 1 4) 107:316 107:317 131:13 13A 107:116 107:118 1) TRIP 2) ALARM ETC. 3) START ETC 4) LOSS OF EL + + + + + - + - E Fig. 4 Terminal diagram 1MRK 000 052-DBA, with RXIDK 2H or RXIDG 21H

Page 7 Ordering Specify: Quantity Ordering No. from the ordering table Auxiliary voltage RL; 110 or 220 V ac Code A,D (for separately delivered RXISB 4 a ±24 V supply from a dc/dc converter RXTUG 22H is required) Desired wording on the lower half of the test switch face plate max. 13 lines with 14 characters per line. Mounting and connection: is delivered on apparatus bars. For additional mounting, a case for 19" rack or panel mounting is required. For information on COMBIFLEX, accessories and mounting systems, see References. Ordering table Variant Dimensions Weight Circuit/ Terminal diagram basic variant 4U 30C 4,3 kg 1MRK 000 052-BB / 1MRK 000 052-BBA with RXTNI 21 4U 36 C 4,9 kg 1MRK 000 052-CB / 1MRK 000 052-CBA with RXIDG 21H 4U 36 C 4,8 kg 1MRK 000 052-DB / 1MRK 000 052-DBA with RXIDK 2H 4U 36C 4,8 kg 1MRK 000 052-EB / 1MRK 000 052-DBA Ordering No. 1MRK 000 052-BA 1MRK 000 052-CA 1MRK 000 052-DA 1MRK 000 052-EA Overcurrent relays with inverse characteristics Type Scale range Overload capacity Article No. Code RXIDG 21H 0,015-0,65 A 2/4 A 1MRK 000 839-AA None RXIDK 2H 0,015-0,65 A 2/4 A 1MRK 000 838-FA A11 RXIDK 2H 0,075-3,25 A 4 A 1MRK 000 838-AA A1 Measuring relay in Type Frequency Scale range Article No. Code RXISB 4 50 Hz 0,03-0,216 A 1MRK 000 034-AA D1 RXISB 4 50 Hz 0,2-1,44 A 1MRK 000 034-BA D2 RXISB 4 60 Hz 0,03-0,216 A 1MRK 000 034-CA D3 RXISB 4 60 Hz 0,2-1,44 A 1MRK 000 034-DA D4

Page 8 References Time relay RXKL 1 Flag relay RXSF 1 Time over-current relays RXIDK 2H and RXIDG 21H Test system COMBITEST DC-DC converter RXTUG 22H COMBIFLEX connection and installation components Relay mounting systems Dimensions COMBIFLEX modular identification system Counter RXTNI 21 1MRK 508 002-BEN 1MRK 508 015-BEN 1MRK 509 002-BEN 1MRK 512 001-BEN 1MRK 513 001-BEN 1MRK 513 003-BEN 1MRK 514 001-BEN 1MRK 514 004-BEN 1MRK 514 005-BEN B03-9232 Manufacturer ABB Automation Products AB Substation Automation Division SE-721 59 Västerås Sweden Tel: +46 (0) 21 34 20 00 Fax: +46 (0) 21 14 69 18