CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

Similar documents
SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

Tri-Rated Flexible PVC Equipment Wire

non-sheathed cables for fixed Wiring integrity is doing the right thing, even if nobody is Watching JiM stovall

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

Kerman & Kavian Cable Industries ( KCI )

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

Welding Cables Rubber Insulated

Selection table for flat & ribbon cables

UNIRAIL D RS485 and BUS cables

Switchgear Wire. Specification Table. Page <1> 31/08/10 V1.0. : Varies with colour and packing.

H07RN-F BS EN Flexible Rubber Cable

Mineral-insulated resistance thermometers to EN

Instrumentation Cables

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

EDS LV WAVEFORM MAINS CABLE RATINGS

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

SUBMERSIBLE PUMP CABLES

How to order. Payment options. Delivery options. Online acatalog. By phone + (44) By fax + (44)

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

Armoured Power and Control Cables to BS7917

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

Armoured Power and Control Cables to BS6883

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

Continuous Flex Data Cable

NETWORK CONNECTIVITY SYSTEMS

CAT 5e UTP Cable: NETSET BOX [305m], indoor

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

Servo Cable Selection

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

FLEXIBLE MULTI CORE CABLES

CUSTOM DESIGN COAXIAL CABLES BY SICAB

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

Notes 3 Explanatory Information 4-10

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

16-2-C Series. Specification Table. Page <1> 19/06/10 V1.0. : Varies with colour and packing.

Armoured Power and Control Cables Fire Resistant

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

MarineLine YOZp 0,6/1 kv

COPPER + LWL RAW CABLES

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

PRODUCT INFORMATION UNITRONIC BUS PB

List Price w.e.f. 02nd January, 2018

Armoured Instrumentation Cables to BS6883

MULTIMEDIA CABLE H6091ZHB

Motor, Servo & Feedback Cables

FLAME RETARDANT INSTRUMENTATION CABLE. Application Standard

Photo: HELUKABEL. Motor, Servo & Feedback Cables D 1

Installation Recommendations

Data sheet C6 A RJ45 field plug pro 360

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

Fireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485

Data sheet C6 A RJ45 field plug pro

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

EXCELLENT ELECTRICAL PERFORMANCES

Medium Voltage Power Cables

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

SAC-3P- 5,0-PUR/M12FR SH

Trunking. light grey in U23X. Industrial Catalogue

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

CIR (Crush & Impact Resistant) VFD Power Cable

Data sheet. C5 RJ45 field plug pro 2P 360 PROFINET. Illustrations P/N 130E405042PE EAN Product specification. Page 1/

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

Data sheet C6 A RJ45 field plug pro 360

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813

SAC-5P- 1,5-PUR/M12FS SH

Control Cable. 1 Executive Standards. 3 Type and Designation. PVC insulated PVC sheathed control cable. PE insulated PE sheathed control cable

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

VSD cables in. Working with. industrial & automation applications

Microwave Coax Cable

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Copper and Fiber Optic Cables

Data sheet C5 RJ45 field plug pro 2P PROFINET

kv: medium voltage reeling cable with fibreoptics

Data sheet C6 A RJ45 field plug pro 360


H05Z-K / H07Z-K BS EN LSZH Wire

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

LTE high-performance coaxial cables (RG replacement)

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

CABLE TRADE PRICE LIST TRADE PRICE LIST NO.TR21

Cables for data transmission in industrial automation

TNC Male Connector Crimp/Solder Attachment for RG214, RG9, RG225, RG393

Data sheet E-DAT Industry RJ45 plug black Cat.6 Class E A

FieldLink MC at 20 x outer diameter Torsion

Railway products. Edition 2014

Sub-Miniature Cable. Specifications: Page <1> 05/04/12 V1.1

GANPATI ENGINEERING INDUSTRIES Braided Copper Wire

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Allied Cables INTRODUCTION

Transcription:

PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED ISSUE DATE: 04/02/2016 PAGE: 1

Manufactured generally to BS EN 50525-2-11 Plain Annealed Flexible Copper Conductors / PVC Insulated / Tinned Copper Wire Braid (TCWB) / PVC Sheathed. 300/500V Conductor : Plain Annealed Copper Class 5 to BS EN 60228 Insulation: PVC Type TI2 to BS EN 50363-3 Braiding: Tinned Copper Wire Braid (TCWB) Sheath: PVC Type TM2 to B EN 50363-4-1 Current Ratings: For current ratings refer to table 4F1 and 4F3 of BS7671 IEE Wiring Regulations Seventeenth Edition. The cable is designed to be used as an interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. The shielding on CY cable helps to reduce electromagnetic interference; therefore CY cable is commonly used in situations where reduced interference signal and data transmission is required. If protected correctly electricians have found that CY can be useful in outdoor projects - however it is recommended and most commonly used projects in dry or moist conditions. STANDARD CORE COLOURS MINIMUM MAXIMUM MINIMUM OPERATING OPERATING BENDING 2 CORE 1 2 TEMPERATURE TEMPERATURE RADIUS 3 CORE + BLACK NUMBERED (some sizes are available colour coded) -15 C 70 C 6 x Ø for indoor ISSUE DATE: 04/02/2016 PAGE: 2

Reference Number Nominal Cross Sectional Area of Conductor (mm²) Nominal Stranding of Conductor Thickness of insulation Thickness of sheath Diameter Lower Limit Diameter Upper Limit Approximate Weight (kg/km) CY0.52C 0.5 16/0.2 0.5 0.6 4.7 6.7 45 CY0.752C 0.75 24/0.2 0.5 0.6 5.3 7.3 54 CY1.02C 1.0 32/0.2 0.5 0.6 5.5 7.5 60 CY1.52C 1.5 30/0.25 0.5 0.6 6.1 8.1 70 CY2.52C 2.5 50/0.25 0.5 0.6 7.3 9.3 104 CY0.53C 0.5 16/0.2 0.5 0.6 5.1 7.1 53 CY0.753C 0.75 24/0.2 0.5 0.6 5.6 7.6 65 CY1.03C 1.0 32/0.2 0.5 0.6 5.8 7.8 73 CY1.53C 1.5 30/0.25 0.5 0.6 6.5 8.5 90 CY2.53C 2.5 50/0.25 0.5 0.6 7.9 9.9 140 CY0.54C 0.5 16/0.2 0.5 0.6 5.6 7.6 63 CY0.754C 0.75 24/0.2 0.5 0.6 6.1 8.1 77 CY1.04C 1.0 32/0.2 0.5 0.6 6.3 8.3 89 CY1.54C 1.5 30/0.25 0.5 0.6 7.1 9.1 108 CY2.54C 2.5 50/0.25 0.5 0.6 8.7 10.7 173 CY4.04C 4.0 56/0.3 0.5 0.6 10.4 12.4 236 CY6.04C 6.0 84/0.3 0.5 0.8 12.1 14.1 339 Weight and dimensional information is provided as an approximate guide only. ISSUE DATE: 04/02/2016 PAGE: 3

Reference Number Nominal Cross Sectional Area of Conductor (mm²) Nominal Stranding of Conductor Thickness of insulation Thickness of sheath Diameter Lower Limit Diameter Upper Limit Approximate Weight (kg/km) CY0.55C 0.5 16/0.2 0.5 0.6 6.0 8.0 76 CY0.755C 0.75 24/0.2 0.5 0.6 6.6 8.6 91 CY1.05C 1.0 32/0.2 0.5 0.6 6.9 8.9 105 CY1.55C 1.5 30/0.25 0.5 0.6 7.7 9.7 125 CY2.55C 2.5 50/0.25 0.5 0.6 9.3 11.3 206 CY0.757C 0.75 24/0.2 0.5 0.6 7.1 9.1 115 CY1.07C 1.0 32/0.2 0.5 0.6 7.7 9.7 139 CY1.57C 1.5 30/0.25 0.5 0.6 8.6 10.6 160 CY2.57C 2.5 50/0.25 0.5 0.6 10.1 12.1 267 CY0.512C 0.5 16/0.2 0.5 0.6 8.5 10.5 140 CY0.7512C 0.75 24/0.2 0.5 0.6 9.4 11.4 177 CY1.012C 1.0 32/0.2 0.5 0.6 9.7 11.7 207 CY1.512C 1.5 30/0.25 0.5 0.6 11.1 13.1 279 CY0.7518C 0.75 24/0.2 0.5 0.6 10.9 12.9 250 CY1.018C 1.0 32/0.2 0.5 0.6 11.7 13.7 295 Weight and dimensional information is provided as an approximate guide only. ISSUE DATE: 04/02/2016 PAGE: 4

Multicore Loading In practice, the majority of cores in a multicore control cable of 7 cores and above carry only small or intermittent current and a current rating based on the assumption that all cores are equally loaded is quite unrealistic. In most cases only two cores, the line and neutral feed cores are likely to approach the maximum permitted loading. The current rating for twin core cable can therefore be used in these cables. Where more than two cores are known to carry an appreciable current, the multiplying factors applicable to the two core ratings are given below. The normal current rating for twin cable may also be used in cases where the number of cores carrying appreciable current does not exceed the square root of the total number of cores in the cable. Number of loaded cores 3 4 5 6 7 10 12 14 Multiplying factor 0.87 0.78 0.72 0.67 0.63 0.56 0.53 0.51 Number of loaded cores 19 24 27 30 37 44 46 48 Multiplying factor 0.45 0.42 0.40 0.39 0.36 0.34 0.33 0.33 ISSUE DATE: 04/02/2016 PAGE: 5