LYNXEYE XE-T. < 380 ev. Innovation with Integrity. Energy. Resolution. High-Resolution Position Sensitive Detector with Superb Energy Resolution XRD

Similar documents
LYNXEYE XE. Innovation with Integrity. High-Resolution Energy-Dispersive Detector for 0D, 1D, and 2D Diffraction XRD

X-RAY OPTICS FOR TWO-DIMENSIONAL DIFFRACTION

Lesson 2 Diffractometers

Pseudo-3D pixel detectors for powder diffraction Martijn Fransen

ARTAX. Innovation with Integrity. Portable Micro-XRF Spectrometer. Micro-XRF

BRUKER ADVANCED X-RAY SOLUTIONS. SPECTROMETRY SOLUTIONS ARTAX mxrf SPECTROMETER

M4 TORNADO PLUS. Innovation with Integrity. Super Light Element Micro-XRF Spectrometer. Micro-XRF

Data Collection with. VÅNTEC-2000 Detector

MICRO XRF OF LIGHT ELEMENTS USING A POLYCAPILLARY LENS AND AN ULTRA THIN WINDOW SILICON DRIFT DETECTOR INSIDE A VACUUM CHAMBER

Improving the Collection Efficiency of Raman Scattering

Cr, Co, Cu, Mo, Ag (others on request) Mean Reflectivity: R > 70%

X-Ray Spectroscopy with a CCD Detector. Application Note

Pixel Array Detectors: Counting and Integrating

MICROFOCUSING X-RAY EQUIPMENT FOR THE LAB DIFFRACTOMETER

Standard Instructions for the Bruker D8 Advance Diffractometer, EPFL Valais Bragg Brentano and GID (Reflection)

WIDE ANGLE GEOMETRY EDXRF SPECTROMETERS WITH SECONDARY TARGET AND DIRECT EXCITATION MODES

By using patented polycapillary optics this diffractometer obviates the need for monochromators and collimators for linear projection of X-Rays.

RANDY W. ALKIRE, GEROLD ROSENBAUM AND GWYNDAF EVANS

Applications of New, High Intensity X-Ray Optics - Normal and thin film diffraction using a parabolic, multilayer mirror

Bruker D8 HRXRD Collecting X-Ray Reflectivity Data using the PathFinder Detector

DEVELOPMENT OF A WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE SPECTROMETER USING A MULTI-CAPILLARY X-RAY LENS FOR X-RAY DETECTION

v tome x m microfocus CT

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

R-AXIS RAPID. X-ray Single Crystal Structure Analysis System. Product Information

Advancing EDS Analysis in the SEM Quantitative XRF. International Microscopy Congress, September 5 th, Outline

Case Study: Custom CCD for X-ray Free Electron Laser Experiment

Product Information Version 1.0. ZEISS Xradia 810 Ultra Nanoscale X-ray Imaging at the Speed of Science

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

Technical Data. Horizontal or vertical goniometer, Theta/2Theta or Theta/Theta geometry

Rigaku Innovative Technologies Europe (RITE) Presented by: Dr.Peter Oberta

Dinnebier & Billinge, TA+PXRD course - Part 1, The Equipment

Test procedures Page: 1 of 5

K-edge subtraction X-ray imaging with a pixellated spectroscopic detector

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Real-Time Scanning Goniometric Radiometer for Rapid Characterization of Laser Diodes and VCSELs

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

1/8 m GRATING MONOCHROMATOR

GSPC detectors development for neutron reflectometry and SANS Instruments WP22 / Task 22.2

Observational Astronomy

IBEX TECHNOLOGY APPLIED TO DIGITAL RADIOGRAPHY

BL39XU Magnetic Materials

Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design

PSI with the Swiss Light Source SLS. Christian Broennimann. Paul Scherrer Institut 5232 Villigen PSI

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Diamond X-ray Rocking Curve and Topograph Measurements at CHESS

AutoMATE II. Micro-area X-ray stress measurement system. Highly accurate micro area residual stress

Agilent Xcalibur and Gemini X-ray Diffractometers ENHANCED CHEMICAL CRYSTALLOGRAPHY SOLUTIONS

Basic P-XRD instructions for Operating the Instrument

ANALYTICAL MICRO X-RAY FLUORESCENCE SPECTROMETER

Properties of Structured Light

True simultaneous ICP-OES for unmatched speed and performance

Quantax 100 Low-Cost EDS System. Innovation with Integrity

Superior ICP-OES optical design for unmatched speed and performance

PSPC/MDG 2000 X-RAY MICRODIFFRACTOMETER. Product Information

Advances in X-Ray Scintillator Technology Roger D. Durst Bruker AXS Inc.

Supplementary Figure 1

Manufacturing Metrology Team

LONG TERM STATISTICS OF X-RAY SPECTROMETERS

CESRTA Low Emittance Tuning Instrumentation: x-ray Beam Size Monitor

Lab Report XRF 441 Elemental distribution analysis on geological samples with the M4 TORNADO

Instructions XRD. 1 Choose your setup , Sami Suihkonen. General issues

Digital Radiography : Flat Panel

OCT Spectrometer Design Understanding roll-off to achieve the clearest images

State-of-the-art thin film X-ray optics for synchrotrons and FEL sources. Frank Hertlein Incoatec GmbH Geesthacht, Germany

Macromolecular SAXS. Size Shape Flexibility Assemblies Solution State. Solution scattering from biological molecules

Evaluating the Performance of a Commercial Silicon Drift Detector for X-ray Microanalysis

Veraviewepocs 2D High Speed Panoramic X-Ray Crystal Clear Images with Reduced Radiation

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

Nano Beam Position Monitor

Novel laser power sensor improves process control

Atomic and nuclear physics

Micro-sensors - what happens when you make "classical" devices "small": MEMS devices and integrated bolometric IR detectors

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

Amorphous Selenium Direct Radiography for Industrial Imaging

WITec Alpha 300R Quick Operation Summary October 2018

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

MS260i 1/4 M IMAGING SPECTROGRAPHS

M6 JETSTREAM. Innovation with Integrity. Large Area Micro X-ray Fluorescence Spectrometer. Micro-XRF

Small Angle Scattering Platform for Structural Biology

SPECTRAL SCANNER. Recycling

Zaidi Embong and Husin Wagiran Physics Department, University Of Technology Malaysia, P.O Box 791, 80990, Johor Baharu

DATA COLLECTION WITH R-AXIS II, AN X-RAY DETECTING SYSTEM USING IMAGING PLATE

Monochromator 611 Manual

How Does One Obtain Spectral/Imaging Information! "

Product Information Version 1.1. ZEISS Xradia 410 Versa Submicron X-ray Imaging: Bridge the Gap in Lab-based Microscopy

IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison

A Framed Monochromatic X-Ray Microscope for ICF

DESIGN AND MEASUREMENT WITH A NEW PORTABLE X-RAY CAMERA FOR FULL-FIELD FLUORESCENCE IMAGING

Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

Bruker Nano. M4 tornado. High performance micro-xrf spectrometer. think forward

Multi-kW high-brightness fiber coupled diode laser based on two dimensional stacked tailored diode bars

Parameter Selection and Spectral Optimization Using the RamanStation 400

Evaluation of laser-based active thermography for the inspection of optoelectronic devices

TOWARDS FAST RECIPROCAL SPACE MAPPING

Spatial resolution. Spatial resolution

Components of Optical Instruments

Precise Theta/2-Theta Measurement (PB/PSA) Part

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

Transcription:

Energy < 380 ev Resolution High-Resolution Position Sensitive Detector with Superb Energy Resolution The is the next generation "Compound Silicon Strip" detector with superb energy resolution for ultrafast 0D, 1D, and 2D X-ray diffraction. The is particularly optimized to meet the increasing demands in X-ray diffraction of highest count rate capabilities, best angular resolution (peak widths), and best energy resolution. The unique combination of sensor chip and front-end electronics as realized in the makes it the highest performing detector on the market in terms of both data and manufacturing quality. High-speed data acquisition up to 450 times faster than a conventional point detector system Superior energy resolution better than 380 ev Cu radiation making Kß filters and secondary monochromators redundant Operation with all common characteristic X-ray emission lines (Cr, Co, Cu, Mo, and Ag radiation) Outstanding angular resolution (peak widths) and perfect line profile shapes Outstanding peak-to-background ratio for highest sensitivity and data quality No defective channels at delivery time guaranteed Innovation with Integrity XRD

Specimen fluorescence? You don t need any mirrors or monochromators! Fundamentally, sample fluorescence is generated by the incident beam and can only be effectively reduced by choosing an appropriate wavelength. When fluorescence is present, it can only be filtered using suitable diffracted beam path components such as mirrors, monochromators, and energy discriminating / dispersive detectors. Mirrors and monochromators are critical to alignment, and are usually tailored for a single wavelength. While mirrors always compromise the instrument resolution achievable in the traditional Bragg-Brentano geometry, diffracted beam monochromators are intensity killers. Typical intensity losses range from more than 70% for point detectors up to more than 90% for one-dimensional detectors, compared to unfiltered radiation. At such losses, a one-dimensional detector loses all its advantages and operates at intensity levels close to traditional point detectors. Counting statistics are poor, resulting in noisy patterns and thus very poor lower limits of detection. Furthermore, present diffracted beam mirrors or monochromators cannot be used for two-dimensional diffraction, leaving an important gap for a huge range of applications where two-dimensional diffraction is of advantage. The overcomes these issues thanks to its unprecedented filtering of fluorescence and Kß radiation, utilizable for both one- as well as two-dimensional diffraction applications. This is demonstrated in Figures 1-2 for a natural hematite specimen (Fe-fluorescence with Cu-radiation) by comparing data acquired with the and a scintillation counter with secondary monochromator. Figure 1 demonstrates the superb filtering of Fefluorescence without any loss of peak intensity versus unfiltered radiation. Remarkable is the huge intensity gain by a factor of 450 by comparison to the secondary monochromator data. As a consequence, the LYNXEYE XE-T has an enormous advantage in terms of intensity and counting statistics and thus lower limits of detection. This is demonstrated in Figure 2. A second phase, calcite, is easily detected using the, but is far below the detection limit in the secondary monochromator data. Figure 1: Unfiltered (black line) and filtered (red line) data demonstrating the superb filtering of fluorescence radiation by the. The intensity gain over the secondary monochromator data (blue line) amounts to a factor of about 450. Figure 2: Zoomed region from Fig. 1 (21-27 2θ) illustrating the unparalleled lower limits of detection capabilities of the. Secondary monochromator data (blue line) scaled to the same maximum peak intensity as the data (red line). Calcite (blue stick) is clearly below the detection limit for the secondary monochromator data.

No more Kß filter artefacts in your data! There is almost no greater nuisance in diffraction data than artefacts introduced by the Kß filter, specifically absorption edges at the high energy tails of Kα diffraction peaks. Nevertheless, Kß filters are the most frequently used devices for monochromatization, as secondary monochromators do not represent a true alternative due to the very high intensity losses discussed earlier. As a consequence, absorption edges frequently prevent accurate profile fitting of peak tail regions and the background, and thus often represent a major part of the remaining misfit to the data, specifically for high intense peaks at low angles 2θ. With the this is no longer the case. This is demonstrated in Figure 3 for the 104 reflection of corundum, NIST SRM 1976a, using Cu radiation. In the left scan window, a Ni-filtered diffraction pattern is compared to an unfiltered pattern, clearly exhibiting significant absorption edges, accompanied by remnant Kß peaks. In the right scan window, a " filtered" pattern is compared to the same unfiltered pattern. The data is completely free of absorption edges, furthermore Kß is filtered below the detection limit. In addition the total background is significantly reduced due to improved filtering of white radiation (Bremsstrahlung), resulting in improved peak to background ratios and thus lower limits of detection. Figure 3: Comparison of corundum data (NIST SRM 1976a) obtained with the detector. Black line: filter mode disabled. Blue line: filter mode disabled plus Ni-filter. Red line: filter mode enabled.

Highest durability The detector is radiationhard by design. Unlike other traditional detectors, including pixel detectors, the electronics are separated from the sensor and so are protected from radiation damage. Figure 4: Structure determination and refinement of LiFePO 4 using MoKa 1 data. Capillary transmission, d min = 0.4Å. As a consequence, the detector can be equally operated with all common characteristic X-ray emission lines, including, but not limited to Cr, Co, Cu, Mo, and Ag radiation. Detector degradation due to radiation damage is thus of no concern even for higher energies such as Mo and Ag radiation. Both excellent durability and superb energy resolution position the LYNXEYE XE-T as the Nr. 1 detector choice for applications benefitting from higher X-ray energies, most notably for structure determination and refinement as well as pair distribution function (PDF) analysis a shown in Figures 4-6. Figure 5: Comparison between Kß-filtered (black) and filtered LaB 6 (NIST SRM660a) data using Ag radiation demonstrating superb filtering of K-beta and white radiation also for applications requiring high-energy X-rays such as Mo and Ag. Capillary transmission. Figure 6: Structure refinement of strongly absorbing hematite using pair distribution function (PDF) analysis. Ag data, capillary transmission.

Quality by Design The detector is a paradigm changer in all X-ray powder diffraction application areas. It is not only unique in terms of functionality and versatility, but also in terms of manufacturing quality. Quality by design the detector is guaranteed to be free of defective channels or even dead areas at delivery time. This unique guarantee, together with a factory-made calibration, makes it particularly suited for one- and two dimensional fixed mode measurements. Reliable and complete data sets are obtained with the, without any missing data points and thus any need for data interpolation. No defective channels at delivery time Covered by instrument warranty Data acquisition without missing or interpolated data points Highly uniform active area, highest data quality Lowest background Data acquisition at low angles smaller than ~20 2θ requires some sophisticated beam conditioning to minimize instrument background (mostly air scatter), which otherwise is the most prominent contribution to the data. This is of particular concern at very low angles smaller than ~5 2θ, the small angle X-ray scattering (SAXS) regime, where background suppression is of highest importance. The unique Variable Active Detector Window feature of the virtually eliminates low angle background scattering. This is achieved by the fully automatic, software-controlled change of the active detector window size as a function of 2θ: At 0 2θ, the active detector window is closed, and gradually opens as the detector moves to higher angles 2θ, without any user-intervention. As a consequence, the use of beamstops becomes obsolete, and high quality data with virtually no instrument background can be collected starting at angles as low as 0.15 2θ as shown in Figures 7 and 8. Figure 7: NIST SRM 8486 (Ordinary Portland Clinker) without (blue scan) and with Motorized Anti-Scatter Screen (red scan). All other measurement conditions left identical. Figure 8: Low angle data collected on silver behenate. Thanks to the Motorized Anti-Scatter Screen and the Variable Active Detector Window of the the instrument background is extremely low.

Scanning two-dimensional diffraction Equipped with Bruker s patented 0 /90 mount, the can be used for 0D and 1D data collection (0 orientation), as well as 2D data collection (90 orientation). The principle is explained in Figure 9. Employing the detector for 2D diffraction applications allows one to take advantage of every single detector property also available for 0D- and 1D data collection, resulting in superior data quality not available with any other two-dimensional detector currently on the market: 1. Energy resolution Collection of 2D diffraction data at better than 380 ev energy resolution, taking advantage of the same filtering capabilities as for 0D and 1D data collection. Superb filtering of fluorescence and white radiation, best peak to background without the need for filters or monochromators. 2. Operation with all common characteristic X-ray emission lines In addition to commonly employed Cr, Co, and Cu radiation, 2D data collection is also explicitely supported for Mo and Ag radiation, thanks to the radiation hardness of the detector. 3. Highest data quality The absence of any defective channels or dead areas leads to the most uniform active detector area available on the market. The obtained diffraction data are not affected by any data interpolation. 4. Versatility Variable sample to detector distance to optimize 2θ- and g-coverage and peak resolution. 5. Software integration Full integration into the DIFFRAC.SUITE software package for both 2D data acquisition and evaluation, see Figures 10 to 12. Figure 9: Left - 0 orientation for 0D and 1D data collection, Right - 90 orientation for 2D data collection

Figure 10: 2D SAXS data collection with DIFFRAC.COMMANDER Figure 11: Figure 12: Real-time 2D and integrated 1D data view in DIFFRAC.COMMANDER during measurement Data integration in DIFFRAC.EVA

The highest performance detector for X-ray powder diffraction Technical data "Compound silicon strip" detector with 192 channels Up to 15 steps sub-sampling, giving 2880 (15x192) apparent channels Active window: 14.4 mm x 16 mm Spatial resolution (pitch): 75 micrometer Maximum global count rate: >100,000,000 cps (fast shaping time) Cr, Co, Cu, Mo, and Ag radiation Sensor thickness: 500 µm Radiation-hard front end electronics Proprietary charge-sharing elimination technology Energy resolution <380 ev at 8 kev (Cu radiation) at 298K (energy resolution invariably depends on environmental laboratory temperature) No maintenance No counting gas, cooling water or liquid nitrogen The LYNXEYE detector family is developed in collaboration with the AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, Krakow, Poland. LYNXEYE turned 90 : EP 1 647 840 A2 patent; EP 1 510 811 B1 patent Bruker AXS GmbH Karlsruhe Germany Phone +49 721 5 09 97-0 Fax +49 721 5 09 97-56 54 info.baxs@bruker.com www.bruker.com Bruker AXS is continually improving its products and reserves the right to change specifications without notice. Order No. DOC-H88-EXS073. 2016 Bruker AXS.