BVM Systems Limited. PQSensor MkIII Installation & Commissioning Manual - 1 -

Similar documents
2002-ALM USER MANUAL

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

670K9 SORtrax Level Transmitter

Power Quality. Case Study. Conrad Bottu Laborelec January 2008

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

IF30. User's manual. Description. Table of contents IF30

SINGLE-PHASE VSV SWITCH

Primary Metering. What is Primary Metering?

OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO

Status Date Prepared Reviewed Endorsed Approved

Collection of standards in electronic format (PDF) 1. Copyright

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)

DATA SHEET Selectable AC transducer TAS-311DG

Commissioning Manual Distribution Transformers - Three-phase Oil Filled

Current Probes. User Manual

INSTRUCTION MANUAL CLEVELAND-KIDDER TENSION INDICATOR SERIES AO REVISION

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

SINGLE-PHASE VSV SWITCH

PPS MFS series - Installation Guide. Power Protector Stabilizer V 3.8 1

4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Test description for dry-type transformers chapter for special tests

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

APS M1P Single-phase Micro-inverter Installation and User Manual

Control Cable installation: Best Practice

The Variable Threshold Neutral Isolator (VTNI)

Section L5: PRE-ENERGIZATION TEST PROCEDURES FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Magnetic Inductive Flow Sensor induq

Instruction Manual. TT1000 Tower Earth Tester. Rev 01

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

Model 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

INSTRUCTIONS YASKAWA. Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

Rosemount 5408 and 5408:SIS Level Transmitters

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Instrument Transformer Services (ITS) Voltage / Potential Transformer Reclassification

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

2620 Modular Measurement and Control System

Installation, Operation and Maintenance Manual

Back to the Basics Current Transformer (CT) Testing

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Stand Alone Rudder Angle Indicator System

I N S T R U C T I O N - M A N U A L RF-ADMITTANCE POINT LEVEL SWITCH

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Earthing, HV Switching and Associated Operational Equipment. Approval: Chief Operating Officer

N. TEST TEST DESCRIPTION

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

ET120 & ET60 Induction Loop Amplifiers

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

eddyncdt 3010 Non-Contact Displacement Measuring Systems

S&C Scada-Mate Switching Systems Outdoor Distribution Interrupter Replacement 14.4 kv through 34.5 kv

RF LEVEL TRANSMITTER. Series RFLT 900

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

N. TEST TEST DESCRIPTION

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Framing & Electrical Rough-in for Recess Mount IS Panel System

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

DC Current Transducers CT-200 CT-300 CT-400 User s Manual All Rights Reserved CAEN ELS d.o.o. Rev. 1.0 November 2014

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

GX 340 SERIES (AUTOMATIC VOLTAGE REGULATOR)

High Frequency Sinewave Guardian TM Filter

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I Pr I P I OUT R L. Applications. Standards

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

CDAX 605 High Precision Capacitance & Dissipation Factor Test Set

ALWAYS ATTACH THE SAFETY ROPE TO A STABLE SUPPORT BEFORE ATTEMPTING TO ATTACH THE UNIVERSAL MOUNT TO A WINDOW FRAME OR RAIL.

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

Simple-H User Manual

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

WEBS-MT/R Tower Installation Instructions

Model 4210-MMPC-W. Multi-measurement Prober Cable Kit. Overview

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

INSTRUCTION MANUAL (ATEX / IECEx)

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

VI 3 - i TABLE OF CONTENTS

For use in Flammable Gas and Dust Atmospheres

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SERVICING & METERING SERVICING AND METERING SECTION 5 SEC5:

Transcription:

BVM Systems BVM Systems Limited PQSensor MkIII Installation & Commissioning Manual Patents: 1295133, 6,919,717 BVM Systems LImited 21 Springvale Road Gilford Craigavon BT63 6EB United Kingdom Email: - 1 -

Important Safety Notice Aspects of the installation and commissioning of the PQSensor involve working on equipment where errors in installation or failure to follow appropriate safety procedures could result in exposure of personnel to Lethal High Voltages. Installation of the PQSensor should only be performed by personnel with the necessary knowledge and training. Pay particular attention to the safety aspects of those sections of the manual marked with the symbol. Ensure that the CVT input is solidly earthed at all times when any installation work is being carried out. Never open the CVT secondary terminal box unless the CVT is solidly earthed. Always ensure the bottom end of C 2 and the EMU are solidly earthed before energising the CVT. The output signal form the PQSensor is 63.5V. This can be present at any time that the PQ- Sensor is energised. - 2 -

GENERAL The purpose of a PQSensor is to equip a standard CVT with an interface that enables it to be used to make accurate measurements of harmonic levels and transients on h.v. power networks. CVT Secondary Terminal Box CVT Electromagnetic Unit Tank PQSensor Interconnecting Cable PQSensor PQSensor Signal Conditioning Module (SCM) PQSensor Mounting Plate CVT Support Structure PQSensor Supply and Output Signal Wiring PQSensor - Installation Figure 1 The PQSensor consists of three separate components The Measurement Unit (MU) The Signal Conditioning Module (SCM) The Interconnecting Cable An example of a PQSensor installation is shown in Figure 1. When installing the SCM box it is essential to ensure that it is positioned below the safety clearance height that will allow it to be worked on while the CVT is in service. The ideal mounting height is between 0.9 m and 1.5 m above ground level. - 3 -

The Measurement Unit The Measurement Unit consists of a 66 mm (w) x 65 mm (d) x 75 mm (h) box which contains the transducers that acquire the signals used to make the high accuracy broadband measurements. There are two sets of inputs, and together with their associated outputs. The Measurement Unit is also equipped with a test circuit that can be used for on site testing and calibration. The two sets of outputs are equipped with shorting jumpers and these should only be removed as and when required by the instructions contained in this document. Detailed dimensions of the Measurement Unit are given in Appendix I. It is equipped with three M3 mounting holes on the base. These holes are compatible with the Phoenix UTA98 DIN rail adapter and can also be used together with other custom made mounting plates. The Interconnecting Cable The Interconnecting Cable takes the signals from the Measurement Unit to the SCM. Both ends of this cable are provided pre-terminated and equipped with the appropriate glands for making off in the CVT secondary Terminal Box and the SCM Box. This steel wire armour (SWA) cable contains two individually screened twisted pairs together with a collective screen. The twisted pair conductors in this cable are stranded with 0.5 mm 2 nominal conductor area - usually a 16/0.2 conductor stranding. The SCM The SCM is designed to be mounted on the structure of the CVT as shown in Figure 1. Dimensions and mounting details for the box are provided in Appendix II. The OEM must provide a mounting plate or bracket on the CVT compatible with the holes shown in the drawing in Appendix II. The mounting plate is not included as part of the PQSensor as there many different types of CVT support structures. Factory Installation of the PQSensor Only the Measurement Unit is permanently installed in the CVT in the factory - the Interconnecting Cable and the SCM should be installed as part of the site installation and commissioning procedure. However the SCM must be connected to the CVT, usually using a dedicated cable installed in the factory test bay to permit the PQSensor to be calibrated when rated voltage is applied to the CVT. Measurement Unit Installation The Measurement Unit should be installed before the final factory CVT testing and calibration is performed. The Measurement Unit is installed in the secondary terminal box of the CVT and is usually fixed to an existing section of TS35 DIN rail using the Phoenix UTA 89 adapter provided. The three M3 mounting holes located in the base of the Measurement Unit can also be used with other custom mounting plates if required. The Measurement Unit has two inputs called the input and the input and these are wired in series with the capacitor and the EMU earth circuits respectively as illustrated in Figure 2. The input wiring is black and is clearly labelled. The earthed side of the input wiring is identified by green/yellow sleeving. The input wiring is grey and the earthed side of the input wiring is also identified by the green/yellow sleeving. Use the wiring schematic of the CVT to identify the connection points required to connect the input signals to the measurement unit. - 4 -

The and input circuits are low impedance circuits with guaranteed continuity that will not have any impact on the earth circuits of the Capacitor or EMU circuits of the CVT. These circuits are formed using a single piece of cable with no connections or joints. For additional security high current continuity tests are performed on these circuits as part of the factory test procedure and the results are contained in the Measurement Unit test report, a copy of which is included with the Measurement Unit. Main Terminal C 1 Electromagnetic Unit C 2 Installation of the Figure Measurement 2 Unit in the CVT After the Measurement Unit has been installed the terminations of the and input wiring must be carefully checked to ensure that they have been correctly and securely made and are physically robust as an incorrect or faulty connection will result in LETHAL VOLTAGES being present in the CVT secondary terminal box when the CVT is energised. If in any doubt about the installation or connection points for the MU inputs consult a qualified technical expert in your organisation. The shorting links that are fitted to the outputs of the Measurement Unit are removed to carry out the calibration of the SCM but they should be replaced after calibration has been completed and remain in place until the final site installation of the PQSensor. During the site installation the SCM will be connected to the CVT secondary terminal box by means of the SWA Interconnection Cable. This cable is fitted using a gland that requires a 20mm hole in the CVT secondary terminal box (either a threaded or clearance hole) and it may be more convenient to prepare this hole before the CVT leaves the factory than to do it on site. Factory Calibration of the PQSensor Measurement Unit - 5 -

To perform the calibration of the PQSensor it must be wired to the Measurement Unit installed in the CVT terminal box as shown in the wiring diagram in Appendix IV. The cable used for the connection of the and signals must be twin twisted pair cable with individual and collective screens as can be seen in the wiring diagram. The cable is terminated at the measurement unit as shown in Figure 3 and the connections in the SCM are shown in Figure 4. The cable used for the other connections is less critical and any twisted pair cable should suffice. For factory testing it is normal to install a dedicated Interconnection Cable between the CVT test bay and a location outside the high voltage test area - the length of this cable should be kept to a minimum, ideally less than 10m. Using this approach the PQSensor can be checked and calibrated while high voltage is applied to the CVT. Test armour collective screen individual screen Test 4 Black 3 2 1 Blue Black Blue Measurement Unit Armour earthed by cable gland The factory calibration of the PQSensor involves two steps Step 1 - Wiring and Installation Validation Figure 3 This first check is performed to verify the correct wiring of the Measurement Unit to the SCM and to validate the correct operation of the PQSensor. It involves injecting an ac current into the test inputs in the Measurement Unit and measuring the output voltage from the PQSensor on terminals 4 and 5. The level of test current to be injected is the Reference Test Current given in the factory test report and the output signal should be the Nominal Output Voltage - also included in the factory test report. A copy of the factory test report is enclosed with the each PQSensor. For other levels of input current the expected output voltage is given by the formula :- Output Voltage = Injected Test Current x Nominal Output Voltage Reference Test Current The measured output signal should be within 2% of the value given by the formula above. In the event that the error is larger than 2% then the wiring of the Measurement Unit should be carefully checked and the test repeated. - 6 -

Step 2 - PQSensor Calibration Having verified the output signal in step 1 then the test current should be removed and the PQ- Sensor is now ready to be calibrated. Calibration is normally performed at the same time as the calibration of the main CVT outputs. Rated primary voltage is applied to the CVT and the output of the PQSensor is adjusted using the output adjust control so that the output voltage is as given by the formula :- Output Voltage = Record the results on the calibration label inside the PQSensor. Also record the serial number of the CVT on the same label to ensure that at site the PQSensor is installed on the CVT with which it has been calibrated. Site Installation and Testing of the PQSensor Test Voltage x Nominal Output Voltage Nominal Rated Voltage Mounting The SCM Enclosure. The signal conditioning module (SCM) box is a weatherproof IP65 enclosure, with approximate dimensions of 260 mm x 160 mm x 90 mm. For full details of dimensions and mounting hole locations see Appendix II. The SCM box is typically installed on the CVT support structure in a vertical position with the cable entries on the bottom face. There must be a solid earth connection between the SCM enclosure and the earthed CVT structure, This is usually achieved by making a ground connection to the CVT structure using the earth tag provided as part of the interconnection cable gland kit. In hot climates it is also recommended to mount the SCM in a location that will afford the maximum shielding from direct sunlight. While the PQSensor is rated to temperatures up to 65 C, where possible, in warmer climates it is prudent to limit exposure direct sunlight. A canopy is provided for installations in climates where ambient temperature can exceed 40 C. Typical installation photographs can be seen in Appendix V. Output Adjust EARTH 16. Earth 15. Screen 14. (Black) 13. (Blue) 12. Screen 11. (Black) 10. (Blue) 9. Earth 8. Aux Cmn. 7. Aux 6. Earth 5. O/P Cmn. 4. O/P 3. Earth 2. Neutral / - 1. Live / + N.B. A mounting plate or bracket will be required to secure the SCM to the CVT structure. Since there is a wide variety of support structures used in substations this bracket is NOT provided with the PQSensor and will normally be sourced locally. Figure 4 Installing the Interconnecting Cable The Interconnecting cable is a total of 3m in length and is prepared at both ends for connection to the CVT secondary terminal box and the SCM enclosure. The interconnecting cable should - 7 -

be installed between the MU in the CVT secondary terminal box and the SCM using the glands supplied. First terminate the connections in the SCM as shown in Figure 4 and the drawing in Appendix IV. Then remove the links on the MU outputs and terminate the other end of the cable as shown in Figure 3. The interconnecting cable should be securely fixed to the CVT structure at as many points as necessary to ensure there are no loose sections of cable. Supply voltage and Output Signal connection In addition to the connections to the Measurement Unit the supply voltage and the output signal need to be connected. These connections should be made using stranded cable with a minimum size of 1mm 2. The PQSensor accepts a universal supply and can be powered from 110V ac, 230V ac or 110-250V dc. An Earth connection must always be made to pin 3 of the PQSensor user connections terminal block. The nominal output signal from the PQSensor is 63.5V ac so appropriate safety precautions should be taken when working with a voltage of this level. For safety purposes it should be assumed that when the PQSensor is powered on there is always a voltage of 63.5V ac present on the output terminals. The PQSensor is intended to be used with equipment that has an input impedance of greater than 1Mohm. Site Verification For a Factory Calibrated PQSensor It is recommended to repeat the Wiring and Installation validation check as performed in the factory to ensure that field installation has been completed correctly. This involves injecting the Reference Test Current into the test inputs of the MU and verifying that the output of the PQ- Sensor is within 2% of the Nominal Output Voltage. Since the PQSensor has been factory calibrated it only remains to verify that the output of the PQSensor is consistent with the primary voltage when the CVT is energised. To verify the PQSensor output monitor the substation voltage using the most accurate instrument transformer available (e.g. a reference substation CVT or inductive VT) and using a calibrated True RMS meter measure the output of the PQSensor. Using the formula :- Output Voltage = Measured Substation Voltage x Nominal Output Voltage Nominal CVT Voltage the measured output voltage should be within 0.5% of the Output Voltage given by the formula. When testing is complete record the substation voltage and output voltage on the label provided inside the PQSensor. Site Calibration Of a PQSensor being fitted to an existing installed CVT As a first step install the Measurement Unit and the SCM as described above. Before energising the CVT to perform the site calibration it is recommended to re-check the Wiring and Installation Validation as described above.to perform this calibration check the complete PQ- Sensor should be installed as described above and the CVT secondary terminal box securely - 8 -

closed up before the CVT is energised. N.B. Before energising the CVT ensure that the earth connections in the C 2 and EMU circuits have been securely established and checked as part of the Measurement Unit installation. Also ensure that the CVT secondary terminal box is securely closed. Using an accurately calibrated voltmeter measure the output voltage of the SCM while the CVT is energised. The measured output voltage should be exactly 63.5 V rms for nominal substation voltage. Use the formula below to determine the expected output voltage for substation voltages that differ slightly from the nominal voltage. Output Voltage = Measured Substation Voltage x Nominal Output Voltage Nominal CVT Voltage Minor adjustments to the calibration of the PQSensor can be made by adjusting the gain adjust in the SCM which is accessible through the top panel. If the error between the measured voltage and the expected voltage is greater than 5% then it is likely that there is an installation problem and the CVT should be de-energized, made safe and the PQSensor installation and wiring should be checked. When testing is complete record the substation voltage and output voltage on the label provided inside the PQSensor. - 9 -

Appendix I 89.0 67.0 52.0 Recommended DIN rail mounting using Phoenix UTA 89 Universal DIN Rail Adapter Primary Inputs front view 78.0 bottom view 64.0 9.0 9.0 33.0 66.0 46.0 62.0 side view Primary Inputs 64.0 Measurement unit mounting is by 3 x M4 blind inserts Date :- 24 Nov 2009 App :- - Dwn :- JM Rev :- 01 Details :- Title:- PQS Consulting Measurement Unit (with test circuit) Dimensions Dwg No.:- 22-0028 Page of 1 1-10 -

Appendix II SCM Dimensions Mounting Holes 110 mm centres Overall width 160 mm depth 92 mm BVM Systems 16. Earth BVM Systems Limited Patent Nos:- 1,295,133 and 6,919,717 PQSensor Mounting Holes 240 mm centres Overall height 260 mm Fixing bolts - M6 x 30mm - 11 -

Appendix III PQSensor - Sample Test Reports Measurement Unit Test Report Date:- August 6, 2010 Customer:- CVT OEM Serial Number:- 1007-0209 Input Continuity Check Test Current (A) 7.89 Resistance (mohm) 23.18 Result Pass Hi-Pot Test (2.5 kv ac) I/P - O/P (ma) 0.11 I/P - Gnd (ma) 0.08 O/P - Gnd (ma) 0.06 Result Pass MU Ratio And Phasing Check Ratio Test Error < 0.25% Ratio Test Error < 0.25% & Phasing Pass Result Pass Signed - 12 -

PQSensor Test Report Date:- June 9, 1946 Customer:- CVT OEM SCM Serial Number:- 1007-0089 Injection Measurement Error ( less than) 0.00% Result Pass Injection Measurement Error ( less than) 0.0% Result Pass Test Injection Measurement Error ( less than) 0.0% Result Pass Frequency Response Result (see attached graph) Pass Signed Reference Data Voltage (kv) 132 C1 (pf) 15500 C2 (pf) 66500 TH 250 TL 125 Nominal Output Voltage 63.5 Reference Test Current (ma) 856.594 Page 1 of 2-13 -

SCM Serial Number - 1007-0089 0.70% Frequency Response Report 0.65% Output - for 0.5% input level 0.60% 0.55% 0.50% 0.45% 0.40% Frequency 0.35% 0.30% 5 9 19 29 39 49 59 69 79 89 99 Harmonic Order Page 2 of 2-14 -

Appendix IV PQSensor Wiring Diagram TEST White TEST White Black Red Black Red Measurement Unit White Black Blue Black Blue armour collective screen individual screen Armour earthed by cable gland Cable is SWA with two 0.5mm 2 twisted pairs, individually screened with collective screen (Anixter - A7-P52-0002LF) Note:- Cable pairs are marked '1' and '2' on the internal screen insulation tape. Pair '1' is used for and '2' for EARTH SCN Black Blue SCN Black Blue Armour earthed by cable gland Output common Output (63.5V ac) Earth 230V ac live (or +100-250V dc) 230V ac neutral (or -100-250V dc) Date :- App :- - Dwn :- Rev :- Details :- PQSensor TB 1 16 15 14 13 12 11 10 5 4 3 2 1 17 Mar 2010 JM 01 Title:- PQS Consulting Measurement Unit Wiring Dwg No.:- 17-0151 Page of 1 1-15 -

Appendix V PQSensor Marshalling Box Wiring Diagram PQSensor SCM Phase A Output Common Output Earth Neutral (-ve) Live (+ve) PQSensor SCM Phase B Output Common Output Earth Neutral (-ve) Live (+ve) PQSensor SCM Phase C Output Common Output Earth Neutral (-ve) Live (+ve) Signals to remote Recording Device 110/240V ac (l) or + 110/250V dc 110/240V ac (n) or - 110/250V dc Earth CVT Marshalling Box Phase A Output Phase B Output Phase C Output Common Date :- App :- - Dwn :- Rev :- Details :- 27 May 2010 JM 01 Title:- PQSensor Marshalling Box Wiring Dwg No.:- 17-0154 Page of 1 1-16 -

Appendix VI PQSensor Installation Examples - 17 -