Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Similar documents
Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

RA / /6. Replaces: Table of contents RA /06.98

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

RT-5005/5006/5007/5008

Electric amplifier for flow control with proportional

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

Valve amplifier for proportional pressure valves

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Valve amplifier for proportional valves with electrical position feedback

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

MDSD (Series 2X) Mobile Dual Solenoid Driver

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

Electric amplifiers. Table of contents. Features RA 30052/ Model VT-VRPA1. Series 1X 1/6

Valve amplifier for proportional pressure valves

Analog amplifier RA. RE Edition: Replaces:

Electric amplifier for proportional cartridge throttle valves

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

p/q closed-loop control amplifier

Electric amplifiers. List of contents. Features. RE 30052/08.05 Replaces: Type VT-VRPA1. Unit series 1X 1/6

Electro-Hydraulic 4-Way Directional Servo Valve Model 4 WS 2 E.10 and 4 WSE 2 E. 10 (Series 4X) PSI (315 bar) K K

Booster amplifier. Table of contents. Features. RE 30260/04.12 Replaces: Type VT-MSFA1. Component series 1X 1/6

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

Drive Electronics pq11

Drive electronics pq11

Operating Instruction

Generator Speed Controller Model GSC 1

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

DENISON HYDRAULICS Proportional Pressure Control Valves

Digital Interface Card DEC005000

Accessories Power Amplifiers

4/3 proportional directional valve direct operated, with integrated electronics

Proportional amplifier type EV22K5

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

Mobile dual solenoid driver

Technical Documentation

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

Electronic amplifier type EV1D

EMA Series, EMC Series

Controller. 1 Proportional amplifier module ESSK 103. ESSK 103 and ELSK Description. 1.2 Application examples. 1.

Sealed Interface Control: EC20300

ELECTRONIC REGULATOR FOR OPEN LOOP

Digital amplifier for proportional valves PEM XD

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

Analogue amplifier modules for 4/3 and 4/2 proportional directional valves 4WRE

Electronic regulator for PWM controlled proportional solenoid valves FABER -

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Continental Hydraulics Installation Manual CEM-RA-A

DIN (NFPA/ISO/CETOP) NG6 (3) NG10

Coils & Electronic Controls

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

TABLE OF CONTENTS LIST OF FIGURES

Proportional amplifier type EV1M3

Proportional Directional Control Valves Nominal sizes 16 and 25

Protection relays and controllers. Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

TECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging

Potentiometer Control EC20200

Programmable with Electronic Assistant Simulink

1. General Instructions 2 2. Safety 2 3. Lamp Starting Test Instrument LSTI 5 3

Operating Instructions

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Electronic plugs for valves MSE

Proportional amplifier type EV1M3

Proportional Directional Control Valves Size 6

4/3-way fast response valve Type 4WRGE

Continental Hydraulics Installation Manual CEM-PA-A

Adjustable Digital Process Instrument MDK480

on-board EEPROM, are incorporated for automatic zero point and full-scale alignment.

YVPC ELECTRONIC REGULATOR FOR PWM CONTROLLED SOLENOID

For non-electrical quantities

LoopBack Relay. LB363 Series. With Built-in AC Bypass Capacitors. LoopBack Relay, Sensitive Coil, thru-hole with AC Bypass Capacitors

Franck-Hertz Control Unit

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

audionet amp II G2 Owner's Manual Mono - Amplifier

MCHXXX. Simple to install MECHANICAL. HANDLE STROKE ± 30 (60 total travel)

S D 1 Operating Instructions

LoopBack Relay. GLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

Vickers. Servo Valves. Servo Electronics. Amplifiers, Power Supplies, Function Modules, and Controllers. Rev. 11/97

General Specifications

Catalog Hydraulics meets Electronics.

Box chopper amplifier BOE

Ordering Part Numbers: SAE J1939 version Controller: AX022400

High Voltage Power Supplies HCE - Series

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Transcription:

Electronic amplifier for the control of proportional valves without position control Model T 3006, Series 3X RA 29 926/06.98 Replaces: 02.96 The amplifier T 3006-3X is suitable for the control of pilot operated proportional directional valves (WRZ, Series 6X and older) and direct operated pressure valves (DBEP6, 3DREP6, Series 1X) without position feedback. Characteristics: our command values adjustable with potentiometers our command value call-ups with LED display Differential input Step function generator Ramp generator with five ramp times Two pulsed current output stages Polarity protection for the voltage supply H/A 4240/94 Note: When supplied the amplifiers have a ramp time of 5 s. (Setting of the ramp time of 1 s see page 5) T 3006-3X Card Holder: CH32C-1X, see RA 29 921 T 3002-2X/32, see RA 29 928 Output curve Solenoid A 800 Solenoid B Output current in ma 600 400 200 0 100 50 1 +1 +50 +100 Command value in % 1/6

Technical data (or application outside these parameters please consult us!) Operating voltage 1 ) DC 24 DC; + 60 %; 5 % unction range upper limit value (momentary value) DC (t) max 39 lower limit value (momentary value) DC (t) min 22 Power consumption I < 1 A (with loading current) use I S 2.5 A time lag, M5 x 20 Inputs Command values 1 to 4 e ± 9 (reference potential is M0) Command value 5 e ± 6 (reference potential is M0) Command value input 6 (Differential input) e 0 to ±10 ; R e = 100 kω Relay data Nominal voltage Operating voltage DC Threshold voltage 16.8 Return voltage 2.4 Coil resistance R 2150 Ω Ramp time (setting range) t 30 ms to ca. 1 s or 5 s Controlled voltage ± 9 ± 1 %; 50 ma. externally loadable Solenoid current I max 800 ma; R (20) = 19.5 Ω Pilot current I 20 ma ± 25 % Pulse frequency of output stages f 10 Hz ± 10 % Test points Command value w ± 6 ; R i = 5 kω Actual current value I A, I B A, B 0 to 800 m 0 to 800 ma Type of connection 32-pin terminal strip, DIN 41 612, type D Card dimensions Euro-card 100 x 160 mm, DIN 41 494 ront plate dimensions Height 3 U, 5.06 in (128.4 mm) Width soldering side 1 HP, 0.20 in (5.08 mm) = 1 division Width component side HP = divisions Permissible operating temperature t +32 +122 (0 50 C) to DIN/IEC 68-2, T1, T2, T14 and T30 2 ) Storage temperature range t 13 +185 ( 25 85 C) 2 ) Disturbance resistance Class 3 to DIN/DE 843 T2 and T4 2 ) Mechanical loadability to DIN/IEC 68-2, T6, T24 and T2 2 ) Weight m 0.33 lbs (0.15 kg) 1 ) To guarantee the maximum solenoid current for the 19.5 Ω solenoid in the highest solenoid temperature range the operating voltage must be at least 28 DC! 2 ) or further details, please consult us! 2/6

3/6 Positive command value controls solenoid "B" Negative command value controls Solenoid "A" Command value 5 ± 6 Command value 4 ± 9 Command value 3 ± 9 Command value 2 ± 9 Command value 1 ± 9 Differential input Command value 2 ± 10 Reference potential/ GND Command value after ramp Measuring zero (M0) is raised by 9 compared to 0 operating voltage! ± 9 Aux. voltage Call-up command value 1 Call-up command value 2 Call-up command value 3 Call-up command value 4 Call-up "Ramp Off" Call-up "switch-over aux. voltage" Relay call-up voltage (+ 24 ) + 9 M0 9 X1 14c 14a 12c 12a 8a 10a 10c R1 16a 16c 18a 2a 20c 20a 26c 8c 4a 6a 6c 18c 4c 28c K1 R2 1 K1 R3 K2 t5 K3 2 K2 R4 1 K4.2 K3.2 K2.2 K1.2 t4 t3 t2 t1 K4 K3 K6 + K4 H1 to H4 = LED-display for command value call-ups K1 to K6 = Call-up relay R1 to R4 = Command values 3 K5 K6 K5 4 J5, J6 H1 H2 H3 H4 Current command value at "w" 0 to + 6 for solenoid "A" 0 to 6 for solenoid "B" Current / A at "I A " Current / B at "I B " 5 8 = 6 w 2.5 A MT R = Pilot current solenoid "A" R8 = Pilot current solenoid "B" t1 to t5 = Ramp times m ma (0 to 00 m) -1 I A 2200 µ R R8 I B = on front plate 1 Command values 2 Differential input 3; 6 Summation 4 Ramp generator I I X1 30a 24a 22a 28a 32c 32a + DC Solenoid "A" Solenoid "B" 0 Operating voltage 5 Step function Current amplifier with pulse generator 8 Power supply Block circuit diagram / terminal connection T 3006 3X

unction description With the command value inputs 1 to 4 command values can be called up [1] by operating the corresponding relays (K1 to K4). The command value voltage is either given directly through the controlled voltages ±9 of the power supply [8] or via an external command value potentiometer. or these inputs ± 9 is ± 100% 1 ). If these four command value inputs are directly connected to the controlled voltages ±9, four different command values can be set at the potentiometers R1 to R4. When using external command value potentiometers at these inputs the internal potentiometers also function as limiters when these are not set to maximum. Clockwise increases the command value. External command value potentiometer 5 K 5 K 5 K 10c (10a, 8a, 12a) inputs 20c 20a 26c 20a 20c 26c + 9 M0 10c (10a, 8a, 12a) inputs 9 M0 10c (10a, 8a, 12a) inputs + 9 9 Control "Solenoid B" Control "Solenoid A" Control "Solenoids A + B" Which command value is called up is indicated by the LEDs H1 to H4. If more than one command value is called up simultaneously, the input with the highest number has priority. Example: If command value 1 and command value 3 are activated simultaneously, the command value 3 becomes effective. An auxiliary output on the card provides a supply voltage for the command value call-ups which can be switched over from +9 to 9 with the relay K6 1 ). Each one of the four command call-up values has an adjustable ramp time allocated (t1 to t4). If no command value is called up the ramp time t5 becomes effective. Clockwise increases ramp time. All relays on the card are switched with 24 DC (smoothed). Additionally, the direct command value input 5 is available for the input voltage 0 to ±6. alid is ± 6 =±100 % 1 ). The command value input 6 is a differential input (0 to ± 10 ) 2 ). When using external electronics, this differential input must be used. When switching on or off the command value, both signal lines should be separated from or connected to the input. All command values are summed with the correct value and sign before they are connected further.[3]. The added ramp generator [4] produces a ramp-like output signal from the jump-like given input signal. The time constant can be set with the potentiometers "t1" to "t5". The ramp time given refers to a command value jump of 100% and can be - according to the setting through the selection via jumpers - approximately 1 s or 5 s. If a command value jump smaller than 100% is switched to the input of the ramp generator the ramp time shortens appropriately. External time potentiometer and ramp "O" 500 K 14a 14c 14a 14c Ramp controllable time: min. = 0 time: min. = 500 k Ramp On/Off Note: When using an external time potentiometer the internal potentiometer for the ramp time must be set at maximum. The maximum ramp time decreases because the resistance of the external potentiometer is connected parallel to the internal potentiometer! By switching the relay K5 or through an external bridge the ramp time is set to its minimum value (approx. 30 ms). The output signal of the ramp generator [4]runs parallel to the summator [6] and the step function generator [5]. The step function generator produces a polarity-dependent constant step signal with the command value voltages which is added to the output signal of the ramp generator. This step function causes the rapid travelling across the overlapping area of the valve. The output signal of the summation [6] is the command current value and is led to the two current output stages [] and to the test point "w" on the front plate of the card. A voltage of 6 at the command value test point corresponds to a command value of 100%. A positive command value signal at the input of the amplifier controls the output stage for solenoid B, a negative command value signal the output stage for solenoid A. If the command value signal is smaller than ±1% (step function still ineffective) a pilot current of 20mA flows through both solenoids. The actual values of the currents through the two solenoids can be measured separately at the test points I A (solenoid A) and I B (solenoid B). Here a current of 800 ma corresponds to a voltage of 800 m. 1 ) = Reference potential for the command values 1 to 5 is M0 (measuring zero). 2 ) = Reference potential for the differential input should be grounded to 0 at source end. [ ] = Allocation in block circuit diagram 4/6

Display / setting elements T 3006 3X Plug-in board with potentiometers t1 to t5 Max. ramp time approx.1 s or 5 s H11 - yellow LED display "power on" H12 - green LED display "no fault" R1 / H1 - Command value 1 with LED display R2 / H2 - Command value 2 with LED display R3 / H3 - Command value 3 with LED display R4 / H4 - Command value 4 with LED display w - Command value solenoid current I B - Actual current value solenoid B I A - Actual current value solenoid A R1 R2 R3 R4 t1 t2 t3 t4 t5 J6 J5 1 2.5 A MT X1 Meaning of the jumpers on the card for the settings (Label on the back of the frontplate) ramp time Jx = bridge bridge plugged in 5 s J5 J6 Jx = open bridge open 1 s J5 J6 = delivery state delivery condition Ramp time Note: The loss of unused jumpers can be avoided by plugging the jumpers into only one pin. Project / maintenance instructions / additional information The amplifier card may only be plugged in or unplugged when power is off! Do not use plugs with fly back diodes or LED displays when connecting the solenoids! Only carry out measurements on the cards with instruments R i > 100 kω! Measuring zero (M0) is raised by + 9 compared to 0 operating voltage and is not potentially separated, i.e. 9 controlled voltage 0 operating voltage. Therefore do not connect measuring zero (M0) to 0 operating voltage! When switching command values use relays with gold contacts (small voltages, small currents)! When switching card relays only use contacts with a loadability of approx. 40, 50 ma! When controlling externally the control voltage may have a maximum residual ripple of 10%! Always shield command value lines; connect screen to 0 operating voltage on the card side, other side remains open (danger of earth loops)! Recommendation: Also shield solenoid lines! Use cable type stranded 16 AWG ( LiYCY 1.5 mm 2 ) for solenoid lines of up to 50 m in length. Minimum distance to aerial lines, radio sources and radar equipment must be at least 1 m! Do not lay solenoid and signal lines near power lines! Because of loading current for the smoothing capacitor on the card, fuse should be time lag! Warning: When using the differential input, both inputs must always be switched on or off simultaneously! (Use DPDT dry contacts) When using the differential input, an isolated analog common should be grounded to 0 from the card s power source, at one point on the source end. 5/6

Ordering code T 3006 3X/ * Amplifier for proportional valves without position control Series 30 to 39 (Series 30 to 39: technical data and terminal connections unchanged) = 3X urther details in clear text Unit dimensions: dimensions in inches (millimeters) 3U 5.06 (128.4) H11 H12 R1 H1 R2 H2 R3 H3 R4 H4 w I B I A t1 t2 t3 t4 t5 3.94 (100) 3.50 (89) 0.59 (15) T 3006 8HP 1.59 (40.3) 0.28 () 6.50 (165).32 (186) 0.08 (2) 0.28 () 6/6 Mannesmann Rexroth Corporation Rexroth Hydraulics Div., Industrial, 2315 City Line Road, Bethlehem, PA 1801-2131 Tel. (610) 694-8300 ax: (610) 694-846 Rexroth Hydraulics Div., Mobile, 100 Old Mansfield Road, Wooster, OH 44691-0394 Tel. (330) 263-3400 ax: (330) 263-3333 All rights reserved Subject to revision Printed in U.S.A.