GSV-1H 010/250/2. Highlights

Similar documents
GSV-2MSD-DI IP43. Highlights

K3D60a ±100N. Description. The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes.

K3R110 ±50N; ±100N, ±200N; ±500N, ±1000N, ±2000N; ±5000N

8-Channel measuring amplifier GSV-8

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS

8-Channel Measuring Amplifier BX8

Strain Gauge Measuring Amplifier BA 662

Strain Gage Bridge Amplifier GSV-2

SGIM Strain Gauge Input Module. user manual

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

LJTick-InAmp August 7, 2007 Revision 1.07

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

DMS Insert Module MSR 282

12/4/ X3 Bridge Amplifier. Resistive bridge amplifier with integrated excitation and power conditioning. Logos Electromechanical

Measurement range. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( )

Model A. DIN Rail Strain Gage Conditioner. Installation and Operating Manual

DRG-SC Series Signal Conditioners

Force and strain sensors. Measure. Test. Control. Edition 2016

Box chopper amplifier BOE

BX8 Operating Manual

SCXI 8-Channel Isolated Analog Input Modules

CSG110 Strain Gauge Universal Amplifier

Instrumentation Amplifier Module. Instruction Manual

RENATO DESIRÒ PARABIAGO (MI) Via Sant Anna, 51 Tel Fax

Transducer for Measurement Bridges SCM90, SIGS15

HAEHNE. Digital Strain Gauge Amplifier DMA2. Adjustment Instructions. Content

MAGTROL. LMU Series Load Monitoring Units. LMU Data Sheet. Description. Features

7I33/7I33T MANUAL Quad analog servo amp interface

m/min Digital panel meter with 4½-digit PV4, PT4, PF4, PW4 galvanically insulated 8 free scalable setpoints/hysteresis optical setpoint indication

on-board EEPROM, are incorporated for automatic zero point and full-scale alignment.

Strain gauge amplifier

Tel: (949) Fax: (949) IAA100 Product Manual

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Emant Pte Ltd BRIDGE SENSOR APPLICATION ADAPTOR FOR EMANT300, EMANT380

Multichannel amplifier Model 9235/36

TRANSDUCER INTERFACE APPLICATIONS

SEIKA SB2i-B. SB2i-B1 /B2 & B3 DC Acceleration. 4-20mA DC Acceleration

Analog Vs. Digital Weighing Systems

Load Cell Accessories and Services

Series GLET Accessory for dataloggers series GL in modular enclosure

SEIKA SBG3i. SBG3i-B1/B2 & NB3 Acceleration

Vibrating Wire Instrumentation

Bridge Measurement Systems

Embedded Strain Gauge and Load Cell Signal Conditioner/Amplifier v.2.3

MEP 382: Design of Applied Measurement Systems Lecture 5: Signal Conditioning

SEIKA SB2i-NB3 or N2,N3,N4

Technical Manual TRANSDUCER AMPLIFIER TYPE DR7AC. Doc. Ref CD2402K

Precision amplifier for bridge circuits AM467 PRINCIPLE FUNCTION

Measuring Modules for SCP Slim Charge amplifier without sensor identification Type 5064B11 Charge amplifier with sensor identification Type 5064B12 Pi

VXI-TB CHANNEL ISOTHERMAL TERMINAL BLOCK

GENERAL OPERATING INFORMATION

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

Protection class IP67/IP69K Magnetic measurement principle

VISTEK V1638 ANALOGUE AMPLIFIER USER GUIDE.

Stereo Clipper 15KHz LPF. Stereo audio clipper with active 15KHz filters

MODEL AT-10 ANALOG TRANSMITTER

Experiments #6. Differential Amplifier

7I33 / 7I33TA MANUAL Quad analog servo amp interface

ICA1 & ICA2 S and H Versions Strain Gauge or Load Cell Embedded Analogue Amplifier

ICA4 S and H Versions Strain Gauge or Load Cell Embedded Analogue Amplifier. User Manual

Lab 4 - Operational Amplifiers 1 Gain ReadMeFirst

ENGR-4300 Electronic Instrumentation Quiz 3 Fall 2010 Name Section

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

MODEL 25D MANUAL PRODUCT OVERVIEW:

SC-4/M User manual 4-channel measuring amplifier

SCP for Combustion Engines

Note The module converts unipolar and bipolar input signals

Datasheet. Inductive Power Supply System (IPSS) Datasheet IPSS

SEIKA SB2i-B. SB2i B1/B2/B3 & NB3 DC Acceleration. 4-20mA 2 wire output DC Acceleration

INSTALLATION & OPERATION MANUAL

AN-177 HI-8190/HI-8191/HI-8192 Analog Switch Application Note

ICA5 S and A Versions Strain Gauge or Load Cell Embedded Analogue Amplifier

Q181RC Ribbon Controller

Series APD4059. For Load Cells/Pressure Transducer Transmitters. Field Rangeable, with Calibration Resistor. Standard Features.

ICA3 & ICA6 S and H Versions Strain Gauge or Load Cell Embedded Analogue Amplifier

Protection class IP67/IP69K Magnetic measurement principle

ICA H & S Strain Gauge or Load Cell Embedded Analogue Amplifiers

Telemetrie-Messtechnik Schnorrenberg

Project 7: Seismic Sensor Amplifier and Geophone damping

Characteristics and functioning

Model 25A Manual. Introduction:

SCP SUNSTAR传感与控制 for Combustion Engines Signal Conditioning System, with optional PiezoSmart, TEL: Modules for

ICA User Manual ICA. ICA Embedded Strain Gauge Analogue Amplifiers

Signal Conditioning Systems

Hardware Adjustment 13 Trimpots 13 CAL/NORM, CAL1/RUN, and CAL2/RUN Switches 13

Torque Sensor. Torque. with Dual-Range-Option. Type 4503A...

Torque Sensor. Torque. Dual-Range Sensor with Brushless Transmission. Type 4503A...

Electronics and Instrumentation Name ENGR-4220 Fall 1999 Section Modeling the Cantilever Beam Supplemental Info for Project 1.

Lab 2.4 Arduinos, Resistors, and Circuits

611 Strain gauge transducer amplifier ELECTRONICS

Model 140 Inline Amplifier

MAGTROL. LMU 116 Load Monitoring Unit. LMU 116 Data Sheet FEATURES DESCRIPTION SYSTEM CONFIGURATION

Simple LFO Features. 2. Application. 3. Description. Simple and easy to build LFO module for Analog Synthesizers.

SENSOTEC, INC Arlingate Lane Columbus, Ohio Phone (614) Facsimile (614) Toll Free Free (800)

Inverting_Amplifier -- Overview

PCM - Sensor Telemetry for Turbo Prop/Jet Application

MX1615. Data sheet. Bridge/strain gauge amplifier

Analogowy przetwornik wzmacniający dedykowany dla czujników tensometrycznych RQA INSTALLATION MANUAL. Rev. 0.2

Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1

Transcription:

GSV-1H 010/250/2 Highlights Taring function via control cable 250Hz filter in the standard design 2.5 khz or 10 khz filter optional Amplification configurable ±10V output signal optional 4...20mA output signal Supply from up to 8 full bridges at 350 ohm Connection of half and full bridges as an option Stand 19 Mar 2019 Measuring amplifier GSV-1H 010/250/2 1/8

Description The measuring amplifier GSV-1H is available with voltage outputs ±10V and current output 4...20mA. The current output can be factory configured for automatic zero adjustment to 4 ma (4 ma + 16mA, for "unipolar" measurements), or for an automatic zero adjustment to 12 ma (12 ma + -8 ma, for "bipolar" measurements). Due to the high filter frequency of 250 Hz (2.5 khz and 10 khz optional), it is also perfectly suitable for dynamic measurements. The force sensor is connected to terminals 1 to 4. The voltage supply (11-28 volt) is connected to terminal 5 and 8 (ground). To set to zero, terminal 6 is connected to the voltage supply or a control signal between 5 volt and 24 volt is applied. The status is permanently stored in an EEPROM. Amplification can be switched 1-2-4-10 times via internal jumpers. If the input signal becomes negative, output follows up to 0 ma. Stand 19 Mar 2019 Measuring amplifier GSV-1H 010/250/2 2/8

Dimensions Stand 19 Mar 2019 Measuring amplifier GSV-1H 010/250/2 3/8

Technical Data Input analog Input sensitivity-steps 0.2 0.5 1.0 2.0 mv/v Input resistance strain-gauge-full-bridge 43... 5000 Ohm Output analog Number of analog outputs 1 Voltage output f -10... 10 V Output resistance - voltage 47 Ohm Measuring frequency Limit frequency (analog) 250 Hz Supply Supply voltage f 11... 29 V Strain gauge bridge supply 5 V Interface Type of the interface Analog Zero adjustment Tolerance 0.1 %FS Time period 250 ms Debouncing time 4 ms Trigger level f 3.5... 30 v Trigger edge falling Temperature Rated temperature range f -10... 65 C Operating temperature range f -40... 85 C Environmental protection IP40 Basis Data Housing Connection Number of channels top-hat rail screw terminal 1-Kanal Precision Accuracy class 0,1% Relative linearity error 0.02 %FS Temperature effect on the zero point 0.1 %FS/10 C Temperature effect on the measuring sensitivity 0.05 %RD/10 C Stand 19 Mar 2019 Measuring amplifier GSV-1H 010/250/2 4/8

Pin Configuration Symbol Description +Us positive bridge power supply 1 -Us negative bridge power supply 2 +Ud positive differential input 3 -Ud negative differential input 4 +Ub DC voltage supply 5 Tara Control input zero adjustment 6 UA Analogue output 7 GND Earth 8 Comment: The earth of the supply voltage AND the earth of the analogue output are connected to terminal 8. Terminal 8 is doubly allocated. PIN Stand 19 Mar 2019 Measuring amplifier GSV-1H 010/250/2 5/8

Mounting Adjustment of the input sensitivity The input sensitivity can be adjusted by moving the jumper. The input sensitivity for position 1 is indicated in the type designation. In position 5, the amplification can be set in a continuously variable manner using trimmer TR. Position Amplification factor Input sensitivity in mv/v Input sensitivity in mv/v Input sensitivity in mv/v for GSV-1H with 2 mv/v for GSV-1H with 3.5 mv/v for GSV-1H with 10 mv/v 1 1 2 3.5 10 2 2 1 1.75 5 3 4 0,5 0.85 3.3 4 10 0,2 0.35 2.5 5 1...10 2...0.2 3.5... 0.35 10... 2.5 For an amplification factor 1, the complete output signal is reached for a modulation of 100%. For an amplification factor 2, the complete output signal is already reached for a modulation of 50%. Connection of half bridge strain gauges In a special version GSV-1H with the /HB option, an internal bridge supplement is available with resistors R1 and R2: Stand 19 Mar 2019 Measuring amplifier GSV-1H 010/250/2 6/8

The external active resistors R3 and R4 are connected to +Us ( PIN 1) +Ud ( PIN 3) +US ( PIN 2 Connection of quarter bridge strain gauges In a special version GSV-1H with the /QB option, an internal bridge supplement is available with resistors R1, R2 and R4: The active resistor is R3 The Aux connection is at PIN 1 in this version. Stand 19 Mar 2019 Measuring amplifier GSV-1H 010/250/2 7/8

Orderoptions Type GSV-1H 010/250/2 GSV-1H 4-20/250/2 GSV-1H 010/2k5/2 GSV-1H 4-20/2k5/2 GSV-1H 010/250/3.5 GSV-1H 4-20/250/3.5 GSV-1H ±10/250/2 GSV-1H ±10/250/3.5 GSV-1H 010/250/2/QB350 GSV-1H 010/250/10 GSV-1H 4-20/20/2 GSV-1H 010/10khz/2 Description Output -10...10 V, 250 Hz, input ±2 mv/v (standard type) Output 4...20 ma, 250 Hz, input ±2 mv/v (standard type) Output -10...+10 V, 2.5 khz, input ±2 mv/v Output 4...20 ma, 2.5 khz, input ±2 mv/v (standard type) Output -10...+10 V, 250 Hz, input ±3.5 mv/v Output 4...20 ma, 250 Hz, input ±3.5 mv/v Output -10...+10 V, 250 Hz, input ±4 mv/v Output -10...+10 V, 250 Hz, input ±7 mv/v Output -10...10 V, 250 Hz, input ±2 mv/v bridge completition for 350 ohm quarter bridge Output -10...+10 V, 250 Hz, input ±10 mv/v Output -10...+10 V, 20 Hz, input ±2 mv/v Output -10...+10 V, 10 khz, input ±2 mv/v Stand 19 Mar 2019 Measuring amplifier GSV-1H 010/250/2 8/8