Practical Lightning Mitigation

Similar documents
The Lightning Event. White Paper

Lightning Strikes. Presented to the Greater Norwalk Amateur Radio Corporation Inc. February 8, 2017 Steven M. Simons W1SMS

ITU-T K.97. Lightning protection of distributed base stations SERIES K: PROTECTION AGAINST INTERFERENCE. Recommendation ITU-T K.

6. Internal lightning protection

DESIGN CONSIDERATION OF ELECTRICAL DISTRIBUTION AND LIGHTNING PROTECTION SYSTEMS FOR HIGH-RISE BUILDING

Lightning Protection. Wisconsin Broadcasters Association Broadcasters Clinic. 14 th October 2009 Jeff Welton Regional Sales Manager, Central U.S.

7P Series - Surge Protection Device (SPD) Features 7P P P

Equipment Rack Grounding. Technical Note

Lightning Protection for Cellular Tower Mounted Electronics

Mesh Bonded vs Isolated Bonded Earthing Network for Indoor Grounding

Grounding. Review of Grounding Considerations and Options. Rick Fletcher, W7YP. FVARC November 22, 2017

ABSTRACTS of SESSION 6

Outdoor Installation 2: Lightning Protection and Grounding

Industrial and Commercial Power Systems Topic 7 EARTHING

EVALUATION OF THE EARTH RESISTANCE VALUE FOR ESE LIGHTNING ARRESTOR TECHNIQUE FOR THE SOLAR PLANTS IN INDIA

Safety earthing. Sector Energy PTI NC. Copyright Siemens AG All rights reserved. Theodor Connor

Field Instruction. Induced voltages can occur in overhead lines, underground cables, or in switchyards.

Minimizing Lightning and Static Discharge in Broadcasting

RADIO AND TELEVISION SATELLITE EQUIPMENT

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

LIGHTNING EARTHING SYSTEM : A PRACTICAL GUIDE

Grounding and Bonding

National Radio Astronomy Observatory Socorro, NM EVLA Memorandum 41 Lightning Protection for Fiber Optic Cable. T. Baldwin June 05, 2002

Tower Grounding Training For Telecommunications Networks

ITU-T K.98. Overvoltage protection guide for telecommunication equipment installed in customer premises SERIES K: PROTECTION AGAINST INTERFERENCE

Source: EMP environnement MIL-STD-464

The Role of the Grounding System in Electronics Lightning Protection

Grounding Essentials for the Shack

Grounding Strategies for Solar PV Panels

Safety Issues Caused by High Earth Resistance and Identifying Them Using Instruments

Agenda. Earthing of Telecom Installations using Single Point Earthing. Reference Documents. How many earths? Earthing Issue...

Coaxial Cable Protection

Analysis of lightning performance of 132KV transmission line by application of surge arresters

Lightning Protection & Grounding Solutions for Communication Sites

What Are We Protecting? Over-Voltage Protection for CP Systems. Personnel (primary) Equipment (secondary)

Grounding and Lightning arrestors

Lightning and Amateur Radio Thoughts on keeping you and your rigs safe!

High Voltage Pylon earth Measurements. Tycom (Pty) Ltd Frank Barnes Comtest (Pty) Ltd Presented by Gavin van Rooy

CP Cu1. Advanced Test Equipment Rentals ATEC (2832) Multi-purpose coupling unit for CPC 100. Measurement System for

Lightning Protection: History and Modern Approaches

AC Voltage- Pipeline Safety and Corrosion MEA 2015

Simplified Approach to Calculate the Back Flashover Voltage of Shielded H.V. Transmission Line Towers

Product Classroom. Introduction. Grounding Systems. TN system. Title. Grounding System Introduction. Date October, 2016.

Earthing of Electrical Devices and Safety

DC Surge Protection of Remote Radio Units or Remote Radio Head. Presented by: Rohit Narayan Director of Sales ERICO

High voltage engineering

Cable Protection against Earth Potential Rise due to Lightning on a Nearby Tall Object

High Voltage Testing. Team 5: Justin Bauer, Matt Clary, Zongheng Pu, DeAndre Dawson, Adam McHale

A guide to GPS/GNSS antenna installations

Parameters Affecting the Back Flashover across the Overhead Transmission Line Insulator Caused by Lightning

ITU-T K.40. Protection against lightning electromagnetic pulses in telecommunication centres SERIES K: PROTECTION AGAINST INTERFERENCE

GROUNDING. What is it? Al Lewey K7ABL. Disclaimer

Applying the NEC to Amateur Radio. By Tim Kuhlman, PE

Grounding for Power Quality

INTEGRATED METHOD IN ELECTROMAGNETIC INTERFERENCE STUDIES

High Voltage Pylon Earth Measurements

Surge Protection and Grounding Issues

Power Quality. Case Study. Conrad Bottu Laborelec January 2008

Tower and Station Grounding

Reliable System Solutions for Isolated Air-Termination Systems.

Modeling insulation in high-voltage substations

Investigation on the Performance of Different Lightning Protection System Designs

Application Note (Revision NEW) Original Instructions. EMI Control in Electronic Governing Systems

PRACTICAL PROBLEMS WITH SUBSTATION EARTHING

60Hz Ratings. Typical Applications. Features & Characteristics. Ratings

2007 DEHN + SÖHNE / protected by ISO EXFS / 5392

White Paper Security Cameras, CATV, GPS and Satellite Protection

HIGH VOLTAGE Insulation Coordination

High Voltage Engineering

Best Practices for Power and Transient Protection on Rosemount Radar Transmitters

There are a wide variety of ground resistance testers available on the

When surge arres t ers are installed close to a power transformer, overvoltage TRANSFORMER IN GRID ABSTRACT KEYWORDS

Overvoltage Protection

Use of application-optimised type 1 combined arresters in low-voltage installations

CTU Presents. Grounding & Bonding for the Little Pistol & Medium Gun Ward Silver, NØAX

EPG. by Chris C. Kleronomos

LIGHTNING PROTECTION FOR MONITORING FACILITIES INTRODUCTION

APPLICATION OF THE ELECTROMAGNETIC FIELD METHOD TO STUDY A COMMUNICATION SATELLITE SITE DAMAGED BY LIGHTNING

ECE 528 Understanding Power Quality

LONGITUDINAL INDUCTION VOLTAGE MEASUREMENT ON COMMUNICATION CABLES RUNNING PARALLEL TO OVERHEAD LINES

Technological Challenges of Powerline Telecommunication

New Release - Latest Technology

Proactive Lightning Protection Concepts

Lightning transient analysis in wind turbine blades

S-Link. RF Cable Solution

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

ROEVER ENGINEERING COLLEGE ELAMBALUR, PERAMBALUR DEPARTMENT OF ELECTRICAL & ELECTRONICS ENGINEERING

Transmission of Electrical Energy

What is the Value of a Distribution Arrester

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

INTERNATIONAL TELECOMMUNICATION UNION SERIES K: PROTECTION AGAINST INTERFERENCE

Electromagnetic and Radio Frequency Interference (EMI/RFI) Considerations For Nuclear Power Plant Upgrades

ABSTRACT 1 INTRODUCTION

MAHALAKSHMI ENGINEERING COLLEGE

Lightning Flashover Rate of an Overhead Transmission Line Protected by Surge Arresters

Electrical Measurement Safety. Sponsored By:

Power Quality and Reliablity Centre

) ROTECTION AGAINST,%-0 IN TELECOMMUNICATIONS CENTRES SERIES K: PROTECTION AGAINST INTERFERENCE. ITU-T Recommendation K.40

SERIES K: PROTECTION AGAINST INTERFERENCE

Transcription:

Practical Lightning Mitigation Jerry Hogan MBA, BSEE Director of Engineering, Solara Technical Sales

Jerry Hogan, MBA, BSEE Director of Eng. Solara Technical Sales BSEE, University of Colorado MBA, University of Chicago Texas Instruments, Rockwell International, Siemens, AT&T Bell Labs, Various smaller technical companies Definer & designer of power systems & power electronics Decades of design experience (am I really that old now?) Some level of expertise in outside plant power systems 2018 Solara Inc. 2 1/17/18

Our Objectives Today Understand the energies involved. Understand the 4 levels of protection one typically designs to. Control where the lightning strikes. Control the impedances properly. Know where high inductance is helpful and where low inductance is helpful.

Map of Lightning Strikes Around the Globe

Map of Lightning Strikes in Western Hemisphere 2018 Solara Inc. 8 1/17/18

The Design Standards IEC 62305 series (Design standard in the US) IEC62305-1 Part 1:General Principles IEC62305-2 Part 2:Risk Management IEC62305-3 Part 3:Physical Damage to Structure and Life Hazard IEC62305-4 Part 4:Electrical and Electronic Systems within Structures IEC62305-5 Part 5:Services (This part was not introduced) EN 50164 series (in Europe only currently, for components) EN50164-1 Lightning protection components (LPC) Part 1: Requirements for connection components EN50164-2 Lightning protection components (LPC) Part 2: Requirements for conductors and earth electrodes EN 50164-3 Lightning protection components (LPC) Part 3: Requirements for isolating spark gaps EN 50164-4: Lightning Protection Components (LPC) Part 4: Requirements for conductor fasteners EN 50164-5: Lightning Protection Components (LPC) Part 5: Requirements for earth electrode inspection housings and earth electrode seals EN 50164-6: Lightning Protection Components (LPC) Part 6: Requirements for lightning strike counters EN 50164-7: Lightning Protection Components (LPC) Part 7: Requirements for earthing enhancing compounds 2018 Solara Inc. 3 1/17/18

IEC Terminology Term Lightning stroke Lightning flash Multiple stroke Point of stroke Lightning current Definition Single electrical discharge in a lightning flash to earth. The lightning flash may have multiple strokes Electrical discharge of atmospheric origin between cloud and earth consisting of one or more strokes A lightning flash where more than one stroke (electrical discharge) occurs Point where lightning flash strikes earth/object Current flowing at point of strike 2018 Solara Inc. 3 1/17/18

Theory of Lightning The Thundercloud The cloud needs to be 3 to 4 km deep. The taller the cloud, the more frequent the lightning. Approximately 90% of all lightning flashes are cloud-tocloud with the other 10% being cloud-to-ground flashes. Mechanics of the Lightning Strike Ionized channel (low impedance path) Up to 16 strokes have been observed using the one channel. These multiple strokes within the one lightning flash are sometimes referred to as re-strikes. 2018 Solara Inc. 3 1/17/18

Theory of Lightning 2018 Solara Inc. 3 1/17/18

Lightning, a LOT of energy per stroke: 2018 Solara Inc. 6 1/17/18

The 4 Levels of Lightning Protection In the IEC 62305 series, four lightning protection levels are introduced. LPL I offers the highest protection level (greatest level of protection), with LPL IV offering the lowest level of protection. Maximum peak current (ka 10/350 μs) Probability current is greater (%) LPL I LPL II LPL III LPL IV 200 150 100 100 1 2 3 3 2018 Solara Inc. 3 1/17/18

Standard Design Methods Used Rolling sphere used in this presentation. Mesh method Protection angle method 2018 Solara Inc. 3 1/17/18

Lightning Protection Zones 2018 Solara Inc. 3 1/17/18

Lightning Protection Zones Minimum current (ka) Probability current is greater than minimum (%) Rolling sphere radius (m) LPL I LPL II LPL III LPL IV 3 5 10 16 99 97 91 84 20 30 45 60 2018 Solara Inc. 1/17/18 2

The Problem: Lightning We erect towers cell towers, microwave towers, water towers whatever. And guess what? Shock of shocks (pun intended), they become lightning rods! 2018 Solara Inc. 3 1/17/18

So, Lightning is going to hit our towers 2018 Solara Inc. 4 1/17/18

Damage 2018 Solara Inc. 5 1/17/18

System Concepts to Consider Use rolling sphere to place lightning rods on tower & building, to the level of protection desired. Size conductors for maximum current per the sphere size. Round conductors that have higher inductance should be used here. It will limit the peak current as well as lower the voltage seen at the coaxial ground kits. Transition from high inductance to low inductance where your coaxial grounding kits are placed. We are building an inductive divider. Get the energy down to the soil. Use low inductance conductors in the soil. 2018 Solara Inc. 5 1/17/18

Cable paths make a HUGE difference! If the soil is a perfect ground, then reducing the distance from coax grounding kits to the soil-ground at the tower is the key! 2018 Solara Inc. 13 1/17/18

What can we do to reduce, or even eliminate, damage to our electronics? GOAL: Keep as much of the energy outside the building/hut/enclosure as practical/possible and AWAY from the electronics! How? Reduce Inductance Lightning really takes the path of least inductance not the path of least resistance. Let s first assume that the soil is a perfect ground. Let s assume the lighting only hits the lightning rods If we can get the energy down to the soil, instead of into the electronics, everything will work out fine. (This is mostly true) 2018 Solara Inc. 9 1/17/18

Two very different Entry Panels $ $$$ 2018 Solara Inc. 10 1/17/18

Entry Panel Inductance: 1,000V of potential/one foot of round conductor above ground. Copper strap? 300V/foot for 2 width copper strap. 3.3X better. 2018 Solara Inc. 11 1/17/18

Voltages @ Entry Panel (20kA, 8uS pulse) 6,000V for 6 feet 1800V/6 conductors = 300V for 6 or 1/20 th. (Again, assume for now that the soil is a perfect ground.) 2018 Solara Inc. 12 1/17/18

But Soil is not a perfect ground. Untreated soil is a very poor conductor with high inductance. 2018 Solara Inc. 14 1/17/18

Now this is a low inductance ground! 2018 Solara Inc. 15 1/17/18

The Complete Site 2018 Solara Inc. 16 1/17/18

Proper Grounding inside Hut 2018 Solara Inc. 17 1/17/18

Showing the grounding outside the Hut 2018 Solara Inc. 18 1/17/18

The problem: The power supply takes the abuse. It has internal capacitance. The fix: Consider using a floating plant Then shorting it out from primary to secondary, right at the power supply Multipoint Grounding 2018 Solara Inc. 19 1/17/18

In Summary: Control where the energy goes Pick level of protection desired. Place lightning rods appropriately Control the impedances properly. Reduce the soil inductance at the place you want the energy to go (green ground plane).

In Summary: Reduce the voltage seen by the electronics Route conductors horizontally between the tower and the hut as close to the soil as possible/practical. This will reduce inductance from grounding kits at the tower to the soil and eliminate induced currents, and thus the voltage generated in the surge arrestors at the entry points. Reduce inductance at entry panels with copper straps and lower the entry panel as close to soil level as you can. Use a single-point (star) ground for the hut and reference it back to your green ground plane. If you must use a multiple point ground, consider shorting out the primary to secondary of the power system, at the power system. 2018 Solara Inc. 20 1/17/18

Papers to reference Lightning Protection & Grounding Solutions for Communication Sites, 1 st Edition, Ken R. Rand Erico Lightning Protection Handbook, designing to the IEC 62305 series of lightning protection standards, Pentair CenturyLink, Technical Publication, Central Office and Remote Electronic Equipment Environments CenturyLink, Technical Publication, Grounding - Central Office and Remote Electronic Equipment Environments Motorola Standards and Guidelines for Communication Sites International Telecommunication Union, ITU Handbook on Telecommunication Outside Plants in Areas Frequently Exposed to Natural Disasters Progress Energy, Network Design Unit, Communications Site Grounding & Bonding Specification 2018 Solara Inc. 23 1/17/18

Disclaimer Each project is different in nature and location. This presentation is meant to be educational only. If you follow the advice within and your site blows up, it s on you. Feel free to contact us with questions.

Solara Technical Sales We define, design and furnish high-availability power solutions for shipment anywhere in the Western Hemisphere. Founded September 2001 Headquarters located in Knoxville, TN Systems Integration in Knoxville, TN & Oldsmar, FL Owner/President: Kevin Fellhoelter, P.E. (Texas)

Solara Inc. www.solaratech.com Kevin Fellhoelter (214) 906-9853 Los Angeles Coliseum