IESNA LM (NOT INCLUDE SPATIAL NON-UNIFORMITY OF CHROMATICITY) ELECTRICAL AND PHOTOMETRIC MEASUREMENTS OF SOLID-STATE LIGHTING PRODUCTS

Similar documents
IES LM MEASUREMENT AND TEST REPORT. Test Model: SRLED-RTUS24-4K. Jeanne Han/Safety Manager

LM Test Report

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

LM Test Report

LM Test. for LED. Cabinet

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

LM Test Report

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

IES LM Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

IES LM Report. Technical Requirements Table, V4.0, DLC Premium DesignLights Consortium Product Application Category

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA

Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

LED14.5WPAR30S/FL/827-DIM

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

71332 LED Dusk To Dawn (Area Light)

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

Morris Products 53 Carey Road, Queensbury, NY 12804

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

NVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

1X4 LED Panel Light RoHS 0-10V Dimmable QPL ID #

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE:

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

LED DOWN LIGHT (Dimmable)

Diogen Lighting,Inc 14 Inverness Drive East,Ste.E-128 Englewood, CO T8L W BEST Test Service Shenzhen Co., Ltd.

NVLAP LAB CODE:

NVLAP LAB CODE:

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

REVOLUTION LIGHTING TECHNOLOGIES INC

ApprovedMethod: Electricaland Photometric. Measurements of Solid-State Lighting Products

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

Morris Products 53 Carey Road, Queensbury, NY 12804

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

Cat# LED Classic Large Wall-Pack

NVLAP LAB CODE:

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

LM Test Report

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

Approved Method:Electricaland Photometric

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

2X4 LED Panel Light RoHS 0-10V Dimmable QPL ID #

IES LM MEASUREMENT AND TEST REPORT For

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

Eternal Shine Technology Co.,Ltd. EST

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

RoHS 0-10V Dimmable QPL ID # PXQGXDYK

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

Transcription:

IESNA LM-79-08 (NOT INCLUDE SPATIAL NON-UNIFORMITY OF CHROMATICITY) ELECTRICAL AND PHOTOMETRIC MEASUREMENTS OF SOLID-STATE LIGHTING PRODUCTS MEASUREMENT AND TEST REPORT For ELEC-TECH INTERNATIONAL CO., LTD NO.1 Jinfeng Road, Tangjiawan Town,Zhuhai City, Guangdong Province,P.R of China. Model: 520244/520263 Report Type: Original Report Test Engineer: Jack Zhou Report Number: R2DG120412060-10-M2 Test Date: 2011-12-15 to 2011-12-26 Report Date: 2013-08-15 Product Type: LED PAR38 Lamp Reviewed By: Jeanne Han/Safety Manager This version report No. R2DG120412060-10-M2 at 2013- Revised Note: 08-15 replaced the previous report No. R2DG120412060-10-M1 at 2012-06-04 Bay Area Compliance Laboratories Corp. (Shenzhen). 6/F, the 3rd Phase of WanLi Industrial Building, Prepared By: ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China. Tel: +86-755-33320018 Fax: +86-755-33320008 Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP,NIST, or any agency of the Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

TABLE OF CONTENTS 1 - GENERAL INFORMATION... 3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)... 3 1.2 OBJECTIVE... 3 1.3 TEST FACILITY... 3 2 - SUMMARY OF TEST RESULT... 4 3 - TEST METHOD... 5 ATTACHMENT A SPECTRAL FLUX... 6 ATTACHMENT B LIGHT INTENSITY TEST DATA... 8 ATTACHMENT C EUT PHOTO... 20 C1.EUT PHOTO... 20 C2.EUT PHOTO... 20 Page 2 of 20

1 - GENERAL INFORMATION 1.1 Product Description for Equipment under Test (EUT) EUT Description Electrical Rate Brand Manufacturer Model LED PAR38 Lamp 520244 is tested model.difference: Only color of finish and the packaging, The electronic circuit and basic construction are the same AC 120V 60Hz 16W 3000K ETI ELEC-TECH INTERNATIONAL CO., LTD 520244/520263 1.2 Objective The following test report is prepared on behalf of ELEC-TECH INTERNATIONAL CO., LTD in accordance with the following American National Standards or illumination Engineering Society of North America Test Guides: ANSI C78.377-2008 Specification for the Chromaticity of Solid State Lighting Products IESNA LM-79-2008: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits Related Power Quality Requirements for Lighting ANSI/UL 153-2005: Portable Electric Luminaires UL 1598-2004: Luminaires ASTM E 283-2004: Restricted air movement IESNA LM-16: Correlated Color Temperature INSNA LM-58-94: Color Rendering Index and Correlated Color Temperature CIE Publication No.13.3-1995: Method of Measuring and Specifying Color Rendering of Light Sources 1.3 Test Facility The test facility used by Bay Area Compliance Laboratories Corp. (Shenzhen). is located at 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade ZoneShenzhen, Guangdong, China. Bay Area Compliance Laboratories Corp. (Shenzhen). is a National Institute of Standards and Technology (NIST) accredited laboratory, under the National Voluntary Laboratory Accredited Program (NVLAP). The NVLAP Lab Code is 200707-0. Page 3 of 20

2 - SUMMARY OF TEST RESULT SPECTRORADIOMETRIC TESTING IN INTEGRATING SPHERE PHOTOMETRIC - Total Integrated Flux (Lumens) 740.244 SPECTRORADIOMETRIC - Observer - Chromaticity Ordinate x 0.4265 Chromaticity Ordinate y 0.3973 Observer - Chromaticity Ordinate u 0.2467 Chromaticity Ordinate v 0.3447 Correlated Color Temp CCT (K) 3128 Color Rendering Index (CRI) 83.8 Total Radiant Flux (W) 2.399 ELECTRICAL - Input Voltage (Volts AC) 120.04 Input Current (A AC) 0.126 Input Power (Watts) 14.3 Power Factor 0.942 EFFICACY - Lumens/Watt 51.765 LUMINOUS INTENSITY DISTRIBUTION Center beam candlepower(if applicable)(cd) 4053 Beam angle(if applicable)( ) 21.4 Zonal lumens in the 0-60 zone(%) 99.8% Zonal lumens in the 60-90 zone(%) 0.2% Zonal lumens in the 90-120 zone(%) 0.0% Zonal lumens in the 120-180 zone(%) 0.0% Note: The test data was only good for the test sample. It may have deviation for other test sample. Page 4 of 20

3 - Test Method Test methods according to IESNA LM-79-08 following chapter: 4.0 SEASONING OF SSL PRODUCT For the purpose of rating new SSL products, SSL products shall be tested with no seasoning. 5.0 STABILIZATION OF SSL PRODUCT Before measurements are taken. The SSL product under test shall be operated long enough to reach stabilization and temperature equilibrium. The time required fir stabilization depends on the type of SSL products under test. The stabilization time typically ranges from 30 min (small integrated LED lamps) to 2 or more hours for large SSL luminaries. The SSL product during stabilization shall be operated in the ambient temperature as specified in section 2.2 and in the operating orientation as specified in 6. It can be judged that stability is reached when the variation (maximum minimum) of at least 3 reading of the light output and electrical power over a period of 30 min, taken 15 minutes apart, is less than 0.5%. The stabilization time used for each SSL product shall be reported. 9.0 TEST METHODS FOR TLTAL LUMINOUS FLUX MEASUREMENT 10.0 LUMINOUS INTENSITY DISTRIBUTION 11.0 LUMINOUS EFFICACY 12.0 TEST METHODS FOR COLOR CHARACTERISTICS OF SSL PRODUCTS 13.0 UNCERTAINTY STATEMENT The uncertainty of the light output measurements is U=1.50% (K=2), the uncertainty of the correlated color temperature measurements is U=14K (K=2), at the 95% confidence level. This calibration results traceable to the NATIONAL INSTITUTE OF METROLOGY (NIM). Remark: 1. 0 hour season, Pre-heating the lamp for 45 minutes at least; 2. Ambient:65%RH, 25 ; Page 5 of 20

Attachment A Spectral Flux Page 6 of 20

Page 7 of 20

Attachment B Light Intensity Test Data Page 8 of 20

Page 9 of 20

Page 10 of 20

Page 11 of 20

Page 12 of 20

Page 13 of 20

Page 14 of 20

Page 15 of 20

Page 16 of 20

Page 17 of 20

Page 18 of 20

Page 19 of 20

C1.EUT PHOTO Attachment C EUT PHOTO C2.EUT PHOTO ***********END OF REPORT*********** Page 20 of 20