Rockfon System OlympiaPlus A Impact 1A

Similar documents
ROCKFON System Olympia Plus

Olympia Plus Sports Ceiling Impact Class 1A

CI/SfB. October RockLink Integra. Installation system

Installation guide. ROCKFON VertiQ. ROCKFON System T, ROCKFON System HAT. Impact-resistant and high impact-resistant acoustic wall panel solutions

Installation Guide. Rockfon Eclipse

Installation Guide. Rockfon Eclipse

AXIOM Classic Trim. Assembly and Installation Instructions

AXIOM Classic Trim Installation Instructions

AXIOM Classic Trim. Assembly and Installation Instructions 1. GENERAL

OWAtecta. OWA metal ceilings. OWAtecta Metal ceilings

Wall mounting with holding profile

COMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE

METALWORKS TARTAN PANELS General Installation Instructions

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. International Version

AXIOM KE CANOPY Installation Guide

CI/SfB. January Rockfon Color-all

Installation Manual 0318

metalworks Plank Assembly and Installation Instructions 2.1 Read this entire document before proceeding with installation.

Standard Solo 8 planks in maple veneer with aligned 1/2 reveal create a panelized appearance. 1/2 Reveal. Plank thickness 5/8 (16 mm)

Installation Instructions

LUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February

Hospital Grade Welded Ceiling System

rondo exangle drywall finishing sections

Classic Exposed Tee System (24" x 24", 24" x 48", and 24" x 72") Floating Clouds and Perimeter Wall Attachment

Ceiling Installation

Trim (Aluminum Substrate)

Elam -range of products: Vanha Porvoontie 36 FIN MÄNTSÄLÄ Phone: +358 (0) Fax: +358 (0)

Technical Data VARIABLES

General Installation Guidelines

Connect by Ecophon engineered for your convenience

METALWORKS Concealed. Installation Instructions

Technical Manual. ceiling - Seamless

Light Structural Main Runner Light Structural Infill Tees. Straight Connector. Strut Structural Tee thread

Installation Instructions Palladium Wall Panels - Demountable Factory Finished Edges and Field Cut Edges

Carousels - Overlapping Slat

T-GRID SYSTEM WIDE CLEANROOM CEILING GRID SYSTEM

Prestige 2Com Technical

WOODWORKS. Linear Solid Panels. Installation Instructions CEILING SYSTEMS. 1. General

Shapes Siding. Perfection Shingles. Chalk Line

WOODWORKS Concealed. Assembly and Installation Instructions

Table of Contents. Linings/Sheathing/Dry partitioning. Rigid sheet fine linings and panelling / Rev

Table and Furniture Base Fittings Plinth Adjusting Fittings

Horizontal Shaft Wall

INTERIOR INSTALLATION

SHIPLOCK CLADDING PRODUCT GUIDE INSTALLATION TECHNICAL SPECIFICATIONS CARE & MAINTENANCE

W-H 1000 SYSTEM Wall cladding. Metal product

CARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)

UCO Vistabord Fixing Manual

Connect by Ecophon engineered for your convenience

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

WoodWORKS Channeled Plank

ClicWall. Decorative wall covering

PERIMETER SMOKE SEALS

Technical Data VARIABLES

SECTION BULLET- RESISTANT DOORS

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

KERRAFRONT INSTRUCTION FOR INSTALLATIONS AND USE. Cellular cladding FS-201 / FS-202. kerrafront.com

Technical Data VARIABLES

EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS

Perforation Options for Rockfon Specialty Metal Ceilings

ARMSTRONG METALWORKS BAFFLES Installation Guide

CEILING SYSTEMS. MADERA VECTOR Semi-concealed system on exposed 24mm grid. Technical Data Sheet. [Between us, ideas become reality.

ECOPHON Focus Ds 4x4 Installation Manual

INTERNAL LININGS INSTALLATION GUIDE

Walls Fact Sheets. Partition Walls and Walls Cladding. Perforated Board. Sandwich Board

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

Installation Instruction

How to Install the QuickHang Installation Kit

Method of Build 1. Fire. Sound

CertainTeed Ceilings

INSTALLATION GUIDE SLIMLINE ROOF LANTERN 4 PANE CONFIGURATION

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT

Stratco Sanctuary INSTALLATION BEFORE YOU START TOOLS REQUIRED GUIDE

SLIDE 06 Solutions Document/Installation Manual

Installing Novi Siding Trim

Connector Technology, Shelf Supports Connection Fittings

Installation Guide. Versilux Lining INTERIORS

Cembrit Patina. Cembrit Cover. Cembrit Solid. Cembrit Transparent

SAGIREV Installation Manual

EMAC 001 ACCESS PANEL

Siding Systems NOVIKSTONETM DS DRY STACK STONE INSTALLATION GUIDE

METALWORKS Linear (Interior & Exterior Applications)

Instructions to Build Decking

Installation Instructions

Technical Note No. 026

The Passive Fire Protection Handbook

Posi-Joist Installation Guide. A guide for storage, handling and installation of the MiTek Posi-Joist floor system

INSTALLATION GUIDE. Biowood Outdoor Wall Panel BWWPO20018 Shiplap 8x6 Deep. Green Resources Material Australia Pty Ltd

Soundscapes Shapes Acoustical Clouds

Garage. Door. Unframed Tracked Fitting Instructions V2.2. fitting instructions. Warning!

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No

1. Show the following information with additional information necessary to indicate shop compliance with the requirements of this section.

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

DUALCASE VERSATILE ALUMINIUM SIGN SYSTEM

FOR PROFESSIONAL GARAGE DOOR INSTALLERS

Clopay Models 835/837 Sliding Door System Installation Guide

A. ASTM D Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

method of build Komfire-75 partitioning system 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims KOMFORT

INSTALLATION MANUAL STORAGE

Transcription:

System description Rockfon System OlympiaPlus A Impact 1A Ceiling systems for special applications Impact resistance SYSTE GRP WAR YEARS IT LIM ED E very single tile is demountable for easy and fast access to installations M NT Y ighest impact resistance H Class 1A (EN13964-Annex D) A esthetically appealing white surface RA I deal combination of good acoustics and impact resistance for sports halls

DESCRIPTION This high impact resistance system consists of the Chicago Metallic 50 mm Bandraster 3050 grid with a specially designed H-shaped holddown frame installed with Rockfon impact resistant 40 mm tiles Boxer or Samson when exposed to ball impact. The grid profiles are made from galvanized Z100 steel and painted white as standard. The system is intended to be suspended from soffits using nonius hangers. Bandraster cross connectors should be placed into cross tees and then hooked onto and mechanically fastened to main runners using self tapping screws. For walls, the ends of the main runners and cross tees should be connected to the wall using bandraster wall connectors. The hold-down frame can be fitted after the Rockfon Boxer / Samson tile has been installed. 7 10 max. 450 mm 1 max. 1200 mm 5 4 3 9 6 2 max. 1200 mm 40 mm Connecting a cross tee to a main runner. Installing Rockfon Boxer / Samson tiles. Straight A edge tile ensuring fast mounting and full demountability. 2

SYSTEM COMPONENTS AND CONSUMPTION GUIDE Dimension (mm) TILE A edge tile CHICAGO METALLIC 50MM BANDRASTER 3050 HOLD-DOWN FRAME WALL ANGLES ACCESSORIES 1 2 3 4 5 6 7 8 9 10 11 Main runner 50mm 3050mm Cross tee 50mm 1150mm Hold-down C-profile 1168.6mm Hold-down C-profile 555mm Straight connector Consumption/m² Angled connector Perimeter wall angle trim Bandraster coupling Bandraster cross connector Nonius hanger Bandraster wall connector 1200 x 1200 0.70 pcs/m² 0.83 lm/m² 0.83 lm/m² 1.62 lm/m² 0.77 lm/m² 2.77 pcs/m² 2.77 pcs/m² 1) 0.23 pcs/m² 1.39 pcs/m² 0.7 pcs/m² TILE A EDGE CHICAGO METALLIC 50 MM BANDRASTER 3050 1. MAIN RUNNER 50 MM 3050 MM 2. 50 MM CROSS TEE HOLD-ON FRAME 3/4. HOLD-DOWN C-PROFILE ACCESSORIES WALL ANGLE 5. STRAIGHT C-PROFILE CONNECTOR 6. ANGLED C-PROFILE CONNECTOR 7. PERIMETER TRIM ACCESSORIES 8. BANDRASTER COUPLING 9. BANDRASTER CROSS CONNECTOR 10. NONIUS HANGER 11. BANDRASTER WALL CONNECTOR 3

PERFORMANCE Impact resistance Class 1A, tested in accordance with EN13964-Annex D. Impact resistance classifications confirm the system s capability to withstand incidental or occasional impact. System load bearing capacity MAX.LOAD BEARING CAPACITY (KG/M²) Hanger distance (mm) Module size (mm) Max. 2.5mm deflection Max. 4.0mm deflection 1200 1200 x 1200 20.2 33 Corrosion resistance Class B (EN13964) Demountability Tiles mounted in Rockfon System Olympia Plus A Impact 1A are fully demountable. Fire resistance Some Rockfon ceiling systems have been tested and classified in accordance with European norm EN 13501-2 and/or national norms. Please contact ROCKFON. 30 YEARS System warranty All Rockfon ceiling systems have a 30 year warranty. Contact Rockfon for more information and conditions. COMPATIBLE TILES Rockfon System Olympia Plus A Impact 1A can be installed with the following Rockfon tiles: EXACT SIZE (MM) MODULE DIMENSIONS (MM) 1166 x 1166 1200 x 1200 Boxer (40 mm) Samson (40 mm) 4

GRID INSTALLATION Grid layout and hanger location This ceiling system has a module dimension of 1200 x 1200 mm. Unless otherwise specified, the suspension system must be symmetrical within the room. If size (a) is used at the start of the longitudinal direction, then this size must also be used at the other end of the room. It is not recommended to fit tiles which have been cut to a length which is shorter than half the width or length of the tile. Min. 300mm 1200 mm 1200 mm Perimeter trim Bandraster Cross Bandraster Hanger Wall connection Cross connection Frame profiles Coupling frame to Bandraster Coupling frame profile to frame profile Installation requirements During and after grid installation, it is important to check that Bandraster profiles are perfectly aligned horizontally. A maximum level difference of +/- 1 mm is recommended between profiles and should not be added. This tolerance is valid for all directions. It is important to check the squareness of the angles between the bandraster main runners and the bandraster cross tees. This can be easily done by comparing the measurements of the two diagonals. See examples and recommended tolerances on the drawings below. MODULE SIZE (L X W) DIAGONAL (D) TOLERANCE MM D mm 1200 x 1200 1626.34 +/- 1 5

Hold-down frame The Rockfon tiles (40 mm thick) are held in place by an H-shaped hold-down frame. This is made from 2 x 2 lengths of C- profile. The two long C-profiles bridge the distance from main runner to main runner, whilst the two short C-profiles bridge the distance between the two long C-profiles. The short and the long C-profiles are connected together by the straight C-profile connector. Angled C-profile connectors are fitted to the end of the long C-profiles and clicked into the slots in the main runners. The hold-down H frame should be installed symmetrically in the 1200 x 1200 mm module. NB: Pay special attention to the location of the main runner grid connectors so that the angled C-profile connectors can be clicked in place. Slots must be aligned Perimeter trims Grid component attached to a wall. Hold-down C-profile attached to a wall. Fit the bandraster wall connector to the main runner or cross tee using self tapping screws. Fasten the connector to the wall using appropriate fixings. Fit the angled C-profile connector to the C-profile using self tapping screws. Fasten the connector to the wall using appropriate fixings. 6

ASSEMBLY A symmetrical distribution of tiles gives the most attractive final result. Connection between the ceiling and a wall The battens and perimeter trims must be levelled against a wall (and be aligned). The distance between fixing points on a perimeter trim must not exceed 300 mm. For fire-resistant constructions, the perimeter trims must be attached directly against the wall or be fitted with fire-resistant battens. Connection between the ceiling and curved vertical surfaces When the ceiling connects with a curved vertical surface, pre-shaped trims must be used. 7

DEMOUNTING Demounting Rockfon tiles The tiles can be easily demounted. As a result of the space between the back of the ceiling tile and the bottom of the hold-down frame, the tiles can be raised approximately 10 mm. Every tile can be removed by disconnecting two of the four angled C-profile connectors out of the cross tees using the removal tool supplied, pliers or a hook. The tiles can be easily demounted. Further information Resistance to corrosion The system meets corrosion class B in accordance with table 7 of the European product standard EN 13964. All the parts are made from Z100 steel (minimum zinc layer of 100 g/m 2 ). As a result, the system is suitable for use in rooms with a maximum relative humidity of 90% at a maximum temperature of 30 C. MINIMUM INSTALLATION DEPTH (MM) Tiles mounted in Rockfon System Olympia Plus A Impact 1A are fully demountable. The installation depth is defined as the distance from the underside of the tile to the underside of the substrate, where the hangers are fixed. D is the minimum installation depth for easy tile installation and demountability. MOUNTING METHOD Suspended with nonius hangers D = MINIMUM INSTALLATION DEPTH 200 mm D 8

PERIMETER FINISH OPTIONS Below are examples of perimeter finishing. Further details can be found on www.rockfon.co.uk 1. Perimeter finish with wall angle trim 9

SERVICE INTEGRATION Rockfon ceiling tiles are easy to cut and therefore it is very easy to integrate service installations in our ceiling tiles. The cut-outs can be made with a simple utility knife. Specific lights have been tested in accordance with EN13964 Impact resistance class 1A. Impact resistance of other types of lights is not guaranteed. Contact your local Rockfon technical service for more information on suitable lighting fixtures and accessories and availability of CAD drawings of the different services integrated in ROCKFON system Olympia Plus. Special solutions with integrated services are, if available, shown on page 13 of this document, in the Tools section. Planning A thorough planning and installation scheduling of the project/site will result in less re-work and less ceiling tile damages. Rockfon recommends discussing the installation thoroughly and well in advance with other installers that have to work in or near the suspended ceiling. By doing so damaged ceiling tiles and dirty spots on the finished ceiling surface can be avoided, which reduces project costs. Drawing A Drawing B Drawing C 10

GENERAL INSTALLATION Perimeter finishing Junction between ceiling and wall or other vertical surface The perimeter trim should be fastened to vertical surfaces at the required level using appropriate fixings every 300 mm. Ensure that butt joints between adjoining lengths of trim are neat and that the trim is free from kinks and remains true and level. For the best aesthetics, use as long a length of trim as possible. The minimum recommended cut length is 300 mm. Timber trims, timber shadow battens and metal Shadow mouldings should not be used with fire resisting/protecting ceilings. Junction between ceiling and curved vertical surface The use of a preformed curved perimeter trim is the most appropriate method. Rockfon can provide details of curved perimeter trims on request. Corners Perimeter trims should be neatly mitred at all corner joints. Overlap mitres are acceptable for metal trims on internal corner joints unless specified otherwise. Suspension grid Unless specified otherwise, the ceiling should be set out symmetrically and where possible, perimeter tiles should be greater than 200 mm in width. The hangers should be fastened with appropriate top fixings and to the bandraster at 1200 mm centres (or less with greater load). For proper grid installation, make sure the bandraster profiles are perfectly aligned horizontally and diagonals or modules are equal (see requirements and tolerances on page 5). Bandraster joints should be staggered and within 450 mm of the end of the bandraster where it terminates at a perimeter. Additional hangers may be necessary to support the weight of ceiling services. Tiles Rockfon recommend the use of clean nitrile or PU coated gloves when installing Rockfon tiles in order to avoid fingerprint marks on the surface. Cutting is made easy with a sharp knife. All offcuts and holes must be treated according to local Building Regulations. Note! Certain smooth matt surfaces are directional. To ensure consistency of the finished ceiling, it is important that all tiles are installed in one direction indicated by the arrow printed on the back of each tile. TOOLS Rockfon has developed specific tools that are available on www.rockfon.co.uk For further information see CAD library Generate specification texts for our products Explore our vast library of reference projects 11

09.2017 All colour codes mentioned are based on the NCS - Natural Colour System property of and used on license from NCS Colour AB, Stockholm 2012 or the RAL colour standard. Subject to alterations in range and product technology without prior notice. Rockfon accepts no responsibility for printing errors. Rockfon ROCKWOOL Limited T/A ROCKFON 14th Floor, Chiswick Tower, 389 Chiswick High Road, London W4 4AL Tel: +44 (0) 208 222 7457 Fax: +44 (0)20 8222 7458 www.rockfon.co.uk