INTELLIGENT POWER FACTOR REGULATOR

Similar documents
DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T

NEW. DIGITAL SIGNAL GENERATOR Model KM 2001 ELECTRICAL SPECIFICATIONS : An ISO 9001:2008 Company FEATURE :

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

1000A AC DIGITAL CLAMPMETER MODEL KM 3060

DIGITAL INTELLIGENT POWER FACTOR REGULATOR

2 IN 1 DIGITAL COATING THICKNESS GAUGE MODEL - KM 118A OPERATION MANUAL LIST OF PRODUCTS

DIGITAL MULTIMETER 405

DIGITAL CLAMPMETER MODEL

GENERAL SPECIFICATIONS : Sensing : Average Sensing. Basic Accuracy : ±(0.8%rdg + 2dgt)

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

OPERATION MANUAL. Multi-Function LCR LIST OF PRODUCTS MODEL KM 520B

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

AC FLEXIBLE CURRENT PROBE CA 3000

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

Oberebenestrasse Bremgarten Switzerland Tel Fax

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

Worldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual

Circuit Breaker Finder

For detailed specifications and ordering info go to

4. CONNECTIONS. Make sure all connections to and in your Universal Rectifier are tight.

MS6813. Users Manual TEST BNC MS6813 TRANSMITTER SHIELD OFF CONT TONE. Multi-Function Wire Tracer. Short Reversed Miswire Split Pairs

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

OPERATION MANUAL OF MODEL TH2681/A HIGH RESISTANCE TESTER

USER MANUAL. WBP314P71 active power transducer. (3-phase 4-wired)

OPERATING AND MAINTENANCE INSTRUCTIONS FOR CONSTANT CURRENT RECTIFIERS USING SATURABLE CORE REACTORS

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

OVA-50 Optical Variable Attenuator User s Manual

SPM-50 RF Spectrum Power Meter PC Software User Manual

AT Advanced Wire Tracer. Users Manual

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Model Number Structure

AT Underground Cable/Pipe Locator System. Users Manual Mode d emploi Bedienungshandbuch Manuale d Uso Manual de uso Användarhandbok

INSTRUCTION MANUAL UTL260

Commissioning and Maintenance of Power Factor Correction Systems

SMART TWEEZERS Model ST-1 User s Manual Version 1.0

1523, 1524 Thermometer Readout User s Guide

INSTRUCTION MANUAL INF Fax: (503)

DM-45 Digital Multimeter

QUICK REFERENCE OVERVIEW. Display Area

Power Factor Controller BR 5306 / 5312

12B/18 MultiMeter Instruction Sheet

COMPLY WITH HI-VOLTAGE PHASE CURRENT MEASUREMENT M-140HC INSTRUCTION MANUAL

Phase-sequence Phase-loss Relay

312, 316, 318. Clamp Meter. Users Manual

CT238A. AC/DC Current Probe. User Manual. For detailed specifications and ordering info go to

712B. Users Manual. RTD Calibrator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

ALPTEC POWER FACTOR CONTROLLER

USER S MANUAL. Rail-mounted temperature transmitter ATL

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

Electrical Multimeter

374 FC/375 FC/376 FC Clamp Meter

INSTRUCTION MANUAL LM192 LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

4 Channel Frequency Conscious Noise Gate. Operation Manual

User's Manual. Model f/1f Power Clamp-on Meter

INSTRUCTION MANUAL MARTINDALE EZ150 / EZ650 SOCKET TESTER 1. INTRODUCTION. ELECTRIC Trusted by professionals

NOTE: Fully read and understand this manual before using this Digital Multimeter.

712C. Users Manual. RTD Calibrator

USER S MANUAL EMPOWER POWER METER TRINITY. Empower Operational Manual

User's Manual. Clamp-on Power Datalogger. Model

INSTRUCTION MANUAL LM195 LED LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

MODEL: Duo Product id:duomk214f Duo OWNER S MANUAL

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

Pen Multimeter. Model

Pen Multimeter. Model

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

ICM 136R Operating Instruction Electrical Clamp-Multimeter

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

OWNER S MANUAL DANGER

Power Factor Controller BR 6000

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

DMM8900 SERIES USERS MANUAL

Model Number Structure

Single-phase Current Relay

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

USER S MANUAL VAF POWER METER TRINITY. VAF Operational Manual

MODEL 421 Over/Under Motor Load Monitor

OWNER S MANUAL DANGER

AC68C. Users Manual. True RMS AC/DC Clamp Multimeter. PN July Amprobe Test Tools. All rights reserved.

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Instruction Manual Model M Switch, DPDT, Manual Select

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Dawson DDM190. Digital Multimeter User s Manual

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Radio Remote Controls Manual K Series

Instruction Manual ET4 ELECTRICAL TESTER

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Model UT20B: OPERATING MANUAL Table of Contents (1)

Mounting Instructions / Manual MV1171

Ior DIGITAL LEAKAGE CLAMP TESTER MCL-400IR INSTRUCTION MANUAL

Instruction Manual ICM 135R Electrical Clamp Multimeter EN FR IT DE ES

742A Series Resistance Standards

Transcription:

INTELLIGENT POWER FACTOR REGULATOR Model- KM-PFR-S-9-04 / KM-PFR-S-9-08 / KM-PFR-S-9-12 FEATURES : Display : Power Factor Line Voltage Input Load Current Precise compensation of Reactive Power with automatic calculation of C / K.. KVAR based Power Factor Controller User friendly menu for simple setting of various Parameters. High sensitivity, operates even at 50 ma current signal. Over Voltage & Low Voltage protection. Automatic & Manual operation Stores setting Data even if there is a power failure. Standard DIN Size 144 mm x 144 mm for easy installation in control panels. TECHNICAL DATA : DIMENSION Rated Volatage : AC 440 V 50H z / 60Hz ( L-L). Rated Current : AC 50 m A ~ 5A 50Hz / 60Hz Output Relay Rating : AC 220 V ; 8 A ; 50 Hz Display Power Factor : Lag 0.001 ~ Lead 0.001 80mm Measure Power : 0-9999 KVAR Low-Voltage Protection : 300 V ( L - L ) Ambient Temperature : 20 C ~ 50 C Protection Class : Ip40 Model : KM-PFR-S-04 : 4 step KM-PFR-S-08 : 8 steps KM-PFR-S-12 : 12 steps 144mm CONNECTION DIAGRAM : 144mm 1 2 3 2A 11 12 13 A B P J12 J6 J1 10A C 138 x 138mm C12 C6 C1 T 26 25 24 23 22 21 20 19 18 17 16 15 14 Note: All Specification are Subject to change without prior notice. G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct : 022-24156638. Tel.: 022-2 4124540, 24181649 Fax : 022-24149659 Email : kusam_meco@vsnl.net, Website : www.kusamelectrical.com, www.kusam-meco.co.in D:\Chhaya\My Documents\Chhaya\backup\catlog\New cat\km-pfr-s-04/04/12.cdr

REACTIVE POWER AUTOCOMPENSATION CONTROLLER KM-PFR-S-9-04 KM-PFR-S-9-08 KM-PFR-S-9-012 USER MANUAL

1.GENERAL KM-PFR-S-9 series Reactive Power Autocompensation Controller is used for the automatic regulation for capacitor compensation devices of low voltage distribution system (hereinafter referred to as controller It makes the power factor reach user's preset state, to enhance the utilization efficiency of power transformer, reduce line loss and improve the voltage value of power supply, thereby to increase the economic benefit and social benefit. 2.FUNCTION CHARACTERISTICS 1. To calculate input-cut capacity of capacitor by reactive power, with high compensation precision. 2. High measuring precision for power factor, with wide display range. 3. Initial phase preset (software regulation synonymous end or current signal polarity). 4. With two types of control modes: power factor and reactive power. 5. Various control parameter can be adjusted through full digital display. visual and easy to use. 6. With two kinds of working modes: auto running and manual running. 7. With over voltage and under voltage protection functions. 8. With power down protection functions, data will not lose. Low input impedance of current signal 0.01W. 3.OPERATING CONDITIONS 1. Altitude should not exceed 2500m. 2. Ambient temperature: -25 C ~ +50 C. 3. Air humidity should not exceed 50% at 40 C, and not exceed 90% at 20 C. 4. No corrosive gas, conductive dust and flammable medium around. 5. No fierce vibration in installation place. 4.TECHNICAL DATA Rated working voltage : AC 440V /380V 50Hz / 60Hz (L-L) Rated working current : AC 60mA ~ 5A Capacity of output contact : AC 220V 7A 50Hz Display power factor : lag 0.001 - lead 0.001 Measure reactive power : 0 ~ 9999Kvar Under voltage protection value: 340V Control mode: optimize automatically/ input disconnect circularly Sensitivity: 60mA Protection grade: shell IP40 5.CHARACTERISTICS OF WORKING MODES At any moment control just can work under one working mode. Characteristics of power factor control mode : The controller has been adjusted to power factor control mode before leaving factory. All parameters have been preset according to the reasonable mode. User just performs correct connection and it will work normally, no other operation is required. Characteristics of reactive power control mode : can accurately control the input-cut and zero input-e vibration of capacitor groups. It is applied to all working environment especially the occasions with light load and large capacity. 6.Selection of power factor control mode and reactive power control mode Selection of the working mode of controller is separated by the different taken value of PA - 4 parameter. If user adjusts the parameter within (1-12), it shows that controller works under power factor mode, the value of data means the number of output loop of controller. If user adjusts the parameter wit( (50-5000), it shows that under reactive power control mode, the value of data means the transformation ratio of total current transformer of user system.

Note: Under reactive power control mode. before using the controller, user must input the transformation ratio of actual current and all parameters such as capacity of capacitor for the controller. 7. Display contents of each menu under different working mode Working mode Power factor Reactive power Manual running Reactive power control mode Display power factor Display reactive power Display power factor Power factor control mode Display power factor Display A u to Display power factor 8.DEBUGGING Warning: During the process of debugging, user must comply with the following steps to debug, in which the items with marked are the operation steps for controller working under reactive power control mode. 1. Assemble the compensation device according to the requirements of connecting diagram and check carefully for one time to eliminate the mistakes that may bring serious potential safety hazard. 2. Switch on the compensation device, the controller will enter into auto running state. 3. Input the transformation ratio of current transformer of on site signal. Please see menu operation. 4. Input the capacity of capacitor groups of each branch circuit. Please see menu operation. 5. Operate Menu key and the indicator light of manual running shines, as one method for debugging compensation device, manual running can check whether the connection is correct or not. Operating increasing key will input one capacitor group and operating decreasing key will cut one capacitor group. Note: The output terminal, the corresponding capacitor value of which is zero, can't be performed with input-cut action. The above operation can he performed without current signal. 6. To make the controller automatically input-cut capacitor groups, besides the user should set the menu to "power factor" or "reactive power", there also should be with the current signal lagging the voltage signal and the system voltage should not exceed the over voltage protection value and not lower than the under voltage protection value,. 9.PRESS KEY FUNCTIONS N a m e S y m b o l C o n t e n t s M e n u k e y In c re a s in g k e y D e c re a s in g k e y M E N U T o c h o o s e m a in m e n u a n d s u b m e n u. N o te : P re s s m e n u k e y fo r 3 s to e n te r in to p a ra m e te r p re s e t m e n u. T o in c r e a s e d a ta w h e n p r e s e ttin g p a r a m e te r, to in p u t c a p a c ito r g r o u p s w h e n fo r m a n u a l r u n n in g T o d e cre a se d a ta w h e n p re se ttin g p a ra m e te r. to c u t c a p a c ito r g ro u p s w h e n fo r m a n u a l ru n n in g. U n d e r " P o w e r fa c to r " m e n u : P o w e r fa c to r c o n tr o l m o d e d is p la y s s e c o n d a ry c u rre n t M a R e a c tiv e p o w e r c o n tro l m o d e d is p la y s p rim a ry c u rre n t A U n d e r " R e a c tiv e p o w e r " m e n u : D is p la y v o lta g e s ig n a l v a lu e V 10. MENU OPERATION 1. Steps for adjusting parameters under power factor control mode. Choose the preset parameter Press "Menu" key for 3s to make indicator light of "Parameter preset" shine Parameter code Code meaning Parameter range P A - 1 Input threshold 0.70 ind-0.70cap Repress "Menu" key P A - 2 P A - 6 1-250 S Repress" Menu" key P A - 3 Over voltage preset 230-160V/380-500V Repress"Menu" key P A - 4 Loop preset 1-12Loops Repress"Menu" key Press" rs" key for 3s at the same time Repress"Menu" key for 3s P A - 5 Cutting threshold 0.70 ind-0.70eap Note m Signal initial P A - 6 phase 0 OR 180 Notel Save the preset parameters and enter into auto running state. Parameter adjustment Press" r "key parameters will increase. Press"s key parameters will decrease.

2. Steps for adjusting parameters under reactive power control mode Choose the preset parameter Press "Menu" key for 3s to make indicator lightof "Parameter preset" shine Parameter code code meaning Parameter range P A - 1 Target power factor 0.70ind-0.70cap Repress"Menu" key P A - 2 Delay preset 1-250 S Parameter adjustment Repress"Menu" key P A - 3 Over voltage.preset 230-260V/380-500V Repress"Menu" key P A - 4 Repress"Menu" key C 0 1 Repress"Menu" key C 0 2 Repress"Menu" key C - 12 Press"rs" key for 3s at the same time Repress"Menu" key for 3s CT transformation ratio preset - Capacitor capacity of number 1 loop Capacitor capacity of No. 2 loop I Capacitor capacity of No. 12 loop 50-5000 Notej 0-150.0Kvar Notek 0-150.0Kvar Notek 0-150.0Kva Notek P A - 6 Signal initial phase 0 or 180 Notel. Press"r" key parameters will increase. Press" s"key parameters will decrease. Save the preset parameters and enter into auto running state. User should carefully read the following annotation contents, especially the black letter. Note: 1. Under reactive power control mode, CT transformation ratio preset value is the numerator of transformation ratio of signal current transformer. If the transformation ratio of signal current transformer is 500/5A, the CT transformation ratio preset value is 500 other than 100. 2. Under reactive power control mode, the capacity parameter of the output loop that not connected to capacitor groups should be preset to "0", To the output loop with "0" preset capacity, the controller will not output signal control signal. 3. When the input voltage signal of controller and current signal are in the synonymous end state, user should adjust the parameter to "0". When they are not in the synonymous end state, user should adjust to "180". When the voltage signal and current signal sampling are correct and at the same time the controller hasn't input one set of capacitor group, the displayed power factor value is negative value. It can be judged that the voltage signal and current signal input to the controller are not in the synonymous end state. If the initial phase is "180", user should adjust it to "0". If it is "0", user should adjust it to "180". If one set of compensation device is finished installing, user should confirm whether the parameters are correct, otherwise it may cause the abnormal running for controller. 4. Under power factor control mode, cutting threshold parameter should exceed 0.02 of input threshold parameter. If user amends the cutting threshold parameter to the value less than +0.02, the input threshold value by mistake, parameter amendment procedure will automatically set the cutting threshold parameter to +0.05, the current input threshold parameter. 11.DISPLAY INSTRUCTION Over voltage state : If the indicator light of current menu shines frequently, which means the controller is working under over voltage cutting state. System voltage value is displayed. Cos f value : If 0.985 displays, it means the current power factor is lagging 0.985. If -.985 displays, it means the current power factor leads 0.985. Undercurrent state : C - - 0 display means undercurrent, the signal current is less than 60mA.

12.CONNECTING DIAGRAM Connecting diagram (Power Supply 440V) Tapping size : 113 x 113(mm) Ub. Uc voltage signal input terminal la In current signal input terminal V Common terminal of control output terminal LOAD P J16 1 2 3 2A J6 J1 11 12 13 10A A B C KM-PFR-S-08 cutout Dimension : 138x138mm 1,3 voltage signal input terminal 11, 13 In current signal input terminal 14 common terminal of control output terminal C16 C6 C1 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 If the contactor is 440V, connect P to B or C. If it is 220V, connect P to phase N. 13. FAILURE AND TROUBLESHOOTING During installing and using the controller, some easily ignored connection mistakes may cause abnormal running of compensation device. Following are several items of frequent failure phenomenon and its methods of resolution. 1. Control head panel is input to running and the indicator light shines, but the AC contactor doesn't switch on. The phenomenon is caused due to the coils of AC contactor haven't got the power or the power is extremely low. User should check whether the type of AC contactor conforms to the drawing, and the insurance in good condition or not, as well as the power common terminal of AC contactor and the output common terminal of controller are connected to the same line and the connecting line has disconnection or not. 2. Power factor changes abnormally or no change along with the input of capacitor. The former phenomenon was caused as the incorrect sampling of voltage or current signal. User should chiefly check signal sampling. The latter was caused due to the wrong position of signal current transformer, user must cover the current transformer to the place. the output of which can reflect the change of total load current. (Such as the bus bar of general cabinet) 3. General display of controller: C - - 0 phenomenon shows that the signal current input into the controller is too small ( less than 60mA) or caused by no current. User should calculate whether the transformation ratio of current transformer is reasonable. Current signal loop has disconnection or connected to other meters in serial or parallel or not. 4. One or several groups of capacitors never input (when input, but indicator light doesn't shine), the phenomenon only happens under reactive power control mode. Generally user haven't preset the capacity of capacitor or the preset data is too big when amending parameters, so user just preset the capacity of capacitor will be right.

5. The reactive power value that controller displays has great disparity with the actual value. Generally it is caused by the incorrect preset of the transformation ratio of current transformer. User should check the ratio of signal current transformer conform to the preset value or not. 6. The power factor value that controller displays has great disparity with the actual value. It may caused by the followings: a. Inconrect voltage or current signal sampling. b. Current signal exceeds 5.5A (Unreasonable choice of transformation ratio for current transformer). 7. The power factor value is always negative value when controller not inputting one group of capacitor groups. When user doesn't want to amend the initial phase. just exchange the current signal lines and connect. 8. Any problems that can't be solved personally, user can contact the local distributor or manufactory for technical consultation. MODEL NO. TEST CERTIFICATE This Test Certificate that warranty the product has been inspected and Tested in accordance with the published specifications. The instrument has been calibrated by using equipment which has already been calibrated to standards traceable to national standards. SERIAL NO. DATE: ISO 9001 REGISTERED QC KUSAM-MECO PASS WARRANTY Each KUSAM-MECO product is warranted to be free from defects in material and workmanship under normal use & service. The warranty period is one year(12 months) and begins from the date of despatch of goods. In case any defect occurs in functioning of the instrument, under proper use, within the warranty period, the same will be rectified by us free of charges, provided the to and fro freight charges are borne by you. This warranty extends only to the original buyer or end-user customer of a KUSAM-MECO authorized dealer. This warranty does not apply for damaged Ic s, fuses, disposable batteries, carrying case, test leads, or to any product which in KUSAM-MECO s opinion, has been misused, altered, neglected, contaminated or damaged by accident or abnormal conditions of operation or handling. KUSAM-MECO authorized dealer shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM-MECO. KUSAM-MECO s warranty obligation is limited, at option, free of charge repair, or replacement of a defective product which is returned to a KUSAM-MECO authorized service center within the warranty period. G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Tel.: 24124540, 24181649, 27750662, 27750292 Fax : 022-24149659 Email : kusam_meco@vsnl.net, sales@kusam-meco.co.in Website : www.kusamelectrical.com