WinMLS I very much like the convenience of the tool and how quickly measurements can be made - Christopher Pye, Integral Acoustics, Canada

Similar documents
PRODUCT DATA. DIRAC Room Acoustics Software Type Photo courtesy of Muziekcentrum Frits Philips, Eindhoven, The Netherlands

PRODUCT DATA. DIRAC Room Acoustics Software Type 7841

CLIO Pocket is Audiomatica's new Electro-Acoustical Multi-Platform Personal measurement system.

Impulse response. Frequency response

CLIO 10, by Audiomatica, is the new measurement software for the CLIO System. The CLIO System is the easiest and less expensive way to measure:

THE ANV MEASUREMENT SYSTEMS SOUND INSULATION TESTING SYSTEM INSTRUCTION MANUAL FOR FIELD TESTING OF WALLS, FLOORS & STAIRS

IE-35 & IE-45 RT-60 Manual October, RT 60 Manual. for the IE-35 & IE-45. Copyright 2007 Ivie Technologies Inc. Lehi, UT. Printed in U.S.A.

Measuring procedures for the environmental parameters: Acoustic comfort

n CLIO 12, by Audiomatica, is the newest measurement software for the CLIO System. The CLIO System is capable of measuring: n electrical networks n

ODEON APPLICATION NOTE ISO Open plan offices Part 2 Measurements

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Acoustic Measuring System

Real time spectrum analyser sound level meters

Airborne Sound Insulation

Transfer Function (TRF)

DESIGN OF VOICE ALARM SYSTEMS FOR TRAFFIC TUNNELS: OPTIMISATION OF SPEECH INTELLIGIBILITY

Balanced Armature Check (BAC)

STUDIO ACUSTICUM A CONCERT HALL WITH VARIABLE VOLUME

AXIHORN CP5TB: HF module for the high definition active loudspeaker system "NIDA Mk1"

APPLICATION NOTE MAKING GOOD MEASUREMENTS LEARNING TO RECOGNIZE AND AVOID DISTORTION SOUNDSCAPES. by Langston Holland -

PRODUCT DATA. PULSE Multichannel Sound Power Type 7748 Version 1.2

EFFECT OF STIMULUS SPEED ERROR ON MEASURED ROOM ACOUSTIC PARAMETERS

Validation of lateral fraction results in room acoustic measurements

ODEON APPLICATION NOTE Calculation of Speech Transmission Index in rooms

Measurement of weighted harmonic distortion HI-2

Digitally controlled Active Noise Reduction with integrated Speech Communication

NON-SELLABLE PRODUCT DATA. Order Analysis Type 7702 for PULSE, the Multi-analyzer System. Uses and Features

CR:247 Invictus. Portable Noise Monitor. Features. Features. Applications

m+p Analyzer Revision 5.2

Causes for Amplitude Compression AN 12

Measurement of Weighted Harmonic Distortion HI-2

Measuring Center 2.6 User Manual Software for sound signal analysis

PRODUCT DATA. Sound Intensity Calibrator Type 4297

INTERIM EUROPEAN I-ETS TELECOMMUNICATION December 1994 STANDARD

Acoustic Calibration Service in Automobile Field at NIM, China

ENGINEERING STAFF REPORT. The JBL Model L40 Loudspeaker System. Mark R. Gander, Design Engineer

Loudspeaker Test. Report

Analysis of reverberation times and energy decay curves of 1/12 octave bands in performance spaces considering musical scale

Measurement of Amplitude Modulation AN 6

NEW! XL2 EXELLINE HANDHELD AUDIO AND ACOUSTIC ANALYZER LESS NOISE. MORE SOUND. Sound Level Meter. Real Time Analyzer. FFT Analyzer.

SigCal32 User s Guide Version 3.0

Additional Reference Document

Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B. Application Note

The ArtemiS multi-channel analysis software

Power Analysis Application Module DPO4PWR MDO3PWR Datasheet

Product Description. Features. Applications

EUROPEAN pr I-ETS TELECOMMUNICATION June 1996 STANDARD

SIA Software Company, Inc.

3D Distortion Measurement (DIS)

Fractional Octave Analysis and Acoustic Applications

Vibration Transducer Calibration System

Digital Signal Processing Audio Measurements Custom Designed Tools. Loudness measurement in sone (DIN ISO 532B)

How To... Commission an Installed Sound Environment

Univox FSM 2.0. Multitone Field Strength Measurement Microprocessor controlled. User Guide. FSM 2.0, Part No

Aurora 4 is a complete system for measuring electro-acoustical impulse responses and performing auralization through headphones and/or loudspeakers.

WHAT ELSE SAYS ACOUSTICAL CHARACTERIZATION SYSTEM LIKE RON JEREMY?

Measurement at defined terminal voltage AN 41

3D Intermodulation Distortion Measurement AN 8

Classic Active Monitoring Series. Catalogue 2018

TBM - Tone Burst Measurement (CEA 2010)

SC160. Integrating Sound Level Meter Real time frequency Analyser* in Octave Band

SGN Audio and Speech Processing

Audio Analyzer R&S UPV. Up to the limits

SigCalRP User s Guide

NEW! XL2 EXELLINE HANDHELD AUDIO AND ACOUSTIC ANALYZER LESS NOISE. MORE SOUND. Sound Level Meter. Real Time Analyzer. FFT Analyzer.

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

Monitor Setup Guide The right monitors. The correct setup. Proper sound.

Since the advent of the sine wave oscillator

Analysis of room transfer function and reverberant signal statistics

Convention e-brief 310

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features

Oscilloscope (dual channel, xy, time division, trigger); log, lines, bar, octaves band analysis 1/3, 1/6, 1/9, 1/12, 1/24);

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Production Noise Immunity

IMPULSE RESPONSE MEASUREMENT WITH SINE SWEEPS AND AMPLITUDE MODULATION SCHEMES. Q. Meng, D. Sen, S. Wang and L. Hayes

Tutorial 1: Install Forecaster HD (Win XP, Vista, 7, 8)

What you Need: Exel Acoustic Set with XL2 Analyzer M4260 Measurement Microphone Minirator MR-PRO

Rub & Buzz Detection with Golden Unit AN 23

The effects of the excitation source directivity on some room acoustic descriptors obtained from impulse response measurements

Principles of Audio Web-based Training Detailed Course Outline

Measuring 3rd order Intercept Point (IP3 / TOI) of an amplifier

Definition Install iw63 DC

Laboratory Assignment 2 Signal Sampling, Manipulation, and Playback

VX 8.2. Product Description. Features. Applications

Characterize Phase-Locked Loop Systems Using Real Time Oscilloscopes

Holland, KR, Newell, PR, Castro, SV and Fazenda, BM

Headphone Testing. Steve Temme and Brian Fallon, Listen, Inc.

Technical Documentation

Measuring impulse responses containing complete spatial information ABSTRACT

Measurement System for Acoustic Absorption Using the Cepstrum Technique. Abstract. 1. Introduction

SIA-Smaart Schools & Applications Seminars

Ulteé Audiotechnik. Professional Audio Measurement. User s Manual

Application Note: Headphone Electroacoustic Measurements

ARTA. User Manual. Program for Impulse Response Measurement and Real Time Analysis of Spectrum and Frequency Response. Version

Realtime auralization employing time-invariant invariant convolver

Case study for voice amplification in a highly absorptive conference room using negative absorption tuning by the YAMAHA Active Field Control system

STR INTEGRATED AMPLIFIER POWERING THE FUTURE OF AUDIO USBDAC INTEGRATED AMPLIFIER INTEGRATED AMPLIFIER

FFT Spectrum Analyzer

Proceedings of Meetings on Acoustics

Transcription:

WinMLS 2004 What is WinMLS? WinMLS is a sound card based software for high quality audio, acoustics and vibrational measurements using your PC/laptop. The fact that it is sound card based, makes it possible for you to select between a large and growing number of hardware solutions. We sell hardware solutions tested for different applications. Your software is great! Magnus Wahlberg, Denmark Do you need a TOY or a TOOL? Be aware that fancy looking measurement software may give wrong or bad results. WinMLS has been compared and verified with excellent results in several round robins and seminars. If you are looking only for a TOY with fancy looking graphs, skins and buttons, WinMLS may not be the best solution for you. If you are looking for the most efficient and accurate ways of performing your measurements, please consider WinMLS. In practice, every measurement software show very different behavior, according to the external (roomnoise-hardware) conditions. WinMLS manages to perform measurements under all (reasonable) circumstances. -Thalis Menexelis, Athen, Greece Is measurement duration important? WinMLS supports the latest measurement methods that ensures that the measurement duration is kept to a minimum. In addition, not tedious procedures is required to start a measurement. I very much like the convenience of the tool and how quickly measurements can be made - Christopher Pye, Integral Acoustics, Canada Who is it for? WinMLS is for experts and non-experts. It already has hundreds of professional users in the audio and acoustics consulting business, but it is also aimed at non-professional users, such as home audiophile enthusiasts and students. This is possible because of its ease of use, low-cost personal license and no need for specialized hardware. I have to say that I am very pleased with the programme and use it a lot now - Peter Mapp, expert UK I use WinMLS2000 personal version with pleasure - Alain Pouillon-Guibert, France What makes it user friendly? For the most common application there are setups with pre-defined settings. There is a wizard feature that will guide you step-by-step on how to use the setup. Why should you purchase WinMLS? Our policy is to provide the best performance for the lowest price in the marked. If you should find a another system you feel has a better performance/price for your type of application, please contact us and we will try to beat this price. We try the best we can to make our users satisfied. The technical support is superb and very timely. - Sunil Bharitkar, PhD California Your customer service is fantastic! Ed Hatke Cincinnati, Ohio FREE Evaluation: From www.winmls.com you can download WinMLS and register for a FREE 30 days evaluation.

Applications Typical WinMLS applications are: Sound system calibration Room acoustics Building acoustics Loudspeaker measurements Distortion/RubNbuzz measurements Production line testing (microphones and loudspeakers) Concert hall acoustics Musical acoustics Hi-Fi and home theater system calibration Speech parameters (STI, RASTI, etc...) Noise measurements Research and Education Key properties reliable - WinMLS has been benchmarked and tested with excellent results in several international round robins on room acoustical measurements already in use WinMLS has been sold since 1997 and has hundreds of professional users worldwide portability - use your laptop to perform your acoustical measurement simplify writing reports no need to transfer data, just cut-and-paste from WinMLS to the reportwriting software (e.g. MS Word and Excel) user friendly interface can be customized and advanced settings can be hidden for the nonadvanced user flexible advanced settings can be accessed effective support support directly from the developers is available for professional customers (telephone and e-mail). We can help you getting started over the telephone. low price compared to the available features simple procedure to upgrade to a multi-channel (>2 channel) measurement system) new features are constantly added, our policy is to offer the best of the modern measurement methods and listen to requests from our users we also deliver hardware so the customer may order a complete measurement system Key features Measurement modes Swept sine (recommended for impulse response measurements) External source (pink noise, music, etc...) MLS (recommended for speech parameter measurements) Sinusoid Scope (no excitation signal) Pseudonoise (pink and white noise) Plot types WinMLS measures data in time domain. However, the measurement result can be presented as any of the following: Time data / Impulse response (echogram) Integrated time data / Step response

Energy-time curve Schroeder curve Spectrum / Frequency response Phase response Group delay Room Acoustics Parameters Parameters (dba, dbc, THD etc...) Waterfall (time and frequency domain combined) General parameters Sound level, db, dba, dbb, dbc Total harmonic distortion, THD Separate harmonic distortion component Sound reduction, R w Impact sound level, L nw Sound insulation parameters are calculated according to the ISO 717-1 and 717-2 (1997) standard. Room acoustics parameters Reverberation time (RT60), T30 Early decay time (RT60), ETD User defined reverberation time (RT60), Txx Definition, D50 Clarity, C50, C80 Center time, Tc Support, ST1 Speech transmission index, STI, STIrMale, STIrFemale, RASTI and %ALcons (STI-based) Interaural crosscorrelation, IACC Lateral fraction, LF Strength, G Late lateral strength, LG Room acoustical parameters are calculated according to the ISO 3382 (1997) standard. Noise detection and compensation is included for all parameters, and the calculations are tested against international benchmarks. Speech measurements (STI and RASTI) include octave band corrections for background noise in compliance with IEC 60268-16 standard. Digital filtering in octave and 1/3-octave bands is performed according to the IEC 1260 (1995) standard. Backwards filtering for 1/3-octave band reverberation time is included for improved accuracy. Parameters can also be calculated in double-octaves or without filtering. General specifications Operative system: Windows 95/98/ME/NT/2000/XP Portable and light-weight measuring equipment, e.g. using blank pistol and laptop PC to measure reverberation time. Flexible hardware, most soundcards are supported. More than 50 sound cards have been tested and are documented. Digigram VXpocket PCMCIA sound card is currently recommended for high-end portable measurement system

Input and output levels can easily be set using the built-in software mixer. The mixer levels can easily be calibrated Calibration of hardware allows for measurement of absolute levels such as voltage and SPL. Calibration of microphone using either calibrator or nominal microphone sensitivity 1 or 2 channel measurements in standard version, but can be upgraded to 24 channels with sampleaccurate synchronization (hardware dependent). Supports selection from multiple sound cards High frequency range. Sampling rates up to 96 khz in standard version. Special version is able to measure up to 100 khz using sampling rate 215 khz (sound card dependent) High signal to noise ratio, using internally generated MLS loudspeaker signals with optional low-frequency boosting or speech filters Influence of measurement system can be subtracted Auto-name generator for saving data Uses standard WAV, ASCII, MLSSA TIM files in addition to the WinMLS WMB binary file format Initial time delay (distance from loudspeaker to microphone) can be measured sample-accurate with all supported sound cards Toolbars can be removed from the user interface to maximize the screen area used to display the plot(s). Data can be exported, or plotted using WinMLS powerful graphics All important parameters are user configurable through a measurement setup and a post-processing setup. User friendly using default setups (all settings saved in setup files that can easily be restored) Flexible, easily customized user interface, many useful options for the advanced user Graphically displays parameters from multiple measurements and statistics such as mean, min, max and standard deviation Graphs can easily be printed, saved as text files or copied to the clipboard for use in reports Unlimited number of plot-types can be viewed simultaneously, for example the windowing of the impulse response can be changed and the resulting change in the frequency response is immediately displayed simultaneous. Plot features include auto-refreshing and viewing active measurement curve solo. Many features for comparing several curves in a plot. WinMLS is not limited to simple overlays. Flexible statistic treatment of data. Ultra-fast harmonic distortion (THD) measurements using swept sine in addition to standard method using sinusoid. Sound insulation measurements. Measurement modes: Swept sine, MLS, sinusoid, user defined excitation and scope, pink and white noise. Plot types: Time data (impulse response), step response, energy-time curve, Schroeder curve, frequency response/spectrum, phase response, group delay, waterfall, room acoustics parameters, levels Full and third-octave band analysis, dba, dbb, dbc and waterfall plots. Background WinMLS is aimed at professionals, but also for non-commercial users, such as home audio enthusiasts and students. This is possible because of its ease of use, low-cost personal license and no need for specialized hardware. Note that the personal licenses are allowed for personal and class-room usage only, and not for commercial usage or research. We have professional users worldwide. For example, Genelec and their distributor network are using our software for measuring frequency response when installing monitors in studios. Some other users are PTB - Germany, Aercoustics Engineering Ldt (Dr. John O'Keefe) - Canada, Seas AS - Norway, National Research Counsil - Canada, Akustikon - Sweden, Duran Audio - the Nederlands and Peter Mapp - England. Feedback and wishes from our customers have lead to the following features in WinMLS 2004: User friendly interface with customizable charts for professional presentations. Works on most sound cards,

professional hardware portable and stationary systems may be purchased from us. Benchmarked and tested against and compatibility with other high-quality measurement systems.