Agilent 8761A/B Microwave Switches

Similar documents
Agilent 8761A/B Microwave Switches

Agilent 8762F Coaxial Switch 75 ohm

Agilent 84904, 6, 7K/L Programmable Step Attenuators

Keysight 8762F Coaxial Switch 75 ohm

Advanced Test Equipment Rentals ATEC (2832)

Agilent 87104/87106A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

Agilent NFA Noise Figure Analyzer


Agilent 87204/87206A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

Techniques to Achieve Oscilloscope Bandwidths of Greater Than 16 GHz

Solar Array Simulation System Integration

Agilent N9342C Handheld Spectrum Analyzer (HSA)

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Agilent N9310A RF Signal Generator. All the capability and reliability of an Agilent instrument you need at a price you ve always wanted

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

When is it Time to Transition to a Higher Bandwidth Oscilloscope?

N2820A/21A High-Sensitivity, High Dynamic Range Current Probes

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent U9391C/F/G Comb Generators

Solutions for Solar Cell and Module Testing

Agilent InfiniiMax III probing system

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Agilent U9397A/C FET Solid State Switches (SPDT)

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Agilent Spectrum Visualizer (ASV) Software. Data Sheet

Educator s Oscilloscope Training Kit for the InfiniiVision 2000 & 3000 X-Series

Agilent NFA Noise Figure Analyzer

Agilent N9340B Handheld Spectrum Analyzer (HSA)

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Agilent U1730C Series Handheld LCR Meters

Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Keysight Technologies 87104/6D Multiport Electromechanical Coaxial Switches

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Agilent 87075C Multiport Test Set

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Agilent NFA Noise Figure Analyzer

Agilent 8766/7/8/9K Microwave Single-Pole Multi-Throw Switches

MXG X-Series Signal Generator N5183B Microwave Analog

Educator s Oscilloscope Training Kit for Agilent InfiniiVision X-Series Oscilloscopes

Agilent 2-Port and 4-Port PNA-X Network Analyzer

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

Agilent J7211A/B/C Attenuation Control Units

Agilent N4916B De-emphasis Signal Converter

Keysight Technologies 87222C/D/E Coaxial Transfer Switches

Keysight Technologies Waveguide Power Sensors. Data Sheet

Agilent N6780 Series Source/Measure Units (SMUs) for the N6700 Modular Power System

N9051A Pulse Measurement Software

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Agilent E8257D PSG Microwave Analog Signal Generator

Agilent 87405B. Preamplifier 10 MHz to 4 GHz. Technical Overview. Features. Benchtop/General Purpose Use

MXG Analog Signal Generator Express Configurations

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

Agilent N9320B RF Spectrum Analyzer

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Agilent N9344C/N9343C/N9342C Handheld Spectrum Analyzer (HSA)

Keysight Technologies USB Preamplifiers

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Keysight Technologies U9391C/F/G Comb Generators. U9391C (10 MHz to 26.5 GHz) U9391F (10 MHz to 50 GHz) U9391G (10 MHz to 67 GHz) Technical Overview

N2750A/51A/52A InfiniiMode Differential Active Probes

Keysight Technologies 85072A 10-GHz Split Cylinder Resonator. Technical Overview

Essential Capabilities of EMI Receivers. Application Note

InfiniiMax III probing system

Keysight Technologies Achieving Accurate E-band Power Measurements with E8486A Waveguide Power Sensors. Application Note

Agilent E4438C/E8267D Option 422 Scenario Generator for GPS

Process Control Calibration Made Easy with Agilent U1401A

Evaluating Oscilloscopes for Low-Power Measurements

Introduction. Part 1. Introduction...2

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

Agilent MXG Signal Generators

Keysight HMMC-1002 DC 50 GHz Variable Attenuator

Agilent Nonlinear Vector Network Analyzer (NVNA)

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

A Time-Saving Method for Analyzing Signal Integrity in DDR Memory Buses

Agilent Maximizing Measurement Speed Using P-Series Power Meters

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight Technologies U9400A/C Solid State FET Transfer Switches

EM Insights Series. Episode #1: QFN Package. Agilent EEsof EDA September 2008

Keysight Technologies Making Current-Voltage Measurement Using SMU

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview


Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

Keysight E5063A ENA Series Network Analyzer

Keysight Technologies mm-wave Source Modules from OML, Inc. for PSG Signal Generators. Technical Overview

Transcription:

Agilent 8761A/B Microwave Switches Technical Overview Product Description The Agilent Technologies 8761A and 8761B are single-pole, double-throw coaxial switches with excellent electrical and mechanical characteristics for 50-ohm transmission systems operating from dc to 18 GHz. Both switches feature broadband operation, long life, low SWR, excellent repeatability, and magnetic latching solenoids. The 8761A and 8761B switches are small and lightweight, making them ideal for applications where space is limited. Because of their versatility and excellent electrical performance, they are well suited for automated testing and systems applications. The A version is for 12 to 15 VDC operation, and the B version uses 24 to 30 VDC solenoid drive voltage. Electrical Performance These switches have proven reliable in Agilent microwave instrumentation, special purpose test equipment, and many other applications. They have been optimized for broadband operation, high isolation, minimal insertion loss, low SWR, and high repeatability. High Isolation High port-to-port isolation is important in applications requiring wide dynamic range such as receiver sensitivity testing. The RF structure designs used for these switches yield the high isolation shown in Figure 1. Broadband (dc to 18 GHz) User specified connectors (over 250 possible combinations) Excellent repeatability (typically 0.03 db after 1,000,000 cycles) Environmentally rugged The Agilent 8761A/B Series can be custom configured with any combination of Type-N, SMA, and precision 7-mm connectors, thus enabling the user to custom design a connector arrangement and eliminate the need for connector adapters.

Low Insertion Loss Low insertion loss is very desirable in many applications where the user needs to minimize the loss of signal power. Using miniature gold-plated contacts, these switches offer the low insertion loss shown in Figure 2. Low SWR Low SWR is an important characteristic for switches because transmission line mismatches degrade the measurement system accuracy. Through the use of edge line design and precision machining, these switches offer the excellent SWR shown in Figure 3. High Repeatability For measurement system applications, repeatability of the switched connection is a key factor in minimizing measurement error. The excellent repeatability of these switches (typically 0.03 db after one million switching operations) has been achieved by employing gold-plated contacts and edge line design for the transmission line. This unique design feature of switching only the center conductor eliminates high friction sliding contacts, and results in long life and highly repeatable measurements. The 8761 is a break before make switch controlled by a magnetic latching solenoid. Solenoid voltages of 12 and 24 volts are available. To change the state of the switch requires a reversal of the voltage polarity for at least 20 milliseconds (see Figure 4). Once switched, the solenoid is latched by strong permanent magnets. Figure 1. Typical port-to-port isolation Figure 2. Typical insertion loss Figure 3. Typical SWR for SMA connection Typical Agilent 8761A Driver Circuit 1 Figure 5 shows a typical driver circuit which uses a clock driver to control the 8761A switch. A TTL Hl input to the circuit results in +V at point Q and V (ground) at point R. Conversely, a TTL LO input results in V (ground) at point Q and +V at point R. Internal diodes in the DS0026 suppress inductive voltage spikes. Figure 4. To connect ports 2 and C (as shown) requires the indicated solenoid voltage for at least 20 milliseconds. Reversing the polarity of the solenoid voltage connects ports 1 and C. *National Semiconductor part numbers, also supplied by other vendors. Figure 5. Typical 8761A driver circuit 1. The switch solenoids are not designed to withstand continuous drive current due to excessive coil heating. To maximize switch life, Agilent recommends actuation using only pulsed drive. In this case, the pulse duration must be at least 20 milliseconds long, in order to ensure that the switch will fully latch. Also, Agilent recommends using back-to-back zener diodes connected in parallel with the switch solenoid, in order to minimize excessive fly-back currents through the solenoid. Refer to Figures 4 and 5 to see recommended connection configurations. 2

Connector Information The Agilent 8761A/B switches are available with any combination of SMA, Type-N, precision 7-mm (mates with APC-7), and 50-ohm termination. This feature enables the user to custom design a single switch or multiple switch configuration for a specific application. By properly specifying connector options, switch trees can be configured to provide single-pole multi-throw as well as multi-pole multithrow functions, all without the need for interconnecting cables. To specify connector options, refer to the ordering example. Mechanical Information Three versions of the precision 7-mm connector are available on the 8761A/B which mate with the APC-7 connector, but differ slightly from the standard APC-7 to conserve space. One of these versions (option 102, 202, or 302) has a fixed threaded sleeve and the other (option 103, 203, or 303) has a coupling nut. The third precision 7-mm connector (option 104, 204, or 304) is designed to be used with a 0.250-in. outer diameter, semirigid coaxial cable. This connector is the same as the 7-mm option 102, 202, or 302 connector described above, with the exception of the center conductor which is female and accepts the center conductor of the semi-rigid coax. The fittings for a compatible connector on the semi-rigid coax are shown in Figure 6. Part Number 1. Cable Terminator 08742-2028 2..375-32 Clamp Nut 0590-0035 3. Cable Coupling Nut 08740-2081 4. Cable Washer 5000-8676 5. Semi-rigid Coax Cable, UT-250* * Uniform Tubes Inc., Collegeville, PA. Dimensional drawings for items 1 through 4 above are available upon request. Figure 6. Cable assembly to mate with the 7-mm connector for UT-250 cable (option code 4) Connector Options Agilent 8761A/B Connector Options Connector Type Dimension a mm (in.) 100, 200, 300 Type-N Female 13.72 (0.540) 101, 201, 301 Type-N Male 19.79 (0.775) 102, 202, 302 7-mm Threaded Sleeve (APC-7) 9.27 (0.365) 103, 203, 303 7-mm Coupling Nut (APC-7) 11.94 (0.470) 104, 204, 304 7-mm for UT-250 Coax 9.27 (0.365) 105, 205, 305 SMA Female 16.13 (0 @ 635) 106, 206, 306 SMA Male 17.15 (0.675) 107, 207 50-ohm Termination 2 30.5 (1.20) Replaceable Parts: Refer to the Agilent 8761A/B Operating Note. 2. Option 107, 207 available on port 1 or port 2 only. 3

Specifications Switch Type Frequency Range Insertion Loss Isolation Characteristic Impedance Single-pole double-throw, break before make, latching solenoid DC to 18 GHz DC to 12.4 GHz: <0.5 db DC to 18.0 GHz: <0.8 db DC to 12.4 GHz: >50 db DC to 18.0 GHz: >45 db 50 Ω SWR 1 Connector Type Type N DC to 12.4 GHz: 1.20 DC to 18.0 GHz: 1.25 7-mm (APC-7) 1 DC to 12.4 GHz: 1.15 DC to 18.0 GHz: 1.20 3-mm (SMA) DC to 12.4 GHz: 1.30 DC to 18.0 GHz: 1.35 50 ½ Load SWR degraded by 0.05 when used with above connector types. Ordering Information To order the Agilent 8761A/B switch, connector configuration and solenoid voltage must be specified as shown in the ordering example below. Connector Options Connector Type 100, 200, 300 Type-N Female 101, 201, 301 Type-N Male 102, 202, 302 7-mm Threaded Sleeve (APC-7) 2 103, 203, 303 7-mm Coupling Nut (APC-7) 3 104, 204, 304 7-mm for UT-250 Coax 105, 205, 305 SMA Female 106, 206, 306 SMA Male 107, 207 50-ohm Termination Input Power Rating Life Repeatability Switching Speed 10 watts average, 5 k watts peak (2 watts average, 100 watts peak with option 7, 50-ohm termination) >1,000,000 switchings 0.03 db after 1,000,000 switchings (Typical) Maximum: 50 milliseconds Coil Voltage 8761A: 12 V (12 to 15 V) 8761B: 26 V (24 to 30 V) Switching Current Coil Impedance 8761A: 80 ma @ 12 V 8761B: 65 ma @ 26 V 8761A: 150 Ω, 90 mh 876IB: 400 Ω, 300 mh Environmental Qualifications Operating Temp. 25 C to +70 C Humidity 95% RH, +40 C, 5 days Vibration 0.03, 10 to 55 Hz Shock 30 G s, 11 ms Weight Net: 140 to 220 gm (5 to 8 oz) Shipping: 220 to 300 gm (8 to 11 oz) 1. 8761A/B SWR specifications apply when all ports are of the same connector type. For mixed connector types, the larger of the two SWR s applies. Type-N connector SWR specifications apply to 7-mm for UT-250 Coax connectors (option 104, 204, or 304). 2. Either option will connect to a standard, sexless, 7-mm connector. To daisy-chain two 8761A s you must use one option 102, 202, or 302 and one option 103, 203, or 303 on the two mating connectors. If you have two of the same options, you will need to use a cable with two standard 7-mm connectors. 4

www.agilent.com www.agilent.com/find/mta Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. Agilent Advantage Services is committed to your success throughout your equipment s lifetime. We share measurement and service expertise to help you create the products that change our world. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair, reduce your cost of ownership, and move us ahead of your development curve. www.agilent.com/find/advantageservices www.agilent.com/quality For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Brazil (11) 4197 3500 Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 United Kingdom 44 (0) 118 9276201 For other unlisted Countries: www.agilent.com/find/contactus Revised: October 14, 2010 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 1995, 2000, 2002, 2009-2011 Printed in USA, June 7, 2011 5952-1911