ECE 445 Fall 2017 Project Proposal. Recovery-Monitoring Knee Brace

Similar documents
High Frequency Ceramic Solutions

6.101 Introductory Analog Electronics Laboratory

MAXREFDES73#: WEARABLE, GALVANIC SKIN RESPONSE SYSTEM

Group #17 Arian Garcia Javier Morales Tatsiana Smahliuk Christopher Vendette

ECE 480 Design Team 6 Electrocardiography and Design

ENGR 499: Wireless ECG

Introduction. Theory of Operation

Lab: Using filters to build an electrocardiograph (ECG or EKG)

In this lecture, we will look at how different electronic modules communicate with each other. We will consider the following topics:

Noninvasive PoC Anemia Detection Device

P08050 Testing Strategy Document

Wireless Music Dock - WMD Portable Music System with Audio Effect Applications

Power and ground is applied to the nrf401 Loop Module via connector footprint J1. Voltage range on this input must be restricted to +2.7V to +5.25V.

Using the VM1010 Wake-on-Sound Microphone and ZeroPower Listening TM Technology

Dedan Kimathi University of technology. Department of Electrical and Electronic Engineering. EEE2406: Instrumentation. Lab 2

RF4432 wireless transceiver module

Radar Shield System Design

EMG Sensor Shirt. Senior Project Written Hardware Description April 28, 2015 ETEC 474. By: Dylan Kleist Joshua Goertz

EE 230 Experiment 10 ECG Measurements Spring 2010

WT11I DESIGN GUIDE. Monday, 28 November Version 1.1

802.11g Wireless Sensor Network Modules

Keywords: GPS, receiver, GPS receiver, MAX2769, 2769, 1575MHz, Integrated GPS Receiver, Global Positioning System

Training Schedule. Robotic System Design using Arduino Platform

An IoT Based Real-Time Environmental Monitoring System Using Arduino and Cloud Service

DNT24MCA DNT24MPA. Low Cost 2.4 GHz FHSS Transceiver Modules with I/O. DNT24MCA/MPA Absolute Maximum Ratings. DNT24MCA/MPA Electrical Characteristics

For Immediate Release. For More PR Information, Contact: Carlo Chatman, Power PR P (310) F (310)

Catalog

A Solar-Powered Wireless Data Acquisition Network

White Paper Kilopass X2Bit bitcell: OTP Dynamic Power Cut by Factor of 10

HUMAN BODY MONITORING SYSTEM USING WSN WITH GSM AND GPS

ECE 445 Fall RFI Detector Design Document

Analog to Digital Conversion

Name Kyla Jackson, Todd Germeroth, Jake Spooler Date May 5, 2010 Lab 3E Group 3 Experiment Title Project Deliverable 3

Characteristic Sym Notes Minimum Typical Maximum Units Operating Frequency Range MHz Operating Frequency Tolerance khz

ECE 511: FINAL PROJECT REPORT GROUP 7 MSP430 TANK

Revision History. Rev. No Issued Date Page Description Summary. V Initial Release

Lost Object Search Technology

SNIOT702 Specification. Version number:v 1.0.1

RF4463F30 High Power wireless transceiver module

The report presents the functionality of our project, the problems we encountered, the incurred costs and timeline for the project development.

RF NiceRF Wireless Technology Co., Ltd. Rev

Multipurpose Iron Man Glove & Moveable Platform

RF4432F27 Catalog

GFT bit High Speed Digitizer

EECE Circuits and Signals: Biomedical Applications. Lab ECG I The Instrumentation Amplifier

Beacon Indoor Navigation System. Group 14 Andre Compagno, EE. Josh Facchinello, CpE. Jonathan Mejias, EE. Pedro Perez, EE.

Frequency 434=434MHz 868=868MHz 915=915MHz

RF Comparator XT06 DELIVERABLES. Datasheet GDSII database Customer support

University of Pittsburgh

ULP Wireless Technology for Biosensors and Energy Harvesting

Cypress Robot Kit Final Report

COLLECTING USER PERFORMANCE DATA IN A GROUP ENVIRONMENT

Characteristic Sym Notes Minimum Typical Maximum Units Operating Frequency Range MHz. RF Chip Rate 11 Mcps RF Data Rates 1, 2, 5.

Hydra: A Three Stage Power Converter

Florida Atlantic University Biomedical Signal Processing Lab Experiment 2 Signal Transduction: Building an analog Electrocardiogram (ECG)

Persistence of Vision LED Sphere

Analog Circuits and Systems

Datasheet. Bluetooth Smart Module. Pacwave Bluetooth Smart (BLE) Module DESCRIPTION FEATURES

High Level Design Group: RF Detection Group Members: Joey Py e, André Magill, Shane Ryan, John Docalovich, Zack Bennett Advisor: Dr.

Characteristic Sym Notes Minimum Typical Maximum Units Operating Frequency Range MHz Operating Frequency Tolerance khz

Designing with STM32F3x

EE445L Fall 2014 Quiz 2A Page 1 of 5

REAL-TIME WIRELESS ECG AND ITS SIGNAL DISPLAY ON LABVIEW

5-Channel LiPo-Cell Electronic Load Tester Kit (LELTx5) PART NO

11 Counters and Oscillators

AERO2705 Space Engineering 1 Week 7 The University of Sydney

WEARABLE WIRELESS BODY AREA NETWORK

DNT2400. Low Cost 2.4 GHz FHSS Transceiver Module with I/O

1. Introduction...Page Scope...Page Bluetooth Low Energy Wireless sensor nodes...page 2

Linear Integrated Circuits

DESIGN AND IMPLEMENTATION OF EMG TRIGGERED - STIMULATOR TO ACTIVATE THE MUSCLE ACTIVITY OF PARALYZED PATIENTS

DNT90MCA DNT90MPA. Low Cost 900 MHz FHSS Transceiver Modules with I/O

common type of cardiac diseases and may indicate an increased risk of stroke or sudden cardiac death. ECG is the most

Prototype Testing Lab Results for INA116 Instrumentation Amplifier

PORTABLE ECG MONITORING APPLICATION USING LOW POWER MIXED SIGNAL SOC ANURADHA JAKKEPALLI 1, K. SUDHAKAR 2

A Closed-Loop System to Monitor and Reduce Parkinson s Tremors

ADVANCED EMBEDDED MONITORING SYSTEM FOR ELECTROMAGNETIC RADIATION

NEWS RELEASE IMEC REPORTS TWO WIRELESS PLATFORMS FOR BIOMEDICAL MONITORING

Review on Configurable and Low-Power Mixed Signal SOC for Portable ECG Monitoring Applications

Spectrum Detector for Cognitive Radios. Andrew Tolboe

Senior Design I. Fast Acquisition and Real-time Tracking Vehicle. University of Central Florida

AN4392 Application note

ECE 477 Digital Systems Senior Design Project Rev 8/09. Homework 5: Theory of Operation and Hardware Design Narrative

SmartFusion csoc: Enhancing Analog Front-End Performance Using Oversampling and Fourth- Order Sigma-Delta Modulator

Lecture 14 Interface Electronics (Part 2) ECE 5900/6900 Fundamentals of Sensor Design

ISSN: [Pandey * et al., 6(9): September, 2017] Impact Factor: 4.116

How to Monitor Sensor Health with Instrumentation Amplifiers

Lecture 1, Introduction and Background

S112 SoftDevice. SoftDevice Specification. v _190 v1.0 /

PTT- Z or PTT-U PUSH-TO-TALK Specification

DISCONTINUED. Modulation Type Number of RF Channels 15

Normal Oscillator Behavior (Device A) Figure 1. Normal Oscillator Behavior (Device A) ft = f0 1 + TC1 T T0

Laboratory Activities Handbook

DANGER DETECTING HEADPHONES

Hello, and welcome to this presentation of the STM32L4 comparators. It covers the main features of the ultra-lowpower comparators and some

Datasheet DS0011 AM093 Wireless Meter-Bus Dual Band 169/868MHz Narrowband Modem Advance Information Production Status Production

AN4378 Application note

Figure 1. C805193x/92x Capacitive Touch Sense Development Platform

Massachusetts Institute of Technology MIT

A wireless, ultra-portable oscilloscope with impressive specs debug circuits in their natural environment.

Transcription:

ECE 445 Fall 2017 Project Proposal Recovery-Monitoring Knee Brace Team #40 Locker D10 Members: Dennis Ryu [dryu3], Dong Hyun Lee [dlee134], Jong Yoon Lee [jlee642] TA: Dongwei Shi [dshi9] 18 Sept 2017 (Mon) 1

Contents 1. INTRODUCTION a. Objective....3 b. Background 3 c. High-Level Requirements List. 3 2. DESIGN a. Block Diagram... 4 b. Physical Design.4 c. Block Requirements & Functional Overview.... 5 d. Risk Analysis.8 3. ETHICS AND SAFETY 8 4. Appendix a. Physical Design Pictures...9 2

1. Introduction [1.a] Objective Thanks to modern technology, it is easy to encounter a wide variety of wearable fitness devices such as Fitbit and Apple Watch in the market. Such devices are designed for average consumers who wish to track their lifestyle by counting steps or measuring heartbeats. But it is rare to find a product for the actual patients who require both the real-time monitoring of a wearable device and the hard protection of a brace. Personally, one of our teammates ruptured his front knee ACL and received reconstruction surgery a few years ago. After ACL surgery, it is common to wear a knee brace for about two to three months for protection from outside impacts, fast recovery, and restriction of movement. For a patient who is situated in rehabilitation after surgery, knee protection is an imperative recovery stage, but is often overlooked. One cannot deny that a brace is also cumbersome to put on in the first place. There should be a viable alternative for such people in need. [1.b] Background With that said, our group aims to make a wearable device for people who require a knee brace by adding a health monitoring system onto an existing knee brace. The fundamental purpose is to protect the knee, but by adding a monitoring system we want to provide data and a platform for both doctor and patients so they can easily check the current status/progress of the injury. A feedback system will notify the wearer when the brace needs to be more tightly bound, and remind via. mobile interface when not worn for extended periods of time. Because the brace should also provide useful information for a professional looking over the patient, heat and EMG sensors placed on the inside of the brace will stream data to a mobile device via. Bluetooth. Marketable aspects include a minimal change in the overall weight of the brace, and the small but sufficiently ample lifespan of the battery we will be using as our power supply. [1.c] High-Level Requirements List Brace must be able to stream data continuously for a 48-hour period EMG sensors must determine a threshold for too much muscle movement Pressure sensors must determine a threshold for a snug fit 3

2. Design [2.a] Block Diagram Our monitoring devices require four logical blocks to operate. In the heart of the operation, we need the control unit to orchestrate the analog to digital conversion of the ECG, temperature, and pressure signals while sending the sampled data to the host device in real-time. We will have an analog circuit unit that will filter and correctly amplify the analog signal obtained from the sensors. The Power unit will deliver regulated power from the battery source to both the control unit and the analog circuit unit. Lastly, we will have the host unit that will receive the raw digital data and go through an intensive signal processing process step to deliver a meaningful information to the user. The host unit will also be in charge of spending user data to the cloud periodically for history logs that can be used later for further analysis. [2.b] Physical Diagram *See Appendix A 4

[2.C] Block Requirements & Functional Overview 2.C.1 Control Unit It is going to be the main module of our project device. It has to be a device that can collect all of our bio-signals (pressure, temperature, ECG) from the analog circuit, which means it should have an analog-to-digital converter. Because It is hard to do all the required signal processing on the chip, we need a System-on-Chip (SoC) that has a bluetooth module inside to communicate with the host device. Also, It has to consume low power.. 2.C.1.1 nrf52832 SoC The nrf52 SoC embeds a powerful yet low-power ARM Cortex -M4 processor with a 2.4 GHz RF transceiver. With the 2.4 GHz RF transceiver, it has the capability to use standard low-energy wireless protocols such as ANT and BLE. This makes the chip particularly appealing to low-power applications such as ours. The SoC is also packed with such peripherals that will enable us to achieve our goals and though satisfying our requirement as a SoC. SAADC: The SoC comes with a differential successive approximation register (SAR) analog-to-digital converter. It has eight different channels which means that we can collect up to 8 different signals simultaneously. The sampling rate can be high as 100K samples/second, which is much higher than our target rate of 1000 samples/second for ECG and 10 samples/second for pressure and temperature. GPIO: The general purpose input/output will be simply used as an indication that will display the status of the device, such as the battery level or connectivity, to a host device. This will be done by connecting LEDs to the GPIO pins and signaling them when necessary. Since we have more than 32 pins on the board, we have plenty of pins to toggle the LEDs. 5

Timer: The SoC also has a Timer module the runs on the high-frequency clock source which is typically at 16MHz. This extreme high-precision clock will enable us to have a precise interval for the ADC operation and will also schedule periodic jobs for us. This timer will be suitable as it has a resolution of 62.5 ns and a tolerance of less than +- 40 ppm. Bluetooth: The SoC includes a 2.4 GHz RF transceiver. In order for us to use it, the vendor provides a binary software implementing ble (bluetooth low energy) protocols. This software stack is called softdevice and is required in every project involving the use of ble. Our project will work in unison with the softdevice stack to stream the necessary data to the host device. Since this protocol can support up to 20 KBytes/Sec, it satisfies our data rate requirement. 6

2.C.2 Analog Circuit Unit The ultimate goal of the analog circuit unit is to implement the multiple sensors that are going to capture bio-signals and send them into our microcontroller. The sensors are located in a different parts of the knee brace and are going to measure the necessary values such as temperature, pressure, and usage of muscle. Since all of the sensors are basically a part of the analog circuit, we are going to use a multimeter and oscilloscope to measure the voltage from our sensor and see if it is properly sending a signal out or not. 2.C.2.1 Temperature Sensor The overall function of the temperature sensor is to measure the temperature of the knee and compare it with that of another part of the body, and see whether the knee is currently swollen up or not. The general temperature of the knee will be around 30~40 Celsius. It has to be sensitive enough to capture the difference of ±2 Celsius. 2.C.2.2 Pressure Sensor We are going to place pressure sensors under the strap of the knee brace (Appendix A has a pressure sensor placement). Pressure sensors will monitor if the user has properly worn the knee brace. The degree of tightness of the strap will be measured through pressure sensors, and they will send a analog signal (voltage) into the nrf52. It has to be flexible and sensitive enough to measure a little pressure difference on the strap. The adequate operating force measurement range should be between 0.04lbs to 4.5lbs. 2.C.2.3 EMG Sensor The purpose of the EMG sensor is to measure the usage of muscle. We are going to implement two electrode-based EMG sensors to indicate the usage of the leg muscle to prevent the user from excessive usage. Figure 1 shows the EMG sensor placement. Two electrodes will come out of the sensor and will be attached to the skin. We will use INA333 for preamplification and different types of filter such as 1st order High Pass filter to capture a better signal. 2.C.2.4 LED Indicator 7

An LED indicator will be a simple lighting device that indicate the different situations with a corresponding action. We are going to program the actions into our NRF52 and the LED indicator will work as we want. The LED indicator will have a low duty cycle ( <%5) in and consume less than 1mA of current draw. 2.C.3 Battery Module For the Battery module, we are going to use a 9V battery as our main source of power. Our goal is to maintain power availability for as long as possible - the optimal goal would be about two days without having to change a battery. The power circuitry will includes a DC-DC buck converter and the output should be near 3V. The battery module has to be safe enough to use near the human body and must protect our device from a over/under voltage that may cause damage in components. [2.e] Risk Analysis The block that poses the greatest risk for successful completion of our project is the Analog circuit unit and post-signal processing from it. Our device needs precise measurements of temperature, pressure, and EMG signals because we have to monitor the user in real-time to provide useful feedback of one s knee. After implementing the circuit, we have to test it in different circumstances and see if we can find out the optimal circuit design and range of measurements that yield the best result. 3. Ethics and Safety Concerning our project, we do not think there are much ethical concerns, because the knee brace we are modifying is for the sake of alleviating the discomforts of injured people. Aside from the radical case in which the knee brace were to be used as a physical weapon, there are not too many cases in which our product would cause concern to the public. We will be using a 9V alkaline battery as our power source, which has on average a capacity of 1000mAh. Electrical concerns such as discharge will be at a minimum, and the only mechanical concerns relevant will be of the existing knee brace currently out in the public. Some lab safety concerns we may have are related to soldering when creating our electrical circuit, both on a test breadboard and on the final PCB. 8

4. Appendix [4.a] Physical Design Pictures Figure 1: Front Side of Knee Brace and Sensor Location. 9

Figure 2: Back Side of the Knee Brace and Sensor Location. Figure 3: Right Side of the Knee Brace and the Batter Locations. 10