PERFORMANCE OF THE TUNER MECHANISM FOR SSR1 RESONATORS DURING FULLY INTEGRETED TESTS AT FERMILAB

Similar documents
Mechanical study of the «Saclay piezo tuner» PTS (Piezo Tuning System) P. Bosland, Bo Wu DAPNIA - CEA Saclay. Abstract

Tuning systems for superconducting cavities at Saclay

Completion of the first SSR1 cavity for PXIE

DESIGN OF SINGLE SPOKE RESONATORS FOR PROJECT X*

HIGH POWER PULSED TESTS OF A BETA=0.5 5-CELL 704 MHZ SUPERCONDUCTING CAVITY

PIP-II Superconducting RF Linac Status and Challenges" Leonardo Ristori! ICEC-ICMC Conference, New Delhi! 9 March 2016!!

RF STATUS OF SUPERCONDUCTING MODULE DEVELOPMENT SUITABLE FOR CW OPERATION: ELBE CRYOSTATS

Design of the 352MHz, beta 0.50, Double- Spoke Cavity for ESS

PI piezo Life Time Test Report. A. Bosotti, R. Paparella, F. Puricelli

Frequency Tuning and RF Systems for the ATLAS Energy Upgrade. Gary P. Zinkann

A 3 GHz SRF reduced-β Cavity for the S-DALINAC

THE TUNING SYSTEM FOR THE HIE-ISOLDE HIGH-BETA QUARTER WAVE RESONATOR

DEVELOPMENT OF A BETA 0.12, 88 MHZ, QUARTER WAVE RESONATOR AND ITS CRYOMODULE FOR THE SPIRAL2 PROJECT

Project X Cavity RF and mechanical design. T. Khabiboulline, FNAL/TD/SRF

S. Ghosh On behalf of Linac, IFR, Cryogenics, RF and beam transport group members. Inter University Accelerator Centre New Delhi India

ACHIEVEMENT OF ULTRA-HIGH QUALITY FACTOR IN PROTOTYPE CRYOMODULE FOR LCLS-II

Third Harmonic Superconducting passive cavities in ELETTRA and SLS

TESLA RF POWER COUPLERS DEVELOPMENT AT DESY.

ABSTRACT 1 CEBAF UPGRADE CAVITY/CRYOMODULE

QUARTER WAVE COAXIAL LINE CAVITY FOR NEW DELHI LINAC BOOSTER*

Superconducting RF cavities activities for the MAX project

L W C S1 S & & ILC L 1 C

Testing in a Combined Vibration and Acceleration Environment

3.9 GHz work at Fermilab

Overview of ERL Projects: SRF Issues and Challenges. Matthias Liepe Cornell University

Cavity Tuners. Outline. Tuner overview Concepts and examples. Focus: Fast piezo tuners for ERLs. Advanced piezo tuning.

The Coaxial Blade Tuner Final Report and Evaluation of Operation. A. Bosotti, C. Pagani, N. Panzeri, R. Paparella

A New 2 K Superconducting Half-Wave Cavity Cryomodule for PIP-II

HIGH POWER COUPLER FOR THE TESLA TEST FACILITY

SNS CRYOMODULE PERFORMANCE*

LOW-β SC RF CAVITY INVESTIGATIONS

LORENTZ FORCE DETUNING ANALYSIS OF THE SPALLATION NEUTRON SOURCE (SNS) ACCELERATING CAVITIES *

Low-Level RF. S. Simrock, DESY. MAC mtg, May 05 Stefan Simrock DESY

Cavity development for TESLA

Superconducting RF Cavity Performance Degradation after Quenching in Static Magnetic Field

Examination of Microphonic Effects in SRF Cavities

A Synchrotron Phase Detector for the Fermilab Booster

DEVELOPMENTS AND PROGRESS WITH ESS ELLIPTICAL CRYOMODULES AT CEA-SACLAY AND IPN-ORSAY -

SRF EXPERIENCE WITH THE CORNELL HIGH-CURRENT ERL INJECTOR PROTOTYPE

DEVELOPMENT OF QUARTER WAVE RESONATORS

Cornell ERL s Main Linac Cavities

HIGH POWER INPUT COUPLERS FOR THE STF BASELINE CAVITY SYSTEM AT KEK

COMPARISON OF BUFFERED CHEMICAL POLISHED AND ELECTROPOLISHED 3.9 GHz CAVITIES*

PROGRESS IN IFMIF HALF WAVE RESONATORS MANUFACTURING AND TEST PREPARATION

SUPERCONDUCTING PROTOTYPE CAVITIES FOR THE SPALLATION NEUTRON SOURCE (SNS) PROJECT *

Vibration studies of a superconducting accelerating

Booster High-level RF Frequency Tracking Improvement Via the Bias-Curve Optimization

OPTICS IN MOTION. Introduction: Competing Technologies: 1 of 6 3/18/2012 6:27 PM.

Acceptance test for the linear motion actuator for the scanning slit of the HIE ISOLDE short diagnostic boxes

DESIGN STUDY OF A 176 MHZ SRF HALF WAVE RESONATOR FOR THE SPIRAL-2 PROJECT

1. INTRODUCTION. Keywords: Piezo, Mechanism, Tip-tilt, Stability, Strain gages. BSM Mechanism context

OVERVIEW OF RECENT TUNER DEVELOPMENT ON ELLIPTICAL AND LOW-BETA CAVITIES

Status of the superconducting cavity development at RISP. Gunn Tae Park Accelerator division, RISP May 9th. 2014

To produce more powerful and high-efficiency particle accelerator, efforts have

EXPERIMENTAL RESULT OF LORENTZ DETUNING IN STF PHASE-1 AT KEK-STF

KEYWORDS: ATLAS heavy ion linac, cryomodule, superconducting rf cavity.

Fast Widely-Tunable CW Single Frequency 2-micron Laser

Digital LLRF Test on the Renascence Cryomodule

RENASCENCE * PERFORMANCE AND PROBLEMS ON FIRST TEST Feedthrough leaks sub 70 K. End group quenching

5. Transducers Definition and General Concept of Transducer Classification of Transducers

SLHiPP-2, Catania, Italy. A cryogenic system for the MYRRHA linac. Nicolas Chevalier, Tomas Junquera

Couplers for Project X. S. Kazakov, T. Khabiboulline

KEK ERL CRYOMODULE DEVELOPMENT

PiezoMike Linear Actuator

CAGE CAVITY: A LOW COST, HIGH PERFORMANCE SRF ACCELERATING STRUCTURE*

INSTRUMENTATION AND CONTROL SYSTEM FOR THE INTERNATIONAL ERL CRYOMODULE

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

DQW HOM Coupler for LHC

Designing Better Industrial Robots with Adams Multibody Simulation Software

Advances in CW Ion Linacs

Amit Roy Director, IUAC

1/2/2016. Lecture Slides. Screws, Fasteners, and the Design of Nonpermanent Joints. Reasons for Non-permanent Fasteners

C100 Cryomodule. Seven cell Cavity, 0.7 m long (high Q L ) 8 Cavities per Cryomodule Fits the existing Cryomodule footprint

Developments in Electromagnetic Inspection Methods I

Influence of Temperature Variations on the Stability of a Submm Wave Receiver

5.5 SNS Superconducting Linac

High Power Couplers for TTF - FEL

RF power tests of LEP2 main couplers on a single cell superconducting cavity

Installation and Characterization of the Advanced LIGO 200 Watt PSL

CONCEPTUAL DESIGN OF A FRETTING FATIGUE TESTING DEVICE

PHILTEC PHILTEC FIBEROPTIC SENSORS FROM INNER SPACE TO OUTER SPACE SOLVE YOUR MEASUREMENT PROBLEMS FIBEROPTIC SENSORS

School of Instrument Science and Opto-electronics Engineering, Hefei University of Technology, Hefei, China 2

THE MULTIPACTING STUDY OF NIOBIUM SPUTTERED HIGH-BETA QUARTER-WAVE RESONATORS FOR HIE-ISOLDE

R.Bachimanchi, IPAC, May 2015, Richmond, VA

Tests of the Spoke Cavity RF Source and Cryomodules in Uppsala

Automatic phase calibration for RF cavities using beam-loading signals. Jonathan Edelen LLRF 2017 Workshop (Barcelona) 18 Oct 2017

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

SC Cavity Development at IMP. Linac Group Institute of Modern Physics, CAS IHEP, Beijing,CHINA

R. J. Jones College of Optical Sciences OPTI 511L Fall 2017

PROGRESS IN THE ELLIPTICAL CAVITIES AND CRYOMODULE DEMONSTRATORS FOR THE ESS LINAC

JIJL NIOBIUM QUARTER-WAVE CAVITY FOR THE NEW DEEM BOOSTER LINAC

WHOLE BODY L-BAND RESONATOR WITH A WIDE RANGE FREQUENCY TUNING USING PIEZO ACTUATOR

INSTALLATION AND FIRST COMMISSIONING OF THE LLRF SYSTEM

High-speed wavefront control using MEMS micromirrors T. G. Bifano and J. B. Stewart, Boston University [ ] Introduction

Physical Design of Superconducting Magnet for ADS Injection I

POCKET DEFORMABLE MIRROR FOR ADAPTIVE OPTICS APPLICATIONS

10 Things to Consider when Acquiring a Nanopositioning System

SUPERCONDUCTING CAVITIES AND CRYOMODULES FOR PROTON AND DEUTERON LINACS

Fabry Perot Resonator (CA-1140)

Synchronization Control Scheme for Hybrid Linear Actuator Based on One Common Position Sensor with Long Travel Range and Nanometer Resolution

Transcription:

PERFORMANCE OF THE TUNER MECHANISM FOR SSR1 RESONATORS DURING FULLY INTEGRETED TESTS AT FERMILAB D. Passarelli, J.P. Holzbauer, L. Ristori, FNAL, Batavia, IL 651, USA Abstract In the framework of the Proton Improvement Plan-II (PIP- II) at Fermilab, a cavity tuner was developed to control the frequency of 325 MHz spoke resonators (SSR1). The behavior of the tuner mechanism and compliance with technical specifications were investigated through a campaign of experimental tests in operating conditions in the spoke test cryostat (STC) and at room temperature. Figures of merit for the tuner such as tuning range, stiffness, components hysteresis and overall performance were measured and are reported in this paper. INTRODUCTION With the goal of maintaining the cavity at the proper operational frequency: 325 MHz [1], the tuner was designed to compensate uncertainties in the frequency shift due to the cooldown from 293 K to 2Kand to minimize detuning caused by helium pressure fluctuations and microphonics perturbations. Cooldown uncertainties are estimated to be less than 135 khz, while the amplitude of perturbations is estimated to be less than 1 khz. These two values define respectively the requirements for coarse tuning and fine tuning. In order for the cavity to have a low pressure sensitivity (df/dp), studies showed that the stiffness of the tuner as seen by the cavity (passive stiffness) must be greater than 3 kn mm 1. Figure 1 shows the tuner prototype that was developed. The large scale tuning (135 khz) is accomplished via a stepper motor actuating a threaded rod and traveling nut, translating rotational motion into axial motion of a doublelever mechanism, compressing and relaxing the cavity at one of the two beam-pipes. Fine tuning (1 khz) is achieved with piezoelectric actuators (or piezos) which act as a fine tuning mechanism for the active compensation of perturbation sources like helium bath pressure fluctuations and mechanical vibrations. Other technical specifications for the tuner are described elsewhere [1, 2]. Figure 5 shows the operating principle of the double lever mechanism that allows coarse and fine tuning of the cavity. The two main arms hinged at one end and connected to the actuation system at the other end have a probe that tunes the cavity physically pushing on the beam pipe. The actuation system consists of a stepper motor held by a bracket and connected to a second arm. This arm is hinged at the other end and keeps the piezos in series with the motor. Work supported by Fermi Research Alliance, LLC under Contract No. DEAC2-7CH11359 with the United States Department of Energy donato@fnal.gov 1252 Figure 1: 3D model of the prototype model of SSR1 tuner. TESTS AT ROOM TEMPERATURE Several checks and preliminary measurements were done at room temperature prior to installation onto a cavity for cold testing. All structural components were checked to ensure their compliance with fabrication drawings. Testing Encapsulated Piezos The wire connections of the two encapsulated piezos were checked by measuring their resistance and impedance. Subsequently, both piezos were tested to monitor their elongation by applying different voltages from V to 2 V (maximum applicable voltage), see Figure 2. The required stroke of 68 μm at room temperature was achieved for both piezos. The piezos are controlled in voltage by 1 V stages during the scan and both present a hysteresis loop. Elongation [um] 8 7 6 4 3 2 1 Piezo 1 Piezo 2 2 4 6 8 1 12 14 16 18 2 Voltage [V] Figure 2: Elongation of Noliac piezos as a function of the voltage with an initial preload of 2 N. G1-Tuner

Tuner on the Test Bench The tuner was entirely assembled on a tuner stand to check the kinematic and elastic behavior of the system, see Fig. 4. The main probes of the tuner are pushing against bars that have been machined to have the same stiffness of the cavity (about 21 kn/mm). Load cells and dial indicators were used to monitor the distribution of forces in the mechanism and displacements of targeted components. Tuning cycles - Loads Several cycles were performed using the stepper motor and piezos. The entire system works as expected in the range of displacements needed to elastically tune the SSR1 cavity: x BP =2 μm. The flexible joints worked in the elastic range and did not show any inelastic deformation. The stepper motor has reached several times its maximum load of 13 N without noticeable issues. The exposure of the motor shaft to atmosphere was limited by purging the area with nitrogen. Both piezos were successfully actuated several times up to 2 V with different preloads. The load measured in each of the two encapsulated piezos is the same in all working conditions. This was for the most part achieved by adopting a pivoting mechanism which automatically distributes the loads evenly between the two piezos. This will allow uniform pressure on the beam-pipe flange. Mechanical Advantages Figure 3 shows the forces applied to the tuner components by the stepper motor (F m ), both piezos (F p ) and Nb-cavity (F c ). The mechanical advantage at the motor and piezos is calculated in eq. 1 and eq. 2, respectively. The geometrical parameters for the prototype tuner were recently optimized and are slightly different from what was reported in [1]. T m = L 1 + L 2 L 2 S1 + S 2 S 2 = 7 (1) T p = L 1 + L 2 L 2 = 2.2 (2) Mechanical advantages of the lever-system at the motor and piezos was measured and they match the data above. Figure 3: Scheme of force acting on the prototype tuner. L 1 = 353 mm, L 2 = 296 mm, S 1 = 67 mm, S 2 = 3 mm. G1-Tuner Figure 4: Tuner mounted on a test stand for initial measurements at room temperature. Passive Stiffness The passive stiffness of the system meets the specification of 3 kn mm 1. Tuner on a Dressed SSR1 Cavity The tuner was installed on a dressed SSR1 cavity (S1H- NR-17) and measurements were done to validate the efficiency of the mechanism both in coarse and fine regimes. Efficiencies Using dial indicators, an efficiency of E ct = 5.5% was measured during the coarse tuning satisfying in fact the specification of E ct = x BPc x c 37%. Translating the nut of the motor by a quantity x c [unit of length], the displacement obtained at the beam-pipe port of the cavity (x BP ) is equal to.5 x c. Also, the specification in fine tuning mode was met, E ft = x BPf x f 17%, having measured E ft = 44% with both piezos working and E ft = 29% with only one of the two piezos working. Finally it was verified that if one of the two piezos will fail in operation, the cavity can still be tuned with a fine tuning range bigger than the required range of 1 khz. Second Arm Nut Shaft Piezos Motor bracket Stepper motor w/ gear box U bar Second joint Main Arm Helium Vessel Probe Bellows SSR1 cavity First Joint Figure 5: Schematic representation of the working principle of the SSR1 tuner. 1253

TESTS AT COLD TEMPERATURE After completing all the checks and measurements at room temperature, cavity S1H-NR-17 with the tuner was assembled in STC with high-power coupler, see Figure 6. By adjusting the two screws for the fine alignment of the tuner, the probes were set with a 1.4 mm gap from the beam-pipe flange of the cavity such that at the end of the cooldown, due to the effect of the differential shrinkage between niobium and stainless steel, there would be a gap of.4 mm. This estimate was done based on results of thermal/structural FE analysis. Maintaining a gap between the tuner mechanism and the cavity beam pipe allows to record the frequency shift for the cavity due solely to the cool down effects. Additionally, such gap is set to avoid any damage to the mechanism. Temperature [K] 3 28 SSR1 cavity 26 Piezo 1 24 Piezo 2 22 Motor Housing 2 Motor Thermocouple First Joint 18 Main Probe 16 14 12 1 8 6 4 2 24 48 72 96 12 144 168 Time [h] Figure 7: Temperature profiles of targeted components during cooldown process of the SSR1 cavity (S1H-NR-17). not touching the beam-pipe flanges, as expected. The resonant frequency of the cavity shifted +337.721 khz, from 324.974 9 MHz to 325.311 73 MHz. The estimated frequency shift by finite-element analysis was +285 khz. This result will be used as a reference number to properly tune (inelastic tuning) the next dressed cavities so that the resonant frequency of the cavity will be as close as possible to the targeted frequency of 325. MHz at 2 K with the tuner engaged. Figure 6: Installation of SSR1 cavity (S1H-NR-17) with tuner and coupler into the Spoke cavity Test Cryostat (STC) at Fermilab. Cooldown It was of interest to investigate the behavior of the cavity frequency and temperatures of components during the cooldown from 293 K to 2 K. Temperatures Several resistance temperature detectors (RTDs) were installed on the tuner components: housing of piezo 1, housing of piezo 2, motor housing, first flexible joint, and main arm, to check the distribution of temperature in operating conditions. Also, the stepper motor has a thermocouple in housing. Figure 7 shows the data collected by the temperature sensors as function of time during the cooldown of the SSR1 cavity. The motor housing was also connected to 8 K lines by thermal straps. The results will be useful as inputs in thermal/structural finite-element analysis for studying and optimizing the behavior of the system (cavity and tuner) due to thermal contraction of the materials during cooldown. Frequency Shift At the end of the cooldown process, when the niobium cavity reached 2K, the tuner probes were 1254 Coarse Tuning Mode Coarse Tuning Range The -position of the tuner, see Fig. 8, when the probes are just in contact with the beam-pipe flange observing a frequency shifts of few tens of Hertz, was found moving the stepper motor of about 27 steps toward the cavity at the resonant frequency of 325.311 7 MHz. It has to be noted that 27 steps corresponds to a probes displacement of about.4 mm, the gap that was expected setting the probes at a distance of 1.4 mm during the setup. Using the stepper motor, the tuner was put in the "startposition", which consists in shifting the resonant frequency of the cavity of 8 khz, see Fig. 8. In this configuration both piezos are preloaded with 84 N, as required in the vendor datasheet. Then, the full tuning range of 135 khz, from the start-point to the end-position, was scanned by 25 khz stages checking the linear-elastic behavior of the cavity and tuner after each stage. Fitting of the range scan gives a motor resolution of -4.85 Hz/step. The full cavity range is 26 steps for 135 khz. Motor - Load The force seen by the motor goes from N when the motor is in -position to 123 N with the tuner in end-position. Those forces are estimated using the frequency shift from Fig. 8, the mechanical advantage of Eq. 1, the cavity sensitivity df/dl=52 khz/mm, and cavity G1-Tuner

6 [khz] -8 1 1 2-215 135 khz 8 khz [khz] 4 2 2 4 2 1 2 2.7 3 4 5 5.3 6 x 1 4 [steps] Figure 8: Tuner setup in the tuning range. 6 1 7 2 2 7 1 [steps] Figure 9: Scan around the start-position moving the stepper motor ±1 steps by 1 step stages. stiffness k c = 21 N/mm. The maximum force is below the acceptable force for the motor. 6 Motor - Temperature It was interesting to monitor temperatures at various locations on the tuner during this activity. Running the motor for this test over about an hour significantly raised the temperature of the in-motor thermocouple from 1 K to 33 K, as well as the housing from 85 K to 1 K. It is clear that the duty cycle of the motor should be lowered in future measurements to keep the motor temperature lower. It is estimated that the motor was run approximately 1 5 step/hour during this time. Future measurements will endeavor to keep the step rate to half this or lower, with temperatures being monitored to see if a further reduction is required, though in operating condition the stepper motor will be used for an amount of time that does not exceed 2 minutes. Motor Scans The stepper motor scans were done around the start-position (see Fig. 9) and the end-position (see Fig. 1) of the tuning range by 1 step stages. Frequency per step was measured at the end outside of the lash region, and the frequency spread from hysteresis was measured in the same region. Hysteresis went up from 43 Hz to 1.535 khz. The averaged motor resolution went down from 5.12 Hz/step to 4.69 Hz/step. Fine Tuning Mode The tuning range in fine tuning mode was measured positioning the tuner in the start-position and end-position while a DC bias was applied to each piezos individually. The piezomaster box was used with a drive voltage applied by hand. The piezomaster gain as well as the monitor port gain was calibrated beforehand, and the applied voltage was swept from V to 1 V and back by 25 V steps. It was decided to follow a conservative approach on the use of the piezos, limiting the maximum voltage to 1 V instead of going up to the limit of 2 V. Because the cable for applying the same voltage to both piezos was broken, voltage G1-Tuner [khz] 4 2 2 4 6 1 7 2 2 7 1 [steps] Figure 1: Scan around the end-position moving the stepper motor ±1 steps by 1 step stages. could only be applied to one piezos at a time, which means that about half of the stroke is lost due to the mechanical disadvantage of the mechanism in this working condition. Fine Tuning Range - Start Position Figure 11 shows the measurement of both piezos with the tuner positioned at the start-position (low preloading) of the tuning range. A full range of about 6 Hz per 1 V applied was measured. In normal operating conditions, with both piezos working simultaneously up to 2 V, the fine tuning range would be of about 2.5 khz exceeding the requirements on range 1 khz. The tuner hysteresis was about 12 Hz for both piezos applying 1 V. Fine Tuning range - End Position Figure 12 shows the measurement of both piezos with the tuner positioned at the end-position (high preloading) of the tuning range. A full range of about 3 Hz was measured. In normal operating conditions, both piezos working simultaneously up to 2 V, 1255

a through study of interaction between tuner loading and performance was not completed. [khz] 1 2 4 5 Piezo 1 Piezo2 7 2 4 6 8 1 Figure 11: Scan around the start-position (lowest preload) actuating one piezo at the time by 25 V stages up to 1 V. REFERENCES [1] D. Passarelli, L. Ristori, SSR1 Tuner Mechanism: Passive and Active Device, Proceedings of LINAC 14, Geneva, Switzerland. [2] Fermilab Engineering Specification, Specification for SSR1 Tuner, TD-15-17, https://web.fnal.gov/ organization/tdnotes/shared%2documents/215% 2Tech%2Notes/TD-15-17.pdf?Web=1 [3] W. Schappert, J.P. Holzbauer, Yu. Pischalnikov, Resonance Control for Narrow-Bandwidth, Superconducting RF Applications, SRF215, these proceedings, TUPB95, Whistler, BC, Canada. [khz] 1 2 4 5 Piezo 1 Piezo2 7 2 4 6 8 1 Figure 12: Scan around the start-position (lowest preload) actuating one piezo at the time by 25 V stages up to 1 V. the fine tuning range would be of about 1.2 khz. Also in worst working condition, the specification of the fine tuning range is satisfied. The tuner hysteresis was about 1 Hz for both piezos applying 1 V. CONCLUSION AND FUTURE WORK The validation of the design for this first prototype of tuner mechanism for the SSR1 cavity is complete. All specifications in terms of stiffness, tuning ranges, tuning efficiencies, and resolutions of the active components are met. Also, this prototype tuner was successfully used in preliminary studies of resonant control [3] for SSR1 cavities. The fast tuner was used to drive cavity characterization routines, including mechanical to electrical transfer functions. Next activities will be aimed at defining an acceptable threshold of hysteresis for both motor and piezos, that does not influence the dynamic behavior of the tuner. Additionally, studies of active resonance stabilization were done, but 1256 G1-Tuner