IF THE END REACTION IS 350# TO 750# THE FOLLOWING PERIMETER ANCHORING CAN BE USED. HEAD AND SILL CONDITIONS WITH EXPOSED INTERIORS SHIMS

Similar documents
BuildingEnvelope Oldcastle ( ) -

INSTALLATION INSTRUCTIONS

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual

YCW 752 Outside Glazed Curtain Wall System Installation Manual

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual

DHS-500 IMPACT SYSTEM INSTALLATION MANUAL

YWE 40 T Window Wall System Installation Manual

YES 600 Thermal Clip Storefront System Installation Manual

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC

Installation Instructions

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B. EnCORE FEBRUARY, 2012 EC PART NO.

Storefront Installation Guide

YCW 750 IG Inside Glazed Curtain Wall System Installation Manual

Installation Instructions

YHC 300 SSG Structural Silicone Glazed Curtain Wall System Installation Manual

INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass

YES 40 FS/FI Storefront System Installation Manual

YHC 300 IG Inside Glazed Curtain Wall System Installation Manual

FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE:

RELIANCE -LT INSTALLATION AND GLAZING MANUAL

Series Advanced and alternate. Installation Instructions

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015

Theut Company LLC 1317 Bus. Hwy 71 N Columbus, Tx Ph. (979) Fax (979)

SERIES BW3250 BLAST WALL TABLE OF CONTENTS INSTALLATION INSTRUCTIONS GENERAL NOTES

YES 45 FS/FI Storefront System Installation Manual

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

YES 45 TU Thermal Storefront System Installation Manual

Series 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL

RELIANCE CURTAIN WALL INSTALLATION AND GLAZING MANUAL

Installation Instructions for Vista Air Vertically Folding Walls

INSTALLATION INSTRUCTIONS TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T

INSTALLATION INSTRUCTIONS TRIFAB 451UT SCREW SPLINE ASSEMBLY TRIFAB 451UT. AUGUST, 2010 (Part No. 452T-CG-970) EC

TCR 250 THERMAL COMPOSITE RIBBON WINDOW

INSTALLATION INSTRUCTIONS

YES 45 XT High Performance Thermal Storefront System

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

Series 406 storefront. Installation Instructions

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012

YSG 40/50/50T Window Wall System Installation Manual

INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass

Thermally Broken Framing and Door Installation

14000 Series. Fabrication and Installation Instructions

I N S T A L L A T I O N

Heavy Wall Applied Stop Tube Frame and Door Installation

14000 Series. Fabrication and Installation Instructions

PartnerPak Studio Fabrication

4500 Series. Fabrication and Installation Instructions

Series 525 impact storefront. Installation Instructions

INSTALLATION INSTRUCTIONS

Assembly and Installation Instructions Section 1

BuildingEnvelope Oldcastle ( ) -

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! OCTOBER Phone: OLDCASTLE ( ) Web Address:

BuildingEnvelope Oldcastle ( ) -

SERIES 406X. Installation Instructions. Place photography here. Don t go over grey area. (size w x h )

ARCHITECTURAL STICK SYSTEMS

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

Series 960 wall storefront. Installation Instructions

CURTAIN WALL INSTALLATION AND GLAZING MANUAL

Illustration Part Description Base List Weight/ Ft./ Box Number Price/S.L. S.L. S.L. Qty.

SERIES 2100/2200 CURTAIN WALL

SERIES 2100/2200 CURTAIN WALL

YHS 50 FS Storefront System & Model 35H/50H Door Installation Manual

BuildingEnvelope Oldcastle ( ) -

Series 955 Tech Set storefront. Installation Instructions

ELEPHANT DOOR SYSTEMS SERIES E1200

Series Exterior glazed curtain wall. Installation Instructions

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

Architectural Testing AAMA 501 TEST REPORT. Report Number: C Rendered to: Tubelite, Inc. Walker, Michigan

Series Sloped glazed Curtain wall. Installation Instructions

YHS 50 TU Storefront System & Model 35H Door Installation Manual

Sun Control-Solar Eclipse-Solar Shelf

Heavy Wall Applied Stop Tube Frame and Door Installation

SKIN SYSTEM ORDER FORM NOTES AND REQUIREMENTS

western window systems westernwindowsystems.com installation instructions non-pocket 2-1/4 panels

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

YSD 600 T/TH Sliding Door System Installation Manual

Installation Manual. YSD 600 T/TH Sliding Door. YSD 600 T/TH Sliding Door System

Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing)

Table of Contents. Typical elevation & cut lengths. General construction notes. General installation notes. Typical jamb assembly

Versatrac R-System Stock Extrusions, Clips and Accessories

Reliance StormMax High Performance Curtain Wall - 3 x 10 Table of Contents (Drawing numbers ie V9662 used as CAD detail reference only )

SECTION C1 INSTALLATION INSTRUCTIONS

INOVO 2-LITE SLIDING PATIO DOOR

Design Considera ons & Installa on Guidance

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

SERIES 5001 SLIDING GLASS DOOR PATIO DOORS INSTALLATION GUIDE

BuildingEnvelope Oldcastle ( ) -

GENERAL INSTALLATION GUIDELINES

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS

GENERAL INSTALLATION GUIDELINES

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

SERIES CF450 INSTALLATION INSTRUCTIONS. SERIES CF450 1¾ x 4½ - B1. Fabrication for Panel Assembly. High Performance Non-Thermal Storefront System

SERIES CF451T INSTALLATION INSTRUCTIONS. SERIES CF451T 2 x 4½ - B2. Fabrication for Panel Assembly. High Performance Thermal Storefront System

I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS

INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1-1/2" TRIM OFFICE PARTITIONS

Swing Door Installation Manual

Series 526 Thermal impact storefront. Installation Instructions

Transcription:

162-960 1 OF 5 USE THESE INSTRUCTIONS IN CONJUNCTION WITH INSTALLATION INSTRUCTIONS 162-970. PERIMETER ANCHORING TO CALCULATE END REACTIONS MODULE(FT) X LENGTH(FT) X WIND LOAD(PSF) A IF THE END REACTION IS 350# OR LESS USING "F" PERIMETERS CAN BE USED. 162-017 "F" PERIMETER AT 162-176 AT PERIMETER FASTENER 24" ON CENTER OR AS REQUIRED B IF THE END REACTION IS 350# TO 750# CAN BE USED. DRILL 1/2" DIA. HOLE FOR HOLE PLUGS. DRILL CLEARANCE HOLE FOR FASTENER. MAXIMUM FASTENER SPACING IS 24". SEE BELOW FOR ADDITIONAL HEAD AND SILL FASTENERS. B IF THE END REACTION IS 350# TO 750# CAN BE USED. EQUALS END REACTION IN POUNDS A EXAMPLE 2 5' X 7' X 20 PSF 2 = 350# IF THE END REACTION IS 350# OR LESS USING "F" PERIMETERS CAN BE USED. USE GLAZING TEMPORARIES TO HOLD FRAMING MEMBERS TO PERIMETERS UNTIL PRESSURE PLATES ARE INSTALLED. PERIMETER FASTENER 24" ON CENTER OR AS REQUIRED HEAD AND SILL CONDITIONS WITH EXPOSED INTERIORS CONTINUOUS SNAP-IN FILLER 162-021 6" SYSTEM 162-020 7-1/2" SYSTEM LENGTH EQUALS DLO MINUS 3-1/2" WHEN SHEAR ONLY OCCUR. LENGTH EQUALS DLO MINUS 9" WHEN "F" AND "T" ANCHORS OCCUR. FASTENER SHIMS PERIMETER PRESSURE PLATE 162-505 162-506 REFERENCE FABRICATION DETAILS SHEET #2. INTERIOR SEAL REQUIRED ONLY AT VISION AREAS 1/2" HOLE 420-460 OR 027-633 HOLE PLUG AT THE HEAD AND SILL, INSTALL FASTENERS 6" EACH SIDE OF VERTICALS AND NO MORE THAN 24" ON CENTER. AT LEAST 3 FASTENERS ARE REQUIRED PER LITE OPENING. 6" 6" LAST BAY HORIZ. REQUIRES. REFERENCE DETAILS SHEET #5. FASTENER 420-460 OR 027-633 HOLE PLUG 162-017 "F" PERIMETER AT 162-176 AT HEAD AND SILL CONDITIONS WITH FINISHED INTERIORS SNAP-IN FILLER AND SEAL ONLY REQUIRED AT VISION AREAS THIS ANCHORING PROVIDES ADEQUATE SUPPORT FOR THE WALL PROVIDED THE END REACTION AT THE VERTICALS DOES NOT EXCEED 750#. HOWEVER, THE PERIMETER STRUCTURE AND THE PERIMETER FASTENERS ABILITY TO CARRY THE LOAD MUST BE CHECKED PER JOB. CONTACT FACTORY ENGINEERING FOR ASSISTANCE. AT PERIMETER PRESSURE PLATES TOP AND BOTTOM END CAPS REQUIRED FOR ALL VERTICALS REFERENCE INSTRUCTIONS 162-970 PERIMETER PRESSURE PLATES CAN BE USED WITH "F" AND "T" ANCHORS REFERENCE SHEET #2 SNAP-IN SHIM SUPPORTS 162-316 6" SYSTEM 162-317 7-1/2" SYSTEM AT FINISHED INTERIOR AT EXPOSED INTERIOR TUBULAR MULLIONS MAY ALSO BE USED AT JAMBS 1600 SYSTEM 1 162-960 1 OF 5

162-960 2 OF 5 USE THESE INSTRUCTIONS IN CONJUNCTION WITH INSTALLATION INSTRUCTIONS 162-970. C PERIMETER ANCHORING IF THE END REACTION IS 750# AND GREATER "F" AND "T" ANCHORS ARE REQUIRED AT EACH VERTICAL. PERIMETER MEMBERS MAY BE ANCHORED AS IN METHODS "A" OR "B" DEPENDING UPON THE JOB CONDITIONS. "F" OR "T" ANCHORS SHOULD NOT BE USED IN CONDUCTION WITH STEEL REINFORCING WITHOUT CHECKING THE STRUCTURAL INTEGRITY OF THE ANCHORS. CONTACT FACTORY ENGINEERING FOR ASSISTANCE. "F" ANCHORS CAN NOT BE USED WITH OPEN BACK VERTICAL JAMBS. D HEAD/SILL SHEAR BLOCK/ANCHORS. REFERENCE STEP #4, SHEET #2, AND STEP #7, SHEET #3 IN THE 162-970 INSTALLATION INSTRUCTIONS. STRUCTURAL INTEGRITY OF ANCHOR AND FASTENERS MUST BE CHECKED BY FACTORY ENGINEERS. PERIMETER MEMBERS MAY BE ANCHORED AS IN METHODS "A" OR "B" DEPENDING UPON THE JOB CONDITIONS. USE THIS SHEAR BLOCK WITH OPEN BACK S WHEN POSSIBLE. IF TUBULAR S ARE USED A IS REQUIRED. REFERENCE FABRICATION DETAILS ON SHEET #4. VERTICAL HOLE PREPS ARE THE SAME AS TYPICAL SHEAR. REFERENCE INSTALLATION INSTRUCTION 162-983 EXTERIOR FRAME PERIMETERS WHEN USING "F" AND "T" ANCHORS FOR PERIMETER ANCHORING "C", THE FOLLOWING PERIMETER FRAMING CAN BE USED AT THE HEAD AND SILL ONLY. "F" ANCHORS REQUIRE TUBULAR VERTICAL MULLIONS AT JAMBS. BUT CAN NOT BE USED WITH SHEAR BLOCK/ ANCHOR FOR PERIMETER ANCHORING "D". USE SHEAR 162-384 6" SYSTEM 162-385 7 1/2" SYSTEM HEAD CONDITION PRESSURE PLATE FABRICATION LENGTH OF PRESSURE PLATE EQUALS DAYLITE OPENING MINUS 3/4". ATTACHMENT ARE FACTORY PUNCHED AT 3" ON CENTER..266 DIA.(H DRILL). WEEP ARE TO BE LOCATED 3- FROM EACH END AS DRILL 5/16" FOR FIBERGLASS PRESSURE PLATES: FOR BEST RESULTS OPERATOR MUST USE SHARP 3 FLUTE HIGH STRENGTH STEEL OR COBALT DRILL OR CARBIDE "PINEAPPLE CUT" TOOL. SILL POSITION. UNLESS NOTED OTHERWISE WEEPS NOT REQUIRED AT HEAD 1-25/32" 3- WEEP "F" ANCHOR FOR JAMBS 162-308 AT 6" SYSTEM 162-311 AT 7 1/2" SYSTEM 162-354 AT 10 1/2" SYSTEM "T" ANCHOR FOR INTERMEDIATE VERTICAL 162-309 AT 6" SYSTEM 162-312 AT 7 1/2" SYSTEM 162-355 AT 10 1/2" SYSTEM STRUCTURAL SHIMMING IS REQUIRED AT SILL TO ACCOMPLISH DESIGNED WIDTH. JAMB SHEAR BLOCK/ANCHOR 162-314 AT 6" SYSTEM 162-315 AT 7 1/2" SYSTEM PERIMETER FRAME 162-203 1" FOR 6" SYSTEM 162-204 1" FOR 7 1/2" SYSTEM 162-205 FOR 6" SYSTEM 162-206 FOR 7 1/2" SYSTEM 162-562 3" MAX ATTACHMENT DLO MINUS 3/4" TYPICAL VERTICAL MULLION MULLION SHEAR BLOCK/ANCHOR 162-342 AT 6" SYSTEM 162-343 AT 7 1/2" SYSTEM 162-505 162-506 STOCK LENGTH 162-335 SILL CONDITION VERTICAL PRESSURE PLATE LENGTH EQUALS VERTICAL MULLION HEIGHT. TYPICAL "T" ANCHOR ATTACHMENT ARE FACTORY PUNCHED AT 3" ON CENTER..266 DIA.(H DRILL). FASTENER PREPS AS REQUIRED. CONTACT FACTORY ENGINEERING FOR ASSISTANCE. TYPICAL VERTICAL MULLION CLIPS AS REQUIRED FOR WIND LOAD 162-960 2 OF 5

162-960 3 OF 5 EXTERIOR COVER FABRICATION LENGTH OF COVER MINUS 1/16". COVER BOTTOM 162-006 7/32" 5/16" DIA. WEEP. LOCATED AT BOTH ENDS. 2" DLO MINUS 1/16" 6" SYSTEM 162-203 162-094 7-1/2" SYSTEM 162-204 162-095 10-1/2" SYSTEM 162-064 1 3/8" 1 1/2" TYP. VERTICAL EXTERIOR COVER LENGTH EQUALS PRESSURE PLATE LENGTH UNLESS NOTED OTHERWISE ON APPROVED SHOP DRAWINGS 7/8" 1 2" 162-003 7/8" 1 3 1/2" 1 DRILL.182 DIA. (#14 DRILL) DRILL.173 DIA. (#17 DRILL) DRILL.173 DIA. (#17 DRILL) FIXTURE 162-374 IS C/L OF. 9/32" WEEP LOCATION FOR DEEP AND CUSTOM COVERS FIXTURE 162-351 IS C/L OF. FIXTURE 162-351 IS C/L OF. AT 10-1/2" SYSTEM 4 AT 6" SYSTEM 2 AT 7-1/2" SYSTEM 2 162-960 3 OF 5

162-960 4 OF 5 FABRICATION FABRICATION FABRICATION FABRICATION AND OPEN BACK FILLER LENGTH MINUS 1/32". 6", 7-1/2" AND 10-1/2" SYSTEMS END DRILL FIXTURE 162-352 2 FOR TYPICAL SHEAR 2 FOR LAST BAY SHEAR OPEN BACK FOR "F" SHEAR BLOCK AT TYPE "D" ANCHORING. 0.111 4-162-090 1.438 X 82 CTSK OR COIN POSITION ON END OF HEAD/SILL END DRILL FIXTURE 162-393 AT PERIMETER FRAME POSITION 162-375 BY ALIGNING SPRING PINS WITH EDGE 162-094 TUBULAR FOR "F" SHEAR BLOCK AT TYPE "D" ANCHORING. ADDITIONAL LAST BAY SHEAR BLOCK PREP AND FOR 10-1/2" SYSTEM 162-065 1.438 X 82 CTSK OR COIN POSITION 162-393 BY ALIGNING SPRING PINS WITH EDGES MUST BE MADE AFTER LAST BAY SHEAR BLOCK HOLE PREPS. 162-065 1 2 3/16" 2 1 4 1 ADDITIONAL SHEAR BLOCK PREP FOR 10-1/2" SYSTEM.182 DIA. TAPPING HOLE (#14 DRILL).438 X 82 CTSK 162-065 162-203.438 X 82 CTSK 1.228 DIA. CLEAR HOLE (#1 DRILL) 162-960 4 OF 5

162-960 5 OF 5 FABRICATION ADAPTER FABRICATION PERIMETER FILLER FABRICATION LAST BAY FOR SHEAR BLOCK AT TYPE "B" ANCHORING. SPANDREL ADAPTERS ADAPTERS ARE SQUARE CUT ADAPTER LENGTH MINUS 1/16" PERIMETER FILLER BOTH ENDS ALL HEAD AND SILL FILLERS. LENGTH EQUALS DAYLITE OPENING PLUS 1-1/2" 1-1/2" 2" 162-019 162-019 VERTICAL ADAPTER LENGTH PLUS 1-3/8" BELOW A VERTICAL SPLICE, VERTICAL ADAPTER LENGTH PLUS 3/16" 162-022 3/8" 1-1/2" PERIMETER FABRICATION 162-023 3/8" VERTICAL MULLION FOR "F" PERIMETER AT TYPE "A" ANCHORING. 10-1/2" SYSTEM TUBULAR AT TYPE "C" ANCHORING. TONGUE 162-065 5/16" 6 23/32" 15/16" VERTICAL FILLERS ARE SQUARE CUT AND THE SAME LENGTH AS VERTICAL MULLIONS. 5 3/4" TONGUE 15/16" 162-013 95449-70 07/11/08 162-960 5 OF 5